• Title/Summary/Keyword: 정격전류

Search Result 234, Processing Time 0.023 seconds

Efficiency Improvement of Switched Reluctance Generator According to Current Shape in the High Speed Region (고속영역에서 전류형상에 따른 스위치드 릴럭턴스 발전기의 효율 개선)

  • Ahn, Jin-Woo;An, Young-Joo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.68-74
    • /
    • 2015
  • This paper describes about the efficiency improvement of switched reluctance generator (SRG) over the rated speed region. Since the current shape has a great influence on the loss of the machine, so the system efficiency can be improved by optimizing the current shape. In case the wide speed range application such as wind power and medium size hydraulic power generation, a method of switching angle control is suggested to obtain the wanted current shapes. In order to verify the method, the experimental platform is set up. The feasibility of the theory is verified by simulation and experimental results.

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts (볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석)

  • Yeon, Yeong-Mo;Kim, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.67-75
    • /
    • 2020
  • In this study, the risk of heat generation due to normal and overload currents that vary with the abnormal loosening angle of wire-connecting bolts were identified. The risks were analyzed based on the thermal characteristics to minimize the carbonization accidents of terminal blocks inside distribution panels typically used in industrial sites. We applied a method for measuring the heating temperature and temperature variations in the terminal blocks in real-time by installing a resistance temperature detector sensor board in the terminal block. The experimental results showed that the terminal block model with a low-rated current exhibited a higher heating temperature, thus, confirming the need to select the terminal block capacity based on load currents. Additionally, the higher the rated current of the terminal block with a high-rated current and the higher the degree of loosening, the faster the carbonization point. Such heating temperature monitoring enabled real-time thermal temperature measurement and a step-by-step risk level setting through thermal analysis. The results of the measurement and analysis of carbonization risks can provide a theoretical basis for further research regarding the risk of fire due to carbonization. Furthermore, the deterioration measurement method using the temperature sensor board developed in this study is widely applicable to prevent fires caused by poor electrical contact as well as risk-level management.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

전기화재 원인과 발생⑨

  • 김미승
    • Electric Engineers Magazine
    • /
    • v.251 no.7
    • /
    • pp.24-27
    • /
    • 2003
  • 전열기 및 전기의 발열작용을 이용한 전기기기에는 정격용량 및 허용용량에 맞는 저항기 및 온도제어장치를 이용하여 전기사용기기에 허용전류이상 또는 허용용량 이상의 전류가 흐르지 못하게 하는데 이들 저항기 및 온도제어장치 고장 및 구조적 결함으로 과부하 형태가 나타날 수 있다.

  • PDF

The Transition Control Technique between Sinusoidal-Wave and Square-Wave Driving Method in Inverter for PMSM (영구자석형 동기전동기용 인버터에서 정현파-구형파 운전 방식 사이의 전환 방법)

  • Lee, Seung-Yong;Yoon, Duck-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.113-114
    • /
    • 2016
  • 영구자석형 동기전동기를 구동하는 인버터에서는 기본적으로 정현파 운전 방식을 사용하지만 최근에는 구형파 운전 방식도 종종 사용되고 있다. 정현파 운전 방식은 구형파 운전 방식에 비해 토크 리플이 작고 기동 성능이 우수하며, 약자속 제어를 이용하여 정격 속도 이상의 고속 운전이 가능하다. 이에 비해 구형파 운전 방식은 제어 알고리즘이 간단하고 스위칭 손실이 적은 장점이 있지만, 토크 리플이 크고 정격 속도 이하의 영역에서만 운전이 가능하다는 단점이 있다. 최근에 인버터의 운전 중에 각각의 장점이 있는 이들 2가지 운전 방식을 서로 전환하는 방법으로 가전제품의 압축기와 같은 연속 부하에 적용하기 위한 연구가 진행되었다. 저속 구간에서는 스위칭 손실을 줄이기 위하여 구형파 운전 방식을 주로 사용하고, 고속 구간에서는 안정적인 제어 성능을 위하여 정현파 운전 방식을 사용한다. 또한, 이 2가지 운전 방식의 전환 구간에서의 발생되는 과도 상태를 짧게 줄이기 위하여 속도 및 전류 제어기의 제어 변수에 대한 초기화 방법이 제시되었다. 본 논문에서는 구형파 운전 구간의 속도 제어기에 비례 적분 전류 제어기를 추가하여 전류 리플을 감소시키고, 전환 구간에서의 속도 및 전류 제어기의 제어 변수에 대한 초기화 방법을 제시하였다.

