• Title/Summary/Keyword: 정로

Search Result 55,000, Processing Time 0.067 seconds

Study on the Improvement of Stow Net Fishing Technique and the Enlargement of Fishing Ground to the Distant Waters - 3 . Field Experiment on the Efficiency of Newly Designed Net and the Stern Operation System (안강망어법의 개량과 어장의 원해로의 확대를 위한 연구 - 3 . 시험어구의 전개성능과 선미식 어업방법에 관한 해상시험 -)

  • 이병기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.2
    • /
    • pp.75-81
    • /
    • 1989
  • In this paper, the authors describe on the field experiment of the newly designed actual stow net, standing on the result of the model experiment to examine the performance of the conventional net and the newly designed net, presented in two previous reports of this series. Concurrently the additional experiment to find out the possibility of changing of operating system from the side to the stern was carried out. 1. Fundamental shape of the experimented net was 20 times aslarge asthe newly designed model net. Performance of the net was detected by using two ultrasonic echo sounders: one was set downward at the top-most spreader of the shearing device to detect the opening height of the device from the sea bed, and the other sidewise at the starboard top-most spreader to detect the top-most opening width of the devices. Opening height of the newly designed net showed about 3m smaller than the conventional net at slow current of 0.6m/sec and less but it overcome 1m at speedy current of 0.8m/sec and more. Opening width of the newly designed net was 1.4 times as large as that of the conventional net, ant the front projection area of the newly designed net mouth was estimated as 1.3~1.6 times as large as that of the conventional net. 2. The experiment on the stern operating system was tightly limited by the structure of the ship employed in the experiment, which was a stern trawler of 2275 GT. The ship confronted by the wind with main anchor, while the net was put over the stern slipway and the hauling line of shearing device was operated through the top rollers of gallows. The experiment was very suggestive in the view point to mechanize the operating system, and so to decrease the man power except the following question. The of bow-stern line of ship, and that of net is much different.

  • PDF

Polarus Intramedullary Nail for Nonunion of Humerus neck (Polarus 골수정을 이용한 상완골 경부 불유합의 수술적 치료)

  • Kang, Ho-Jung;Kim, Sul-Gee;Yoon, Hong-Kee;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.112-123
    • /
    • 2007
  • Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.

Correction of positional change of frontal cephalometric landmarks caused by vertical head rotation (두부의 수직회전 시 정모두부방사선사진상의 계측점 변화와 이의 보정)

  • Kim, Mi-Young;Lee, Kyung-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.98-111
    • /
    • 2011
  • Objective: Superimposition of frontal cephalograms cannot be performed when the cephalograms are taken with different vertical head rotations. The purpose of the present study was to evaluate the validity of correcting the positional change of frontal cephalometric landmarks caused by vertical head rotation. Methods: In 30 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle. Geometric principles of radiography were used to calculate the possible vertical and horizontal landmark changes if the head should be rotated down $5^{\circ}$ about an ear rod axis. The calculated changes were then compared with cephalometric changes measured on frontal cephalogram actually taken with the head rotated down $5^{\circ}$. Results: When the frontal cephalograms were taken with the head rotated down $5^{\circ}$ about an ear rod axis, significant changes in the vertical position of the landmarks occurred, particularly in the landmarks located farther anteriorly from the ear rod axis. The comparison of calculated changes and real cephalometric changes showed that the differences were less than 0.4 mm in the vertical direction and less than 0.2 mm in the horizontal direction. The differences between calculated and real changes were smaller in the landmarks less affected by vertical head rotation. Conclusions: Even when frontal cephalograms are taken at different vertical head rotations, the concomitant changes in the position of the landmarks can be corrected through calculation using the geometric principle of radiography as long as frontal and lateral cephalograms are taken perpendicular to each other.

