• Title/Summary/Keyword: 정밀 연삭

Search Result 477, Processing Time 0.022 seconds

SEM and PV Properties of WC Core Surface with DLC Coating (초경합금(WC) 코어면의 Re-Ir 코팅에 따른 표면 조도 특성)

  • Lee, Ho-Shik;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.828-829
    • /
    • 2010
  • Rhenium-Iridium(Re-Ir) thin films were deposited onto the tungsten carbide(WC) molding core by sputtering system. The Re-Ir thin films on tungsten carbide molding core were analyzed by scanning electron microscope(SEM) and surface roughness. The Re-Ir coating technique has been intensive efforts in the field of coating process because the coating technique and process have been their feature, like hardness, high elasticity, adrasion resistance and mechanical stability and also have been applied widely the industrial and biomedical areas. In this report, tungsten carbide(WC) molding core was manufactures using high performance precision machining and the efforts of Re-Ir coating on the surface roughness.

  • PDF

Fretting Wear Test of Inconel 690 Tubes Employing Piezoelectric Actuator (압전 구동기를 이용한 인코넬 690 튜브의 프레팅 마멸시험)

  • Chung, Il-Sup;Lee, Myung-Ho;Park, Ki-Hong;Lee, Jung-Hoon;Kwon, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.101-108
    • /
    • 2009
  • A fretting wear test rig for dry ambient condition, which employs a piezoelectric actuator, has been developed. It is driven and loaded in a very simple manner with acceptable experimental accuracy. By using the rig, Inconel 690 tube has been tested under the normal load of 10 and 15N with sliding amplitude of less than $100{\mu}m$ during $10^6$cycles. The wear resistance of the material has been characterized in terms of the wear coefficient based on the work rate model. SEM micrographs show the complex structures of the scars, which consist of risen peaks, plate-type thin layers and locally exposed bare surfaces. The cracks spread over the layers give clue to the fretting wear mechanism of the material.

A COMPARATIVE STUDY ON THE FIT IN PROSTHESIS USING PREMADE GOLD CYLINDER AND PLASTIC CYLINDER (정밀 연삭된 지대주와 합성수지 지대주를 이용한 보철물의 적합도에 대한 비교 연구)

  • Jung, Seon-Hee;Ma, Jang-Seon;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.825-834
    • /
    • 1999
  • Recently, various implant cylinders were supplied. especially received gold cylinders, cast cylinders produced from premade gold and plastic cylinders and plastic cylinders. This study measured and compared precise fit produced when using conventional gold and plastic cylinders. The comparative fit of lapped and non-lapped castings made from plastic pattern was examined. The implant/abutment interface fit was evaluated by scanning electron microscopy(SEM) for each of four cylinders. The following results were obtained: 1. The case of plastic cylinder showed $9.67{\pm}1.50{\mu}m$ gap when Steri-Oss fixture was connected. 2. The case of lapped casting made from plastic cylinder showed $3.01{\pm}2.81{\mu}m$ gap when Steri-Oss fixture was connected. 3 The case of gold/plastic cylinder showed $9.80{\pm}1.68{\mu}m$ gap when Steri-Oss fixture was connected. 4. The case of gold cylinder showed ${5.47{\pm}2.43\mu}m$ gap when Steri-Oss fixture was connected. 5. In case of each cylinder which was connected with Steri-Oss fixture, the size of gap was showed less in the order of the case of gold/plastic cylinder, the case of plastic cylinder, the case of gold cylinder and the case of lapped casting made from plastic cylinder As results of this study, the use of premade gold cylinder offers an advantage over plastic pat-terns in precise fit. When plastic patterns are used, polishing of implant cylinder components should provide precise fit.

  • PDF

Molding and Optical Evaluation of Aspheric Glass Lenses for Camera Phone Module (카메라폰 모듈용 비구면 Glass렌즈의 성형 및 광학특성 평가)

  • Kim, Hye-Jeong;Cha, Du-Hwan;Kim, Jeong-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.3
    • /
    • pp.124-131
    • /
    • 2007
  • Aspheric glass lenses was fabricated by glass molding press(GMP), which is a plano-aspheric convox shape and intended for use as an optical design of 3 megapixel and 2.5 magnifications zoom in a camera phone module. Transcription ratio of form accuracy (PV) as well as resolution properties was measured for evaluation the molded lens. Form accuracy (PV) of the mold surface was $0.127\;{\mu}m$ in an aspheric and $0.168\;{\mu}m$ in a plano, in case of the molded lens it shows $0.205\;{\mu}m$ and $0.223\;{\mu}m$, respectively. Resolution of the molded lens was measured as a MTF[Contrast]. The molded lens shows contrast of 32.9% at 80 1p/mm and the value is similar with contrast of 33% obtained simulation.

  • PDF

The Effect of Types of Abutment and Dynamic Loading on Microgap between Implant Fixture and Abutment (임플란트 지대주 종류와 동적하중이 고정체와 지대주의 미세간극에 미치는 영향)

  • Oh, Byung-Doo;Choi, Yu-Sung;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.389-403
    • /
    • 2010
  • Titanium and gold-alloy abutments have been used for a long-time in the clinical situations, but the use of zirconia abutments also increased. This study was designed to compare and evaluate the microgap differences according to types of abutment and dynamic loading. Titanium abutment, zirconia abutment and gold-alloy abutment (UCLA plastic) were connected into titanium implants of external hexagonal structure US II ${\phi}$ $3.75{\times}11.5$ mm (Osstem Co., Seoul, Korea) with the tightening torque of 30 Ncm. A sine type dynamic loading of 25-250 N and $30^{\circ}$ inclination from long axis was applied for $10^5$ times. Using the SEM both before and after the loadings, implant-abutment interfaces were analyzed on the labial, palatal, mesial and distal surface. The microgaps before and after the loading were compared, no statistically significant difference was observed caused by the dynamic loading on the labial, palatal, mesial or distal surface. Statistically significant difference was observed between UCLA and titanium group and between UCLA and zirconia group on both before and after the loading(p<0.05). No statistically significant difference was found between titanium and zirconia group. Loadings for $10^5$ times did not show significant effect to the microgaps between implants and abutments.

