• Title/Summary/Keyword: 점화원

Search Result 188, Processing Time 0.026 seconds

Experimental Investigation of Steam Plasma Characteristics for High Energy Density Metal Powder Ignition Using Optical Emission Spectroscopy Method (OES 방법을 이용한 고에너지 금속 분말 점화용 스팀 플라즈마 특성에 관한 실험적 고찰)

  • Lee, Sang-Hyup;Ko, Tae-Ho;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.545-550
    • /
    • 2012
  • High Energy density metal powder has high melting point of oxide film. By this, the ignition source that can make a thermal effect of high-temperature during short time is needed to overcome ignition disturbance mechanism by oxide film. So effective ignition does not occurred with hydrocarbon ignitor, $H_2-O_2$ ignitor, high power laser. But steam plasma can be generate about 5000 K temperature field in short order. Because a steam plasma uses steam as the working gas, it is environmental-friendly and economical. Therefore in this study, we analyze steam plasma temperature field and radical species with optical emission spectroscopy method in order to apply steam plasma ignitor to metal combustion system and cloud particle ignition was identified in visual.

  • PDF

Ignition Characteristics of Aluminum Metal Powder Fuel with Thermal Plasma (플라즈마를 이용한 분말형 금속 연료 알루미늄의 점화 특성)

  • Lee, Sang-Hyup;Lim, Ji-Hwan;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.737-744
    • /
    • 2011
  • The success of continuous aluminum powder combustion with steam plasma is different from hydrocarbon ignition source. Ignition characteristics of aluminum powder with high temperature thermal plasma is studied with oxidizer-free environment. Experiment with argon plasma has same temperature conditions at 4500 K and particle feeding condition for previous combustion test with steam plasma and swirl combustor. The temperature of the plasma was measured using Optical Emission Spectroscopy method. Ignition characteristics were analyzed by SEM image and EDS. Aluminum powder with plasma has rapid evaporation mechanism contrast to hydrocarbon ignition source. It enhances to aluminum powder effective ignition characteristics.

  • PDF

Partial Discharge of Ignition Coil for Automotive (자동차 점화코일의 부분방전특성)

  • Shin, Jong-Yeol;Kim, Tag-Yong;Byun, Du-Gyoon;Kim, Weon-Jong;Lee, Soo-Won;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.239-242
    • /
    • 2003
  • 자동차 점화장치는 전원으로부터 공급된 낮은 전압을 점화코일을 통하여 연소실의 혼합기를 연소시키기에 충분한 고전압을 발생시키는 장치이며, 점화장치의 핵심은 점화코일이다. 이 점화코일은 절연성능이 우수한 절연재료가 사용되지만 고전압의 발생으로 점화코일 내부에서 일어나는 전기적 열화로 인해 누설전류가 흐르게 되어 전기적 고장을 초래할 수 있다. 이로 인하여 절연재료의 수명은 단축되며, 또한 점화코일에 전류가 흐름으로써 코일 내부에서 발생하는 온도변화에 따른 절연열화로 점화코일의 성능이 저하될 수 있다. 따라서 본 연구에서는 점화코일에 사용되고 있는 절연재료에 전압이 인가될 때 발생할 수 있는 비파괴검사의 일종인 부분방전 측정을 통하여 전압변화에 따른 에폭시 성형 점화코일의 위상각($\Phi$) - 방전전하량(q) - 발생빈도수(n)의 특성 변화를 조사하고 분석함으로써 점화코일의 수명을 예측하여 자동차 점화장치의 성능진단과 정보제공을 자동차 전기장치의 발전에 도움이 될 것을 기대하며, 온도상승에 따른 점화코일의 부분방전 특성을 실험하고 분석하였다.

  • PDF

액체 로켓 엔진에 있어서 추진제 공급 선점 시간이 점화 특성에 미치는 영향

  • Kim, Young-Han;Kim, Yong-Wook;Lee, Jae-Ryong;Park, Jung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.1-1
    • /
    • 2000
  • 액체로켓엔진에 있어서 연소실로 공급된 추진제의 안정적인 점화를 위해 추진제 공급의 선점 시간을 결정하기 위한 실험이 수행되었다. 사용된 추진제는 Jet A-1과 액체 산소이고 추진제의 공급은 가압 방식이다. 135$^{\circ}$의 각을 갖고 배열된 인젝터는 FOOF 타입의 비동류형 충돌형 인젝터이고 연소실 압력이 200psi가 되도록 설계되었다. 현재의 실험은 점화원으로서 TEAL(triethylaluminum)을 사용하여 쿼드렛 타입의 점화기의 안정적 점화 여부를 검증하는 것도 포함된다. 점화 특성 파악을 위해 인젝터 상류의 매니폴드 압력, 연소실 압력이 측정되었고 점화 과정 및 정상 상태로의 천이 과정에 대한 간접적 증거로서 화염 길이가 측정되었다.

  • PDF

Fire at an Indoor Shooting Range in Busan II. Causes and Fire Safety Measures (부산 실내사격장 화재 II. 원인 및 화재안전대책)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.92-97
    • /
    • 2010
  • Fire simulation by using a computational fluid dynamics model and examination of the fires at indoor shooting ranges broken out in the past were conducted, to presume causes of the fire at the indoor shooting range in Busan and suggest fire safety measures. On-site investigations and shooting tests on unburned gunpowder were also carried out. No trace of the muzzle spark and spark at the bullet trap was found in CCTV footage, and the impact of a stray bullet failed to ignite gunpowder. Cigarette was therefore presumed to be the most likely source of ignition among the potential sources. It appeared that the explosion in the shooting area was caused by violent burning of the polyurethane sound absorber and unburned gunpowder accumulated on it. The fire safety measures include prohibit of use of profile polyurethane sound absorber, removal of steel components from bullet trap, clean up and control of unburned gunpowder, etc.

Study of the Risk of Ignition due to Internal Combustion Engines in Areas with Potentially Explosive Gas Atmospheres (잠재적 폭발위험장소에서 내연기관에 의한 점화 위험성에 관한 연구)

  • Kim, Yun Seok;Rie, Dong Ho
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.1-8
    • /
    • 2016
  • Safety management in hazardous areas with potentially explosive gas atmospheres (here in after referred to as hazardous areas) in large scale facilities dealing with combustible or flammable materials at home and abroad is very important (significant) for the coexistence of the company and local society based on business continuity management (BCM) and reliance. For the safety management in hazardous areas, two systems are mainly used: (1) the control system for the prevention of combustible or flammable substances and (2) the explosion proof system for the elimination of ignition sources when flammable gases are leaked to inhibit the transition to fire or explosion accidents. While technology and regulations on explosion proof facilities or devices for electrical ignition sources are well developed and defined, those for thermal ignition sources need to be more developed and established. In this study, the internal combustion engine in hazardous areas was investigated to determine the risk of ignition. For this purpose, document searches were conducted on the relevant international standards and accidents cases and risk analysis reports. In addition, this study assessed the application cases of the diesel engine's safety equipment, such as spark arresters regarding the site of process safety management (PSM) system in central Korea. To practically apply these results to the hydrocarbon industry, the safety management method for explosion prevention in hazardous areas was provided by risk identification for ignition sources of internal combustion engines, such as diesel engines.

Emotional Decision-Making (정서적 의사결정)

  • 이수정
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.262-270
    • /
    • 1999
  • 본 연구에서는 정서의 처리가 어떤 과정을 거쳐 이루어지는지를 조사하였다. 정서의 우선성 효과를 알아보기 위하여 제작되었던 Murphy와 Zajonc(1993)의 실험 패러다임을 응용하여 비의식적인 수준에서의 정서점화효과와 의식적인 수준에서의 정서점화효과를 비교하였다. 정서적 경험에 있어서의 차별화를 조작하기 위하여서 실험 2에서는 실험 1에서 사용되었던 표정사진 대신 사건사진을 점화자극으로 사용하였다. 실험 1과 실험 2에서 모두 식역 이하 수준에서 점화자극을 제시하였던 경우 Murphy와 Zajonc(1993)이 발견한 점화자극으로 인한 동화의 효과가 나타났다. 원 연구자들에 따르자면 점화자극에 대한 자각은 점화자극으로 인한 동화효과를 상쇄하여야 한다. 그러나 자극제시시간을 정서적 각성이 충분히 일어나도록 길게 한 조건에서는 사건사진(실험 2)만이 정서적 동화효과를 산출하였다. 마지막으로 이런 결과들이 지니는 정서처리의 과정에 대한 시사점이 논의되었다.

