• Title/Summary/Keyword: 전자 구조

Search Result 13,152, Processing Time 0.05 seconds

Immunocytochemistry of Metallothionein Expression in Developing Rat Liver (발생중인 흰쥐 간에서의 Metallothionein 발현에 관한 면역세포화학적 연구)

  • Oh, Seung-Han;Ahn, Young-Mo;Shin, Kil-Sang;Kim, Wan-Jong
    • Applied Microscopy
    • /
    • v.34 no.3
    • /
    • pp.171-178
    • /
    • 2004
  • Metallothionein (MT) is a family of ubiquitous, low molecular weight (6-7 kDa), cysteine-rich protein with a high affinity to metal ions and has no aromatic amino acids and histidine. Some of the known functions of MT include detoxification of heavy metals and alkylating agents and neutralization of free radicals. Also, this protein may affect a number of cellular processes including gene expression, apoptosis, proliferation and differentiation. But, its actual functions are still not clear. The present study was undertaken to examine immunocytochemically the localization of MT in developing rat liver. On the day 11 of gestation, the fetal rat liver has already been formed and contained numerous oval cells with high nuclear cytoplasmic ratio, which were the progenitors of hepatic parenchymal cells, but no reaction products of MT were detected at this time. And then, positive reactions against MT started to appear predominantly in the parenchymal cells of liver from the 13th day after gestation. Reaction products, immunogold particles or brown coloration, were localized at both the nucleus and the cytoplasm of the parenchymal cells, except mitochondria. The intensity of this reaction gradually increased, and exhibited the strongest at birth. The intensity of MT staining and immunogold labelling diminished with growth, and by the 15th day after birth weak positive reaction was observed in the cells. In brief, positive reactions for MT were observed in the oval cells and the parenchymal cells during fetal stage, meanwhile they were present only in the parenchymal cells after birth. The present results suggest that MT possibly involves parechymal cell proliferation and differentiation through the storage or the supply of various metal ions in the developing rat liver.

A Study on Activation Characteristics Generated by 9 MeV Electron Linear Accelerator for Container Security Inspection (컨테이너 보안 검색용 9 MeV 전자 선형가속기에서 발생한 방사화 특성평가에 관한 연구)

  • Lee, Chang-Ho;Kim, Jang-Oh;Lee, Yoon-Ji;Jeon, Chan-Hee;Lee, Ji-Eun;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.563-575
    • /
    • 2020
  • The purpose of this study is to evaluate the activation characteristics that occur in a linear accelerator for container security inspection. In the computer simulation design, first, the targets consisted of a tungsten (Z=74) single material target and a tungsten (Z=74) and copper (Z=29) composite target. Second, the fan beam collimator was composed of a single material of lead (Z=82) and a composite material of tungsten (Z-74) and lead (Z=82) depending on the material. Final, the concrete in the room where the linear accelerator was located contained magnetite type and impurities. In the research method, first, the optical neutron flux was calculated using the MCNP6 code as a F4 Tally for the linear accelerator and structure. Second, the photoneutron flux calculated from the MCNP6 code was applied to FISPACT-II to evaluate the activation product. Final, the decommissioning evaluation was conducted through the specific activity of the activation product. As a result, first, it was the most common in photoneutron targets, followed by a collimator and a concrete 10 cm deep. Second, activation products were produced as by-products of W-181 in tungsten targets and collimator, and Co-60, Ni-63, Cs-134, Eu-152, Eu-154 nuclides in impurity-containing concrete. Final, it was found that the tungsten target satisfies the permissible concentration for self-disposal after 90 days upon decommissioning. These results could be confirmed that the photoneutron yield and degree of activation at 9 MeV energy were insignificant. However, it is thought that W-181 generated from the tungsten target and collimator of the linear accelerator may affect the exposure when disassembled for repair. Therefore, this study presents basic data on the management of activated parts of a linear accelerator for container security inspection. In addition, When decommissioning the linear accelerator for container security inspection, it is expected that it can be used to prove the standard that permissible concentration of self-disposal.

Development of Neural Network Based Cycle Length Design Model Minimizing Delay for Traffic Responsive Control (실시간 신호제어를 위한 신경망 적용 지체최소화 주기길이 설계모형 개발)