Crystal Growth of rutiles doped with Impurity Ions by Floating Zone Method (부유대용융법에 의한 불순이온 주입된 $TiO_2$단결정 성장 연구)

  • 이성영;유영문;김병호
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 1999.04a
    • /
    • pp.1-1
    • /
    • 1999
  • 부유대용융법에 의하여 불순이온의 종류와 각 이온의 주입 농도를 달리하는 Rutile 단결정을 성장하였다. 성장된 결정으로부터 제조한 박편시료를 이용하여 결정결함과 광투과도에 미치는 각 불순이온의 영향을 조사하였다. 결정성장용 주원료로 99.99%의 TiO2를 사용하고, 불순이온 주입을 위한 원료로서 99.99%의 Al2O3, H3BO3, Ga2O3, Sc2O3, V2O5, Fe2O3, ZrO2, Er2O3, Cr2O3를 각각 사용하였다. 불순이온의 종류에 따르는 영향을 조사하기 위하여 TiO2 99.8 atomic%-불순이온 0.2atomic%의 조성이 되도록 각 이온별로 원료를 정밀하게 평량하고 균일 혼합하였다. 불순 이온의 첨가량에 따르는 영향을 조사하기 위하여 Al2O3는 각각 pure, 0.2, 0.4, 0.6 atomic%를, Cr2O3는 pure, 0.003, 0.05, 0.2 atomic%를 각각 치환하여 원료를 조합하였다. 균일 혼합된 원료를 직경 8mm의 고무 튜브에 넣고 CIP(Cold Isostatic Press0에서 2000kg/$\textrm{cm}^2$의 압력으로 성형한 후 150$0^{\circ}C$에서 1시간 소결함으로서 결정성장용 다결정 원료를 합성하였다. 합성된 다결정을 double ellipsoidal mirror 내에 설치하고,halogen lamp로 가열하여 원료의 한쪽 끝을 용융한 다음, 20rpm의 회전속도, 3-5mm/hr의 성장속도로 하는 유속 1$\ell$/min의 O2 분위기속에서 부유대용융법에 의하여 결정을 성장하였다. 성장된 결정을 성장축에 수직한 방향으로 각각 절단, 연삭, 연마한 박편을 이용하여 편광하에서 low-angle grain boundaries 및 기타의 결정결함을 관찰하였으며, 0.3$\mu\textrm{m}$~0.8$\mu\textrm{m}$ 범위 및 0.6$\mu\textrm{m}$~3.4$\mu\textrm{m}$ 범위에서의 투과 및 흡수 스펙트럼을 측정하였다. 결정 성장 결과 B3+, Er3+, Cr3+ 이온은 Ti4+ 이온과 이온의 크기 차이가 심하여 결정의 정상적인 성장을 방해하는 물성을 나타냈고, V5+, Cr3+ 이온은 흑색의 결정, Fe3+ 이온은 적갈색의 결정으로 성장되었다. Al3+, Zr4+, Al3+의 순서로 투과도가 높아지는 것이 관찰되었다. 불순이온의 농도에 따른 영향으로서 Al3+ 이온의 경우 주입농도가 높아질수록 low angle boundary와 oxygen deficiency가 감소하였고, 투과율은 조금 감소하거나 큰 차이가 없는 것으로 나타났다. 반면에 Cr3+ 이온을 주입한 경우 0.003 atomic%에서 최적의 물성을 보였으며, 주입농도가 높아질수록 결정성장이 어려워지고 광의 투과도가 급격히 저하되었다.

  • PDF

A Comparative Study on Power Tool Manufacturers' Products Spec. and Design Development Features - By the Case Study on BOSCH, BLACK&DECKER and KEYANG Electrics- (전동공구 회사의 제품사양별 디자인개발특성 비교연구 -보슈(BOSCH), 블랙앤데커(BLACK&DECKER), 계양전기 사례를 중심으로 -)

  • 채승진
    • Archives of design research
    • /
    • v.17 no.1
    • /
    • pp.383-392
    • /
    • 2004
  • The power tools is the product using working power generated by electric motor. Many companies are manufacturing numerous devices. Main features of tools are included various assembled products, small, light and solid and durable enough to match several standards. Fundamental requirements for the product is excellent performance and convenience for use. The quality of them depends on the equipped motor'(s) capability, accuracy of gear and endurance against worn-out. By adapting the state-of-the-art parts, they could be used in the place from home to heavy industry broadly. They can be classified electronic drills, grinders, saws and sanders families for the household appliances. For industrial tools, bore drill, grinder, polisher, and driver drill are classified as special and high priced group. This study presents the strategy of power tool development of BOSCH, BLACK&DECKER and KEYANG. Their products were analyzed in terms of product line and product mix concept. Then they are examined by design elements, such as color, shape and material for housing. As an analysis method, the image scale parameter and criteria were applied to each company's product.

  • PDF