  • PDF

Changes of Electrical Characteristics of Low-voltage ZnO Varistors by a lightning Impulse Current (뇌충격전류에 의한 저압용 산화아연형 바리스터의 전기적 특성변화)

  • 이종혁;한주섭;길경석;권장우;송동영;최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.793-801
    • /
    • 2000
  • This paper presents the effect of lightning impulse current on ZnO varistors(390[V], 6.5[kA]) used in low-voltage AC mains as a protective device against transient overvoltages. The electrical characteristics of ZnO varistors are deteriorated by overtime impulse current, and a deteriorated ZnO varistor is brought to a thermal runaway and finally destroyed even in normal operating voltage. Therefore, it is important to estimate the changes of the electrical characteristics of ZnO varistors. A lightning impulse current standardized in IEC 61000-4-5 is applied to the varistors to accelerate deterioration, and the energy applied to the varistor at each time is about 12 [J]. In the experiment, various parameters such as leakage current, reference voltage are measured with the number of applied impulse current. Also, micro-structure changes of the varistors after applying the lightning impulse current of 200 times are compared. The electrical characteristics of the varistors are degraded by overtime impulse current, showing increase in leakage current and decrease in reference voltage.

  • PDF

Operating Characteristics of Molded Case Circuit Breakers by Harmonic Currents (고조파 전류에 의한 배선용 차단기 동작 특성)

  • Jeon, Jeong-Chay;Yoo, Jae-Geun;Lee, Sang-Ick
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.68-74
    • /
    • 2006
  • Malfunction and nuisance tripping of molded case circuit breaker(MCCB) caused by harmonic currents have been reported. But no data is available on the behavior of MCCB under harmonic currents. This paper tested the effects of harmonic currents on four common types of MCCB(thermal, thermal magnetic, magnetic and electronic types). Results of experiment detected no nuisance tripping with any of the breakers tested under test currents, included harmonic current, below rated currents. Additionally it was found that varying harmonic loading conditions did not affect manufacturer specified trip times for thermal only and thermal magnetic circuit breakers. However, under overloaded conditions, trip times of the magnetic only circuit breakers were gradually slowed according to increasing of harmonic currents, and it could cause hazardous overheating of cables. So, the use of magnetic only circuit breakers in the place harmonic currents we serious must be avoided.

Optimized Design of Utility Interactive Inverter for Fault Ride Through and Voltage Compensation (Fault Ride Through와 독립부하전압 보상 기능을 갖는 계통연계 인버터의 최적설계)

  • Kim, Hyungjin;Choi, Sewan;Yoon, Sunjae
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.522-523
    • /
    • 2011
  • 독립부하가 존재하는 분산발전시스템에서 FRT 기능을 수행하는 경우, 계통의 이상전압이 인버터의 독립부하에 그대로 걸리게 되는 문제가 있다. 이에 따라 FRT 기능을 준수함과 동시에 독립부하에도 일정한 품질의 전압을 공급할 수 있는 전압보상기법이 제안된 바 있다. 이때 무효전류 주입에 의해 IGBT의 전류정격이 증가되는데 본 논문에서는 인버터의 정격 상승량 분석을 통하여 이에 맞는 스위치를 선정하고 인버터의 모델을 고려한 전압보상기법 제어기 설계 기법을 제안한다.

  • PDF

Development of Simulator Algorithm for Switchgear of New Energy Sources (신에너지전원용 수배전반 시뮬레이터(S/W) 제작에 관한 연구)

  • Song, Bang-Woon;Lee, Heon-Tae;Rho, Dea-Seok;Jang, Se-Woo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.549-553
    • /
    • 2012
  • 신에너지원의 도입증가에 따라 수 배전설비에서도 각종 계전기의 보호협조 및 기기의 구성이 필요하고, 또한 사고에 따른 문제점 및 배전계통에서 수용가에 이르기까지의 설비들의 용량의 변화가 시급한 상황이다. 이에 따라 본 논문에서 제시한 신에너지용 수배전반 시뮬레이터는 사용 용량에 맞는 수배전반을 구성, 계통에 필요한 보호 지점과 보호 방식을 구성하는 등 수배전 계통의 구성를 편리하게 시뮬레이션 할 수 있도록 하였다. 그리고 기기의 정격전류, 사고전류를 계산하여 동작 특성에 따른 보호방식을 선택하여 수배전 기기를 선정할 수 있도록 제작하였다.

  • PDF