• Title/Summary/Keyword: 절대적 위치

Search Result 310, Processing Time 0.027 seconds

Analysis on Social Area of Taegu (대구시의 사회지역분석)

  • Choi, Seok-Joo
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.2
    • /
    • pp.209-225
    • /
    • 1997
  • Today, rapid progress of urbanization is discovered commonly in many countries, especially in developing countries, which has led to spatial order and development process of city. Historically, Taegu was a walled city and formed mono-nucleus which was restricted by the castle. As the city grew gradually, the castle was removed as a result of diversification in traffic network, change of socio-economic environment, formation of industrial base and functional distribution. According to reconstruction maps of residential patterns, there was distinctive residential segregation among ethnic groups. Koreans in Taegu in 1939, aggregated densely in the southern and western parts of the city. The Japanese were concentrated densely in the northern and eastern parts of Taegu. And the street pattern within residential areas of the Korean people was shaped like a maze type in contrast with Japanese residential areas, which showed grid pattern of streets. This is another general pattern of almost all colonial cities, especially in Asia. Through this process, today it appears that, out of overall residential areas which occupy the highest ratio in urban land use, those for eminent people influence the functional development of urban spatial structure very heavily as a key point in urban residetial structure. Truly, residential segregation can be seen as the spatial manifestation of uneven distribution of such important scarce resources as housing and residential environment. In this study, the characteristics of locational distribution of the eminent people show their socially and economically stabilized standing in Taegu, taking the aforesaid situation as a background of the study. And the process of this study is as follows ; to examine the forming process of residential areas in the city as a theoretical supporting, to put in order on classical interpretation to formation of residential areas, and general type modern residential areas formation, and economic decision factor of land use. Therefore, this study aims to examine growth and development of eminent persons' residential areas and, at the same time, extract locational characteristics through the pattern of eminent persons' location and predict changes in the future.

  • PDF

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

UBVI CCD Photometry of NGC 7790 (NGC 7790의 UBVI CCD 측광)

  • Choi, Dong Yeol;Kim, Hee Soo;Lim, Beomdu;Sung, Hwankyung
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.661-673
    • /
    • 2015
  • UBVI CCD photometry of the intermediate age open cluster NGC 7790 has been obtained using AZT-22 1.5 m telescope (f/7.74) at the Maidanak Astronomical Observatory in Uzbekistan. NGC 7790 contains three ${\delta}$ Cep variable stars including CEa Cas, CEb Cas, and CF Cas. PSF photometry was carried out using IRAF/DAOPHOT for all observations. The total number of stars observed both in V and I filter was 1008 and the limiting magnitude was $V{\approx}22$. To determine atmospheric extinction coefficients and photometric zero points, many blue and red standard stars as well as the standard stars in the celestial equator under various airmass were observed. Photometric data were transformed into the standard Johnson-Cousins' UBVI standard system. From the analysis of UBVI color-magnitude diagram and color-color diagram, the color excess in V and I filter [$E(B-V)=0.58{\pm}0.02$], the selective extinction ratio in V and I filter [$R_V{\equiv}A_V/E(B-V)=3.02{\pm}0.09$] and distance modulus ($V_0-M_V=12.65{\pm}0.10$) of the cluster were determined. The age of the cluster was estimated to be log $age=8.05{\pm}0.05$ [yr] based on the position of these three Cepheid variables in the color-magnitude diagram, the isochrone of the Geneva group ($Ekstr{\ddot{o}}m$ et al., 2012-Z=0.019), and the isochrone of the Padova group (Bressan et al., 2012-Z=0.014) were used to compare each other. Of them, the Geneva models that considered stellar rotation well described the position of ${\delta}$ Cepheid variables in the blue loop. Although they were well consistent with standard period-luminosity relation of ${\delta}$ Cepheid variables, three Cepheid variables in NGC 7790 were, on average, brighter by about 0.5 mag than the absolute magnitude estimated from the mean period-luminosity relation at a given period.

The Proprioceptive Function of Rotator Cuff Tear Patients: Preliminary Report of Pre-operative Function (회전근개 파열 환자의 고유 수용성 감각 기능: 수술전 기능의 예비 보고)

