• Title/Summary/Keyword: 정압 제어

Search Result 47, Processing Time 0.026 seconds

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station(I) - Flow Analysis and Mass Flow Rate Verification of Pressure Regulator - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석(I) - 정압기 유동 해석 및 질량 유량 검증 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 2008
  • Gas pressure regulators in pressure regulating station reduce high-pressure gas in a process line to a lower. Gas pressure regulators are not flow control devices, they are used to control delivery pressure only. For the safety of pressure regulating station, it is essential to study flow regime and characteristics of a safety valves that is connected to a pressure regulator. For this, it is necessary to understand flow characteristics and the flow rate of upstream component part such as gas pressure regulators in regulating station. In the present study, numerical analysis of flow characteristics and the mass flow rate of a pressure regulator is conducted under the several inlet, outlet conditions and open rates. Then, the numerical result of the mass flow rate is verified with experimental equation from manufacture of pressure regulator. Consequently, the numerical result is comparatively good agreement with values from experimental equation.

  • PDF

건물의 배수 및 통기시스템: 배관 내부압력의 능동적인 제어

  • Gormly, Michael;Swaffield, John. A.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.9
    • /
    • pp.41-51
    • /
    • 2010
  • 건물의 배수 및 통기시스템에서 나타나는 현상중에 확실한 내용이 아직 밝혀지지 않은 부분이 몇 가지 남아 있다. 이것은 19세기 말엽의 근대 위생공학의 시작 단계에서부터 잘 알려진 사실이다. 건물의 배수 및 통기시스템 운용에 대한 내용은 일반 공학과 특정 유체역학의 범위 내에서 가장 잘 이해할 수 있다. 건물의 배수 및 통기시스템의 운영에 종사했던 초기의 기술진들은 이러한 점을 잘 알고 있었으며 유체역학에 적합하게 응용한 많은 사례를 확인할 수 있었다. 제2차 세계대전이 끝나고 이에 대한 많은 연구가 진행되어 왔으며 특히 유럽에서 시작된 전후 재건 붐을 통해 배수 및 통기시스템의 설계에 좀 더 효율적인 접근이 진척되게 되었다. 이러한 배수시스템의 중심에는 배수관 내부의 오염된 공기가 배수구 또는 위생기구를 통하여 주거 공간으로 유입되는 것을 방지하는 트랩(Water Trap)이 있다. 배수트랩의 주요 기능인 봉수는 일반적으로 깊이가 40 mm에서 50 mm 정도로 위생기구의 종류에 따라 봉수의 깊이는 다소 차이가 있다. 배수관내 공기의 흐름이 중요한 것처럼 트랩의 봉수 메커니즘이 중요하기 때문에 이 메커니즘을 소홀히 여긴다면 안전한 배수시스템의 운영을 기대하기는 어렵다. 배수관 내의 공기의 흐름은 배수에 의해 유입되거나 또는 배출된다. 배수관에서 내부 압력의 불규칙한 변화로 인하여 야기되는 불안정한 배수의 흐름은 트랩의 봉수를 파괴하고 나아가 주거공간으로 오염된 공기가 새어 나갈 수 있는 통로를 제공하게 된다. 관내압력의 천이는 이로 인한 문제가 발생할 가능성이 있는 위치에 그 압력을 완화할 수 있는 장치를 설계단계에 반영하여 적용함으로써 제어할 수 있다. 건물 내부에 상당한 길이의 통기배관을 설치하는 것은 배관의 마찰손실로 인하여 천이 현상을 효과적으로 제어할 수 있는 확실한 방법이 되지는 못한다. 그렇지만 통기밸브를 설치하는 것과 같이 배수관 내로 공기를 공급해주는 유입구를 건물 내부에 분산 설치하는 것이 효율적인 통기방식이 될 수 있고, 정압 천이로 인한 위험을 줄여줄 수 있다. 통기밸브는 정압 발생의 원인이 되지 않으며 단지 정압에 반응하여 더욱 기밀하게 닫히며, 약화된 압력파를 반사할 뿐이다. 고층 건물에서 배수입상관과 평행하게 설치된 통기입상관(Parallel Vent Pipe)의 경우 극히 일부분의 정압 천이 현상을 완화할 수 있다. (통기 배관의 직경이 배수 입상배관과 동일한 경우 대략 1/3 정도임), 그러므로 정압의 천이로 인한 압력 파동은 배수 시스템의 나머지 부분을 통해 전파되어 배수 트랩에 영향을 미치게 된다. 정압의 천이가 예상되는 위치에 정압천이 완화 장치(Positive Air Pressure Transient Alleviation Device)를 사용하면 배관 내부압력의 급격한 상승을 방지하여 연결된 트랩의 봉수를 보호할 수 있다. 이렇게 되면 순간적으로 발생하는 배관내 압력의 급등 현상을 90% 정도까지 완화 시킬 수 있다. 경험적으로 배수시스템에서 배관이 완전하게 막혀 과도한 정압이 발생하는 경우는 거의 없다. 이러한 경우에는 가장 낮은 위치에 있는 배수 트랩의 봉수가 깨지면서 자연스럽게 배수시스템의 압력이 해소되게 된다. 이러한 사례는 통기 방식과 상관없이 발생할 수 있다. 실제와 유사한 시뮬레이션을 통하여 통기 밸브(Air Admittance Valves)는 전면 통기 시스템 (Fully Vented System)에서 최소한 트랩의 봉수 보호용으로 적합한 것이 확인 되었다. 어떤 경우 에는 고층 건물에 더욱 적합하다는 것을 확인할 수 있었다. 부압 해소용으로 통기밸브를 이용하고 정압완화용으로 정압 완화장치(PAPAs: Positive Air Pressure Transient Attenuators)를 사용하는 전면적 능동 제어시스템(Fully Engineered Designed Active Control System)이 사용자에게 육안으로는 확인하지 못하는 기능을 보장하면서 배수 시스템의 안전과 효율성에 대한 효과적인 방법을 제공하고 있다.

