• Title/Summary/Keyword: 점화 성능

Search Result 257, Processing Time 0.028 seconds

Performance and Emission Comparisons of a SI Engine Fueled by Syngas with Varying Hydrogen Content (합성가스 연료의 수소 함량 변화가 SI 엔진의 연소특성에 주는 영향)

  • Park, Seung-Hyun;Lee, Sun-Youp;Park, Cheol-Woong;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.63-68
    • /
    • 2011
  • As an effective utilization of biomass, organic wastes and coal, attention has been made to use syngas to a reciprocating engine to generate power. However, significant component variation of syngas depending upon origin and gasification conditions, and its lower heating value than that of LPG and CNG can create difficulties in stable engine operation. Thus it is necessary to address these issues in order to successfully develop power generation engines. As a primary step to resolve these problems, effects of H2 content variation in syngas on engine performance and emission characteristics were discussed in this study. The results show that as H2 % in syngas increases, more stable combustion was achieved with retarded MBT spark timing and engine efficiency becomes maximum with syngas of 10% H2. In addition, NOx emission increased while THC emission decreased as H2 % rises in the syngas.

Study of Gas-turbine Cranking Model using the Coast Down Experimental Results (Coast Down 시험데이터를 이용한 가스터빈엔진 시동모델 연구)

  • Kim, Sun Je;Kim, Yeong Ryeon;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.18-24
    • /
    • 2017
  • Appropriate selection of the starter is essential for successful starting of the gas-turbine engine. Thus, aerodynamic drag during starting phase should be analyzed to assess the feasibility of the starter. In this paper, aerodynamic drag is modeled based on the speed profile from the engine coast down test, and it is scaled with respect to the target engine by comparing the compressor load. Afterward, the govern equation of the starting phase is developed with the torque model of the starter, and the design scheme to select the feasible starter will be finally suggested. The proposed model of starting phase will be useful to perform a preliminary design of the starting system of the gas-turbine engine.

Study on the Performance of a Spark Ignition Gas Engine for Power Generation fueled by the Methane/Syngas Mixture (메탄/합성가스 혼합물에 의한 발전용 SI 가스엔진의 성능에 관한 연구)

  • Cha, Hyoseok;Hur, Kwang Beom;Song, Soonho
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.7-12
    • /
    • 2015
  • Hydrogen is usually produced by using syngas generated by the fuel reforming for natural gas so far. The further process is needed for increasing the hydrogen yield of syngas. However, the process for upgrading the hydrogen yield is accompanied by additional energy sources and economic costs. Thus related studies on the method for using as a mixture in itself have been conducted in order to utilize more efficiently syngas. The effect on the engine performance for methane/syngas mixture of 30kW spark ignition gas engine for power generation has been investigated in this study. As a result, it was found that the combustion phenomena such as the maximum in-cylinder pressure and crank angle at that time have been improved by methane/syngas mixture. Through these, fuel conversion efficiency could be enhanced by about 98% of methane/hydrogen mixture and $NO_x$ emissions could be reduced by about 12% of methane-hydrogen mixture.

Effects of CNG Heating Value on Combustion Characteristics of a Diesel-CNG Dual-Fuel Engine (디젤-CNG 혼소엔진에서 CNG 발열량 변화가 연소 특성에 미치는 영향)

  • Kim, Yongrae;Jang, Hyeongjun;Lee, Janghee;Kim, Changgi
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.28-33
    • /
    • 2015
  • In this study, a dual fuel engine fueled with natural gas and diesel was tested to investigate the effects of heating value variation of CNG fuel. CNG substitution rate which is defined as the ratio of CNG and diesel supplied in a heating value basis was fixed at 80%. The higher heating value was varied from $10,400kcal/Nm^3$ to $9,400kcal/Nm^3$ by mixing nitrogen gas with pure CNG and diesel fuel was injected at a fixed injection timing. The engine test results showed that thermal efficiency and power output were decreased as the heating value of mixed CNG fuel was decreased. And the peak cylinder pressure was also decreased but the ignition delay time and the combustion duration and timing were almost same.

A Study on the Performance of Catalysts for the Recombination of Oxyhydrogen Gas Generated in Secondary Battery (이차전지내 발생하는 수소-산소 혼합기체 재결합용 촉매의 성능 측정 및 이론적 모델 연구)

  • Kim, Yong-Sik;Chang, Min-Hwan;Ju, Jeh-Beck
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 2014
  • The performance of catalysts for the recombination of oxyhydrogen gas was measured and compared with the results obtained from theoretical model. The oxyhydrogen gas was generated by the electrolysis cell and recombined through the fixed bed catalytic reactor. The yield that is the ratio of water-amount produced to the water-amount consumed in the electrolysis cell was increased with the increase of KOH concentration in electrolysis cell and the applied current. The catalyst 1 showed the best performance and the yield was under 60 %. The faradic yield calculated by Faraday's law showed about 100% in maximum with catalyst 1. The production rate of water generated by the recombination was 5-40 g/day dependent on the flow rate of mixed gas. Considering the results calculated from the pseudo-homogeneous catalytic reactor model, the hot point inside the reactor was moved to the direction of outlet and the maximum temperatures were $440-480^{\circ}K$ when the gas flow rate increased. The production rate of water calculated from the theoretical model showed good agreement with experimental results below the flow rate of $0.5cm^3/sec$, but there were much differences above that flow rate.

Electricity Generation and Microbial Community variation in Microbial Fuel Cell with various Electrode Combinations. (다양한 탄소전극조합에 따른 미생물 연료전지의 전기발생량 및 미생물 군집변화)

  • Kwon, Jae-Hyeong;Choi, Soo-Jung;Cha, Jae-Hwan;Kim, Hyo-Soo;Kim, Ye-Jin;Yu, Jae-Cheul;Kim, Chan-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.87-96
    • /
    • 2010
  • The electrode material is one of the factors affecting the power production of microbial fuel cell. In this study, effects of carbon electrode material, thickness and configuration on the power density, biofilm formation and microbial community diversity of microbial fuel cell were investigated. To optimize the anode-cathode electrode assembly, seven lab-scale reactors which had various carbon electrode constructions were operated in continuous mode. Under the steady state condition, the electrode combination of graphite felt (6 mm) with hole showed the highest cell voltage of 238 mV and the coulombic efficiency of 37%. As a result of SEM analysis, the bacteria growing on surface of knitted type of carbon cloth and graphite felt electrode ncreased significantly. The change of dominant species between seeding sludge and biofilm on the surface of anode electrode, microbial analysis with PCR-DGGE showed that the dominant species of seeding sludge are quite different from those of biofilm on the surface of each anode electrode. Especially Geobacter sp., a well known electrochemical bacteria, was found as the dominant species of the electrode combination with graphite felt.

Research on Fire Safety of Mortar-Containing Waste Tire Powders and Flame Retardant (폐타이어 분말과 난연제가 혼입된 모르타르의 화재안전에 관한 연구)

  • Park, Jeong-Jin;Son, Ki-Sang
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.12-17
    • /
    • 2010
  • The purpose of this study is to determine how effectively waste tire recycled material mixed with flame retardant work in combating fire. As discovered in the previous study, waste tire mixed with cement mortar has more insulation capacity. However, this mortar is weak against fire. Therefore flame retardant, with a specific proportional mix, will be added to increase its fire prevention capacity. Tests will be made in accordance with ISO 5657 procedures for measuring fire ignition time, flame and shape variation of test pieces at the Building Material Test Institute. The test piece will be set up with horizontal levels having a constant radiation heat of $1{\sim}5W/cm^2$. Temperature transfers and increases from the surface into the interior. Combustible gases result due to pyrolysis, and regular contact is maintained between the fire source and the center of the test piece for assessment purposes. Ignition has not been occurred without adding retardant meaning that there is almost no possibility of ignition of waste tire particle. This fact can be considered as fire load to appreciate a volume of combustion materials. Flame is not occurred due to heat-absorbing effect by adding non-organic series retardant into waste tire particle. Conclusions have been summarized as follows; 1) Combustion of building material can be decreased by adding retardant to waste tire-mixing mortar. But compressive strength and insulation capacity of the material should be measured later. 2) Firing prevention and ignition are main points of building fire. Reasonable fire engineering assessment of interior material should be made for establishing effective disaster prevention system.

Advanced Wastewater Treatment on ship's sewage with new MARPOL73/78 ANNEX IV (MARPOL73/78 ANNEX IV의 개정발효에 따른 선박 오수의 고도처리)

  • Park, Sang-Ho;Lim, Jae-Dong;Park, Sung-Jeng;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.91-96
    • /
    • 2007
  • Lab scale experimental study was carried out for SBR process, to investigate the effects of influent ship sewage organic compound removal and Bacillus sp. state on design parameters. This process was able to remove nitrogen and phosphorus as well as organic matter efficiently. More than 95% of chemical oxygen demand(COD) were removed. In addition, about 97% of total nitrogen (T-N) was reduced. The total phosphorus(T-P) reduction averaged 93%. The performance load of SBR process was shown to be $0.095kg{\cdot}TOC/m^3{\cdot}day$. The pH was decreased from 8.1 to 7.0 within 30 min and increased to 7.3 at the end of anoxic stage, and these phenomena were explained. The sludge produced in the SBR process is characterized by low generation rate (about $0.36kg{\cdot}MLSS/kg{\cdot}TOC$) and excellent settleability. The number of Bacillus sp. in the SBR was 24.2%, indicating that Bacillus sp. was a predominant species in the reactor.

  • PDF

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

Combustion Characteristics of Land Fill Gas according to the Diameter of the Flame outlet of the Pre-chamber Spark Plug (예연소실 점화 플러그의 화염 분출구 직경에 따른 매립지가스의 연소 특성)

  • Kim, Kwonse;Jeon, Yeong-Cheol;Choi, Doo-Seuk
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.7
    • /
    • pp.111-117
    • /
    • 2021
  • This research work is to suggest the experimental results capable of solving an initial unsuitability of combustion and environment in a constant volume combustion chamber by using LFG(Land Fill Gas) which consists of 40% CO2 and 60% CH4. The experimental condition is set as 0.9~1.6 of air-fuel ratio, 3bar of combustion pressure, 25℃ of room temperature, methane for using gas, and 2.5~4.5 of Pre-chamber hole sizes. As a result, it can be seen that diffusion of initial flame is significantly increased by M3.0 model comparing with other one. The reason for the characteristics is that orifice effect is extremely improved by 0.9, 1.0, and 1.2 of air-fuel ratio comparing with other one. Consequently, this experiment is shown that M3.0 model is partially capable of improving combustion performance than a conventional ignition plug in case of applying to LFG with Pre-chamber design.