• Title/Summary/Keyword: 정상상태 값

Search Result 530, Processing Time 0.025 seconds

Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation (가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석)

  • Kim, Min-Sung;Yoon, Seok-Ho;Baik, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1351-1358
    • /
    • 2011
  • To approximate the threshold of the fault detection and diagnosis (FDD) system, validation of the measurements is mandatory. Naturally, the system shows uncertainties due to measuring sensors - mostly thermocouples or RTDs - and due to repeatability. The uncertainty of a thermocouple comes from natural variation or a drift of the thermocouple measurement. Considering the natural variation behaves like zero-mean white noise, its natural variation can be characterized closely by the steady-state standard deviation. However, residuals between measurements and no-fault references in FDD systems show a statistical distribution with various uncertainties. In this paper, steady-state variations of measurement residuals were investigated by utilizing built-in temperature sensors in a heat pump for the model development and the final application.

Satellite Anomalous Behavior Detection System through Rough-Set and Fuzzy Model (러프집합과 퍼지 모델을 이용한 인공위성의 이상 동작 검출 시스템)

  • Yang, Seung-Eun
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.3
    • /
    • pp.35-40
    • /
    • 2017
  • Out-of-limit (OOL) alarm method that is threshold checking of telemetry value is widely used for the satellites fault diagnosis and health monitoring. However, it requires engineering knowledge and effort to define delicate threshold value and has limitations that anomalous behaviors within the defined limits can't be detected. In this paper, we propose a satellite anomalous behavior detection system through fuzzy model that is composed by important statistical feature selected by rough-set theory. Not pre-defined anomaly is detected because only normal state data is used for fuzzy model. Also, anomalous behavior within the threshold limit is detected by using statistic feature that can be collected without engineering knowledge. The proposed system successfully detected non-ordinary state for battery temperature telemetry.

고선량율 근접치료의 위험도 분석

  • 최진호;이레나;이상훈;이세병;이희석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.57-57
    • /
    • 2003
  • 목적 : 미국 NRC 의 위험도 평가 방법론(NUREG/CR-6642)에 국내에서 시행되는 고선량율 근접치료의 표준입력 자료를 대입하여 고선량율 근접치료시 위험도를 정량적으로 산출하고 그 값을 비교하고자 한다. 대상 및 방법 : 고선량율 근접치료 시스템에 대한 위험도 평가를 위해 국내에서 고선량율 근접치료를 시행하고 있는 17개 의료기관으로부터 방사성동위원소의 설치와 폐기시의 방사능, 선원의 유형, 연간 총 치료회수 등 기초 자료를 수집하였다. 이로부터 방사성동위원소의 평균세기 연간 치료회수 등을 미국 NRC의 위험도 평가 방법론의 데이터베이스에 입력하여 고선량율 근접치료의 직무별, 피폭인의 종류, 정상상태와 사고 등의 형태에 따라 그 위험도를 구하였다. 결과 : 국내 고선량율 근접치료의 위험도는 미국 NRC의 위험도 평가 방법론에 따른 데이터베이스의 입력 결과 일반인의 정상상태와 사고 그리고 방사선종사자의 정상상태와 사고 시에 따라 그 위험도가 1.52-01, 2.96-03, 8.64-01, 3.32-02 rem/yr로 산출되었고 그 값을 미국 NRC의 값과 비교하였다. 결론 : 고선량율 근접치료 시 미국 NRC의 위험도 결과보다는 국내의 경우 수배 정도 높게 계산되었고 일반인과 방사선종사자, 정상상태와 사고, 직무별 패턴 등은 동일한 것으로 간주된다.

  • PDF

An Investigation of Transient Responses of CANDU-6 PHTS Using DSNP (DSNP Language를 이용한 CANDU-6 PHTS 과도상태)