  • Lee, Hyunil;Heo, Jaewon;Yoo, Jae Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • Purpose: Proprioceptive function has been known to be important to shoulder stability. However, the function in rotator cuff tear patients is rarely investigated. The purpose of current study is to report the proprioceptive function in rotator cuff tear patients and to analyze the proprioceptive function regarding the tear size and the presence of subscapularis tear. Materials and Methods: Between 2011 and 2012, total 76 patients (male 28 and female 48) were recruited and average age was 61.7 years old (range, 38~76). Preoperatively, joint position senses in internal and external rotation were measured for proprioceptive function testing by method of active re-positioning technique. The absolute difference from set point was measured. Proprioceptive function was further analyzed according to tear size of rotator cuff, the presence of subscapularis tear, visual analogue scale of pain, shoulder functional score (American society of elbow and shoulder score), and ranges of motion in shoulder. Results: The absolute difference for external rotation was $4.9^{\circ}{\pm}2.9^{\circ}$, in normal joint and $4.9^{\circ}{\pm}3.0^{\circ}$for involved joint in rotator cuff tear patients. This difference was not significant statistically (p=0.87). The absolute difference for internal rotation was $4.0^{\circ}{\pm}2.7^{\circ}$in normal joint whereas $4.8^{\circ}{\pm}3.7^{\circ}$ for involved joint showing statistically significant difference (p=0.043). There was some trend that the proprioceptive function of internal rotation was more impaired in the bigger tear size group (more than medium tear) compared to the smaller tear size group (partial thickness and small tear, 5.0 vs. 4.0, p=0.061). The impairment of internal rotation proprioception was also accentuated in patients with subscapularis tear (4.8 vs. 4.0, p=0.065). The proprioceptive function of internal rotation was decreased when the pain visual analogue scale was increased (5.2 vs. 4.0 p=0.04), shoulder functional score was decreased (6.1 vs. 4.2, p=0.005), or range of motion in shoulder joint was restricted (5.3 vs. 3.7, p=0.041). Conclusion: The deficit of proprioceptive function was observed in rotator cuff tear patients. Proprioception for internal rotation was impaired in patients with the bigger tear size and subscapularis tear. Pain, shoulder function score, and range of motion were also shown to be related with the deficit in proprioceptive function.

  • PDF

Very short-term rainfall prediction based on radar image learning using deep neural network (심층신경망을 이용한 레이더 영상 학습 기반 초단시간 강우예측)

  • Yoon, Seongsim;Park, Heeseong;Shin, Hongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1159-1172
    • /
    • 2020
  • This study applied deep convolution neural network based on U-Net and SegNet using long period weather radar data to very short-term rainfall prediction. And the results were compared and evaluated with the translation model. For training and validation of deep neural network, Mt. Gwanak and Mt. Gwangdeoksan radar data were collected from 2010 to 2016 and converted to a gray-scale image file in an HDF5 format with a 1km spatial resolution. The deep neural network model was trained to predict precipitation after 10 minutes by using the four consecutive radar image data, and the recursive method of repeating forecasts was applied to carry out lead time 60 minutes with the pretrained deep neural network model. To evaluate the performance of deep neural network prediction model, 24 rain cases in 2017 were forecast for rainfall up to 60 minutes in advance. As a result of evaluating the predicted performance by calculating the mean absolute error (MAE) and critical success index (CSI) at the threshold of 0.1, 1, and 5 mm/hr, the deep neural network model showed better performance in the case of rainfall threshold of 0.1, 1 mm/hr in terms of MAE, and showed better performance than the translation model for lead time 50 minutes in terms of CSI. In particular, although the deep neural network prediction model performed generally better than the translation model for weak rainfall of 5 mm/hr or less, the deep neural network prediction model had limitations in predicting distinct precipitation characteristics of high intensity as a result of the evaluation of threshold of 5 mm/hr. The longer lead time, the spatial smoothness increase with lead time thereby reducing the accuracy of rainfall prediction The translation model turned out to be superior in predicting the exceedance of higher intensity thresholds (> 5 mm/hr) because it preserves distinct precipitation characteristics, but the rainfall position tends to shift incorrectly. This study are expected to be helpful for the improvement of radar rainfall prediction model using deep neural networks in the future. In addition, the massive weather radar data established in this study will be provided through open repositories for future use in subsequent studies.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

A model for enhancing the academic excellence of adult college students (성인대학생의 학업수월성 강화를 위한 모형)