  • Lee, Jung-Youn;Kim, Jin-Tae;Chang, Myung-Soon
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.3 s.74
    • /
    • pp.145-157
    • /
    • 2004
  • The cycle length design model of the Korean traffic responsive signal control systems is devised to vary a cycle length as a response to changes in traffic demand in real time by utilizing parameters specified by a system operator and such field information as degrees of saturation of through phases. Since no explicit guideline is provided to a system operator, the system tends to include ambiguity in terms of the system optimization. In addition, the cycle lengths produced by the existing model have yet been verified if they are comparable to the ones minimizing delay. This paper presents the studies conducted (1) to find shortcomings embedded in the existing model by comparing the cycle lengths produced by the model against the ones minimizing delay and (2) to propose a new direction to design a cycle length minimizing delay and excluding such operator oriented parameters. It was found from the study that the cycle lengths from the existing model fail to minimize delay and promote intersection operational conditions to be unsatisfied when traffic volume is low, due to the feature of the changed target operational volume-to-capacity ratio embedded in the model. The 64 different neural network based cycle length design models were developed based on simulation data surrogating field data. The CORSIM optimal cycle lengths minimizing delay were found through the COST software developed for the study. COST searches for the CORSIM optimal cycle length minimizing delay with a heuristic searching method, a hybrid genetic algorithm. Among 64 models, the best one producing cycle lengths close enough to the optimal was selected through statistical tests. It was found from the verification test that the best model designs a cycle length as similar pattern to the ones minimizing delay. The cycle lengths from the proposed model are comparable to the ones from TRANSYT-7F.

Enzymatic Hydrolysis of Rice Straw, a Lignocellulosic Biomass, by Extracellular Enzymes from Fomitopsis palustris (Fomitopsis palustris의 균체 외 효소에 의한 볏짚 당화에 관한 연구)

  • Kim, Yoon-Hee;Cho, Moon-Jung;Shin, Keum;Kim, Tae-Jong;Kim, Nam-Hun;Kim, Yeong-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.262-273
    • /
    • 2010
  • In the enzymatic hydrolysis of rice straw and wood meals using extra-cellular enzymes from Fomitopsis palustris, key factors which enhanced the sugar conversion yield were investigated in this work, such as enzyme production and enzyme reaction conditions, surfactant effects, and the surface structure of substrates. F. palustris cultured with softwood mixture produced 12.0 U/$m{\ell}$ for endo-${\beta}$-1,4-gulcanase (EG), 116.68 U/$m{\ell}$ for ${\beta}$-glucosidase (BGL), 18.82 U/$m{\ell}$ for cellobiohydrolase (CBH), and 13.33 U/$m{\ell}$ for ${\beta}$-xylosidase (BXL). These levels of BGL, CBH, and BXL activities were two to four folds more than enzyme activities of F. palustris cultured with rice straw. The optimum reaction conditions of cellulase-RS which produced by F. palustris with rice straw and cellulase-SW which produced by F. palustris with softwood mixture were pH 5.0 at $45^{\circ}C$ and pH 5.0 at $50^{\circ}C$, respectively. The sugar conversion yield of cellulase-SW had the highest value of $40.6{\pm}0.6%$ within 72 h when rice straw was used as substrate. By adding 0.1% Tween 20 (w/w-substrate), the sugar conversion yield of rice straw was increased to 44%, which was about four fifths sugar conversion yield of commercial enzyme, Celluclast 1.5L (Novozyme A/S). A low crystallinity and an intensive fibril surface observed by the scanning electron microscope may explain the high sugar conversion yield of rice straw.

Effect of Humidified High Flow CO2 Gas Insufflation on the Coronary Endothelium (가습화한 고유량의 이산화탄소가스 통기가 관상동맥 내피세포층에 미치는 영향)

  • 최재성;김준성;서정욱;김기봉
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.131-138
    • /
    • 2004
  • High-flow gas insufflation to get a bloodless field during off-pump coronary artery bypass may have adverse effects on the coronary endothelium. This study was designed (1) to elucidate the effect of carbon dioxide gas insufflations on the coronary endothelium at different flow rates and (2) to assess the protective effect of humidifcation against the coronary endothelial damage. Material and Method: In nine pigs, the left anterior descending coronary artery (LAD) was exposed after a median sternotomy. The LAD was divided into 4 segments and a coronary arteriotomy was made in each LAD segment in the beating heart. The far distal arteriotomy was exposed to room air for 10 minutes and was harvested as a control. Non-humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group I), humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group II), and humidified carbon dioxide gas at a continuous flow rate of 10 L/min (Group III) were insufflated for 10 minutes on each coronary arteriotomy site, respectively. After harvesting the coronary segments, hematoxylin-eosin staining, elastic fiber staining, and immunostaining with a CD34 monoclonal antibody were performed to evaluate the depth of endothelial damage and to count the residual endothelial cells, Result: In all three groups (Group I, II, and III), internal elastic laminae were preserved, however, the endothelial layers were significantly damaged by carbon dioxide gas insufflation. The mean percentages of remaining endothelial cells were 20,9$\pm$16.7%, 39.3$\pm$19.6%, and 6.8$\pm$5.3%, in groups I, II, and III, respectively. The percentages of remaining cells were significantly higher in group II than in groups I and III (p=0.008). The percentages of remaining cells were significantly higher in group I than in group III (p=0.008). Conclusions: The harmful effect of carbon dioxide gas insufflation on the coronary endothelium was dependent on the flow rate. The addition of humidification did not protect the coronary endothelium from denudation injury caused by high flow carbon dioxide gas insufflations.

Present Conditions of Mental Health Care in Rural Areas: Community Mental Health Program of Public Health Center (농촌지역 정신보건관리실태: 보건소 지역사회정신보건사업)

  • Lee, Weon-Young;Kim, Dong-Moon
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.2
    • /
    • pp.1-14
    • /
    • 2003
  • Objectives: This paper introduces need and supply level of rural mental health care service and especially focuses on the evaluation for the community mental health programs of Public Health Centers(PHCs) in rural areas as the facilities for primary mental health care. Methods: We defined the need as prevalance rate and service utilization rate, for which reviewed the results of the epidemiological study of mental disorders using Korean Composite International Diagnostic Interview surveyed on a nationwide scale in 2001. Supply was appraised in terms of psychiatric beds and primary mental heath care facilities such as private psychiatric clinics, facilities for social rehabilitation, PHCs running community mental health programs. For this, we reveiwed a variety of annual reports related mental health published by Ministry of Health and Welfare. To evaluate the community mental health programs of PHCs in rural areas, we selected. randomly samples out of the 3rd community health plans including the contents of community mental health programs, which submitted by 89 rural counties and 44 cities mixed with rural areas, and used the program's guideline established by central government as a standard. Results: Prevalence rates of major psychiatric diseases such as schizophrenia, alcoholism, major depression, anxiety disorder were higher in rural area than in urban area and 8.9% of psychiatric patients in both areas stayed at homes contacted with mental health manpower more than one time during the last year. Psychiatric beds were sufficiently supplied, but urban area had less beds than rural area contrary to general health care service. Psychiatric clinics were supplied very insufficiently in rural areas and PHCs bridged the gap instead. However rural PHCs got less financial support for community mental health programs from higher positioned agencies than urban PHCs. Rural community health programs not supported hardly worked out. Conclusions: Central government should consider a special policy for rural primary mental health care, because private psychiatric clinics can't be introduced in rural areas due to demand-deficiency and the financial independence of rural counties was very vulnerable.

  • PDF

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

A HISTOPATHOLOGIC STUDY ON THE PULPAL RESPONSE TO DEMINERALIZED FREEZE-DRIED BONE IN DOGS (탈회냉동건조골에 대한 성견의 치수조직반응에 관한 연구)

  • Jung, Moon-Yong;Lee, Chang-Seop;Park, Joo-Chul;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.318-332
    • /
    • 2000
  • The purpose of this study was to investigate the effects of demineralized freeze-dried bone (DFDB) on mechanically exposed pulp of dog by evaluating the pulpal inflammation and healing process, formation of dental hard tissue, and structural changes of fibroblasts of the remaining pulp tissue. Teeth of 4 dogs, weighing 10kg, were used in this study. Class V cavities were prepared followed by exposed the pulp tissue mechanically by sterilized round bur. In control group, exposed pulps were capped with calcium hydroxide paste followed by sealed with IRM. In experimental groups, the exposed pulps of one group were capped with the collagen and those of the other group were capped with DFDB. All cavities were sealed with same manor as control group. The animals were sacrificed at the intervals of 3, 7, 14, and 28 days for histopathlogic evaluation. The specimens were observed by the light microscope and trans-electron microscope. The results were as follows: 1. Pulp necrosis was not observed in all groups. Inflammatory response was disappeared from 1 week in control group and group 2. But it was not disappeared until 2 weeks and also irregular arrangement of odontoblasts was showed at the lateral walls of root canal just beneath the amputated site of the pulp in group 1. 2. Dentinal bridge was formed incompletely at 2 weeks but it was formed completely at 4 weeks in control group. Odontoid tissue was also found in control group at 4 weeks from treatment. Amputated site of pulp was encapsulated with fibrous tissue and odontoblast and dentinal bridge was not found in group 1. Preodontoid tissue and reparative dentin which were formed by odontoblast differentiated around DFDB were found, but dentinal bridge was not found in group 2. 3. Cell with large basophillic-stained nuclei infiltrated to amputated site and DFDB at 1 week from treatment in control group and group 2. They were found more in group 2 than in control group. Odontoblasts arranged more regularly and reparative dentin was found more as time elapsed. 4. Dentin-formative odontoblasts which showed ultramicrostructure of cytoplasm with polarized nucleus, rEM, Golgi complex, secretory granules, secretion of organic matrix in control of group and group 2. In regards to above results, the demineralized freeze-dried bone(DFDB) induce odontoblastic differentiation and further come up to the dentin formation in amputated pulp.

  • PDF

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.