  • PDF

Development of a constant pressure feed system using a constant pressure proportional control mode (정압비례제어방식을 적용한 정압급수장치의 개발)

  • 김주명;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1026-1031
    • /
    • 2003
  • Automatic feed pumps are operated and stopped by a pressure switch. Thus, because of repeated operations and stops of the pumps according to fluctuations of water volume, operation with constant rate and pressure is impossible. Moreover, because of repeated running of the pump, keeping up of constant pressure is impossible and damage and energy loss are weak points of the pimps. To make up for defects of an automatic feed pump, this paper designed and made a static pressure feed system which was composed of a feed water control valve, a flow sensor and a control system. The valve device plays an important part in reducing load of pumps by constant water supply regardless of outflow of water. Outflow of water is determined by infrared diode of the flow sensor. The control system is made of a 8 bit micro-processor and the pump was controled by a specific control algorithm. With the constant pressure feed system, discharge pressure was kept at fixed pressure, accurate operations and stops were smoothly accomplished and the pump was operated with constant pressure. Thus, the constant pressure feed system can be considered as an advanced system which made up for the weak points in the current automatic feed systems.

Design of Optimized Fuzzy PI Controller for Constant Pressure Control (정압제어를 위한 최적 Fuzzy PI 제어기 설계)

  • Jo, Se-Hee;Jung, Dae-Hyung;Oh, Sung-Kwun;Kim, Hyun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1950-1951
    • /
    • 2011
  • 본 논문에서는 요구되는 성능을 만족시키는 최적 Fuzzy PI 제어의 정압제어로의 효율적인 적용 및 성능 향상을 위하여 유전자 알고리즘(GA: Genetic Algorithm)을 이용한 제어 설계 방법을 제시 한다. PID제어기는 이해가 쉽고 구조가 간단하여, 실제 구현이 용이하여 공정 산업분야에서 가장 널리 사용되고 있는 제어기 이다. 따라서 단일 입 출력 선형 시스템 에서는 우수한 성능을 보이나 동적 시스템, 고차 시스템 및 수학적 모델 선정이 어려운 시스템에서는 비효율 적이다. 반면, Fuzzy 제어기는 인간의 지식과 경험을 이용한 지적 제어방식으로 IF-THEN형식의 규칙으로부터 제어 입력을 결정하는 병렬형 제어기이다. 이는 과도상태에서 큰 오버슈트 없이 설정치에 도달하게 하는 속응성과 강인성이 좋은 제어기법으로 비선형성이 강하고 불확실하며 복잡한 시스템을 쉽게 제어 할 수 있다는 장점을 지닌다.

  • PDF

Development of Anti-disaster System for Natural Gas Governor Station Using Wire and/or Wireless Communication ($\cdot$무선 데이터 통신을 이용한 천연가스 정압소의 안전방재 시스템 개발)

  • Yoo Hui Ryong;Park Dae Jin;Koo Sung Ja;Park Seoung Soo;Rho Yong Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.17-23
    • /
    • 1999
  • The wire and/or wireless data communication system for anti-disaster system of natural gas governor station was developed. In oder to prevent accidents of governor station, the operator was replaced by RTU(Remote Terminal Unit) which gather and transmit safety situation of governor station. The database and MMI(Man Machine Interface) were also developed to analyze the situation of governor station. The data communication between server and RTU was designed to switch automatically from wire to wireless communication and vice versa when one of them failed communication. We also have developed the patrol car management system which was applied GPS(Global Position System)/GIS(Geometric Information System), and the earthquake detection/transmission system which was adopted three dimension acceleration sensor. When a earthquake may occur, the earthquake detection/transmission system monitors data such as PGA(Peak Ground Acceleration), Sl(Spectrum Intensity) and orders the emergency shutoff valve close immediately.

  • PDF

Numerical Study on Reduction in Frictional Loss for a Sandwitch Type of Pressure Regulator (정압기의 유체력 손실 저감에 대한 수치해석적 연구)

  • Seo, Dong-Kyun;Lee, Jung-Hoon;Hwang, Jung-Ho;Kim, Kwang-Soo;Kim, Kang-Dae;Kim, Dong-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.47-52
    • /
    • 2010
  • The development of energy saving system with pressure regulator has recently been received interests. Since the internal geometry in the pressure regulator is small and complex, the frictional loss in it is critical. In this study, the pressure loss with tip size, tip position, and mass flow was investigated using numerical approaches(CFD). The aimed reduction in pressure were achieved as the ratio of t/T was more than 0.8. In addition, there was no effect of the tip position.

Drag Reduction by Passive Control of Condensation Shock Wave in a Transonic Airfoil (천음속 익형에서 발생하는 응축충격파의 피동제어에 의한 항력 감소)

  • 백승철;최영상;권순범;이충원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.10-10
    • /
    • 1998
  • 천음속 익형에서 발생하는 응축충격파와 경계층의 간섭을 피동제어 하여 항력감소에 대한 연구를 2.5$\times$7$\textrm{cm}^2$ 천음속 풍동에서 수행하였다. 익형표면에 설치한 정압공으로 정압을, 익형후방에 설치한 8개의 Pitot probe로 전압을 동시에 측정하여 충격파를 통한 에너지의 손실과 항력의 변화를 계산하였고, 또한 유동장과 충격파의 형상을 가시화하기 위해 슈리렌 가시화 시스템을 사용하였다. 실험은 NACA 0012 익형에서 기공률 변화에 따른 피동제어의 항력감소 초과를 조사한 다음 NACA 64-018 익형에서는 기공률과 공동의 크기의 변화가 미치는 효과를 연구하였다. 피동제어의 개념은 충격파가 발생하는 하부벽을 다공벽으로 만들고 그 아래를 공동으로 만들면 충격파 후방의 상대적으로 높은 압력이 기류의 일부를 공동으로 자연스럽게 유입시키고 다시 공동에서 낮은 압력의 충격파 상류로 유출시키는 것이다.

