• Title/Summary/Keyword: 정상 공명

Search Result 303, Processing Time 0.032 seconds

MUSIC THERAPY FOR ADOLESCENTS WITH CONDUCT DISORDER (품행장애 청소년의 음악치료 사례연구)

  • Jhin, Hea-Kyung;Kwon, Hea-Kyung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.11 no.1
    • /
    • pp.110-123
    • /
    • 2000
  • The short-term music therapy was performed for adolescents with conduct disorder admitted to Seoul National Mental Hospital for 3 months from Jun to September, 1998. This case study focused mainly on two female patients who participated regularly in the group music therapy. The music therapy process was divided into three phases;beginning, opening up, and closing. This music therapy session consisted of three parts;hello song as beginning, various musical activities, and sound & movement activity as closing. Free musical improvisation, song discussion, musical monodrama, and sound & movement were the mainly applied techniques. Free improvisation was used to enhance, motivate, identify and contain the adolescents' feelings and ideas. Song discussion was used to convey their thoughts and to support each other. Musical monodrama was used to make them have insights into interpersonal relationships. Sound & movement was used to enhance spontaneity. It made them explore their body and voice as an expressive medium. Throughout three months period of music therapy, patient A's communication skill, socialization, and behavior areas were assessed with improvement. She could use music as a symbolic form and was able to share her feelings about herself and her family. Patient B's self-expression and cognitive areas were assessed with improvement. She became more spontaneous and could verbalize her emotions during the group session. Music as a non-verbal and therefore often a non-threatening medium wherein so much can be expressed provided two female patients an atmosphere where a sense of trust may be regained.

  • PDF

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities (비대성심근증 환자의 이완기능평가: 승모판과 폐정맥 유속을 측정한 위상차 MRI의 이용)

  • Kim, Eun Young;Choe, Yeon Hyeon;Kim, Sung Mok;Lee, Sang-Chol;Chang, Sung-A;Oh, Jae K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.314-322
    • /
    • 2014
  • Purpose: Diastolic dysfunction is a common problem in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to assess the role of MRI in the assessment of diastolic function using mitral valve and pulmonary vein flow velocities in HCM patients. Methods and Results: Phase-contrast MRI (mitral valve and pulmonary vein) and transthoracic echocardiography was successfully performed for 59 HCM patients (44 men and 15 women; mean age, 51 years). Forty-nine patients had a diastolic dysfunction; grade 1 (n = 20), grade 2 (n = 27), and grade 3 (n = 2) using echocardiography, and ten patients had normal diastolic function. The transmitral inflow parameters (E, A, and E/A ratios) obtained by MRI showed positive correlation with the same parameters measured by echocardiography (Pearson's r values were 0.47, 0.60, and 0.75 for E, A, E/A, respectively, all P < 0.001). With the flow information of the pulmonary vein from cardiac MRI, pseudo-normalized pattern (n = 8) could be distinguished from true normal filling pattern (n = 17), and the diastolic function grades by cardiac MRI showed moderate agreement with those of echocardiography (kappa value = 0.45, P < 0.001). Conclusions: Assessment of left ventricle diastolic function is feasible using phase-contrast MRI in HCM patients. Analysis of pulmonary vein flow velocity on MRI is useful for differentiating pseudo-normal from normal diastolic function in HCM patients.

Gaussian Filtering Effects on Brain Tissue-masked Susceptibility Weighted Images to Optimize Voxel-based Analysis (화소 분석의 최적화를 위해 자화감수성 영상에 나타난 뇌조직의 가우시안 필터 효과 연구)

  • Hwang, Eo-Jin;Kim, Min-Ji;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.275-285
    • /
    • 2013
  • Purpose : The objective of this study was to investigate effects of different smoothing kernel sizes on brain tissue-masked susceptibility-weighted images (SWI) obtained from normal elderly subjects using voxel-based analyses. Materials and Methods: Twenty healthy human volunteers (mean $age{\pm}SD$ = $67.8{\pm}6.09$ years, 14 females and 6 males) were studied after informed consent. A fully first-order flow-compensated three-dimensional (3D) gradient-echo sequence ran to obtain axial magnitude and phase images to generate SWI data. In addition, sagittal 3D T1-weighted images were acquired with the magnetization-prepared rapid acquisition of gradient-echo sequence for brain tissue segmentation and imaging registration. Both paramagnetically (PSWI) and diamagnetically (NSWI) phase-masked SWI data were obtained with masking out non-brain tissues. Finally, both tissue-masked PSWI and NSWI data were smoothed using different smoothing kernel sizes that were isotropic 0, 2, 4, and 8 mm Gaussian kernels. The voxel-based comparisons were performed using a paired t-test between PSWI and NSWI for each smoothing kernel size. Results: The significance of comparisons increased with increasing smoothing kernel sizes. Signals from NSWI were greater than those from PSWI. The smoothing kernel size of four was optimal to use voxel-based comparisons. The bilaterally different areas were found on multiple brain regions. Conclusion: The paramagnetic (positive) phase mask led to reduce signals from high susceptibility areas. To minimize partial volume effects and contributions of large vessels, the voxel-based analysis on SWI with masked non-brain components should be utilized.

