• 제목/요약/키워드: 절연지

검색결과 881건 처리시간 0.027초

SF_6 가스와 절연지의 절연계에서 가스압력에 따른 부분방전현상 (Partial Discharge Phenomenon with $SF_6$ Gas Pressures in Insulation consisting of Insulation Paper and $SF_6$ Gas)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.65-71
    • /
    • 2001
  • This paper describes partial discharge phenomenon with SF6gas pressures in insulation consisting of insulation paper and SF6 gas. We made the specimens with SF6 gas gaps which exist between aramid papers and electrodes and calculated the electric field intensity in the these gaps. We measured the partial discharge inception voltages and the AC breakdown voltages with the test method of IEC 60060-2 and did the partial discharge degradation experiments with a constant voltage. According to gas pressures, the breakdown voltages in SF6gas gaps were calculated by Paschen's law. And these results showed the ability applying partial discharge inception voltages evaluation to Paschen's law and the relationship between the PD quantities occurring insulation breakdown and PD occurring area.

  • PDF

$SF_6$ EHV VT 권선 절연지의 절연특성 (Insulation Characteristics of PET Films for $SF_6$ EHV VT Winding)

  • 김정달;박재윤;정장근;김종석;하현진;이용길
    • 한국전기전자재료학회논문지
    • /
    • 제14권5호
    • /
    • pp.391-396
    • /
    • 2001
  • The purpose of this study is to investigate the effect of hole or crack on the Insulation characteristics of a PET films for EHV(Extra High Voltage) VT winding. The hole or the crack in the PET films was made and the insulation characteristics of them were measured. Ad an experimental result, it was shown hat he PDIV(Partial Discharge Inception Voltage) and the BDV(Breakdown Voltage) of the PET films with hole or crack were lower than those without them, and were markedly dependent on their position and temperature. Therefore, the hole and the crack affected to insulation characteristics of PET films for SF$_{6}$EHV(Extra High Voltage) VT Winding.g.

  • PDF

초고압발생 및 측정

  • 조연옥
    • 전기의세계
    • /
    • 제37권7호
    • /
    • pp.4-11
    • /
    • 1988
  • 본고에서는 초고압기술 중 전기응력에 대해서 주로 논하고자 한다. 절연체의 전기강도는 여러가지의 환경적인 요소들에 따라서 크게 영향을 받으므로 절연체의 전기강도를 수량적으로 정의하기 위해서는 요소들의 영향을 충분히 알아야 할 것이다. 이들 요소 중 전기응력에 관련된 것들은 전압의 크기 및 파형이므로 초고압계통에서 사용되는 절연체가 그 초고압ㅇ 잘 견딜 수 있는 지를 알기 위해서는 그 초고압계통에서 일어날 수 있는 지를 확인해야 할 것이다. 그러므로 전기응력에 관한 한 초고압에서 중요한 문제는, 초고압계통에서 일어날 수 있는 파형을 해석하고, 그 파형을 어떻게 실험실에서 모의 하여 발생하고, 발생된 전압을 정확하게 측정하는 기술이라 하겠다. 이러한 관점에서 본고에서는 현재 전력계통 분야의 세계각국의 초고압연구를 간략하게 소개한 후 초고압 발생 및 측정에 대해서 논하고자 한다.

  • PDF

Zig-Zag 귄선에 의한 내철형 주상변압기 개발에 관한 연구 (A study on the Development of the Shell-type Pole Transformer Using the Zig-Zag Winding)

  • 민윤홍;신대철
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.121-128
    • /
    • 2007
  • 본 논문에서는 세계최초로 내철형 주상변압기 코일의 권선을 일반적인 권선방법에서 Zig-Zag(가칭) 권선방법으로 설계 제작하는 방법을 제안하였으며, 또한 바니시 함침공정을 생략하고 단락강도 및 절연내력을 향상시킬 수 있는 내철형 변압기용 권선의 신프레임 구조개발 내용을 제안하였다. 기존의 주상변압기 권선방법에 비하여 전기절연 측면에서 층간 절연지의 사용매수 및 두께를 획기적으로 절감할 수 있는 장점이 있다. 또한 원가절감과 손실저감 및 단락기계력 대처능력이 우수함을 검증하였으며 국내전력회사 배전계통 주상변압기에 유용하게 활용할 수 있다.

지상변압기 방열 개선을 통한 수명연장에 관한 연구 (A study on the life prolongation of pad mounted transformer through the improvement of heat radiation)

  • 천성남;박철배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.503-503
    • /
    • 2007
  • 본 논문에서는 지중배전(22.9kV) 선로에 사용되는 지상변압기를 대상으로 수행한 방열해석 및 개선과 변압기수명연장에 관한 검토 결과를 수록하였다. 변압기의 열화메커니즘에 대한 문헌 조사를 통해 변압기 온도와 수명간의 관계를 작도하였는바, 수명 평가를 위한 핵심 인자로 열에 의한 절연지의 열화에 초점을 맞추었다. 기존 외함에 설치된 방열구중 상부 위치를 상부판에도 변경하는 경우 약25%의 통풍량 증가 효과를 기대할 수 있을 것으로 평가 되었으며 상부판과 내함 사이에 형성되던 고온 영역에서의 온도를 약$15^{\circ}C$정도 낮출 수 있는 것으로 나타났다. 절연지의 인장강도 변화로 평가한 수명예측 곡선에 따르면 약$10^{\circ}C$의 은도 저감은 약10배의 수명 연장 효과를 가져오는 것으로 나타난바, 본 연구에서 확인한 방열구의 위치 변경에 따른 지상기기 내부의 온도 저하는 변압기 수명을 연장하는데 일조할 것으로 기대된다. 기존 지상변압기에서의 방열구조를 통해 변압기 온도와 수명간의 관계를 작도하였는바, 수명 평가를 위한 핵심인자로 효과적으로 방열할 수 있는 새로운 외함의 구조 및 디자인을 제시하고 시뮬레이션을 통해 개선효과를 예측하였다. 또한, 개선된 모델을 가지고 실제 변압기를 제작한 후 부하를 인가하여 개선전과 후에 대한 방열효과를 실증시험을 통해 확인하였다.

