• Title/Summary/Keyword: 절차의보정

Search Result 38, Processing Time 0.024 seconds

Analysis of Repeated Measurement Problem in SP data (SP 데이터의 Repeated Measurement Problem 분석)

  • CHO, Hye-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.1
    • /
    • pp.111-119
    • /
    • 2002
  • One of the advantages of SP methods is the possibility of getting a number of responses from each respondent. However, when the repeated observations from each respondent are analysed by applying the simple modeling method, a potential problem is created because of upbiased significance due to the repeated observation from each respondent. This study uses a variety of approaches to explore this issue and to test the robustness of the simple model estimates. Among several different approaches, the Jackknife method and Kocurs method were applied. The Jackknife method was implemented using a program JACKKNIFE. The model estimate results of Jackknife method and Kocurs method were compared with those of the uncorrected estimates in order to test whether there was repeated measurement problem or not and the extent to which this problem affected the model estimates. The standard errors between the uncorrected model estimates and Jackknife estimates were also compared. The results reveals that the t-ratios of Kocurs are much lower than those of the uncorrected method and Jackknife estimates, indicating that Kocurs method underestimates the significance of the coefficients. Jackknife method produced the almost same coefficients as those of the uncorrected model but the lower t-ratios. These results indicate that the coefficients of the uncorrected method are accurate but that their significance are somewhat overestimated. In this study. 1 concluded that the repeated measurement Problem did exist in our data, but that it did not affect the model estimation results significantly. It is recommended that such a test should become a standard procedure. If it turns out that the analysis based on the simple uncorrected method are influenced by the repeated measurement problem. it should be corrected.

Exhaust Plume Behavior Study of MMH-NTO Bipropellant Thruster (MMH-NTO 이원추진제 추력기의 배기가스 거동 해석 연구)

  • Kim, Hyeonah;Lee, Kyun Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.300-309
    • /
    • 2017
  • A spacecraft obtains a reaction momentum required for an orbit correction and an attitude control by exhausting a combustion gas through a small thruster in space. If the exhaust plume collides with spacecraft surfaces, it is very important to predict the exhaust plume behavior of the thruster when designing a satellite, because a generated disturbance force/torque, a heat load and a surface contamination can yield a life shortening and a reduction of the spacecraft function. The purpose of the present study is to ensure the core technology required for the spacecraft design by analyzing numerically the exhaust gas behavior of the 10 N class bipropellant thruster for an attitude control of the spacecraft. To do this, calculation results of chemical equilibrium reaction between a MMH for fuel and a NTO for oxidizer, and continuum region of the nozzle inside are implemented as inlet conditions of the DSMC method for the exhaust plume analysis. From these results, it is possible to predict a nonequilibrium expansion such as a species separation and a backflow in the vicinity of the bipropellant thruster nozzle.

A Study on the Systematic Integration of WASP5 Water Quality Model with a GIS (GIS와 WASP5 수질모델의 유기적 통합에 관한 연구)

  • 최성규;김계현
    • Spatial Information Research
    • /
    • v.9 no.2
    • /
    • pp.291-307
    • /
    • 2001
  • In today's environmental engineering practice, many technologies such as GIS have been adopted to analyze chemical and biological process in water bodies and pollutants movements on the land surface. However, the linkage between spatially represented land surface pollutants and the in-stream processes has been relatively weak. This lack of continuity needs to develop a method in order to link the spatially-based pollutant source characterization with the water quality modeling. The objective of this thesis was to develop a two-way(forward and backward) link between ArcView GIS software and the USEPA water quality model, WASP5. This thesis includes a literature review, the determination of the point source and non-point source loadings from WASP5 modeling, and the linkage of a GIS with WASP5 model. The GIS and model linkage includes pre-processing of the input data within a GIS to provide necessary information for running a model in the forms of external input files. The model results has been post-processed and stored in the GIS database to be reviewed in a user defined form such as a chart, or a table. The interface developed from this study would provide efficient environment to support the easier decision making form water quality management.

  • PDF

Quantitative Comparison of Motion Artifacts in PET Images using Data-Based Gating (데이터 기반 게이팅을 이용한 PET 영상의 움직임 인공물의 정량적 비교)

  • Jin Young, Kim;Gye Hwan, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.91-98
    • /
    • 2023
  • PET is used effectively for biochemical or pathological phenomena, disease diagnosis, prognosis determination after treatment, and treatment planning because it can quantify physiological indicators in the human body by imaging the distribution of various biochemical substances. However, since respiratory motion artifacts may occur due to the movement of the diaphragm due to breathing, we would like to evaluate the practical effect by using the a device-less data-driven gated (DDG) technique called MotionFree with the phase-based gating correction method called Q.static scan mode. In this study, images of changes in moving distance (0 cm, 1 cm, 2 cm, 3 cm) are acquired using a breathing-simulated moving phantom. The diameters of the six spheres in the phantom are 10 mm, 13 mm, 17 mm, 22 mm, 28 mm, and 37 mm, respectively. According to maximum standardized uptake value (SUVmax) measurements, when DDG was applied based on the moving distance, the average SUVmax of the correction effect by the moving distance was improved by 1.92, 2.48, 3.23 and 3.00, respectively. When DDG was applied based on the diameter of the phantom spheres, the average SUVmax of the correction effect by the moving distance was improved by 2.37, 2.02, 1.44, 1.20, 0.42 and 0.52 respectively.

