• Title/Summary/Keyword: 정상 공명

Search Result 301, Processing Time 0.031 seconds

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF

A Study on the Metabolite Changes in Brain Diseases: 3 Teslar 1H Magnetic Resonance Spectroscopy (뇌질환 대사물질 변화의 고찰; 3 Teslar 수소 자기공명분광법)

  • Eun, Sungjong;Kim, Jeongjae;Yoo, Seungcheol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • The purpose of this study is to know the differences of metabolism in abnormal brain disease using a single-voxel proton MR spectroscopy(1H MRS) Together with five normal volunteers and each five patients with brain diseases, pathologically proved, underwent MRI and 1H MRS. The quantitative results of 1H MRS in adrenoleukodystrophy(ALD), hepatic encephalopathy(HE), and infarction gave unique information on the metabolite changes related with the white matter: the concentration of NAA decreased in all diseases; Cho, mI and Lac increased in ALD; Cho decreased in HE; and ${\beta}{\cdot}{\gamma}$-Glx and Lac increased in infarction. It is concluded that 1H MRS is capable of diagnosing brain diseases by monitoring metabolite changes in vivo that subsequently develope into abnormalities. 1H MRS may be a useful clinical tool for in both diagnosis and prognosis of brain diseases.

Effect of Lumbar Epidural Nerve Block using the Transforamimnal Approach and the Interlaminar Approach on Magnetic Resonance Imaging Findings (추간공 접근법과 추궁간판 접근법을 사용한 요부 경막외 신경차단술이 자기공명영상 소견에 미치는 영향)

  • Hwang, Byeong-Mun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.317-323
    • /
    • 2017
  • This study was conducted to investigate the differences in magnetic resonance imaging (MRI) findings after lumbar epidural nerve block using the transforaminal approach and the interlaminar approach in patients with low back pain. This study was an observational analysis study of abnormal findings of MRI after epidural nerve block. This study included 78 patients who underwent MRI at approximately 24 h after lumbar epidural nerve block at a pain clinic of a university hospital between January 2007 and December 2016. Among patients who received epidural nerve block, 36 used the interlaminar approach and 42 used the transforaminal approach. The incidence of patients with abnormal changes in MRI findings was higher among patients using the interlaminar approach (53%) than those using the transforaminal approach (7%). Abnormal MRI findings included epidural air or fluid, needle tracks, and soft tissue changes, with epidural air being the most frequent abnormal finding (72%). We recommend use of the transforaminal approach to reduce the possibility of misreading or difficulty in interpretation of images of patients who underwent MRI at approximately 24 h after lumbar epidural nerve block. Practitioners should consider the possibility of abnormal findings such as epidural air on MRI in cases of epidural nerve block using the interlaminar approach.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

Anterior Interosseous Nerve Syndrome with Varient Nerve Innervation: A Case Report (해부학적 변이를 가지는 전방골간신경 증후군: 1예 보고)

  • 이준호;나재범;김재수;유진종;이경규;정성훈
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.147-151
    • /
    • 2002
  • Anterior interosseous nerve syndrome is characterized by weakness of the flexor pollicis longus, the flexor digitorum profundus and the pronator quadratus in the presence of normal sensation. Although MR imaging findings of anterior interosseous nerve syndrome has been reported in a few articles, we report herein a case of anterior interosseous nerve syndrome involving more than usual muscles innervated by anterior interosseous nerve, caused by varient nerve innervation.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Functional-Magnetic Resonance Imaging and Transcranial Magnetic Stimulation in a Case of Schizencephaly (뇌열 1예의 기능적 자기공명영상과 경두부 자기자극)

