• 제목/요약/키워드: 점성침투깊이

검색결과 3건 처리시간 0.015초

1/4파장 열음향 냉동기의 공명관 길이 의존 특성 연구 (An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/4 wave)

  • 송규조;박종호;고득용;박성제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.229-234
    • /
    • 2001
  • The thermoacoustic refrigerator bas not only considerable possibility but also commercial usability, because it bas high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying length of the resonance tube to 400mm, 500mm, 600mm, 700mm. In order to determine the optimum resonance tube length and the frequency, the $\lambda/4$ thermoacoustic engine and the similar apparatus of Wheatly type refrigerator were constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $56.3^{\circ}C$ at 626Hz in 400mm tube with 40mm stack.

  • PDF

1/2파장 열음향 냉동기의 공명관 길이 의존 특성 연구 (An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/2 wave)

  • 송규조;박종호;고득용;김효봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.217-222
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying the length of Resonant Tube to 400mm $\sim850mm$. In order to determine the optimum position of stack in the resonance tube and the frequency, the simple $\lambda/2$ thermoacoustic refrigerator was constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $52.6^{\circ}C$ at 827Hz in 400mm tube with 40mm stack.

  • PDF

2 상 유동장에 놓인 열 교환기 튜브에 작용하는 점성과 압착막 감쇠비의 어림적 해석 모델 (Approximate Model of Viscous and Squeeze-film Damping Ratios of Heat Exchanger Tubes Subjected to Two-Phase Cross-Flow)

  • 심우건
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.97-107
    • /
    • 2015
  • 2 상 유동장에 놓인 열 교환기 튜브에 작용하는 점성 감쇠비와 압착막 감쇠비를 예측하기 위한 해석 모델이 개발되었다. 열 교환기 튜브에 작용하는 유동유발진동을 해석하기 위하여 감쇠에 대한 정보가 요구된다. 열 교환기 튜브에서 가장 중요한 에너지 소산 기구는 튜브와 지지물과 같은 구조물과 액체 사이의 동적 작용에 연계되어 있다. 본 모델은 1997 년 발표된 근사모델에 근거하고 부가질량계수를 고려하여 개발되었다. 어림적 해석모델은 동심환 내에서 진동하는 내부 실린더에 작용하는 수력학적 힘을 계산하기 위하여 개발되었다. 점성력을 포함한 수동력은 높고 혹은 낮은 진동 레이놀드 수에 따라 개발된 두 가지 모델을 사용하여 각각 계산할 수 있다. 관군과 지지대에서의 상당 직경과 침투깊이는 관군에 작용하는 점성 감쇠력과 지지대에서의 압착막 감쇠력을 각각 계산하는데 매우 중요한 변수이다. 2 상 유동의 기공률을 계산하기 위하여 균질모델이 사용되었다. 본 모델을 검증하기 위하여, 모델의 해석결과는 기존의 이론으로 구한 결과와 비교하였다. 본 모델을 사용하여 점성 감쇠비와 압착막 감쇠비를 어림적으로 구할 수 있음을 보였다.