  • PDF

A Study on Noise of Detonator and Explosive Initiation on Ground Surface (지표면에서 뇌관과 폭약 폭발 소음에 관한 연구)

  • 기경철;김일중;원연호;김영근
    • Explosives and Blasting
    • /
    • v.21 no.3
    • /
    • pp.73-80
    • /
    • 2003
  • 암반발파에 사용하고 있는 전기식 뇌관과 비전기식 연결뇌관 및 번치 커넥터(Bunch connector), 점화구, 에멀젼류 폭약이 지상에서 기폭 될 때 발생하는 소음을 비교 분석하였다. 에멀젼류 폭약의 폭발소음과 화공품의 기폭소음에 대한 추정식을 도출하였다. 에멀젼류 폭약의 폭발 소음 예측은 반대수 자승근 환산식, 번치 커넥터, 전기식 뇌관 및 비전기식 연결뇌관 및 점화구는 전대수식이 적합한 것으로 판단된다. 소음원으로부터 동일한 거리에서의 소음은 점화구, 비전기식 연결뇌관, 전기식 뇌관 및 번치 커넥터 순으로 높았다. 소음원으로부터 약20∼30m거리의 범위에서 번치 커넥터의 기폭소음은 에멀젼류 폭약 0.250kg의 폭발소음보다 약15.6∼20.2dB(A) 낮고, 비전기식 연결뇌관 보다 약13.5∼16.0dB(A) 높고, 전기식 뇌관 보다는 약6.5∼7.5dB(A) 높게 됨을 알 수 있었다. 점화구는 약20m 거리에서 약 7dB(A)이하 이었다. 에멀젼류 폭약의 폭발과 번치 커넥터의 기폭소음에 미치는 주(主)소음원은 에멀젼류 폭약의 약량과 번치 커넥터의 도폭선임을 확인하였다.

Flame Standing of Magnesium-Steam in Swirl Combustor (와류 연소기에 의한 Mg-Steam 화염 안정화)

  • Ko, Tae-Ho;Lee, Sang-Hyup;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.139-143
    • /
    • 2011
  • 금속분말을 청정 에너지원으로 이용하기 위해 금속분말 소형 연소기의 구현이 필요하다. 이를 위한 기초 연구로서 점화성이 뛰어나면서도 경제적인 수십 마이크로 크기의 마그네슘(Mg) 분말을 대상으로 고온 증기(steam)와의 연소 현상 대해 연구하였다. 본 연구에서는 연소실 내 체류시간 및 혼합 효율을 증가시키기 위해 와류 유동을 연소기에 적용하였고 아르곤(Ar) 이송가스를 이용해 마그네슘 분말을 공급하였다. 안정한 화염을 유지시키기 위하여 이송가스의 유량을 변화시켜 공급되는 마그네슘의 양을 조절하였고, 고온 증기의 공급량은 니들 밸브의 개도를 조정하거나 우회시킨 관로로 증기의 일부를 배출함으로써 조절하였다. 고온의 점화원을 사용하여 증기 분위기 내 마그네슘 분말을 점화시켜, 대기압 환경에서 마그네슘/증기/아르곤의 지속적인 화염을 구현하였다.

  • PDF

전기화재 원인과 발생②

  • 김미승
    • Electric Engineers Magazine
    • /
    • v.244 no.12
    • /
    • pp.29-32
    • /
    • 2002
  • 화재는 발생원인, 연소대상물, 점화원의 형태등 다양한 메커니즘에 의해 매우 복잡하고 다양하게 진행되기 때문에 분류한다는 것이 쉬운 문제는 아니다. 그러나 여기서는 국내외 소방대상물에 의한 화재분류에 따라 분류한다.

  • PDF