• Title/Summary/Keyword: 접촉강도

Search Result 467, Processing Time 0.025 seconds

A Study on the Fundamental Mechanical Properties of Hydrophobic Cementeous Mortar using Silane Admixtures (실란계 혼화제를 활용한 소수성 시멘트 모르타르의 기초물성 연구)

  • Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.2
    • /
    • pp.79-86
    • /
    • 2018
  • In this study, emulsion type hydrophobic admixture was prepared by mixing polyvinyl alcohol surfactant, polymethyl hydro-siloxane and meta kaolin, and the compressive strength and mechanical properties such as permeability and contact angle test of the mortar were evaluated. The developed hydrophobic admixture showed no decrease in strength and the mortar specimen with magnesium oxide developed the early strength. In the case of permeability, total seepage was significantly decreased when the hydrophobic admixture was directly mixed with the mortar, but the effect of meta kaolin contained in hydrophobic admixture was not significant. The surface of specimens coated with hydrophobic admixture shows that the contact angle on the surface was highly increased compared with reference mortar specimen. Further researches to obtain the optimum mix proportion of the PVA fiber, nano-silica and meta kaolin for producing the super-hydrophobic surface are required.

Effect of Surface Free Energies on Mechanical Properties of Epoxy/Polyurethane Blend System (에폭시/폴리우레탄 블렌드 시스템의 표면 자유에너지 변화가 기계적 특성에 미치는 영향)

  • 박수진;진중성;이재락;박병기
    • Polymer(Korea)
    • /
    • v.24 no.2
    • /
    • pp.245-251
    • /
    • 2000
  • A blend system prepared from epoxy(EP) and polyurethane (PU) was investigated in terms of the contact angle and mechanical properties. The contents of EP/PU were varied within 100/0~100/60 phr in the presence of 20 phr DDM (4,4'-diamino diphenyl methane) as a curing agent for epoxy resin. Contact angle measurements were performed employing a Rame-Hart contact angle goniometer. Deionized water and diiodomethane were chosen as the testing liquids. In this work, Owens-Wendt and Wu's models using a geometric mean were studied to analyze the surface free energy of blend system. For the mechanical and toughening properties of the casting specimens, the critical stress Intensity factor ($K_{IC}$) and impact test were performed. Especially, the impact test was carried out at room and cryogenic temperatures. As a result, specific or polar component of the surface free energy of the blend system was largely influenced on the addition of the PU resulting in increasing the impact strength for the excellent low- temperature performance.

  • PDF

Interfacial Evaluation of Surface Treated Jute Fiber/Polypropylene Composites Before and After Hydration Using Micromechanical Test (미세역학적 시험법을 이용한 표면처리된 Jute 섬유 강화 폴리프로필렌 복합재료의 수화 전·후 계면물성 평가)

  • Kim, Pyung-Gee;Jang, Jung-Hoon;Park, Joung-Man;Hwang, Byung-Sun
    • Journal of Adhesion and Interface
    • /
    • v.8 no.3
    • /
    • pp.9-15
    • /
    • 2007
  • The interfacial evaluation of surface modified Jute fiber/polypropylene (PP) composites before and after hydration was investigated using micromechanical test and dynamic contact angle measurement. The IFSS of alkaline and silane-treated Jute fiber/PP composites increased, whereas after hydration, the IFSS of the untreated, alkaline- and silane-treated Jute fibers/PP composites decreased due to swelled fibrils by water infiltration. The interfacial adhesion of silane treated fiber/PP composites was higher than alkaline-treated or the untreated cases. The surface energies of Jute fiber treated under various conditions were obtained using dynamic contact angle measurement. Especially after hydration, the thermodynamic work of adhesion was calculated by considering water interlayer, which indicated the stability of IFSS between silane treated Jute fiber and PP matrix showing better than others.

