• Title/Summary/Keyword: 정량적 정확성

Search Result 312, Processing Time 0.029 seconds

Determination of Vitamin B12 and Biotin in Foods for Special Dietary Uses with Immunoaffinity Column (면역친화성 컬럼을 이용한 특수용도식품 중 비타민B12와 비오틴 분석 연구)

  • Oh, Bo-Young;Ye, Min-Ji;Hu, Soo-Jung;Lee, Hye-Young;Bang, Soo-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.252-260
    • /
    • 2020
  • This study was conducted to improve the standard method for vitamin B12 and biotin contained in foods for special dietary uses to ensure the specificity of the complex matrix properties of foods. For the food code, the test method was improved to determine vitamin B12 and biotin by high-performance liquid chromatography (HPLC)-UV using column-switching after concentration using immunoaffinity column. The immunoaffinity columns contain a gel suspension of monoclonal antibody specific to the vitamin of interest so that it can be used to concentrate the vitamin B12 and biotin and remove interferences from the food extracts. Moreover, validation of advanced new methods was carried out to support the suitability of the proposed analytical procedure (specificity, linearity, detection limits (LOD), quantitative limits (LOQ), accuracy, and precision). The improved analytical method is being used to monitor relevant food items on sale. The results of this study showed that the new analytical method is suitable and appropriate for managing food intended for special dietary uses.

Determination of Natural Gas Components by Gas Chromatographic Multicolumn System (기체 크로마토그래피 복합컬럼 시스템에 의한 천연가스 성분의 정량)

  • Choi, Yong-Wook;Choe, Kun-Hyung
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.339-347
    • /
    • 1994
  • A multicolumn system consisted of two valve(10-port and 6-port valve)-three column (28% DC 200, SP 1700 and Chromosorb 102 column) was developed. Nine natural gas components composed of $N_2$, $CH_4$, $CO_2$, $C_2H_6$, $C_3H_8$, $i-C_4H_{10}$, $n-C_4H_{10}$, $i-C_5H_{12}$$n-C_5H_{12}$ completed all the baseline separation within 18 minutes. The accuracy and the precision of this system was tested. The retention times and the peak areas were determined with a repeatability between 0.02 and 0.16%, and less than 1%, respectively. Calibration curves for natural-gas components were plotted by the partial pressure injection method of pure gases, and good linear relationships for each component were presented. By using these calibration curves the accuracy of the multicolumn system compaired with that of the single column system for a certified standard gas of natural gas. As a result, relative error in the single and the multicolumn system was less than 0.5% and 0.04%, respectively. The result of application of this system in the analysis of importing LNG composition showed that the heating values calculated by the multicolum system were estimated lower compared with those calculated by the single column system and consequently, the importing price of LNG was able to be cut down.

  • PDF

Study on evaluating the significance of 3D nuclear texture features for diagnosis of cervical cancer (자궁경부암 진단을 위한 3차원 세포핵 질감 특성값 유의성 평가에 관한 연구)

  • Choi, Hyun-Ju;Kim, Tae-Yun;Malm, Patrik;Bengtsson, Ewert;Choi, Heung-Kook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.10
    • /
    • pp.83-92
    • /
    • 2011
  • The aim of this study is to evaluate whether 3D nuclear chromatin texture features are significant in recognizing the progression of cervical cancer. In particular, we assessed that our method could detect subtle differences in the chromatin pattern of seemingly normal cells on specimens with malignancy. We extracted nuclear texture features based on 3D GLCM(Gray Level Co occurrence Matrix) and 3D Wavelet transform from 100 cell volume data for each group (Normal, LSIL and HSIL). To evaluate the feasibility of 3D chromatin texture analysis, we compared the correct classification rate for each of the classifiers using them. In addition to this, we compared the correct classification rates for the classifiers using the proposed 3D nuclear texture features and the 2D nuclear texture features which were extracted in the same way. The results showed that the classifier using the 3D nuclear texture features provided better results. This means our method could improve the accuracy and reproducibility of quantification of cervical cell.

Studies on Standardization of Licorice Based on Its Active Components with On-line HPLC Bioassay System (실시간 활성시스템을 접목한 감초의 유효성분에 대한 표준화 연구)

  • Hong, Jae Seung;Kang, Bum Gu;Jang, Young Soo;Kim, Seon Ha;Wang, Zhiqiang;Park, Yoon Ha;Park, Jong Hyuk;Lim, Soon Sung
    • Korean Journal of Plant Resources
    • /
    • v.27 no.5
    • /
    • pp.401-414
    • /
    • 2014
  • In an attempt to evaluate licorice quality based on its biological activity, we grafted an on-line high-performance liquid chromatography (HPLC) bioassay method into the previously established HPLC analysis method. The common antioxidant peaks in licorices of various origin were observed through an on-line HPLC/DPPH system leading to a decrease in absorbance at 517 nm for 2,2-diphenyl-1-picrylhydrazyl (DPPH). Among them, the licorice from Youngju possessed the highest activity. Therefore, three active standard compounds from the dehydroglyasperin C, dehydroglyasperin D, and isoangustone A, were isolated and elucidated by medium pressure liquid chromatography (MPLC) and instrumental analysis such as nuclear magnetic resonance (NMR), respectively. On-line HPLC/ABTS analysis method with the simultaneous determination of three standard compounds and their radical scavenging activity was established for the quality evaluation of licorices. 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid radicals (ABTS) which is stable and effective was used in replace of DPPH. The radical scavenging activity of three standards is compared with that of Trolox, known as antioxidant, showing a negative peak with a decrease in absorbance at 734 nm for ABTS. This on-line HPLC/ABTS analysis method was validated for specificity, linearity, precision and accuracy in compliance with international conference on harmonization (ICH) guideline.

Isolation and HPLC-DAD validation of xanthoangelol in Lespedeza bicolor extract (싸리나무 추출물의 Xanthoangelol 분리 및 HPLC-DAD 밸리데이션)

  • Woo, Hyun Sim;Kim, Yeong-Su;Oh, Yu Jin;Cho, Hae Jin;Song, Se-Kyu;Kim, Dae Wook
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.26-30
    • /
    • 2020
  • This study was undertaken to determine the characteristics of xanthoangelol, the major chalcone constituent derived from the extracts of different parts of Lespedeza bicolor. Xanthoangelol was isolated from the root extract using column chromatography and used as a standard for quantitative analysis. The structure of the isolated compound was established based on spectroscopic evidence. The HPLC-DAD method was validated for specificity, linearity, precision, accuracy, limit of detection, and limit of quantitation. The calibration curve of xanthoangelol had significant linearity (R2>0.9999). Limit of detection and limit of quantitation 0.018 and 0.059 ㎍/mL, respectively. The relative standard deviation values of precision test, and intra- and inter-day tests were less than 0.22 and 0.40%, respectively. In the recovery test, the accuracy ranged from 98.98-102.78% with RSD values less than 0.13%. The method validation parameters indicate the applicability of the HPLC method for quality control of food or drug formulations containing L. bicolor.

The Effect of Uncertainty in Roughness and Discharge on Flood Inundation Mapping (조도계수와 유량의 불확실성이 홍수범람도 구축에 미치는 영향)

  • Jung, Younghun;Yeo, Kyu Dong;Kim, Soo Young;Lee, Seung Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.937-945
    • /
    • 2013
  • The accuracy of flood inundation maps is determined by the uncertainty propagated from all variables involved in the overall process including input data, model parameters and modeling approaches. This study investigated the uncertainty arising from key variables (flow condition and Manning's n) among model variables in flood inundation mapping for the Missouri River near Boonville, Missouri, USA. Methodology of this study involves the generalized likelihood uncertainty estimation (GLUE) to quantify the uncertainty bounds of flood inundation area. Uncertainty bounds in the GLUE procedure are evaluated by selecting two likelihood functions, which is two statistic (inverse of sum of squared error (1/SAE) and inverse of sum of absolute error (1/SSE)) based on an observed water surface elevation and simulated water surface elevations. The results from GLUE show that likelihood measure based on 1/SSE is more sensitive on observation than likelihood measure based on 1/SAE, and that the uncertainty propagated from two variables produces an uncertainty bound of about 2% in the inundation area compared to observed inundation. Based on the results obtained form this study, it is expected that this study will be useful to identify the characteristic of flood.

Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6 (GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사)

  • An, Jung-Su;Lee, Chang-Lae;Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.571-575
    • /
    • 2016
  • Monte Carlo simulations are widely used as the most accurate technique for dose calculation in radiation therapy. In this paper, the GATE6(Geant4 Application for Tomographic Emission ver.6) code was employed to calculate the dosimetric performance of the photon beams from a linear accelerator(LINAC). The treatment head of a Varian 21EX Clinac was modeled including the major geometric structures within the beam path such as a target, a primary collimator, a flattening filter, a ion chamber, and jaws. The 6 MV photon spectra were characterized in a standard $10{\times}10cm^2$ field at 100 cm source-to-surface distance(SSD) and subsequent dose estimations were made in a water phantom. The measurements of percentage depth dose and dose profiles were performed with 3D water phantom and the simulated data was compared to measured reference data. The simulated results agreed very well with the measured data. It has been found that the GATE6 code is an effective tool for dose optimization in radiotherapy applications.

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

Quality Control System for Analytical Chemistry Laboratory of Pesticide Products (농약 이화학시험 분석기관 정도관리체계)

  • Chang, Hee-Ra;Lee, Joon-Yeob;Lee, Young-Ju;Kang, Hye-Rim;Kim, Chan-Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.529-544
    • /
    • 2011
  • Many international organizations, such as the International Organization for Standardization (ISO) and Collaborative International Pesticide Analytical Council (CIPAC), have published a guide to quality control requirements, proficiency testing and method validation for pesticide formulation. In general, proficiency testing is to determine the performance of individual laboratories from the comparison of test results and to monitor a laboratory's performance abilities. One of quality assurance (QA) scheme would be include the validation of analytical method that implies a performance characteristics, specificity, selectivity, linearity and so on. According to many international organizations, the quantification methods of active substance in formulated pesticide products are required to be reproducible, accurate and precise. This study was conducted to compare the international guidelines for the quality control, proficiency testing and method validation of analytical laboratories and to propose a general guidance for the establishment of quality control system in the analytical chemistry laboratories of pesticide formulation in domestic.

Monitoring of illegal compounds and prohibited natural ingredients in foods (식품 중 발기부전치료제 및 사용금지 성분 모니터링)

  • Yun, Jisuk;Choi, Jangduck;Kwon, Kisung;Jo, Cheon-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.405-412
    • /
    • 2016
  • Illegally adulterated compounds, such as impotency drugs and their synthetic analogues, which have been purported to enhance sexual potency or mood, have been constantly detected in foods including dietary supplements. The adulterated foods with these illegal compounds may threaten public health because their safety and efficacy have not been verified. This study was aimed at investigating illegal compounds in foods and counterfeit products. 54 illegal compounds were assayed using a simultaneous analytical method involving liquid chromatography equipped with photo diode array (LC-PDA) and LC coupled with tandem mass spectrometry (LC-MS/MS). The method was validated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision and accuracy. In 48 of 161 samples, we identified 7 different illegal compounds, including sildenafil, tadalafil, chlropretadalafil, demethylsildenafil, dimethyl-thiosildenafil, icariin and yohimbine. When purchasing products marketed for erectile dysfunction or aphrodisiacs, ulmost care should be taken owing to the possible presence of these illegal compounds.