  • Kim, Eun Young;Kim, Jin Sook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.2
    • /
    • pp.195-200
    • /
    • 2019
  • The purpose of this study is to present a model for enhancing the academic excellence of adult college students. For this purpose, 408 adult college students attending 2-year and 4-year colleges in Busan, Daegu, and Gyeongbuk were surveyed and analyzed. The components of the model are curriculum, educational methods, evaluation of education, educational administration, educational environment, and institutional support and the results are as follows. First, the curriculum preferred by adult college students was to acquire diverse academic knowledge for a degree, to acquire knowledge and skills to develop skills for the workplace, and to acquire new information and knowledge regarding issues in society as a whole. Second, the professors' qualification among the educational methods preferred by adult college students was professional competence of the professors based on their theoretical and practical skills. The preferred teaching methods were lecture, discussion, action learning, and the project learning method in that order and video and PowerPoint were preferred as effective teaching mediums. Third, the preferred course for adult college students is operated on weekends, and three years was preferred to get a bachelor's degree. The possible hours of learning per day is 3~6 hours, indicating the necessity of e-learning, B-learning, and prior learning experience recognition systems. Fourth, the education evaluation method preferred by adult college students was a compromise method which is a mixture of absolute evaluation and relative evaluation, and it also showed the need for Pass or Non Pass evaluation method. Fifth, the internal factors of college selection preferred by adult college students were the acquisition of new knowledge and skills, and the external factors were desire to receive many opportunities related to employment and job improvement. The classroom, which provides an effective environment, was a fixed seat classroom and an indoor classroom environment was emphasized for desired educational environment. Sixth, institutional support preferred by adult college students was computer-related programs and learning club support services.

Temporal Variations of Ore Mineralogy and Sulfur Isotope Data from the Boguk Cobalt Mine, Korea: Implication for Genesis and Geochemistry of Co-bearing Hydrothermal System (보국 코발트 광상의 산출 광물종 및 황동위원소 조성의 시간적 변화: 함코발트 열수계의 성인과 지화학적 특성 고찰)

  • Yun, Seong-Taek;Youm, Seung-Jun
    • Economic and Environmental Geology
    • /
    • v.30 no.4
    • /
    • pp.289-301
    • /
    • 1997
  • The Boguk cobalt mine is located within the Cretaceous Gyeongsang Sedimentary Basin. Major ore minerals including cobalt-bearing minerals (loellingite, cobaltite, and glaucodot) and Co-bearing arsenopyrite occur together with base-metal sulfides (pyrrhotite, chalcopyrite, pyrite, sphalerite, etc.) and minor amounts of oxides (magnetite and hematite) within fracture-filling $quartz{\pm}actinolite{\pm}carbonate$ veins. These veins are developed within an epicrustal micrographic granite stock which intrudes the Konchonri Formation (mainly of shale). Radiometric date of the granite (85.98 Ma) indicates a Late Cretaceous age for granite emplacement and associated cobalt mineralization. The vein mineralogy is relatively complex and changes with time: cobalt-bearing minerals with actinolite, carbonates, and quartz gangues (stages I and II) ${\rightarrow}$ base-metal sulfides, gold, and Fe oxides with quartz gangues (stage III) ${\rightarrow}$ barren carbonates (stages IV and V). The common occurrence of high-temperature minerals (cobalt-bearing minerals, molybdenite and actinolite) with low-temperature minerals (base-metal sulfides, gold and carbonates) in veins indicates a xenothermal condition of the hydrothermal mineralization. High enrichment of Co in the granite (avg. 50.90 ppm) indicates the magmatic hydrothermal derivation of cobalt from this cooling granite stock, whereas higher amounts of Cu and Zn in the Konchonri Formation shale suggest their derivations largely from shale. The decrease in temperature of hydrothermal fluids with a concomitant increase in fugacity of oxygen with time (for cobalt deposition in stages I and II, $T=560^{\circ}C-390^{\circ}C$ and log $fO_2=$ >-32.7 to -30.7 atm at $350^{\circ}C$; for base-metal sulfide deposition in stage III, $T=380^{\circ}-345^{\circ}C$ and log $fO_2={\geq}-30.7$ atm at $350^{\circ}C$) indicates a transition of the hydrothermal system from a magmatic-water domination toward a less-evolved meteoric-water domination. Sulfur isotope data of stage II sulfide minerals evidence that early, Co-bearing hydrothermal fluids derived originally from an igneous source with a ${\delta}^{34}S_{{\Sigma}S}$ value near 3 to 5‰. The remarkable increase in ${\delta}^{34}S_{H2S}$ values of hydrothermal fluids with time from cobalt deposition in stage II (3-5‰) to base-metal sulfide deposition in stage III (up to about 20‰) also indicates the change of the hydrothermal system toward the meteoric water domination, which resulted in the leaching-out and concentration of isotopically heavier sulfur (sedimentary sulfates), base metals (Cu, Zn, etc.) and gold from surrounding sedimentary rocks during the huge, meteoric water circulation. We suggest that without the formation of the later, meteoric water circulation extensively through surrounding sedimentary rocks the Boguk cobalt deposits would be simple veins only with actinolite + quartz + cobalt-bearing minerals. Furthermore, the formation of the meteoric water circulation after the culmination of a magmatic hydrothermal system resulted in the common occurrence of high-temperature minerals with later, lower-temperature minerals, resulting in a xenothermal feature of the mineralization.

  • PDF