  • 전용준;박지원;오세기;정근모
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.103-114
    • /
    • 1995
  • 본 연구는 원자력발전소용 시뮬레이션 언어인 DSNP(Dynamic Simulator for Nuclear Power-plants)언어를 이용하여 CANDU-6 발전소 운전 모사 프로그램을 구성함으로써 핵심계통인 1차 냉각재 계통(PHTS)과 2차 계통 일부가 정상 및 과도조건에서 보일 수 있는 운전 상태를 연구하였다. DSNP 프로그램은 원자로심과 증기발생기에서의 열전달 모델, 열수송계통 펌프 모델 및 가압기 열수력 모델을 포함하고 있으며, 파이프(pipe)라는 단위 구성체를 이용하여 1차 냉각재계통을 노드화하여 계통 모사가 실현된다. 정상상태 100% 전출력 운전시 대표적인 운전변수를 기준으로 DSNP 결과와 CANDU-6 발전소 설계치를 비교해 본 결과 서로 매우 근사한 값을 나타내었으며, 이는 과도상태 모사의 초기조건으로 합당한 것으로 판단된다. 본 연구에서 선택된 과도상태 모사시 DSNP 프로그램은 매우 안정된 최종정상상태를 얻음에 따라 원자로의 기계 물리학적 변화를 합리적으로 모사하고 있음을 알 수 있었다. 최종 정상상태 회귀 이전의 동적 거동을 원자로 설계자료인 예비 안전성 평가 보고서(PSAR)와 비교한 결과 단기적 거동은 PSAR 결과와 다소 다른 점이 있었으나 전체적으로 합리적인 운전변수 값을 얻을 수 있었다. 단기적 거동에 대한 입증은 원자로 운전 자료를 통하여 가능할 것으로 사료된다. 이상과 같이 본 연구를 통해 구성한 DSNP 프로그램은 보완 및 개선의 여지가 있으나 현재의 수준으로도 CANDU-6 발전소의 일부 과도상태 모사가 가능한 것으로 판단된다.

  • PDF

Sensorless Vector Control of Induction Motor using Speed Observer in Steady State (정상상태에서 속도관측기를 이용한 유도전동기 센서리스 벡터제어)

  • 이수원;전칠환;이성룡
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1142-1146
    • /
    • 2004
  • This paper describes sensorless vector control of induction motor using speed observer in steady state. In sensorless vector control of induction motor, the proposed speed observer is consists of q-axis voltage of controller and real current. This paper investigates the speed characteristics when a step change of speed reference. This is verified by simulations and experimental results.

Classification of Respiratory States based on Visual Information using Deep Learning (심층학습을 이용한 영상정보 기반 호흡신호 분류)

  • Song, Joohyun;Lee, Deokwoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.296-302
    • /
    • 2021
  • This paper proposes an approach to the classification of respiratory states of humans based on visual information. An ultra-wide-band radar sensor acquired respiration signals, and the respiratory states were classified based on two-dimensional (2D) images instead of one-dimensional (1D) vectors. The 1D vector-based classification of respiratory states has limitations in cases of various types of normal respiration. The deep neural network model was employed for the classification, and the model learned the 2D images of respiration signals. Conventional classification methods use the value of the quantified respiration values or a variation of them based on regression or deep learning techniques. This paper used 2D images of the respiration signals, and the accuracy of the classification showed a 10% improvement compared to the method based on a 1D vector representation of the respiration signals. In the classification experiment, the respiration states were categorized into three classes, normal-1, normal-2, and abnormal respiration.

Steady-state analysis of LLC resonant converter for optimum design (LLC 공진형 컨버터의 최적 설계를 위한 정상상태 해석)

  • Nam Won-Seok;Han Sang-Kyu;Roh Chung-Wook;Hong Sung-Soo;SaKong Suk-Chin;Kim Chong-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.375-377
    • /
    • 2006
  • 본 논문에서는 LLC 공진형 컨버터의 최적 설계를 위해, ZVS 영역에서 동작하는 LLC 공진형 컨버터의 최악의 상태에 대한 정상 상태 해석을 하였다. LLC 공진형 컨버터의 최악의 상태는 최소 입력 전압, 최대 부하 전류일 때 얻을 수 있는 최대 전압 이득을 의미한다. 설계 변수는 스위칭 주파수 범위와 공진 인덕터 비율로서, 각 설계 변수의 변화에 따른 공진 탱크 설계 값, 최악의 상태 출력 전압 그리고 최대 공진 캐패시터 전압을 보여주는 '최악의 조건 설계 표'를 나타내었으며, 설계된 특정 공진 탱크 값에 대한 시뮬레이션 결과와 실험 결과를 보였다.

