• Title/Summary/Keyword: 접촉조

Search Result 299, Processing Time 0.03 seconds

Application of CFD Program for Analyzing the Hydrodynamic Characteristics of Baffled PAC Contactor (격벽식 분말활성탄 접촉조의 흐름해석을 위한 전산유체역학 프로그램의 적용)

  • Ahn, Chang-Jin;Ahn, Sang-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.221-229
    • /
    • 2002
  • For the efficient design of baffled Powdered activated carbon(PAC) contractor, which has been widely used in water treatment plant(WTP) against the algae-related odor problems, a CFD(computational fluid dynamics) program was applied. In order to verify the performance of FLOW-3D program, the previously reported results of tracer tests from a pilot-scale PAC contractor(working volume of 288 liters) were compared to those from FLOW 3D. The results of FLOW-3D simulation were very similar to those from tracer tests conducted with the Pilot-scale PAC contactor. On the other hand, the hydrodynamic characteristics of baffled contractor in the P-WTP were simulated by using FLOW-3D. Simulation results on the distribution of PAC particles showed that there are some stagnant parts in the back side of baffles in which PAC Particles are not present. These stagnant parts might decrease the adsorption capacity of PAC particles. When the baffles were changed to maze-type intra-basin baffling, PAC particles were evenly distributed and the amount of stagnant parts reduced. In conclusion, it is anticipated that FLOW-3D simulation could be a viab1e tool for analyzing the hydrodynamic characteristics of structures used in drinking water treatment plant.

Contactor Coupled Sequencing Batch Reactor for Nitrogen Removal (접촉조 결합형 연속회분식반응조를 이용한 질소제거)

  • Nam, Se-Yong;Lee, Sang-Min;Kim, Dong-Wook;Seo, Yong-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1141-1145
    • /
    • 2005
  • A contactor coupled sequencing batch reactor composed of pre-anoxic contact zone and intermittently aerated zone was proposed and operated for nitrogen removal. Emphasis was placed on the fact that the contactor can be operated in a rapid reaction mode that results In biological uptake but incomplete metabolism of organic matter. Consequently, 61.2% of the sewage SCOD was adsorbed to activated sludge by 30-minute contact reaction. The specific uptake of organic matter was 22.3 mg SCOD/g MLVSS that enhanced the denitrification efficiency in the following denitrification stage. The removal efficiencies of the organic matter(SCOD) and the total nitrogen(T-N) were 86% and about 60% at the TCOD/TKN ratio as low as 6.0, respectively.

법령과고시 - 수도용 자재 및 제품, 위생안전기준 인증제도(KC) 전면 시행

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.273
    • /
    • pp.76-79
    • /
    • 2013
  • '수도법' 제14조 및 환경부령 '수도용 자재와 제품의 위생안전기준 인증등에 관한 규칙' 제2조에 따라 물과 접촉하는 수도용 자재와 제품을 제조, 수입, 공급, 판매코자 하는 자는 '위생안전기준 인증(KC)'을 취득 후 제조, 수입, 공급, 판매해야 하며 위반 시 '수도법' 제83조, 제87조에 근거한 벌칙을 적용받게 된다. 또한 일반수도 및 전용 상수도를 설치하려는 자도 물과 접촉하는 수도용 자재와 제품을 사용할 경우에는 '수도법' 제14조제3항에 의거하여 '위생안전기준 인증(KC)' 제품을 사용해야 하며 위반 시 '수도법' 제83조에 근거한 벌칙을 받는다.

  • PDF

Numerical Study of Effect of DAF-Tank Shape on Flow Pattern in Separation Zone of Dissolved Air Flotation (용존공기부상조(DAF-tank)의 형상변화가 분리조(Separation Zone)의 내부 유동 패턴에 미치는 영향에 대한 수치해석적 연구)

  • Ryu, Gwang-Nyeon;Park, Sang-Min;Lee, Ho-Il;Chung, Mong-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.855-860
    • /
    • 2011
  • We numerically simulated a dissolved air flotation (DAF) tank to predict the performance of the pilot facility. The flow was assumed to be two-dimensional and two-phase. The velocity distributions in the separation zones of differently shaped DAFs were compared to find the effect of the shape on the performance. The results showed that the typical flow pattern that appeared in a well-designed DAF-tank was generated in the separation zone of the base model. This flow pattern could be maintained while the baffle height was sufficiently tall regardless of the other geometric parameters. However, the baffle height and angle, the contact zone width, and the perforated plate affected the uniformity of the downward flow in the separation zone. Except for the baffle height, the base model used in this study showed a better uniformity of downward flow than did other models with different geometric parameters.

A Study on the Model and the Design Procedure of the Contact Stabilization Process (접촉안정법(接觸安定法)의 모델과 설계법(設計法)에 관한 연구(硏究))

  • Yang, Sang Hyon;Ahn, Song Yeob
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.2
    • /
    • pp.101-112
    • /
    • 1984
  • The mechanisms and the models of the contact stabilization process were briefly reviewed. The researchers proposed the more practical and rational models and the procedure for the design of the contact stabilization process. These models were derived from the material balances of the system based on the increase of Mixed Liquor Suspended Solids (MLSS) in. the contact tank and the decrease of MLSS in the stabilization tank. The proposed models were also discussed with the experimental data.