Therapeutic Compliance for Calcium Supplements and Its Related Factors in Rural Osteoporotic Women (일부 농촌지역 여성 골다공증 환자의 칼슘보조제 치료순응도와 결정요인)

  • Chun, Byung-Yeol;Kam, Sin;Lee, Young-Ja;Lee, Sang-Won;Lee, Kyung-Eun;Lee, Young-Seok;Kim, Bong-Kee
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.2
    • /
    • pp.111-132
    • /
    • 2001
  • This study was conducted to examine the therapeutic compliance and its related factors in rural women with osteoporosis. A questionnaire survey was performed from April to May in 2000 for 140 osteoporotic patients who were diagnosed from April to June in 1999 through community health program. The study employed the health belief model for predicting and explaining sick role behavior. The analysis techniques employed included contingency table analysis and path analysis using LISREL. The major results of this study were as follows: Of the subjects, 12.1% were continuously complaint, 53.6% were intermittently compliant, and 34.3% were non- compliant to calcium supplement therapy. As the result of path analysis, the therapeutic compliance was significantly higher(${\mid}T{\mid}$ >2.0) as patients had higher perceived severity of disease, lower perceived barriers of treatment, and when patients thought their disease status as severe. As the patients had higher educational level, more experience of mass media contact or health education about osteoporosis, and when family had more concern for patient treatment, they had higher perceived susceptibility of complication(bone fracture)${\mid}T{\mid}$ >2.0). The patients had higher perceived severity(${\mid}T{\mid}$ >2.0) as they had more educational level, more advice for treatment from their doctors, and when family had more concern for their treatment. As the patients had more advice for treatment from their doctors and when family had more concern for their treatment, they had higher perceived benefit of treatment and lower perceived barriers to treatment(${\mid}T{\mid}$ >2.0). In order to improve the therapeutic compliance in rural osteoporotic women, it would be necessary that the patient should recognize their disease severity properly. And the perceived barriers should be removed through supportive environments for osteoporosis treatment such as doctor 's more advice and family 's more concern for treatment. In addition, effective and continuous management system for osteoporotic patients should be established.

  • PDF

Evaluation of Long-term Data Obtained from Seawater Intrusion Monitoring Network using Variation Type Analysis (변동유형 분석법을 이용한 해수침투 관측망 자료 평가)

  • Song, Sung-Ho;Lee, Jin-Yong;Yi, Myeong-Jae
    • Journal of the Korean earth science society
    • /
    • v.28 no.4
    • /
    • pp.478-490
    • /
    • 2007
  • With groundwater data of seawater intrusion monitoring network in coastal areas of Korea's main land, we analyzed types of seawater intrusion through the coastal aquifer. The data including groundwater level, temperature and electrical conductivity obtained from 45 monitoring wells at 25 watershed regions were evaluated. Based on statistical analysis, correlation analysis and variation type analysis, groundwater levels were mainly affected by rainfall and artificial pumping. About 78% of the monitoring wells showed average temperature higher than $15^{\circ}C$ and about 58% of them showed minimum variations less than $0.2^{\circ}C$. Electrical conductivities showed a large magnitude of variation and irregular characteristics compared with groundwater levels and temperatures. Average electrical conductivities lower than $2,000\;{\mu}S/cm$ were observed at 28 monitoring wells while those of higher than $10,000\;{\mu}S/cm$ were done at 9 monitoring wells. From the cross-correlation analysis, groundwater levels were mostly affected by precipitation while temperature and electrical conductivity showed very low correlation. Meanwhile tidal variations strongly affected the groundwater levels comparing to precipitation. We classified the long-term monitoring data according to variation types such as constant process, linear trend, cyclic variation, impulse, step function and ramp. Impulse type was dominant for variations of groundwater level, which was largely affected by rainfall or artificial pumping, the constant process was dominant for temperature. Compared with groundwater level and temperature, electrical conductivities showed various types like linear trend, step function and ramp. According to the discrepancy of variation characteristics for monitoring data at each well in the same region, periodical analysis of monitoring data is essentially required.

