• Title/Summary/Keyword: 정맥 유출

Search Result 40, Processing Time 0.026 seconds

Arteriovenous Fistula Formation with Prosthetic Graft Using the Vena Comitantes as a Venous Outflow (동반정맥을 정맥유출로 이용한 인조혈관 동정맥루 조성술)

  • Lee, Gun;Lim, Chang-Young;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.41-45
    • /
    • 2009
  • Background: Arteriovenous fistula formation is not always easy to perform in hemodialysis patients because of poor preservation of veins due to repeated venipuncture and cannulation. We analyzed the patency rate and complications of prosthetic arteriovenous fistulas using the vena comitantes as a venous outflow in the antecubital fossa, which are protected from venipuncture. Material and Method: Between January 2006 and June 2008, 12 patients underwent prosthetic arteriovenous fistula formation using the vena comitantes as a venous outflow. Arterial inflow was via the brachial artery and the graft was placed in a loop fashion. The male-to-female ratio was 7 : 5 and the mean age was $59{\pm}14$ years. Six patients had diabetes mellitus and 10 patients had hypertension. Result: There were no complications, such as a graft infection or bleeding. Five patients showed postoperative stenosis at an average of 3 months. The primary patency rate was 75.0, 65.6, and 52.2% at 3, 6, and 12 months, respectively. All the patients with stenosis were able to continue hemodialysis after intervention therapy. The secondary patency rate was 100% at 12 months. Conclusion: Creation of a prosthetic arteriovenous fistula using uninjured vena comitantes resulted in a good patency rate and this vein may become a substitute for inappropriate superficial veins.

Transvaginal Direct Puncture and Ethanol Sclerotherapy for Cervicovaginal Venous Malformations: A Case Report and Literature Review (자궁경부 및 질에 발생한 정맥기형에 대한 질 경유 직접 천자 및 에탄올 경화요법: 증례 보고 및 문헌 고찰)

  • Gu Seong Jeong;Suk Hyun Bae;Young Soo Do;Hyoung Nam Lee;Sang Joon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.688-692
    • /
    • 2021
  • Cervicovaginal venous malformations are extremely rare. Sclerotherapy is proven to be effective for superficial venous malformations but not for venous malformations in the lower genital tract of female. A 52-year-old female presented with intermittent vaginal bleeding. The amount of vaginal bleeding gradually increased over 3 months. Contrast-enhanced pelvis CT showed several phleboliths and dilated vessels, but pelvic angiography showed no early draining veins, nidus, or feeding artery. We performed transvaginal direct puncture and ethanol sclerotherapy rather than surgical treatment because she wanted to preserve the uterus. After four sessions of sclerotherapy, she had significantly decreased vaginal bleeding without complications. Here, we report the first case of cervicovaginal venous malformations successfully treated with transvaginal direct puncture and ethanol sclerotherapy.

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF

Resurfacing of the Open Wound of the Hand With Free Arterialized Venous Flap (유리 동맥화 정맥피판을 이용한 수부의 재피복술)

  • Woo, Sang-Hyun;Kim, Seong-Eon;Jeong, Jae-Ho;Lee, Kyung-Ho;Seul, Jung-Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.303-313
    • /
    • 1994
  • Since introduction of venous flap in 1980, many experimental studies and clinical applications of various kinds of venous flaps were reported. Venous flap has the following advantages: (1) nonbulky and goo-quality of flap (2) long & large vascular pedicle (3) easy & rapid elevation of flap (4) no sacrifice of major arteries (5) a single operarive field. But, we also have some disadvantages of difficult handling of the pliable veins and the uncertainty of flap survival. For the better result we had to design the size of the flap larger than that of defect and increase the number of draining vein to reduce the postoperative edema of the flap. We have treated the defects of soft tissue of the hand using free arterialized venous flap from the flexor aspect of the forearm & had an excellent results.

  • PDF

Clinical Results from Single-Fraction Stereotactic Radiosurgery (SRS) of Brain Arteriovenous Malformation: Single Center Experience (뇌동정맥기형에서 선형가속기를 이용한 방사선 수술 후의 임상적 결과)

  • Lim, Soo-Mee;Lee, Re-Na;Suh, Hyun-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.274-280
    • /
    • 2010
  • The purpose of this study was to analyze the effect of single-fraction stereotactic radiosurgery (SRS) for the treatment of 15 cases of cerebral arteriovenous malformations (AVMs). Between 2002 and 2009, of the 25 patients who had SRS for the treatment of cerebral AVM, 15 patients (6 men, 9 women) taken a digital subtraction angiography (DSA) over 12 months after SRS were included. We retrospectively evaluated the size, location, hemorrhage of nidus, angiographic changes on follow-up on the MR angiography and DSA, and clinical complications during follow-up periods. At a median follow-up of 24 months (range 12-89), complete obliteration of nidus was observed in all patients (100%) while residual draining veins was observed in 3 patients (20%). There was no clinical complication during the follow-up period except seizure in 1 patient. The mean nidus volume was 4.7cc (0.5~11.7 cc, SD 3.7 cc). The locations of nidus were in cerebral hemisphere in 11 patients, cerebellum in 2 patients, basal ganglia in 1 patient, and pons in 1 patient respectively. 9 cases were hemorrhagic, and 6 cases were non-hemorrhagic AVMs. The SRS with LINAC is a safe and effective treatment for cerebral AVMs when the follow up period is over 4 years. However, it is recommended to continue to follow up until the draining vein on arterial phase of follow up DSA disappears completely.