  • PDF

Study on the Profile of Nut Bearing Surface and the Torque Coefficient of a High Strength Bolt Set (고장력 볼트세트의 자리면형상과 토크계수에 관한 연구)

  • Lee, Baek Joon;Sohn, Seung Yo
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.143-150
    • /
    • 2000
  • Depending upon the combination of tolerances specified in the standards on bolt, nut and washer for high tension bolt sets, there arises center-to-center deviation between bolt and washer. This deviation nay cause loss of effective contact area between nut- and washer-faces, which leads to some dispersion of the torque coefficient K. By adapting circular arc surface instead of flat surface for the nut, it is shown through numerical analyses that the dispersion of the torque coefficient can be minimized. In this way, optimum radius of curvature of the nut bearing surface is proposed.

  • PDF

Effects of Surface Roughness on Contact Angle of Nanofluid Droplet (표면조도가 나노유체 액적의 접촉각에 미치는 영향)

  • Kim, Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.559-566
    • /
    • 2013
  • The effects of solid surface roughness on the contact angle of a nanofluid droplet were experimentally investigated. The experiments were conducted using the solid surface of a 10 mm cubic copper block and the nanofluid of water mixed with CuO nanoparticles. The experimental results showed that the contact angles of nanofluid droplets were lower than those of water droplets and that the contact angle of the nanofluid droplet increased with the solid surface roughness. Furthermore, it was found that the contact angles of water droplets on the solid surface quenched by both water and the nanofluid were lower than those of water droplets on the pure solid surface. However, significant differences were not observed between the contact angles on the solid surfaces quenched by water and the nanofluid.

The test-bed construction and water purification assessment of the eco-convergence type aerated string contacted oxidation system (생태융합형 접촉산화수로 Test-Bed 구축 및 정화효율 평가)

  • Choi, Sunhwa;Lee, Seung-Heon;Jang, Kyusang;Kim, Heungseop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.592-592
    • /
    • 2016
  • 국내에는 17,500여개의 농업용 저수지가 전국적으로 분포하고 있다. 국내 농업용 저수지는 대부분이 소규모이며, 연중 수량 변동이 심하고, 유역배율이 작아 태생적으로 수질오염에 취약한 구조로 되어 있다. 특히 농업용 저수지는 도시 근교나 농촌지역에 많이 위치하고 있어 유역 내 축산 농가나 미처리 생활하수에서 유래된 유기물 및 영양염류 유입에 의한 수질오염도가 높다. 저수지에 고농도로 유입되는 유기물, TN, TP를 처리하기 위하여 농어촌연구원과 수생태복원(주)에서는 공동으로 친환경 수처리시설인 생태융합형 접촉산화시스템을 개발하였다. 생태융합 접촉산화수로는 상부 식생과 수로 내의 섬유상 끈상 미생물 접촉재를 이용하여 오염수가 수로를 흐르면서 침전, 여과, 흡착, 산화, 흡수 등 물리학적, 화학적, 생물학적 원리를 이용하여 고농도의 유기물과 질소, 인을 제거하는 물리적, 생물학적 공정을 융복합 기술이다. 본 연구에서는 경기도 시흥시에 소재하고 있는 M 저수지에 현장 Test-bed를 구축하여 수질정화효율을 평가하였다. M 저수지는 유효저수지량이 약 23만톤에 해당하는 소규모 저수지로, 1941년도 준공된 아주 노후화된 저수지로 평균 수심이 2m 이하이고 연중 수질오염도가 높은 저수지이다. 매화저수지 수변에 설치된 생태융합형 접촉산화수로의 전체규모는 길이 8.6m, 폭 2m, 수심 2m에 해당하며, 끈상 미생물 메디아조 3개($2{\times}2{\times}6m^3$), 침전조 1개($2{\times}2{\times}2m^3$)로 구성되어 있다. 기타 부대 장치로는 끈상 메디아조에 산소공급을 위한 Air-mist(마이크로 버블 발생장치), 자동운전계기판, 유입펌프 등이 있다. 생태융합형 접촉산화수로의 처리 공정은 유입수${\rightarrow}$에어미스트${\rightarrow}$고속복합응집장치${\rightarrow}$융복합 산화조(3조)${\rightarrow}$침전조${\rightarrow}$방류로 구성되어 있다. 테스트 베드는 2015년 8월 말경에 구축 완료하였으며, 끈상 미생물 메디아조의 수질정화효율을 평가하기 위하여 9월부터 11월까지 총 7회 걸쳐 유입수와 유출수를 각각 조사하였다. 현장 측정항목인 수온, pH, EC, DO 등은 유입수 및 유출수간 큰 차이가 없었고, COD, SS, Chl-a, TP 등은 수처리시스템 초기 가동시에는 메디아에 미생물 부착율 저조로 유입수 및 유출수 수질농도에 큰 차이가 없었으나, 운영시간의 경과와 함께 메디아의 미생물 충진율이 높아짐에 따라 처리효율이 최대 SS 69.6%, Chl-a 89.3%, TP 89%까지 도달하는 것으로 나타났다. 생태융합 접촉산화수로는 부지 집약적인 컴팩트한 수처리 시설로서 현재 널리 이용되고 있는 인공습지를 대체할 수 있는 경제적인 시설로 판단된다.

  • PDF