The Effect of Ginkgo Biloba Extract on Hypoxic Fraction of C3H Mouse Fibrosarcoma (Ginkgo Biloba Extract가 C3H 마우스 섬유육종의 저산소세포 분획에 미치는 영향)

  • Cho Chul Koo;Yi Chun Ja;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.205-214
    • /
    • 1995
  • Purpose : To investigate the effect of Ginkgo biloba extract (GBE) on hypoxic cell fraction and metabolic status in fibrosarcoma (FSa II) of C3H mouse. Materials and Methods : Fibrosarcoma (FSa II) 6 mm in diameter, growing in the right hindleg muscle of C3H mouse was used for estimation of hypoxic cell fraction using comparison of $TCD_{50}$. Radiation was given one hour after administration of GBE (100 mg/kg. i.p.) with or without priming dose of GBE (100 mg/kg, i.p.) given 24 hours earlier. Radiation was also given under air breathing condition or clamp hypoxia without GBE as controls. $^{31}p$ NMR spectroscopy was performed before and one hour after administration of GBE with or without priming dose of GBE. Results : $TCD_{50/120's}$ were 81.7 (77.7-86.0) Gy when irradiated under clamped hypoxia 69.6 (66.8-72.5) Gy under air breathing condition. 67.5 (64.1-71.1) Gy with a single dose of GBE (100 mg/kg) given one hour before irradiation, and 62.2 (59.1-65.5) Gy with two doses of GBE given at 25 hours and one hour before irradiation. The hypoxic cell fractions, estimated from $TCD_{50/120's}$, were $10.6{\%}$ under air breathing condition, $7.2{\%}$ after a single dose of GBE, and $2.7{\%}$ after two doses of GBE. The results of $^{31}P$ NMR spectroscopy were as follow. PCr/Pi ratio was $0.27{\pm}0.04$ and $0.40{\pm}0.04$ before and one hour after a single dose of GBE (p<0.05), respectively, without priming dose and $0.30{\pm}0.02$ and $0.71{\pm}0.04$, respectively, with priming dose (p<0.01). These findings indicate that the metabolic status is slightly improved after a single dose and markedly after repeated administrations. Conclusion : GBE decreases the hypoxic cell fraction and imprvoes the meta bolic status of tumor, probably by increasing the blood flow and delivery of oxygen and nutrients, resulting in increased radiosensitivity of tumor.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

Hepatic Parenchrmal Changes After Percutaneous Injection of Holmium-166 in Rabbit (가토 간내에 Holmium-166 주입 후의 간 실질 변화)

  • 최병인;김명진;박영년;김주희;최병욱
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2001
  • Purpose : To evaluate changes in rabbit liver parenchyma on MR images following percutaneous Holmium-166 injection, and to correlate those changes with histologic findings. Materials and methods. Holmium-166 (10-25 mCi) was percutaneously injected into the liver of rabbit (n=12) under sonographic guidance. MR images were obtained between one to two weeks (acute phasea) after the injection in four rabbits, and between two to four weeks (subacute phase) after the injection in four rabbits. Tissue specimens of these eight rabbits were obtained immediately after MR imaging. Tissue specimens were obtained without MR imaging in four rabbits (between one to two weeks in one rabbit and between three to four weeks in three rabbits). Results : Tissue specimens showed central liquefactive necrosis and peripheral coagulative necrosis containing deposition of small particles and hemorrhage. The peripheral margin of the lesions showed formation of the granulation tissue with fibrosis, which tended to be more prominent in subacute phase. The area of the necrosis tended to correlate with the dose of the radioactive Holmium-166. On MR images, the central portion of the necrosis showed hyperintensity on 72-weighted image, hypointensity on the precontrast T1-weighted images, and no enhancement on the dynamic MR images. The peripheral portion of the necrosis showed hypointensity on T2-weighted images, iso or mild hypointensity on the T1-weighted images, and mild peripheral enhancement on the delayed dynamic MR images. The peripheral margin of the lesion showed hypointensity on both T1- and T1-weighted images with increased enhancement on the delayed phase images of the dynamic MR images. Conclusion : After percutaneous Holmium-166 injection into rabbit liver parenchyma, the central portion showed liquefactive necrosis, the peripheral portion showed coagulative necrosis with granulation, fibrosis, hemorrhage and depostition of small granules. MR imaging may be helpful in evaluation of the histological change of the liver after percutaneous Holmium-166 treatment.