  • PDF

UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정 (Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제35권3호
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

N2-O2 혼합가스에 따른 Teflon의 절연파괴특성 (Breakdown Characteristics of Teflon by N2-O2 Mixture gas)

  • 최은혁;최병숙;박숭규
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.69-74
    • /
    • 2018
  • 산업사회의 발달과 더불어 신뢰성 높은 양질의 전기에너지와 운전 및 보수의 간편화, 계통 운용의 신뢰성, 안전성 확보가 요구되고 있다. 본 논문에서는 각종 전력설비에서 SF6을 대체하여 사용되고 있는 친환경절연제 $N_2-O_2$ 혼합가스 고체 절연물의 절연파괴특성과 고체절연재로 사용되고 있는 테프론의 연면절연특성을 압력에 따른 특성을 확인하였다. 대기와 비슷한 성분비 일 때 상대적으로 절연파괴특성이 테프론의 연면절연특성이 안정화되며, Paschen 법칙에 의해 평등전계에 가까운 전극중의 기체의 절연파괴전압은 압력에 비례하여 높아지고 있음을 실험을 통하여 확인하였다. 연면절연파괴전압은 압력에 따라 선형적으로 증가하였으며, 혼합가스의 $O_2$ 가스 혼합비에 따라 절연파괴전압의 차이가 발생하였다. 이는 $O_2$ 가스의 전기적 부성기체의 영향과 분자 간 충돌거리에 의해 연면절연파괴전압이 달라졌고, 본 연구에서 분자 간 충돌거리의 영향이 더 크게 작용하였다. 연면절연특성에 따른 테프론에 적용 가능한 절연파괴전압 관계식을 산출하였다. 이러한 결과는 전력설비의 절연설계 시 기초자료로 사용될 수 있을 것이라 생각된다.

IV 및 HIV 절연전선의 가속열화에 따른 절연피복의 성능변화에 관한 연구 (A Study on the Performance Change of Insulation Sheath Due to Accelerated Degradation of IV and HIV Insulated Wire)

  • 최수길;김시국
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.114-123
    • /
    • 2019
  • 본 논문은 IV 및 HIV 절연전선의 가속열화에 따른 절연피복의 성능변화에 관한 연구이다. IV 및 HIV 절연전선의 절연열화를 가정하기 위해 가속수명시험 모형 중 아레니우스 방정식을 이용한 가속수명시험을 진행하였고, 등가수명 0년, 10년, 20년, 30년, 40년 실험시료를 제작하였다. IV 및 HIV 절연전선의 가속열화가 진행됨에 따라 최대인장하중은 커지는 반면, 절연전선의 신장률, 파단시간, 유연성이 점차 감소되는 것으로 나타났다. 추가적인 주사전자현미경을 이용한 등가수명별 절연전선 표면 분석 결과 가속열화가 진행됨에 따라 시료 표면에 결정형 구조 및 천공 등의 현상이 발생되어 노후화에 따른 절연열화가 진행 될수록 절연체의 기계적 특성이 감소되는 것으로 나타났다. 따라서 절연성능 저하에 따른 전기화재 위험성을 사전에 예방하기 위해선 건축물 내에 설치되는 절연체의 성능저하를 고려한 제도적인 절연전선의 교체 및 보수시기의 마련이 필요할 것으로 생각된다.

고온 초전도 케이블 절연을 위한 절연지의 인장응력 및 절연파괴 특성 (The Characteristics of Electrical Breakdown and Tensile Stress of Dielectric Paper for Insulation of HTS Cable)

  • 김영석;곽동순;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.61-64
    • /
    • 2003
  • The degradation of the dielectric properties of insulating papers that were used under loaded conditions at cryogenic temperature was paid attention. Electrical and tensile stress properties of dielectric paper at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased.

  • PDF

회복전압 측정을 위한 DAQ 프로그램 (A Data Aquisition program for recovery voltage measurement)

  • 이세현;최태식;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.31-34
    • /
    • 2007
  • 회복전압 측정법(RVM: Recovery voltage measurement)은 최근 유럽지역에서 활발히 연구 진행되고 있는 절연 진단 기법 중의 하나로 소개된바 있으며, 오일과 절연지 사이에 스며든 수분량을 검출할 수 있는 진단 시스템기법이다. 변압기 내부의 절연물질에 대한 분극특성을 분석함으로서 열화진행정도 및 열화정도를 진단하는데 활용될 수 있다. 본 논문은 국산화의 일환으로 전기계측제어용 LabVIEW 프로그램을 활용하여 RVM 전 과정을 자동으로 사용할 수 있도록 자체 제작한 프로그램을 소개하고자 한다.

  • PDF