Relation of Correlation about Rice quality related Characters in Condition storage of Unhulled rice (정조 저장조건에서 식미관련특성에 대한 상관성 정도)

  • Hwang, Pil-Seong;Lee, Jeom-Sig;Kim, Kee-Jong;Son, Jong-Rok;Chung, Won-Bok;Oh, Ju-Seong
    • Journal of Life Science
    • /
    • v.17 no.4 s.84
    • /
    • pp.510-514
    • /
    • 2007
  • This study was carried on cool and RT(room temperature) storage of unhulled rice. In RT storage of an analysis of coefficient relation, high significant positive coefficients were observed in toyo index and breakdown, setback and protein content. high significant negative coefficients were showed setback and breakdown, breakdown and protein content. In cool storage of an analysis of coefficient relation, high significant positive coefficients were observed in toyo index and amylose content and gelatinization start temperature and protein content and high significant negative coefficients were showed toyo index and whiteness, toyo index and gelatinization start temperature, gelatinization start temperature and amylose content. In RT storage of a path coefficient analysis, a highest positive direct influence was observed in amylose content and a highest negative direct influence was protein content. Positive indirect influence was high revealed breakdown and protein content and negative indirect influence was gelatinization start temperature and Mg/K ratio. In cool storage of a path coefficient analysis, a highest positive direct influence was whiteness and a highest positive indirect influence was gelatinization start temperature. Positive indirect influence was high revealed gelatinization start temperature and amylose content, negative indirect influence was whiteness and gelatinization start temperature. In RT storage of Multiple regression equation of Toyo index based on physicochemical properties of unhulled rice, a highest coefficient of determination was revealed among five facters of whiteness, protein content, Mg/K ratio, amylose content and gelatinization start temperature. In cool storage of Multiple regression equation of toyo index based on physicochemical properties of unhulled rice, highest coefficient of determination was revealed among five facters of moisture content, amylose content, gelatinization start temperature, breakdown and setback.

A Ultrastructural Study on the Cerebral Ganglion of the African Giant Snail, Achatina fulica (아프리카 왕달팽이 (Achatina fulica) 뇌신경절 (Cerebral ganglion)의 미세구조)

  • Chang, Nam-Sub
    • Applied Microscopy
    • /
    • v.29 no.3
    • /
    • pp.303-313
    • /
    • 1999
  • In this paper, five kinds of neurosecretory cells-light green (LG) cell, dark green (DG) cell, caudo-dorsal (CD) cell, blue green (BG) cell, and yellow (Y) cell- and neuropils in the cerebral ganglion of the African giant snail, Achatina fulica, were observed with an electron microscope. The following results were obtained. The LG cells are circular or ovoid in shape, and about $60{\mu}m$ in size. The nucleus and cytoplasm of the LG cell look light due to their electron-low density. Large granular chromatins are evenly developed in the karyolymph, where round nucleoli are also found. In the cytoplasm, electron -high dense round granules of $0.4{\mu}m$ in average size are crowded. The DG cells are ovoid in shape, and $50\sim20{\mu}m$ in size. These relatively electron-high dense cells were rarely found. In their cytoplasm, cell organelles such as rough endoplasmic reticulum and mitochondria are found together with electron -high dense round granules of $0.2{\mu}m$ in average size. The CD cells are ellipsoidal cells densely distributed in caudo-dorsal parts of the cerebral ganglion. They have large nuclei compared with the cytoplasm. The developed granular heterochromatins are observed in the karyolymph, and lots of small round granules of $0.12{\mu}m$ in average size in the cytoplasm. The 3G cells, rarely found around endoneurium of the cerebral ganglion, take the shapes of long ellipses. They look dark due to their electron -high density. In the cytoplasm, small round granules of $0.1{\mu}m$ in average size are found. The Y cells are the smallest among the neurosecretory cells($9\times6.6{\mu}m$ in size). They are found mostly between the medio-dorsal parts and the caudo-dorsal parts of the cerebral ganglion. In the cytoplasm, tiny round granules of $0.08{\mu}m$ in average size form a group. The neuropils are found in the middle of the cerebral ganglion. In the axon ending, round granules with electron -high density ($0.07\sim0.03{\mu}m$ in diameter) and lucent vesicles ($0.03{\mu}m$ in diameter) are found in large quantities. They are excreted in the state of exocytosome formed by the invagination of the limiting membrane of the axon ending.