  • PDF

The Age-related Microstructural Changes of the Cortical Gray and White Matter Ratios on T2-, FLAIR and T1- weighted MR Images (T2, FLAIR, T1 강조 MR영상에서 나이에 따른 뇌피질의 회질과 백질의 미세구조 변화)

  • Choi, Sun-Seob;Kim, Whi-Young;Lee, Ki-Nam;Ha, Dong-Ho;Kang, Myong-Jin;Lee, Jin-Hwa;Yoon, Seong-Kuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.32-40
    • /
    • 2011
  • Purpose : The purpose of this study was to investigate the microstructural changes according to aging on the thickness and signal intensity (SI) of the cortical gray matter (GM) and white matter (WM) on the T2-, fluid-attenuated inversion recovery (FLAIR) and T1-weighted MR images in normal subjects. Materials and Methods : The 10, 20, 30, 40, 50, 60, 70, 80 and 90 year age groups of men and women (each 10 individuals) who underwent routine brain MRI, including the T2-, FLAIR and T1-weighted images, were selected for this study. We measured the thickness and the SI of the cortical GM and WM at the postcentral gyrus, which has an even thickness at the level of centrum semiovale, on the axial scans and we calculated the mean values of the thickness ratio of the gray/white matter (TRGW) and the signal intensity ratio of the gray/white matter (SRGW), and we compared the ratios of each age group. Results : On the T2-weighted images, the TRGWs were 0.81 and 0.79 at the age of 10 and they were 0.73 and 0.71 at the age of 90 in the men and women, respectively. So, the GM thickness was decreased more than the WM thickness was with aging. On the FLAIR images, the TRGWs were 1.09 and 1.00 at the age of 10 and they were 1.11 and 0.95 at the age of 70 in the men and women, respectively. On the T1-weighted images, the TRGWs were 0.66 and 0.80 at the age of 10, and the ratio was changed to 0.90 and 0.78 at the age of 90 in the men and women, respectively. On the T2-weighted image, the SRGWs were 1.53 and 1.43 at the age of 10, and they were 1.23 and 1.27 at the age of 90 in the men and women, respectively. On the FLAIR images, the SRGWs were 1.23 and 1.25 at the age of 10 and they were 1.06 and 1.05 at the age of 90 in the men and women, respectively. On the T1-weighted images, the SRGWs were 0.86 and 0.85 at the age of 10, and they were 0.90 and 0.87 at the age of 90 in the men and women, respectively. Conclusion : We suggest that the age-related microstructural changes of the thickness and the SI of the cortical GM and WM on the T2-, FLAIR and T1-weighted images are unique, and so this knowledge will be helpful to differentiate neurodegenerative disease from normal aging of the brain.

Effectiveness of head-up tilt test for the diagnosis of syncope in children and adolescents (소아청소년 실신 환자에서 기립 경사 검사의 유용성)

  • Yu, Ka-Young;Choi, Ji-Hye;Yoo, Chun Ja;Rhee, Kyoung Suk;Joo, Chan Uhng
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.7
    • /
    • pp.798-803
    • /
    • 2009
  • Purpose : We aimed to examine the effectiveness of the head-up tilt test (HUT) for the diagnosis of syncope or presyncope in children and adolescents. Methods : HUT results and clinical features of 160 children and adolescents with syncope or presyncope were studied from May 2003 through March 2008 at the Chonbuk National University Hospital. The children and adolescents were subjected to $70^{\circ}$ HUT for 45 minutes. The testees were divided into 2 groups: group I (children) comprising 39 children in the age range 7-12 years (mean, $10.59{\pm}1.60$ years) and group II (adolescents) comprising 121 adolescents in the age range 13-20 years (mean, $15.93{\pm}2.28$ years). Positive result rates of the HUT and types of hemodynamic response to the test in the 2 groups were compared. Results : Of the 160 testees, 92 (57.5%) showed positive HUT results; they showed 3 patterns of response to tilting. Twelve patients showed a predominantly vasodepressor response; 10 patients showed a cardioinhibitory response; and 70 patients showed a mixed response. The positive result rates were 43.6% (17/39) and 62.0% (75/121) in groups I and II, respectively. Mixed response was the predominant positive hemodynamic response in both the groups. Conclusion : The HUT is a useful diagnostic tool for evaluating the condition of pediatric patients, including adolescents, with syncope. Further, it may be considered as the first step for evaluating the condition of such patients.