• Title/Summary/Keyword: 접착부재

Search Result 51, Processing Time 0.029 seconds

Structural Behavior Evaluation of Mg-GFRP Composite Single-Lap Bonded Joints With Different End Shapes (한 끝단 형상에 따른 마그네슘 합금과 유리섬유 복합소재 단일겹치기 본드 조인트 거동 분석)

  • Kim, Jung-Seok;Im, Jae-Young;Lee, Woo-Geun
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.6
    • /
    • pp.391-396
    • /
    • 2014
  • In this study, the strength of magnesium-GFRP/epoxy single-lap bonded joints are experimentally evaluated with different end shapes. In order to achieve this, four different single-lap joints with different end shapes are fabricated and the failure load is measured under tensile loading tests. From the test results, the single-lap joint with a square end exhibits the lowest failure load while the single-lap joint with reverse tapering and a spew fillet has the highest stress values. It has 11.1% higher failure strength than the single-lap joint with a square end.

Damping Capacity of Finger-Jointed Lumber (손가락 결합부재의 감쇠거동)

  • Jang, Sang-Sik;Kang, Ho-Yang;Lee, Hwa-Hyoung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.43-50
    • /
    • 1994
  • 본 연구는 침엽수재를 사용한 손가락결합부재의 강도 및 감쇠특성을 측정함으로서 문창틀재로의 사용가능성을 시험하기 위하여 수행하였다. 손가락결합부 시험편의 형태는 손가락부분의 길이와 경사도에 따라서 다섯가지로 제작하였다. 하중은 4개의 하중단계를 갖는 양방향휨으로 가하였으며 각각의 하중단계는 3개의 하중주기로 구성되었다. 손가락결합부의 파괴특성을 분석하기 위하여 감쇠시험 과정에 AE신호를 측정하였다. MOE는 시험편의 형태와 뚜렷한 관련을 갖고 있지 않으나, MOR은 손가락부분의 경사도가 증가될수록 감소되는 뚜렷한 관계를 나타내었다. 감쇠비는 하중단계가 증가될수록 감소되었으나 파괴직전의 단계에서는 증가되는 경향을 나타내었다. 하중방향에 대하여 수직한 방향의 손가락결합부재가 수평방향부재보다 더 높은 강도를 나타내었다. 60dB 이상의 AE신호는 목재 또는 접착층의 파괴에 의하여 발생되는 것으로 분석되었다. 완전한 파괴가 발생하는 경우에는 100dB 이상의 AE신호가 발생하였다.

  • PDF

The Bond Characteristics of Ultra Rapid Hardening Mortar for Repair using Magnesia-Phosphate Cement (마그네시아 인산염 시멘트를 이용한 초속경 보수 모르타르의 접착특성)

  • Lee, Sun-Ho;Kwon, Hee-Sung;Paik, Min-Su;Ahn, Moo-Young;Lee, Young-Do;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.609-612
    • /
    • 2008
  • Ultra Super Early Strength Cement is a material that satisfies these requirements. early hydration heat however, is significant over regular concrete, thus discretion is advised for thermal cracks in accordance with heat generation when constructing a large-scale structures. In addition, the negative point that it is difficult to achieve required strength in a short period of time following rubbing process while retaining workability, the cement is being used conditionally for engineering material and Ultra Super Early Strength Cement for maintenance material for construction doesn't exist. Magnesia Phosphate Cement, which is currently under studies in overseas uses no extra admixture and has strong points of Ultra Super Early Strength as well as favorable construction-ability and adhesive stability to the prototype concrete. These factors stem recognition that it could be used as maintenance material for construction of diverse applicability. In order to provide necessary data to increase practicality of the magnesia phosphate cement for Ultra Super Early Strength Mortar, the study carried out simulate experiment on member of framework to review field applicability.

  • PDF

A study on a reasonable modeling method of fully grouted rockbolt (전면접착형 록볼트의 거동 특성을 고려한 합리적인 모델링 방법에 대한 연구)