  • 변우목;한봉수;이재교;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.14-19
    • /
    • 2000
  • Purpose : This study was to present the functional brain mapping of both functional magnetic resonance imaging(MRI) and transcranial magnetic stimulation(TMS) in a case of schizencephaly. Materials and methods : A 28-year-old man, who had left hemiplegia and schizencephaly in right cerebral hemisphere, was exacted with both functional MRI and TMS. Motor function of left hand was decreased whereas right hand was within normal limit. For functional MRI, gradient-echo echo planar imaging($TR/TE/{\alpha}$=1.2 sec/90 msec/90) was employed. The paradigm of motor task consisted of repetitive self-paseo hand flexion-extension exercises with 1-2 Hz periods. An image set of 10 slices was repetitively acquired with 15 seconds alternating periods of task performance and rest and total 6 cycles (three ON periods and three OFF periods) were performed. In brain mapping, TMS was performed with the round magnetic stimulator (mean diameter; 90mm). The magnetic stimulation was done with 80% of maximal output. The latency and amplitude of motor evoked potential(MEP)s were obtained from both abductor pollicis brevis(APB) muscles. Results : Functional MRI revealed activation of the left primary motor cortex with flexion-extension exercises of healthy right hand. On the other hand, the left primary motor cortex, left supplementary motor cortex, and left promoter areas were activated with flexion-extension exercises of left hand. In TMS, magnetic evoked potentials were induced in no areas of right cerebral hemisphere, but in 5 areas of left corebral hemisphere from both abductor pollicis brevis. Latency, amplitude, and contour of response of the magnetic evoked potentials in both hands were similar. Conclusion : Functional MRI and TMS in a patient with schizencephaly were successfully used to localize cortical motor function. Ipsilateral motor pathway is thought to be secondary to reinforcement of the corticospinal tract of the ipsilateral motor cortex.

  • PDF

Metabolic Brain Disease : Leukodystrophy (대사성 뇌 질환)

  • 김인원
    • Proceedings of the KSMRM Conference
    • /
    • 1999.04a
    • /
    • pp.99-108
    • /
    • 1999
  • 선천성 대사 이상은 다양한 뇌질환으로 나타낸다. 일반적으로 이 질환들은 하나 또는 둘이상의 대사경로에 대한 생화학적 이상에 원인이 있다. 정상적 생화학적 산물의 결핍이나 비정상적 산물의 축적에 의한 뇌기능 이상에 의해 임상증상이 나타내게 되는데 그 증상은 대개 경기, 경직성, 발육지연 등으로 비특이적이고 영상소견도 마찬가지로 비특이적이다. 대사 이상에 있어서의 신경병변은 일부 뇌백질을 주로 침범하는 경우를 제외하면 대부분 뇌백질을 침범하고 따라서 일반적으로 일차성 뇌백질 질환이 대사성 뇌질환을 일컫는다고 할 수가 있다. 뇌백질 질환은 뇌백질의 구성원중 가장 큰 부분을 차지하는 수초(myelin)를 침범하는 질환을 일컫는다. 중추신경계의 백질은 수초로 싸여있는 축삭(axon)과 선경교세포 (neuroglial cell) 및 혈관 등으로 구성되어 있으며, 이중 대부분을 수초가 차지하고 이 수초로 인하여 정상 뇌백질이 흰색을 나타낸다. 백질내의 신경교세포로는 성상세포 (astrocyte) 와 핍지세포 (oligodendrocyte)가 있으며 신 경교세포의 가장 중요한 기능은 핍지세포에 의한 축삭의 외피화 (ensheathment) 즉, 수초이다. 수초는 핍지세포의 세포질 돌기 (cytoplasmic process)의 일부이며 따라서 수초의 생존과 대사는 핍지세포와 운명을 같이한다. 일반적으로 세포의 생존, 대사와 가장 관련있는 기능은 세포질내에 함유되어 있는 구조물인 소기관(organelle)에 의하여 수행된다. 따라서, 비록 모든 소기관들이 백질 질환을 이르키는데 직접 연관되어 있지는 않더라도 수초의 생존과 대사에는 핍지세포의 소기관들이 매우 중요한 역할을 하게 된다. 세포질내 중요한 소기관으로는 세포 막, 미토콘드리아 (mitochondria), endoplasmic reticulum, Golgi 체, lysosome, peroxisome 그리고 세포질등이 있으며, 이들중에서 lysosomes, peroxisomes, 그리고 미토콘드리아가 특정한 유전성 백질질환에 중요한 역할을 하는 것이 밝혀졌다. 이러한 질환들은 최소한 각 소기관에 의한 질환군으로 분류될 수 있다.

  • PDF

Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla (3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.120-128
    • /
    • 2002
  • To investigate differences between the metabolic ratios of normal controls and brain tumors such as astrocytomas and glioblastoma multiforme (GM) by proton MR spectroscopy (MRS) at 37 high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16$\pm$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of glioblastoma multiforme was significantly higher than that of astrocytomas (P=0.001). Lactate was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF