• Title/Summary/Keyword: 절대교정

Search Result 55, Processing Time 0.025 seconds

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy (양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구)

  • Kim, Sunyoung;Choi, Jaehyock;Won, Huisu;Hong, Joowan;Cho, Jaehwan;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • In this study, the authors attempted to measure the skin dose by irradiating the actual dose on to the TLD(Thermo-Luminescence Dosimeter) and EBT3 Film used as the In-vivo dosimetry after planning the same treatment as the actual patient on a Phantom, because the erythema or dermatitis is frequently occurred on the patients' skin at the time of the proton therapy of medulloblastoma patient receiving the proton therapy. They intended to know whether there is the usefulness for the dosimetry of skin by the comparative analysis of the measured dose values with the treatment planned skin dose. The CT scan from the Brain to the Pelvis was done by placing a phantom on the CSI(Cranio-spinal irradiation) Set-up position of Medulloblastoma, and the treatment Isocenter point was aligned by using DIPS(Digital Image Positioning System) in the treatment room after planning a proton therapy. The treatment Isocenter point of 5 areas that the proton beam was entered into them, and Markers of 2 areas shown in the Phantom during CT scans, that is, in all 7 points, TLD and EBT3 Film pre-calibrated are alternatively attached, and the proton beam that the treatment was planned, was irradiated by 10 times, respectively. As a result of the comparative analysis of the average value calculated from the result values obtained by the repeated measurement of 10 times with the Skin Dose measured in the treatment planning system, the measured dose values of 6 points, except for one point that the accurate measurement was lacked due to the measurement position with a difficulty showed the distribution of the absolute dose value ${\pm}2%$ in both TLD and EBT Film. In conclusion, in this study, the clinical usefulness of the TLD and EBT3 Film for the Enterance skin dose measurement in the first proton therapy in Korea was confirmed.

The Role of Ref-1 in the Differentiation Process of Monocytic THP-1 Cells (단핵구세포주 THP-1의 분화과정에서 Ref-1의 역할)

  • Da Sol Kim;Kang Mi Kim;Koanhoi Kim;Young Chul Park
    • Journal of Life Science
    • /
    • v.34 no.4
    • /
    • pp.271-278
    • /
    • 2024
  • Redox factor (Ref)-1, a ubiquitously expressed protein, acts as a modulator of redox-sensitive tran- scription factors and as an endonuclease in the repair pathway of damaged DNA. However, the function of Ref-1 in the differentiation of monocytes into macrophages has not been defined. In this study, we investigated the effects of Ref-1 on the monocyte differentiation process using the human monocytic cell line THP-1. The differentiation agent PMA increased cell adhesion over time and showed a sig- nificant increase in phagocytic function but decreased the intracellular amount of Ref-1. Ref-1 inhibitor E3330 and Ref-1 knockdown using the siRNA technique reduced cell adhesion and the expression of differentiation markers, such as CD14, ICAM-1, and CD11b, by PMA stimulation. This means that the role of Ref-1 is absolutely necessary in the initial process of differentiating THP-1 cells stimulated by PMA. Next, the distribution of Ref-1 was examined in the cytoplasm and nucleus of THP-1 cells stimulated with PMA. Surprisingly, PMA stimulation resulted in the rapid translocation of Ref-1 to the nucleus. To prove that movement of Ref-1 to the nucleus is required for monocyte differentiation, a Ref-1 vector with the nuclear localization sequence (NLS) deleted was used. As a result, overexpression of ∆NLS Ref-1, which restricted movement to the nucleus, suppressed the expression of differentiation markers and notably reduced phagocytic function in PMA-stimulated THP-1 cells. In conclusion, these data suggest that the differentiation of monocytic THP-1 cells requires Ref-1 nuclear translocation during the initial process of biochemical events following stimulation from PMA.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.