  • Hong-Joo Lee;Kyung-Nam Kang;Ki-Il Song;Sang-Don Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.1
    • /
    • pp.19-37
    • /
    • 2024
  • Rockbolts are the primary-supports in NATM tunnels and are widely used at tunnel construction sites. Among the rockbolts methods applied in domestic tunnel design, fully grouted rockbolts are the most representative and frequently used. Fully grouted rockbolts exhibit relative behavior between the bolt and the ground due to the grout material. However, during numerical analysis for tunnel design, fully grouted rockbolts are often modeled in a way that does not reflect their behavior characteristics. This may result in underestimating or overestimating the force of the supports. Based on a literature review, it was analyzed that fully grouted rockbolts are modeled using truss element or cable element. To analyze the effect of grout properties of cable elements on rockbolts behavior, this paper compared the behavior of rockbolts in two models: one estimating grout properties based on rockbolt pull-out test data, and another assuming complete adhesion between the rockbolts and the ground by applying large grout properties. Under identical tunnel conditions, the numerical analysis was conducted by modeling the fully grouted rockbolts differently using truss and cable elements, and the tunnel behavior was analyzed. The research results suggest that modeling fully grouted rockbolts as a function of the interface effect between the bolts and the ground, specifically considering grout, is desirable. The use of pull-out test data to simulate the behavior of actual fully grouted rockbolts was considered as a valid approach.

Fracture Mechanical Characterization of Bi-material Interface for the Prediction of Load Bearing Capacity of Composite-Steel Bonded Joints (복합재료-탄소강 접착제 결합 조인트의 하중지지 능력 예측을 위한 이종 재료 접합 계면의 파괴 역학적 분석)

  • Kim, Won-Seok;Shin, Kum-Chel;Lee, Jung-Ju
    • Composites Research
    • /
    • v.19 no.4
    • /
    • pp.15-22
    • /
    • 2006
  • One of the primary factors limiting the application of composite-metal adhesively bonded joints in structural design is the lack of a good evaluation tool for the interfacial strength to predict the load bearing capacity of boned joints. In this paper composite-steel adhesion strength is evaluated in terms of stress intensity factor and fracture toughness of the interface corner. The load bearing capacity of double lap joints, fabricated by co-cured bonding of composite-steel adherends has been determined using fracture mechanical analysis. Bi-material interface comer stress singularity and its order are presented. Finally stress intensities and fracture toughness of the wedge shape bi-material interface corner are determined. Double lap joint failure locus and its mixed mode crack propagation criterion on $K_1-K_{11}$ plane have been developed by tension tests with different bond lengths.

Structural Performance and Fire Resistance Capacity of Inorganic Polymer Composites for Carbon Sheets Exposed to High Temperature (탄소섬유쉬트 보강 콘크리트용 무기계 폴리머 접착제의 내화 및 구조성능)

  • Chung, Lan;Park, Hyun-Soo
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.5
    • /
    • pp.109-115
    • /
    • 1998
  • 철근콘크리트 구조물이 과소설계되어 있거나 과다 하중이 작용하게 되면 그 구조물의 구조성능을 파악하여 보수.보강을 시행하게 된다. 최근에 가장 맣이 사용되는 보수.보강 재료로는 특히 휨내력을 보강하는데 탄소섬유를 들 수 있다. 탄소섬유쉬트는 내열성과 내호염성에 있어서 회재가 발생할 경우 보강재료로서 충분한 성능을 가지고 있다. 그러나 이를 접착시키는데 사용되는 에폭시는 유기계 물질로서 화재시 유독가스가 발생하고 내열성능도 30$0^{\circ}C$정도에도 지탱하기 어려워 화재 발생이 가능한 구조물에 사용하기 어렵다. 이 연구에서는 무기계 폴리머 복합재료로 접착된 탄소섬유를 고온(약 800~100$0^{\circ}C$, 1시간)으로 가열한 후 가열된 섬유판의 인장, 휨 전단내력을 검토하여 내열성능을 파악하고 이 섬유쉬트로 보강한 철근콘크리트 부재의 휨 성능을 실험적으로 규명하여 화재의 위험이 있는 구조물에 구조적인 보강재료로 사용이 가능한가를 검토하였다. 연구 결과, 개발된 무기계 폴리머 복합체는 인장강도, 휨강도 및 접착강도가 유기계 접착제와 유사하게 나타났고 800~100$0^{\circ}C$ 정도로 1시간 가열한 이후에도 상온 시험체 휨내력과 전단내력의 63%, 33% 정도를 유지하여 화재의 위험이 있는 부위에도 사용이 가능한 것으로 판단되었다.

Confined Effect of Concrete Compressive Members Strengthened with Carbon Fiber Laminate (탄소섬유판으로 횡보강된 콘크리트 압축부재의 보강성능)

  • Chung, Lan;Lee, Hee-Kyoung;Kim, Sung-Chul;Yoo, Seong-Hoon;Kim, Joong-Koo
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.345-352
    • /
    • 1998
  • Compressive strength of concrete compression members strengthend with carbon fiber laminate(CFL) were studied from the test results. Test parameters are spacing, thickness, width, ply and spliced length of carbon fiber laminates. Specimens strength with sheets failed with sudden tensile rupture of the laminate, which indicate very brittle failure mode. Test result shows that closer spacing and to increas thickness of CFL is more effective. But strengthening ratio with 1-ply CFL is more effective than that of specimen with 2-ply CFL. Compressive strength capacity of specimen splied 24cm shows almost similar strength to that of non-spliced specimen. The ultimate load carrying of specimen strengthened with CFL ranges 1.11~1.86 times of that of non-strengthened specimen.

Fire Resistance Property of RC Structure Member Strengthened with Fiber Sheet (섬유시트로 보강된 철근 콘크리트 구조부재의 방ㆍ내화성능)

  • 이한승
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.45-50
    • /
    • 2002
  • 근년, 철근 콘크리트조 구조부재의 열화 및 건축물의 용도변경에 따라 건축물의 보수 및 보강에 관한 공법의 개발 및 그 효과를 검증하려는 연구가 활발히 진행되고 있다. 이에 따라, 보강공법으로서는 경제성ㆍ시공성 면에서 우수한 탄소섬유시트, 아라미드섬유 시트, 유리섬유시트 보강공법 및 FRP판 보강공법 등 합성수지 접착제를 사용하는 새로운 보강공법들이 폭넓게 연구되어 현장 실용화되어 사용 중에 있다. 그러나, 이들 보강공법에 관한 연구는 주로 구조적인 내력 보강효과 산정에 관한 것이 대부분이고 보강후의 내화성능 및 내구성능에 관한 연구는 매우 부족한 실정이다. 이들 보강공법은 주로 에폭시수지계 접착제에 의하여 콘크리트와 보강재의 접착력에 의하여 내력이 전달되는 메커니즘으로 되어있어 화재가 발생한 경우 내화피복이 없다면 접착제 자체의 연소에 의하여 유독가스의 발생 및 접착강도가 크게 저하되어 그 구조적인 보강성능은 급속히 저하할 것으로 판단된다. 또한, 현재 이들 보강공사는 내화성능의 검토 없이 실제 시공이 이루어지고 있으므로 화재시에는 대형참사를 일으킬 위험성이 있다.(중략)

Study on Metal Plate Connections and Plywood Gusset Plate Connections for Light-Frame Wood Truss Tension Joint (목재 트러스 접합부의 toothed metal plate 접합과 plywood gusset plate 접합에 관한 연구)

  • Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.46-50
    • /
    • 1992
  • 본 연구는 잣나무 간벌재를 이용한 plywood gusset plate 접합과 toothed metal plate 접합에 대하여 인장력을 가해 조사하였다. plywood gusset plate 접합에 있어서는 합판과 부재 사이를 상온 경화제(초산 비닐 수지)로 접착한 후 6d 못으로 접합한 형태와 단지 합판만을 사용한 형태의 plywood gusset plate 접합 사이의 기계적 특성 차이를 조사했다. toothed metal plate 접합은 plywood gusset plate 접합보다 인장력에서 좋은 behavior를 보였다. 또한 접착제를 가한 plywood gusset plate 접합은 접합제를 가하지 않은 형태보다 큰 하중 지지력을 보였다.

  • PDF

Analytical Study on Interface Debonding of Reinforced Concrete Beams Strengthened with Carbon Fiber Sheet(CFS) (탄소섬유쉬트로 보강된 철근콘크리트보의 계면박리에 대한 해석적 연구)

  • Sim, Jong-Sung;Bae, In-Hwan
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.177-186
    • /
    • 1999
  • The purpose of this study is to analyze the interface debonding of RC beams strengthened by carbon fiber sheet(CFS). The behavior of damaged RC beams strengthened with CFS is analytically investigated next using linear elastic fracture mechanics(LEFM) approach and the finite element method. The study includes an investigation of the separation mode by interface fracture of the strengthening materials due to the interfacial shear and normal stresses. The numerical method is presented to obtain the value of interfacial fracture parameter such as the strain energy release rate. Based on the results of this study, it is found that the critical case occurs when the interfacial cracks occur within a short region of the flexural crack. The CFS strengthening has not an adequate factor of safety against interfacial debonding of CFS. Furthermore, for the thicknesses of the adhesive studied[1mm~3mm], it is no noticeable effect on the strain energy release rate.