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

The variability of 6-D Skull Tracking(6DST) in Cyberknife for Bone metastasis patients (사이버나이프 6-D Skull Tracking의 유용성 평가)

  • Lee, Geon Ho;Bae, Sun Myeong;Song, Heung Kwon;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.41-47
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate the usefulness of 6 Dimensional Skull Tracking(6DST) in Cyberknife Stereotactic Body Radiation Therapy(SBRT) for the first and second cervical vertebrae(C1 and C2) metastasis. Methode and material : The Computed Tomography (Lightspeed VCT 64, General Electric Co. Waukesha, WI, USA) was used to acquire the CT images of the 9 patients with cervical vertebrae(C1 and C2) metastasis. Treatment plans for Xsight spine tracking and 6 Dimensional skull tracking were established with planning system (Multiplan system Version 4.6, Accuray, US). The results of XST and 6DST for each patient were analyzed with Microsoft Excel 2010. Result : The Maximum offsets of XST for C1 were 0.9 mm in Y(supero-inferior), 0.9 mm in Z(antero-posterior), 0.7 mm in X(left-right) direction, and rotations were and 1.0 degrees roll, 1.0 degrees pitch and 1.2 degrees yaw. The Maximum offsets of 6DST for C1 were 0.7 mm, 0.7 mm, 0.9 mm and $1.0^{\circ}$, $1.0^{\circ}$, $1.2^{\circ}$ for Y, Z, X and Roll, Pitch, Yaw. The Maximum offsets of XST and 6DST for C2 were 0.7 mm, 0.7 mm, 0.8 mm and $0.9^{\circ}$, $1.0^{\circ}$, $1.8^{\circ}$, and 0.9 mm, 0.7 mm, 0.9 mm and $0.9^{\circ}$, $0.9^{\circ}$, $1.0^{\circ}$ for Y, Z, X and Roll, Pitch, Yaw, respectively. Conclusion : XST and 6DST showed identical results for translations and rotations within the tolerance. It is possible to simplify the treatment time and procedure by using the 6DST. Therefore, 6DST is very useful methode with XST among the various tracking methods in Cyberknife for the patients with C1, C2 vertebral metastasis.

  • PDF

The Melodic Structure of the Bulmosan Youngsanjae, Ongho-ge (불모산 영산재 범패 옹호게의 선율구조)

  • Choi, Heon
    • (The) Research of the performance art and culture
    • /
    • no.34
    • /
    • pp.383-421
    • /
    • 2017
  • Because the Jitsori and the Hotsori of the Beompae(the Korean Budhhist chant) has no meter and no Jangdan(a Rhythmic cycle of the Korean Music), so it is hard to analyze the melody of the Beompae. Also the melody of the Beompae is different from that of the other Korean traditional music, so studying of the Beompae has been out of the limelight of many scholars, studying the Korean music. But the melody of Beompae had been handed down for thousands of years in Korea, it and other Korean trditional music, had exchanged the impacts each other for a longtime. So I thinks that the Korean Beomapae have shared the similarity of the musical features with the other Korean traditional music. Because the Beompae of the Bulmosan Yeongsanjae on the Geongsangnamdo province has also no meters and no Jangdan, it is difficult to understand, too. But because the Onghoge of Bulmosan Yeongsanjae have a well-regulated melodic structure in comparison with the Beompae of the Seoul province, so called Geongjae Beompae, it seem to be easy to analyze its melody. So I will analyze the melody of Bulmosan Yeongsanjae Onghoge. This analyze should be contribute to investigate the rule of the melodic progress method on the convoluted Beompae melody. Onghoge has been sung on the procedure for Siryeon, Samsiniun(Goebuliun), Jojeonjeoman, Sinjungjakbeop. And the monk for the ritual has sung the chant first to purify the ritual place and to protect the soul. They has called the song, Onghoge a Jitsori at the Bulmosan Yeongsanjae preservation society of the Gyeongnam province. Commonly, there were Jitsori and Hotsori in the Beompae melody, and the melody of Jitsori is longer than that of the Hotsori. So, the melody of Onghoge is lengthened. In other word, the melody of the Onghoge show the lengthened and curved melodic feture of the Beompae very well. Hahn Manyeong, who had studied on the Beompae, Budhhist chant, said that the Hotsori has five letters in a phrase, and there were 4 phrases in a song. And he had insisted that the form of the song, Hotsori, is ABAB. I analyze the melody of the Onghoge by the Hahn's method. I will extract the Wonjeom(a primary tone of a skeletal melodic structure) from the melody of Onghoge, and in the progress of the Wonjeom of Onghoge melodies, I will arrange the repeat of the Wonjeom melody. It is a structural melody of Onghoge. The first phrase of Bulmosan Yeongsanjae Onghoge, 'Pal bu geum gang ho do ryang(八部金剛護道場)' have 4 structural melodies, the second phrase 'Gong sin sog bu bo cheon wang(空神速赴報天王)', the third phrase 'Sam gye je cheon ham le jip(三界諸天咸來集)', the firth phrase 'Yeo geum bul chal bo jeong sang(如今佛刹補禎祥)' have 2 structural melodies each. The structural melodies of Onghoge are 10 in total. And the structural melody of the Onghoge is formed the shape of 'Mi - La - do - La - Mi'. All of the Onghoge melodies is repeated 10 times by the melodic shape. The form of the Onghoge is not ABAB by Hahn, but is 10 times repeat of the shape.