Factors Influencing on Early Patency Rate of Autogenous Arteriovenous Fistula for Hemodialysis (혈액투석을 위한 자가 동정맥루 수술에 있어서 조기개존율에 영향을 미치는 요인)

  • 민선경;한재진;원태희;안재호
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.342-348
    • /
    • 2004
  • It is very important for hemodialysis in patients with end stage renal disease to obtain vascular access that resists repeated punctures and maintains adequate blood flow. This study was designed to indentify factors that may influence early patency rate of autogenous arteriovenous fistula. Material and Method: 49 cases in 47 patients who underwent radiocephalic fistula formation in our hospital from June 2002 through May 2003 were reviewed and analyzed. Result: The early patency rate was 79.6%. Age, sex, hypertension, and diabetes mellitus were not significant factors for patency. Body mass index and duration of hypertension and diabetes did not influence the early results either. Cephalic vein diameter measured preoperatively and blood flow at radio-cephalic fistula were significantly positive correlative factors. Groups with the vein diameter less than 2.7mm, or with the blood flow less than 100 mL/min had significantly lower early patency rate than the other groups. Conclusion: To improve early patency rate of radiocephalic fistula, large sized cephalic vein should be selected and if the intraoperative flow at radiocephalic fistula is less than 100 mL/min, another arteriovenous fistula formation should be considered.

May-Thurner Syndrome with Deep Vein Trombosis after Total Knee Arthroplasty (인공 슬관절 전치환술 후 발생한 메이-터너 증후군 및 심부정맥 혈전증)

  • Lee, Hwa-Sung;Kim, Yong-Woo;Jung, Se-Hoon;Lee, Se-Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.4
    • /
    • pp.343-347
    • /
    • 2020
  • May-Thurner syndrome (MTS), also known as iliac vein compression syndrome, is a condition, in which compression of the common venous outflow tract of the left lower extremity can cause discomfort, swelling, pain or blood clots in the iliofemoral veins. The problem is due to left common iliac vein compression by the overlying right common iliac artery. This paper describes the case of a 75-year-old female with MTS after performing right total knee replacement arthroplasty. The authors diagnosed MTS through intravenous angiography and angiographic computed tomography on swelling and pain of the left lower extremities after performing right total knee replacement arthroplasty. The thrombus was removed using a thrombolytic agent and mechanical thrombectomy, and an intravenous stent then inserted after angioplasty. No case of MTS after performing total knee replacement arthroplasty has been reported in Korea. Therefore, this case is reported along with review of the relevant literature.

Prevalence and Management of Venous Rupture Following Percutaneous Transluminal Angioplasty in Dysfunctional Arteriovenous Access: A Comparative Study of Primary Patency Rates with Non-Ruptured Access Circuits (동정맥루 기능 부전에서 경피적 혈관성형술 후 발생한 정맥 파열의 유병률 및 관리: 파열되지 않은 혈관과의 일차 개통 비교 연구)

  • Yoon Soo Park;Seung Boo Yang;Chae Hoon Kang;Dong Erk Goo
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.4
    • /
    • pp.746-753
    • /
    • 2024
  • Purpose This study aims to evaluate the incidence and management of venous ruptures after percutaneous transluminal angioplasty (PTA) for dysfunctional arteriovenous (AV) access. Materials and Methods From January 1998 to December 2015, 13506 PTA, mechanical thrombectomy, and thrombolysis procedures were performed in 6732 patients. The venous rupture rate following PTA was obtained, and access circuit primary patency (ACPP) was compared according to the etiology (PTA, thrombotic occlusion, and treatment type) of the venous rupture present. Results Venous rupture developed in 604 of the 13506 procedures. Venous ruptures were more frequent in female, AV graft cases, and in cases accompanied by thrombosis. Balloon tamponade was performed in 604 rupture cases, and stents were deployed in 119 cases where contrast extravasation and flow stasis persisted. ACPP was significantly better in the non-ruptured AV access circuits than in the ruptured group. However, AV access type and thrombosis was not associated with primary patency. In ruptured cases, ACPP is 8.4 months for prolonged balloon tamponade and 11.2 months for bare-metal stent insertion, showing statistically significant difference. Conclusion Balloon tamponade and bare-metal stent placement are effective treatment for PTA-induced venous ruptures. In particular, stent placement showed a similar ACPP to that of non-ruptured AV access circuits.

Detection for Contrast Media Extravasation using Bolus Tracking Systems of CT (CT Bolus Tracking System을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.137-142
    • /
    • 2016
  • When injecting intravenously of CT inspection, the effusion of the contrast meium can induce the tissue damage with the blood vessel outside. We detect extravasation which is generated in the course where we inject the contrast medium into the blood vessel. And we use the bolus tracking system for the detection of that. By using MPR and VR images, moreover we detected the extravasation in order to prevent the tissue damage. In order to detect the effusion of the contrast medium, we used 16-MDCT and 64-MDCT. Three dimensional images about the outflow of the blood vessel can provide the treatment information which is important in the patient treatment. Moreover we applied the image processing technique in order to improve sharpness between contrast media and organization. And sharpness and contrast was improved.

Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance (전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상)

  • Kweon Dae Cheol;Kim Tae Hyung;Yang Sung Hwan;Yoo Beong Gyu;Kim Myeong Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • We report a case of an accidental extravasation of contrast material. A large-volume extravasation occurred in an adult during spiral contrast-enhanced CT. The amount of contrast material extravasated was 47 ml. The patient had a swelling of the dorsum right hand. The extravasation injury site was determined by CT scanning. The extavasation case was examined using five separate display techniques: axial, multi planar reformation (MPR), maximum intensity projection (MIP), volume rendering, and shaded-surfaced display (SSD). This paper introduces extravasation with the CT and the three-dimensional appearance.

  • PDF