  • PDF

Impact Behaviors of Ni-plated Carbon Fibers-reinforced Epoxy Matrix Composites (니켈도금된 탄소섬유 강화 에폭시 수지 복합재료의 충격 특성)

  • 박수진;김병주;이종문
    • Polymer(Korea)
    • /
    • v.27 no.1
    • /
    • pp.52-60
    • /
    • 2003
  • In this work, two types of Ni-plating, namely electrolytical and electroless Ni-platings on carbon fiber surfaces, were carried out to enhance the impact resistance of composites. And the comparison between electrolytical and electroless methods on their impact properties of composite system was studied. The surface properties of carbon fibers were characterized using XRD, SEM, and contact angle measurements. The impact behaviors were investigated using an Izod type impact tester. As experimental results, it was observed that electrolessly plated Ni layers had Ni-P alloys on carbon fiber surfaces as revealed by XRD, and electrolytically Ni-plated carbon fibers showed higher surface free energies than those of the electrolessly Ni-plated carbon fibers. In particular, the impact strengths of electrolessly Ni-plated carbon fibers-reinforced plastics were strongly increased. These results were probably due to the difference of wettabilities according to the different types of Ni-plating methods.

Design of Ground Floor Slab According to the Method for Evaluating the Tensile Performance of Steel Fiber Reinforced Concrete (강섬유 보강 콘크리트 인장성능 평가방법에 따른 지반 바닥슬래브의 설계)

  • Lee, Jong-Han;Cho, Baik-Soon;Cho, Chang-Oh
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.1
    • /
    • pp.95-104
    • /
    • 2016
  • Flexural strength of concrete ground slab reinforced with steel fiber is evaluated using the equivalent flexural strength ratio of steel fiber reinforced concrete based on the yield line theory. Recently, the European standard specifies that the tensile performance of the steel fiber reinforced concrete be evaluated directly from the residual flexural strength after the cracking of concrete. Thus, in the study, an experiment was carried out to evaluate the conventional equivalent flexural strength ratio and the residual flexural strength of the steel fiber reinforced concrete. Then the design flexural strength was investigated according to the location of a point load, based on the ratio of the radius of contact area of the load to the radius of relative stiffness. Design flexural capacity obtained from ACI 360R-10 was smaller than that from TR 34 (2003 & 2013). In addition, TR 34 (2013), which evaluates the design flexural capacity based on the residual flexural strength, showed slightly smaller value than TR 34 (2003).

Change of Needle Contact Angles due to Artificial Acid Rain Treatment (인공산성우 처리에 따른 침엽의 접촉각 변화)

  • Kim, Gab Tae
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.1
    • /
    • pp.32-37
    • /
    • 1994
  • Artificial acid rain(pH 3.0, 4.0 and 5.0) and ground water(pH 6.5) were treated on the potted seedlings of Pinus rigida and Pinus koraiensis to examine its effects on the contact angles on needle surface. Artificial acid rain was prepared by diluting sulfuric acid with ground water and ground water(pH 6.5) was used as control. Artificial acid rain was sprayed to the pots two times per week for growing season, one time per week for winter seasons. About 5mm of artificial acid rain was treated each time from late April, 1992 to early October, 1993. Contact angles on the needle surface were measured and compared among the treatments. The results were summarized as follows. Contact angles between needle surface and water droplet decreased with decrease of pH values of artificial acid rain. Measuring and comparing contact angles might be very effective criteria for early diagnosis of acid rain injury in the field.

  • PDF

A Study on Selection of Ultrasonic Transducer and Contact Material for Surface Irregularities of Stone Cultural Heritage (석조문화유산의 표면 요철도에 적합한 초음파 탐촉자 및 접촉매질 선정 연구)

  • Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.267-278
    • /
    • 2015
  • In this study, the elastomer cover, a new contact material, was developed to establish the customized ultrasonic measurement considering surface irregularities of stone cultural heritages. The cover exhibits high elastic force and wear resistance because it has tensile strength of 17MPa and elongation of 625%. In addition, as a result of comparative experiments for the seven types according to transducers and contact materials including the elastomer cover, rock surface irregularities significantly affect attenuation of ultrasonic velocity. The phenomenon was more noticeable in the chiseling finish and indirect transmission measurement rather than the dabbed finish and direct transmission measurement. However, the Type F using the exponential transducer and elastomer cover showed stable P-wave velocity and high amplitude regardless of the surface irregularities. This because the elastomer cover sufficiently sticks to surface irregularities and removes pores between a transducer and a rock specimen. Therefore, the Type F should be used for the ultrasonic measurement of stone cultural heritages with surface irregularities.

Evaluation on the Impact Resistant Performance of Fiber Reinforced Concrete by High-Velocity Projectile and Contacted Explosion (고속비상체 충돌 및 접촉폭발에 의한 섬유보강 콘크리트의 내충격 성능 평가)

  • Nam, Jeong-Soo;Kim, Hong-Seop;Lee, In-Cheol;Miyauchi, Hiroyuki;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.107-114
    • /
    • 2013
  • In this study we experimentally evaluated an impact resistant performance of fiber reinforced concrete in the moment of explosion by high-velocity projectile with emulsion explosive. To assess the impact resistance, we conducted the impact test of high-velocity projectile which reaches an impact speed of 350 m/s and the experiment of contact exploding emulsion explosive. As a result, bending and tensile performance depending on type of PVA, PE fiber (polyvinyl alcohol fiber, polyethylene fiber) and steel fiber affects destruction of rear side in the form of spalling. Destroying the backside of the concrete compressive strength compared to suppress the bending and tensile performance is affected. In addition, the experiment shows that the destruction patterns of concrete specimen producted by high velocity impact and contact explosion are significantly similar. Therefore, it is possible to predict the destruction patterns of specimens in the situation of contact explosion by high-velocity projectile.

Effect of Flexural Performance on U-Shaped Precast Concrete Beams with Noncontact Lapped Splice (비접촉 겹침 이음된 프리캐스트 U형 보의 휨성능에 미치는 효과)

  • Ha, Sang-Su;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.119-128
    • /
    • 2008
  • In this study, new moment-resisting precast concrete beam-column joint is proposed for moderate seismic regions. It has the connection reinforcing bars, penetrated the joint and lap-spliced with the bottom bars of precast U-shaped PC beam. To evaluate the performance for noncontact lapped splice, experimental and analytical works were conducted. Major variables for tests are the length of lap, the diameter of connection reinforcing bars, and the distance between lapped bars. Analytic research was performed nonlinear finite element method. Analytic research focused on crack pattern, load-deflection curve, comparison of internal force, evaluation of ductility strains of reinforcement bar. Results of experimental and analytical works show that the these variables has much influence on flexural strength and ductility, and joint behavior.

The Effect of Low Temperature Plasma Treatment Condition on the Peel Strength of EVA Foam for Shoe Mid-sole (저온플라즈마 처리조건이 신발 중창용 EVA 발포체의 접착력에 미치는 영향)

  • Park, C.C.;Park, C.Y.
    • Elastomers and Composites
    • /
    • v.35 no.4
    • /
    • pp.296-302
    • /
    • 2000
  • The surfaces of injection and pressure-molded sheets of poly(ethylene-covulylacetate)(EVA) foams used for shoe mid-sole were treated with low temperature plasma to improve adhesion with a water-based polyurethane adhesives. Several experimental variables were considered, such as radio frequency power, treating time, type of gas. gas flow, and distance between electrode and sample. The modificated surface by plasma treatment were characterized using contact angle meter, scanning electron microscopy(SEM), universal testing machine(UTM). Adhesion was tested by T-peel tests of treated EVA foams/polyurethane adhesive joints. The treatment in the low temperature plasma produced a noticeable decrease in contact angle. The peel strength of EVA foams treated with plasma was increased with plasma treating time, and gas flow.

  • PDF