• Title/Summary/Keyword: 정원산정

Search Result 65, Processing Time 0.019 seconds

Experimental investigation of turbulent effects on settling velocities of inertial particles in open-channel flow (개수로 흐름에서 난류가 관성입자의 침강속도에 미치는 영향에 대한 실험연구)

  • Baek, Seungjun;Park, Yong Sung;Jung, Sung Hyun;Seo, Il Won;Jeong, Won
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.11
    • /
    • pp.955-967
    • /
    • 2022
  • Existing particle tracking models predict vertical displacement of particles based on the terminal settling velocity in the stagnant water. However, experimental results of the present study confirmed that the settling velocity of particles is influenced by the turbulence effects in turbulent flow, consistent with the previous studies. The settling velocity of particles and turbulent characteristics were measured by using PTV and PIV methods, respectively, in order to establish relationship between the particle settling velocity and the ambient turbulence. It was observed that the settling velocity increase rate starts to grow when the particle diameter is of the same order as Kolmogorov length scale. Compared with the previous studies, the present study shows that the graphs of the settling velocity increase rate according to the Stokes number have concave shapes for each particle density. In conclusion, since the settling velocity in the natural flow is faster than in the stagnant water, the existing particle tracking model may estimate a relatively long time for particles to reach the river bed. Therefore, the results of the present study can help improve the performance of particle tracking models.

Reliability Estimation of Static Design Methods for Driven Steel Pipe Piles in Korea (국내 항타강관말뚝 설계법의 신뢰성평가)

  • Huh, Jung-Won;Park, Jae-Hyun;Kim, Kyung-Jun;Lee, Ju-Hyung;Kwak, Ki-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.12
    • /
    • pp.61-73
    • /
    • 2007
  • As a part of Load and Resistance Factor Design(LRFD) code development in Korea, in this paper an intensive reliability analysis was performed to evaluate reliability levels of the two static bearing capacity methods for driven steel pipe piles adopted in Korean Standards for Structure Foundations by the representative reliability methods of First Order Reliability Method(FORM) and Monte Carlo Simulation(MCS). The resistance bias factors for the two static design methods were evaluated by comparing the representative measured bearing capacities with the design values. In determination of the representative bearing capacities of driven steel pipe piles, the 58 data sets of static load tests and soil property tests were collected and analyzed. The static bearing capacity formula and the Meyerhof method using N values were applied to the calculation of the expected design bearing capacity of the piles. The two representative reliability methods(FORM, MCS) based computer programs were developed to facilitate the reliability analysis in this study. Mean Value First Order Second Moment(MVFOSM) approach that provides a simple closed-form solution and two advanced methods of FORM and MCS were used to conduct the intensive reliability analysis using the resistance bias factor statistics obtained, and the results were then compared. In addition, a parametric study was conducted to identify the sensibility and the influence of the random variables on the reliability analysis under consideration.

Estimation of Carbon Stock and Annual CO2 Uptake of Four Species at the Sejong National Arboretum - Pinus densiflora, Metasequoia glyptostroboides, Aesculus turbinata, Chionanthus retusus - (국립세종수목원 교목 4종의 탄소 저장량 및 연간 이산화탄소 흡수량 평가 - 소나무, 메타세쿼이아, 칠엽수, 이팝나무를 대상으로 -)

  • Hak Koo KIm;Yong Sik Hong;Yun Kyung Lim;I Seul Yun;Ki Seok Do;Chan Hyung Jung;Chi Mun Lee;Hoi Eun Roh;Sin Koo Kang;Chan-Beom Kim
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.1
    • /
    • pp.41-48
    • /
    • 2023
  • This study was conducted to confirm the possibility of a new carbon stock in the Sejong National Arboretum, a major urban greenspace in Sejong-si. This study involved field and ground surveys of 1,336 trees, including 794 Pinus densiflora trees with a diameter at breast height (DBH) of above 5.5cm, which are the most planted in the Sejong National Arboretum, Chionanthus retusus 154 trees planted, Metasequoia glyptostroboides 216 trees, and Aesculus turbinata 172 trees as street trees. Measurements were performed from April to November. Based on the results of the survey, the carbon storage and annual carbon stock were calculated using the annual carbon stock estimation equation used in the forest carbon offset projects. As a result of comparing the carbon stock of the 12cm diameter class, which is the most distributed of four major trees, it was found in the order of C. retusus (0.0136tC/tree), P. densiflora (0.0126tC/tree), M. glyptostroboides (0.0092tC/tree), and A. turbinata (0.0076tC/tree). In addition, the field survey measurement data compared with terrestrial LiDAR measurement data for 20 trees showed a difference of 10.0cm in tree height and 1.7cm in diameter at breast height (p<0.05). In the future, additional carbon stock and annual uptake of other species planted in the arboretum are expected to promote the carbon uptake effect of the arboretum and contribute to the achievement of the national NDC. In the long term, it is also necessary to develop the carbon uptake factor of trees and shrubs mainly used to calculate the exact carbon uptake amount of trees mainly used in urban forests and gardens.

Wave Analysis and Spectrum Estimation for the Optimal Design of the Wave Energy Converter in the Hupo Coastal Sea (파력발전장치 설계를 위한후포 연안의 파랑 분석 및 스펙트럼 추정)

  • Kweon, Hyuck-Min;Cho, Hongyeon;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.3
    • /
    • pp.147-153
    • /
    • 2013
  • There exist various types of the WEC (Wave Energy Converter), and among them, the point absorber is the most popularly investigated type. However, it is difficult to find examples of systematically measured data analysis for the design of the point absorber type of power buoy in the world. The study investigates the wave load acting on the point absorber type resonance power buoy wave energy extraction system proposed by Kweon et al. (2010). This study analyzes the time series spectra with respect to the three-year wave data (2002.05.01~2005.03.29) measured using the pressure type wave gage at the seaside of north breakwater of Hupo harbor located in the east coast of the Korean peninsula. From the analysis results, it could be deduced that monthly wave period and wave height variations were apparent and that monthly wave powers were unevenly distributed annually. The average wave steepness of the usual wave was 0.01, lower than that of the wind wave range of 0.02-0.04. The mode of the average wave period has the value of 5.31 sec, while mode of the wave height of the applicable period has the value of 0.29 m. The occurrence probability of the peak period is a bi-modal type, with a mode value between 4.47 sec and 6.78 sec. The design wave period can be selected from the above four values of 0.01, 5.31, 4.47, 6.78. About 95% of measured wave heights are below 1 m. Through this study, it was found that a resonance power buoy system is necessary in coastal areas with low wave energy and that the optimal design for overcoming the uneven monthly distribution of wave power is a major task in the development of a WEF (Wave Energy Farm). Finding it impossible to express the average spectrum of the usual wave in terms of the standard spectrum equation, this study proposes a new spectrum equation with three parameters, with which basic data for the prediction of the power production using wave power buoy and the fatigue analysis of the system can be given.

Development of Traffic Volume Estimation System in Main and Branch Roads to Estimate Greenhouse Gas Emissions in Road Transportation Category (도로수송부문 온실가스 배출량 산정을 위한 간선 및 지선도로상의 교통량 추정시스템 개발)

  • Kim, Ki-Dong;Lee, Tae-Jung;Jung, Won-Seok;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.3
    • /
    • pp.233-248
    • /
    • 2012
  • The national emission from energy sector accounted for 84.7% of all domestic emissions in 2007. Of the energy-use emissions, the emission from mobile source as one of key categories accounted for 19.4% and further the road transport emission occupied the most dominant portion in the category. The road transport emissions can be estimated on the basis of either the fuel consumed (Tier 1) or the distance travelled by the vehicle types and road types (higher Tiers). The latter approach must be suitable for simultaneously estimating $CO_2$, $CH_4$, and $N_2O$ emissions in local administrative districts. The objective of this study was to estimate 31 municipal GHG emissions from road transportation in Gyeonggi Province, Korea. In 2008, the municipalities were consisted of 2,014 towns expressed as Dong and Ri, the smallest administrative district unit. Since mobile sources are moving across other city and province borders, the emission estimated by fuel sold is in fact impossible to ensure consistency between neighbouring cities and provinces. On the other hand, the emission estimated by distance travelled is also impossible to acquire key activity data such as traffic volume, vehicle type and model, and road type in small towns. To solve the problem, we applied a hierarchical cluster analysis to separate town-by-town road patterns (clusters) based on a priori activity information including traffic volume, population, area, and branch road length obtained from small 151 towns. After identifying 10 road patterns, a rule building expert system was developed by visual basic application (VBA) to assort various unknown road patterns into one of 10 known patterns. The expert system was self-verified with original reference information and then objects in each homogeneous pattern were used to regress traffic volume based on the variables of population, area, and branch road length. The program was then applied to assign all the unknown towns into a known pattern and to automatically estimate traffic volumes by regression equations for each town. Further VKT (vehicle kilometer travelled) for each vehicle type in each town was calculated to be mapped by GIS (geological information system) and road transport emission on the corresponding road section was estimated by multiplying emission factors for each vehicle type. Finally all emissions from local branch roads in Gyeonggi Province could be estimated by summing up emissions from 1,902 towns where road information was registered. As a result of the study, the GHG average emission rate by the branch road transport was 6,101 kilotons of $CO_2$ equivalent per year (kt-$CO_2$ Eq/yr) and the total emissions from both main and branch roads was 24,152 kt-$CO_2$ Eq/yr in Gyeonggi Province. The ratio of branch roads emission to the total was 0.28 in 2008.