  • PDF

The Transient Responses of CANDU-6 Stepback Operaton (CANDU-6 단계감발 운전시 과도상태 반응에 관한 연구)

  • 전용준;박지원;오세기;정근모
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.150-154
    • /
    • 1994
  • 본 연구는 원자력발전소용 시뮬레이션 언어인 DSNP 언어를 이용하여 CANDU-6 발전소 운전 모사 프로그램을 구성함으로써 핵심계통인 1차냉각재 계통(PHTS)과 2차 계통 일부가 정상 및 과도조건에서 보일 수 있는 운전 상태를 연구하였다. DSNP 프로그램은 원자로심과 증기발생기에서의 열전달 모델, 열수송계통 펌프 모델 및 가압기 열수력 모델을 포함하고 있으며, 파이프(pipe)라는 단위 구성체를 이용하여 1차 냉각재계통을 노드화하여 계통 모사가 실현된다. 정상상태 100% 전출력 운전시 대표적인 운전변수를 기준으로 DSNP 결과와 CANDU-6 발전소 설계치를 비교해본 결과 서로 매우 근사한 값을 나타내었으며, 이는 과도상태 모사의 초기조건으로 합당한 것으로 판단된다. 본 연구에서 선택된 과도상태 모사시 DSNP 프로그램은 매우 안정된 '최종정상상태'를 얻음에 따라 원자로의 기계 물리학적 변화를 합리적으로 모사하고 있음을 알 수 있었다. CANDU-6 단계감발 운전시 동적 거동을 원자로 설계자료인 '예비 안전성 평가 보고서(PSAR)'와 비교한 결과 단기적 거동은 PSAR 결과와 다소 다른 점이 있었으나 전체적으로 합리적인 운전변수 값을 얻을 수 있었다. 단기적 거동에 대한 입증은 원자로 운전자료를 통하여 가능할 것으로 사료된다. 이상과 같이 본 연구를 통해 구성한 DSNP 프로그램은 보완 및 개선의 여지가 있으나 현재의 수준으로도 CANDU-6 발전소의 일부 과도상태 모사가 가능한 것으로 판단된다

  • PDF

A Necessary and Sufficient Condition for Multiplicity of Steady-State Solutions of Point-Kinetics Reactor Feedback Svstems (점동특성시스템이 다중의 정상상태해를 갖기 위한 필요충분조건)

  • Yang, Chae-Yong
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.463-469
    • /
    • 1995
  • The point-kinetics reactor system which is subject to feedback effects may have multiple steady-state solutions for some operating conditions. A necessary and sufficient condition for multiple steady-state solutions of the point-kinetics reactor feedback system for an external input reactivity is obtained through their theoretical approach. If and only if the steady-state feedback reactivity of the reactor system is not strictly monotonic on some values of the feedback variables, then the reactor system has multiple steady-state solutions for the equilibrium operating conditions corresponding to the values of the feedback variables. Also, if and only if the steady--state feedback reactivity is strictly monotonic on all the feedback variables, then the reactor system has only one steady-state solution for all the operating conditions.

  • PDF

The Verification Test for the Primary Piping System of Nuclear Power Plant (원자력 발전소 1차계통 배관 건전성 평가)

  • Lee, Hyun;Kim, Yearn-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.318-321
    • /
    • 1995
  • 원자력 발전소의 안전성 보장 및 신뢰성 향상을 위하여 시운전 단계에서 원자력 발전소내 안전등급에 해당하는 배관계통의 상태 확인을 위하여 각종시험을 하도록 되어있다. 특히 새로운 설계기념, 크기 또는 용량을 갖는 원자로 모델에 대해서는 필수적으로 건전성 평가를 하게 되었다. 이를 위해 발전소 건설기간에 시행하는 고온 기능시험 중에 원자로 주변 주요 시스템인 원자로 냉각재 루프 계통에 대한 건전성 확인을 위해 압전형 고온 가속도 센서를 이용하여 정상운전상태의 진동을 측정하여 시스템 진동거동을 규명하였다. 배관시스템의 일상운전상태는 유체의 흐름과 기기운전이 일정한 정상상태와 펌프의 기동 또는 정지 및 밸브의 급격한 개폐등으로 발생하는 과도상태로 나눌 수 있다. 따라서 두 가지 상태의 진동을 측정해야 한다. 배관계통은 정상운전 상태로 설계수명을 유지할 수 있어야 하므로 정상진도잉 최소화 되어야 한다. 진동 평가기준은 배관재질의 응력(S/N 커브) 곡선을 참조하여 설계수명내에 손상이 일어나지 않도록 재료의 허용응력을 산정하고 이를 진동변위로 환산하여 정한 것이며 이 값에 측정 데이타를 비교하여 1차계통 배관의 건전성을 확인하였다.

  • PDF