  • PDF

Strength Character of the Condition of Consolidated Constant pressure with Improvement One-Dimension Shearing Test and Simple Shearing Test (정압(CD)조건의 개량형 일면전단시험과 단순전단시험에 있어서 강도특성에 관한 연구)

  • Kim, Jae-Young;Ohshima, Akihiko;Takada, Naotoshi;Kim, Dong-Hyun;So, Choong-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.131-136
    • /
    • 2006
  • 일면전단시험은 전단면의 응력을 직접 측정하므로 평면변형시 강도를 파악할 수 있는 등의 많은 장점을 가지고 있으며, 시험조작이 간편하기 때문에 실용적으로도 우수한 것으로 판단된다. 그러나 사질토의 경우에 의한, Dilatancy에 의한 체적변화과정에서 공시체와 전단상자의 주면마찰력이 전단면의 수직 응력을 증감시키기 때문에 구해지는 강도가 과대 또는 과소하게 나타나는 것으로 알려져 있다. 그러나 반력판측에 장착한 하중계를 통해 전단면의 수직응력을 직접 측정 제어하는 형식으로 개선되어 주면마찰력의 영향을 해소하였다. 따라서 본 연구는 반력판측에 하중계를 장착한 개량형 다단식 단순전단시험기를 개발하여 사질토의 정압(CD)조건 전단시험을 수행하여 강도특성과 전단강도에 미치는 영향을 개량형 일면전단시험의 결과와 비교하였다. 그 결과 정압조건의 일면전단시험과 단순전단시험에 의한 강도정수는 조밀한 모래의 경우는 거의 비슷하게 나타나며, 느슨한 모래의 경우는 일면전단이 다소 크게 나타났다. 그리고 단순전단과 일면전단시험에서의 Dilatancy거동에는 큰 차이가 나타나지 않았다.

  • PDF

Basic Characteristics of an Active Controlled Capillary for Compensating the Error Motion of Hydrostatic Guideways (유정압안내면 운동오차보정용 능동제어모세관의 기본특성)

  • 송영찬;박천홍;이후상;김수태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.662-667
    • /
    • 1996
  • For compensating the error motion of hydrostatic guideways, the structure and the theoretical design method of ACC(Active Controlled Capillary) are proposed. The maximum controllable range, micro step response and dynamic characteristics of ACC are analyzed experimentally for verifing the availability. The experimental results showed that by the use of ACC, the error motion within 2.7${\mu}{\textrm}{m}$ of a hydrostatic guideway can be compensated with the resolution of 27nm, 1/100 of uncontolled error, and the frequency band of 5.5Hz. From these results, it Is confirmed that the ACC is very effect to improve the moving accuracy of high or ultra precision hydrostatic guideways.

  • PDF

PRESSURE DROP, RESPIRATION MODELS AND AUTOMATIC AERATION OF ROUGH RICE (벼의 압력손실 및 호흡 모델과 자동통풍에 관한 연구)

  • Chung, J.H.;Verma, Lalit R.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.298-311
    • /
    • 1991
  • 빈 시스템에서 적정 팬을 선정하기 위해서, 빈에서 벼를 건조 혹은 통풍시킬 때 벼의 저항에 의해 발생되는 공기의 압력손실을 예측하는 모델을 개발하였다. 또한 벼의 건물 손실을 예측하기 위하여 벼의 호흡 모델을 개발하였다. 그리고 온도 및 습도 센서들을 이용한 자동계측 시스템을 사용하여 저장된 벼의 상태를 연속적으로 측정, 분석함으로써 벼의 통풍기준을 결정하고 이를 근거로 빈의 자동통풍 시스템을 개발하여 평가하였다. 공기의 정압 손실은 공기의 속도 및 벼의 함수율의 함수로서 나타내어졌으며, 일정 곡물 깊이에서 벼의 함수율이 낮을수록 그 정압손실은 증가하였다. 벼의 호흡에 의해 발생되는 이산화탄소의 양은 저장온도, 벼의 함수율, 저장 기간의 함수로서 나타낼 수 있었다. 벼의 안전 저장을 위해 곡물의 온도 및 함수율, 평형상대습도, 벼의 품질저하지수(deterioration index)에 대한 자동통풍 기준을 결정하였으며 이들을 이용해서 퍼스널 컴퓨터로 팬, 제습기 등의 통풍 장치들을 자동제어하는 자동통풍 시스템을 개발하였다. 이 시스템은 곡물의 상태를 예측, 제어함으로써 14% 이하의 함수율과 4이하의 품질저하지수, 그리고 어떤 균류도 생성시키지 않음으로써 벼를 안전하게 저장할 수 있었다.

  • PDF