  • PDF

Analysis on the Demands for HACCP System at Meat Retailors - Based on HACCP-certified and Non-certified in Seoul and Gyeonggi Province, Korea - (식육판매업소 종사자의 축산물 HACCP 제도 요구도 분석 - 서울 및 경기지역의 HACCP 지정업소와 미지정업소를 중심으로 -)

  • Lee, Joo-Yeon;Suk, Hee-Jin;Paik, Jin-Kyoung;Hwang, Hye-Sun;Park, Dae-Seob;Paik, Hyun-Dong;Hong, Wan-Soo
    • Food Science of Animal Resources
    • /
    • v.32 no.3
    • /
    • pp.330-338
    • /
    • 2012
  • HACCP is a preventative food safety management system whose application is highly encouraged worldwide. In this study, the workers' demands for the application of HACCP system at the meat retail shops were surveyed. According to a factor analysis on the demands of the application of HACCP system, the results could be classified into three factors: HACCP support, HACCP promotion and education, and generic livestock product safety management. Items on demands showed higher results for HACCP support (3.91 point) than for HACCP promotion and education (3.83 point) or generic livestock product safety management (3.72 point). The application of HACCP system was more demanded by HACCPcertified retailors with 4.11 point than the non-HACCP-certified ones (3.57 point). From the analysis of items on demands, 'governmental promotion of the general public livestock HACCP; (p<0.001) was the highest demand item by the HACCPcertified retailors and 'HACCP certification support for the government's investment' by the non-HACCP-certified ones (p<0.05). The strengthening of governmental support for the application of HACCP at meat retail shops as well as active HACCP promotion and education aiming at general public was demanded. With this, the establishment of HACCP system and the improvement of safety management level at the area of meat retail shops could be achieved, contributing to the increase of consumers' satisfaction.

Crystal Growth of $Cr:Al_2O_3$ and $Ti:Al_2O_3$ by Czochralski Technique (용액인상법에 의한 $Cr:Al_2O_3$$Ti:Al_2O_3$ 단결정 육성)

  • Yu, Yeong-Mun;Lee, Yeong-Guk;Park, Ro-Hak
    • Korean Journal of Crystallography
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 1995
  • Cr:A12O3 and Ti:A12O3 single crystals were grown by Czochralski method, and the effects of crystal growth parameters such as pulling rate, rotation rate, dopant and growth atmosphere on crystal quality were investigated. And spectroscopic properties including lasing efficiency were also measured. Single crystals, sized of 20mm in diameter and 100-135mm in length, were successfully grown from the seed of <001> direction. With the doping level of 0.5w/o Cr2O3, pulling rate 2.0mm/hr, rotation rate of 30rpm and inert atmosphere by nitrogen gas, high quality crystals of Cr:A12O3 were grown. While in case of Ti:A12O3 crystals, high quality crystals were grown under the conditions of the doping level of 0.25w/o TiO2, pulling rate of 1.5mm/hr, rotation rate of 30rpm and reducing atmosphere by hydrogen - nitrogen mixed gas. It was confirmed that Cr3+ ion which maintains its ionoc valence during growth easily de-bubbled than Ti4+ ion which changes its valence, Fe3+ ion also has do-bubbling effect to Ti:A12O3 crystal and the reducing atmosphere by 90% N2 - 10% H2 mixed gas gave effective result on the changing of Ti4+ to Ti3+ and de-bubbling. As a result of spectroscopic measurements of Cr:A12O3 crystal, 4A2 →4F2 and 4F1 absorption transitions and E →4A2(R1) and 2A →4A2(R2) fluorenscence transitions were confirmed. And it was measured that wavelengths of laser R1 and R2 transitions were 696±5nm and 692±5nm respectively, line width of these transitions were 12A, and life-time of fluorenscence was 152μsec. In case of Ti:A12O3 crystals, it was confirmed that absortion transition of 4T2→4E and fluorescence transition of 4E→4T2 with wide range of 650-1050nm was occured. And 147μsec of life-time of fluorescence, 125.4 of figure of merit and 9% of laser efficience were also measured.

  • PDF

The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF