• Title/Summary/Keyword: 절연특성

Search Result 2,139, Processing Time 0.036 seconds

Validation of Structural Safety on Multi-layered Blade-type Vibration Isolator for Cryocooler under Launch Vibration Environment (적층형 블레이드가 적용된 냉각기용 진동절연기의 발사환경에서의 구조건전성 검증)

  • Jeon, Young-Hyeon;Ko, Dai-Ho;Jo, Mun-Shin;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.7
    • /
    • pp.575-582
    • /
    • 2018
  • The spaceborne cooler is applied to cool down of the focal plane of the infrared detector of the observation satellite. However, this cooler induces unnecessary micro-jitter which can degrade the image quality of the high-resolution observation satellite. In this study, we proposed a multi-layered blade type vibration isolator to attenuate micro-vibration generated from a spaceborne cooler, while assuring structural safety of the cooler under severe launch loads without an additional launch-lock device. The blade of the isolator is formed with multi-layers in order to obtain durability against fatigue failure and an adhesive is applied between each layers for granting high damping capability under launch vibration environment. In this study, the basic characteristics of the isolator were measured using the free-vibration test. The effectiveness of the isolator design was demonstrated by launch vibration test at qualification level.

Preparation and Properties of PVP (poly-4-vinylphenol) Gate Insulation Film For Organic Thin Film Transistor (유기박막 트랜지스터용 PVP (poly-4-vinylphenol) 게이트 절연막의 제작과 특성)

  • Baek, In-Jae;Yoo, Jae-Hyouk;Lim, Hun-Seung;Chang, Ho-Jung;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.359-363
    • /
    • 2005
  • The organic insulation devices with MIM (metal-insulator-metal) structures as PVP gate insulation films were prepared for the application of organic thin film transistors (OTFT). The co-polymer organic insulation films were synthesized by using PVP(poly-4-vinylphenol) as solute and PGMEA (propylene glycol monomethyl ether acetate) as solvent. The cross-linked PVP insulation films were also prepared by addition of poly (melamine-co-formaldehyde) as thermal hardener. The leakage current of the cross-linked PVP films was found to be about 300 pA with low current noise. and showed better property in electrical properties as compared with the co-polymer PVP insulation films. In addition, cross-linked PVP insulation films showed better surface morphology (roughness), showing about 0.11${\~}$0.18 nF in capacitance for all PVP film samples.

  • PDF

Assess of Breakdown Characteristics about Environmentally Friendly Gases (친환경절연재의 절연성 평가)

  • Choi, Eun-Hyeok;Koo, Bon-Ho;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.96-100
    • /
    • 2009
  • With the improvement of industrial society, the high quality electrical energy, simplification of operation and maintenance, ensuring reliability and safety are being required. This paper compares breakdown characteristics in $SF_6$ gas with $N_2/O_2$ Mixture gas($N_2:O_2=100$ : 0, 79 : 21, 60 : 40, 40 : 60) as using widely in High Voltage insulation equipment with the characteristics in different media which are focused on environmentally friendly gases. As an append result of research the results are fundamental data for electric insulation design of Distribution Power Facilities which will be studied and developed in the future. And we could make an environment friendly gas insulation material with mataining dielectric strength by $N_2/O_2$ Mixture gas which generates a lower lever of the global warming effect.

22.9kV 수, 변전설비에서의 감전 위험성 연구-절연커버 재질의 안전성 평가

  • 한운기
    • Electric Engineers Magazine
    • /
    • v.256 no.12
    • /
    • pp.24-30
    • /
    • 2003
  • 22.9KV 수, 변전설비의 노출충전부로부터 감전 재해를 예방하기 위하여 사용되는 절연커버 및 OC전선은 각각의 제조회사마다 상이한 절연재료를 사용하고 있다. 이러한 절연커버 및 OC 전선은 사용 여건상 한번 설치하면 소손 및 파괴가 일어날 때까지 사용하기 때문에 염해, 분진 등 이물질이 항시 존재하는 열악한 환경에 장기간 노출되더라도 내아크성, 내후성 및 내열성 등에 우수한 특성을 갖도록 설계될 필요성이 있다

  • PDF

Analysis on the over current characteristics of metal insulated HTS coil (금속 절연 초전도 코일의 과전류 특성 해석)

  • Cho, Jeonwook;Sim, Kideok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1110-1111
    • /
    • 2015
  • 초전도 코일의 안정성(stability)을 향상시키기 방법으로 초전도 자석의 턴(turn) 사이의 절연을 없애는 무절연 코일(no-insulation coil) 및 금속 테이프를 같이 권선하는 금속절연 코일(metal insulation coil)이 제안되어 활발히 연구되고 있다. 본 논문에서는 고온초전도 코일의 열적, 전기적 메카니즘을 분석하기 위한 FEM 모델을 제시하고, 이를 사용하여 �치 시 고온 초전도 코일의 안정성 향상 정도를 해석한다.

  • PDF

A Review on IPP/Elastomer/Nanofiller Composites for the Possibility of Use as Power Cable Insulations (동일배열 폴리프로필렌/엘라스토머/나노충전제 복합체의 전력케이블 절연체로서의 사용 가능성에 대한 문헌적 고찰)

  • Pyun, Sun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.184-192
    • /
    • 2012
  • For use as recyclable power cable insulations without dielectric oil, technology trends of IPP based thermoplastic polyolefin elastomer(TPO) nanocomposites were reviewed. In 2010 research results of IPP nanocomposite dielectrics for power capacitors showed promising high voltage properties except dielectric loss. Research of IPP based TPO nanocomposites for automotive exterior parts revealed considerable improvements of mechanical properties including impact strength, especially minimization of compatibilizer content, the origin of dielectric loss. A study on electrical properties of IPP based TPO nanocomposites containing a few weight percent of nanofillers for power cable insulations is suggested.

Study of passivation layers for the indium antimonide photodetector

  • Lee, Jae-Yeol;Kim, Jeong-Seop;Yang, Chang-Jae;Yun, Ui-Jun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.28.2-28.2
    • /
    • 2009
  • 군사적, 산업적 용도로 널리 활용되고 있는 적외선 검출기는 InSb, HgCdTe(MCT)와 같은 물질들을 감지 소자로 사용하고 있다. 현재 가장 많이 사용되는 MCT는 적외선의 전 영역을 감지할 수 있는 장점이 있지만, 대면적 제작이 어려운 단점이 있다. 이에 비해 InSb는 안정적인 재료의 특성, 높은 전하이동도($1.2\times10^6\;cm^2/Vs$) 그리고 대면적 소자 제작의 가능성 등이 높게 평가되어 차세대 적외선 검출소자로 각광 받고 있다. InSb 적외선 수광 소자는 1970년대부터 미국을 중심으로 이온주입, MOCVD 또는 MBE와 같은 다양한 공정을 이용하여 제작되어 왔으며, 앞으로도 군수용 제품을 비롯하여 산업전반에서 더욱 각광을 받을 것으로 예상된다. 하지만 InSb는 77 K에서 0.225 eV의 상대적으로 작은 밴드갭을 갖고 있기 때문에 누설전류로 인한 성능저하가 고질적인 문제로 대두되었고, 이를 해결하기 위한 고품질 절연막 연구가 InSb 적외선 수광 소자 연구의 주요 이슈 중 하나가 되어왔다. PECVD, photo-CVD, anodic oxidation 등의 공정을 이용하여 $SiO_2$, $Si_3N_4$, 양극산화막(anodic oxide) 등 다양한 물질들에 대한 연구가 진행되었고[1,2], 산화막과 반도체 계면에서의 열확산을 억제하여 계면트랩밀도를 최소화하기 위한 연구도 활발히 이루어졌다[3]. 하지만 InSb 소자의 성능개선을 위한 최적화된 산화막에 대한 연구는 여전히 불충분한 실정이다. 본 연구에서는 n형 (100) InSb 기판 (n = 0.2 ~ $0.85\times10^{15}cm^{-3}$ @ 77 K)을 이용하여 양극산화막, $SiO_2$, $Si_3N_4$ 등을 증착하고 절연막으로서 이들의 특성을 비교 분석하였다. 양극산화막은 상온에서 1 N KOH 용액을 이용하여 양극산화법으로 증착하였으며, $SiO_2$, $Si_3N_4$는 PECVD로 $150^{\circ}C$에서 $300^{\circ}C$까지 온도를 변화시켜가며 증착하였다. SEM분석과 XPS분석으로 두께의 균일도와 절연막의 조성, 계면확산 정도를 확인하였으며, I-V와 C-V 커브측정을 통해 각 절연막의 전기적 특성을 평가하였다. 이 분석들을 통해 각각의 공정 조건에 따른 절연막의 상태를 전기적 특성과 관련지어 설명할 수 있었다.

  • PDF

An investigation on the insulation characteristics of $SF_6$ mixtures gas under uniform and non-uniform electric field (평등/불평등 전계에서의 $SF_6$혼합된 가스의 절연파괴특성 연구)

  • Lee, Sang-Hwa;Lee, Young-Jo;Ahn, Hee-Sung;Jeong, Seung-Young;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1397-1398
    • /
    • 2007
  • 본 연구는 $SF_6$와 Dry-air(건조공기), $N_2$, $CO_2$ 가스가 혼합된 절연매체의 절연 특성과 부분방전 특성 연구를 기초실험용 쳄버와 70kV급 GIS mock up을 이용하여 교류전압을 인가하여 실험이 수행되었다. 전자의 경우, Sphere gap 및 Needle/Plate 전극시스템을 이용하여 순수 $SF_6$가스와 Dry-air, $N_2$, $CO_2$ 가스들의 절연내력을 비교하고, 챔버의 압력을 5기압으로 유지한 상태에서 Dry-air, $N_2$, $CO_2$$SF_6$가스의 혼합비를 변화시키면서 절연내력이 측정되었다. 후자의 경우, 기초실험에서 도출된 $SF_6$가스와 Dry-air, $N_2$, $CO_2$의 최적의 혼합비율을 선택한 후, 방전 개시전압과 부분방전 양상을 순수 $SF_6$가스의 결과와 비교분석하기 위한 실험을 수행하였다. 이를 위하여 GIS 사고의 주요원인이 되는 결함들, 즉 Protrusion, Floating, Free moving particle 들을 인위적으로 모의하여 Mock up 내부에 설치하고 내부 압력을 5기압으로 유지한 상태에서 수행되었다. 전자의 경우, $0.5{\sim}5$ 기압 범위 내에서 Dry-air, $N_2$, $CO_2$ 압력을 변화시켰을 때 절연내력은 전극시스템에 무관하게 순수 $SF_6$가스의 결과치의 Dir-air $47{\sim}51%$, $N_2\;48{\sim}61%$, $CO_2\;47{\sim}60%$ 정도이다. 또한 챔버 압력이 5기압인 상태에서 Dry-air, $N_2$, $CO_2$가 80% 혼합된 절연매체는 순수 $SF_6$가스 절연내력의 80%이상의 절연내력을 가지고 있다. 후자의 경우, 인가전압을 고정 시켰을 때, 부분방전 패턴과 방전크기는, 순수 $SF_6$가스와 Dry-air 가 80% 혼합된 절연매체는 동일한 패턴과 방전크기를 나타내고 있다. 이러한 결과를 근거로, 가스 압력이 5기압에서 운전되는 전력기기의 절연매체로서 혼합가스를 사용할 경우, $SF_6$가스와 Dry-air, $CO_2$, $N_2$ 가스들의 혼합비는 2:8정도가 적절한 것으로 제안한다.

  • PDF

저온 증착된 게이트 절연막의 안정성 향상을 위한 플라즈마 처리

  • Choe, U-Jin;Jang, Gyeong-Su;Baek, Gyeong-Hyeon;An, Si-Hyeon;Park, Cheol-Min;Jo, Jae-Hyeon;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.342-342
    • /
    • 2011
  • 산화막은 반도체 공정 중 가장 핵심적이며 기본적인 물질이다. 반도체 소자에서 내부의 캐리어들의 이동을 막고 전기를 절연시켜주는 절연체로서 역할을 하게 된다. 실제로 제작된 산화막에서는 dangling bond 혹은 내부에 축적되는 charge들의 의해 leakage가 생기게 되고 그에 따라 산화막의 특성은 저하되게 된다. 내부에서 특성을 저하시키는 defect을 감소시키기 위해 Plasma Treatment에 따른 특성변화를 관찰하였다. 본 연구에서는 최적화 시킨 Flexible TFT제작을 위해 저온에서 Silicon Oxide로 형성한 Gate Insulator에 각각 N2O, H2, NH3가스를 주입 후 Plasma처리를 하였다. 특성화 시킨 Gate Insulator를 이용하여 MIS(Metal-Insulator-Semiconductor)구조를 제작 후 C-V curve특성변화, Dit의 감소, Stress bias에 따른 stability를 확인 하였다.

  • PDF

Amorphous Indium Gallium Zinc Oxide를 활성층으로 사용한 MIS소자에서의 Bulk와 Interface에서의 Traps 분석

  • Kim, Tae-Uk;Gu, Jong-Hyeon;No, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.95-95
    • /
    • 2011
  • 비정질 산화물 반도체(Amorphous oxide semiconductors: AOSs)는 대면적화에도 불구하고 높은 이동도를 가지고, 상온에서도 제작할 수 있고, 투명 플렉시블 디스플레이 소자에 사용할 수 있기 때문에 최근 들어 각광받고 있는 연구 분야이다. 본 연구에서는 스퍼터링을 이용하여 활성층을 Amorphous indium gallium zinc oxide(a-IGZO)로 증착할 시에 스퍼터의 파워와 챔버내의 Ar/O2 비율을 다르게 했을 때 소자에 미치는 영향을 MIS구조를 이용하여 분석했다. 또한 같은 조건의 a-IGZO 활성층을 사용한 박막트랜지스터(TFT) 소자의 절연막의 종류를 바꿔가며 제작했을때의 소자의 특성 변화에 대해서도 분석하였다. 먼저 60 nm 두께의 a-IGZO층을 Heavily doped된 N형 실리콘 기판위에 스퍼터링 파워와 가스 분압비를 달리하여 증착하였다. 그 후 30 nm두께의 SiO2, Al2O3, SiNx 절연막을 증착하고, 마지막으로 열 증발 증착장비(Thermal Evaporator)를 이용하여 Al 전극을 150nm 증착하였다. 소자의 전기적 특성 분석은 HP4145와 Boonton 720을 사용하여 I-V와 C-V를 측정하였다. 위의 실험으로부터 스퍼터에서의 증착 rf파워가 증가할수록 a-IGZO 박막 트랜지스터에서의 캐리어 이동도가 감소하는 것을 볼 수 있었고, 챔버내의 가스분압비와 소자의 절연막의 종류가 변하면 a-IGZO 박막 트랜지스터의 전기적 특성이 변하는 것을 볼 수 있었다. 이러한 캐리어 이동도의 감소와 전기적 특성의 변화의 이유는 a-IGZO 활성층의 bulk trap과 절연막, 활성층 사이의 interface trap에 의한 것으로 보여진다.

  • PDF