• Title/Summary/Keyword: 전자파영향

Search Result 827, Processing Time 0.031 seconds

The Analysis of Scattering Characteristics of a Prime-focus Offset Parabolic Antenna with a Shaped Edge Structure (정형 모서리 구조를 갖는 옵\ulcornerV 파라볼릭 안테나의 산란 특성 해석)

  • 박대성;김형규;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.3
    • /
    • pp.412-418
    • /
    • 1999
  • The scattering characteristics of a prime-focus offset-parabolic antenna are analyzed using UTD. First, ray tracing method is used to locate the shadow boundaries, and then UTD is utilized to evalute the far-zone scattered magnetic field pattern. The field components included in the UTD analysis are the reflected, edge diffracted and creeping waves. The effects of circular caps attached to both edges of a prime-focus offset-parabolic antenna are investigated by comparing the scattered magnetic field patterns with those of a knife edge parabolic reflector.

  • PDF

Method of SAR reduction for Wireless Transceiver (무선통신 단말기의 SAR 저감법)

  • Hwang, Jae-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.346-349
    • /
    • 2005
  • In this paper, we propose SAR(Specific absorption rate) reduction methods based on surface electric field distribution relation. Proposed the new method that is able to consider improvement of the SAR from the very beginning step of developing the wireless transceiver. Analysis of wireless handset with human body(head) using finite element method(FEM). Results of this method, SAR reduced about 50 %.

  • PDF

Investigation on Frequency Spectral Characteristics in Switching Frequency Modulation Control (스위칭주파수 변조제어의 주파수 스펙트럼 특성 고찰)

  • 박석하;김양모
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.221-228
    • /
    • 2000
  • 본 논문에서는 전기·전자 장비의 활용이 확대되면서 더욱 더 관심이 고조되고 있는 전자파장해에 대하여 논하고자 한다. 기존 PWM 직류전원장치에서는 회로 소자 및 배치에 따른 기생소자와 갑작스런 전압/전류의 변화에 의해 전자파장해를 발생시킨다. 본 논문에서는 PWM 직류전원장치에서 발생하는 전자파장해의 특성을 고찰하고, 출력전압 조절에 큰 영향을 주지 않는 범위내에서 PWM 제어가 가능하면서 두 개의 고정된 스위칭주파수로 연속적으로 변조하는 Bi-FM 변조제어방식과 랜덤하게 변화하는 스위칭주파수 변조제어방식을 이용하여 전도잡음을 저감시킬 수 있는 변조방식을 논할 것이다. 또한 이들 변조 방식의 주파수 스펙트럼 특성을 비교·분석하여 설명하고, 제어기를 분석·설계하여 실험을 통하여 스위칭주파수와 그 고조파 주파수들의 측대역으로 전도잡음이 분산되고 전도잡음의 피크치가 감소됨을 확인하고자 한다.

  • PDF

Communication Noise Dynamic Cancellation Method for Radar Pulse Detection (레이더 펄스 탐지를 위한 통신 전자파잡음 동적제거 기법)

  • Jeong, Un-Seob;Lee, Chi-Hun;Choi, Chae-Taek;Choi, Seung-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.732-735
    • /
    • 2012
  • 본 논문은 지상에서 발생하는 전자파 잡음 신호의 유입에 의해 많은 영향을 받을 수 있는 헬기 등 항공기의 레이더경보수신기(Radar Warning Receiver)에서도 레이더 펄스 신호를 탐지할 수 있는 통신전자파잡음 동적제거 기법을 제안하였다. 본 논문은 지상의 노이즈 신호를 분류하는 방법을 제시하였고, 노이즈 신호 레벨을 판단하여 효과적으로 잡음을 제거하는 알고리즘을 제안하였다.

Electromagnetic Wave in all Base Stations (다기지국 환경에서 전자파 노출량)

  • Cho, Euy-Hyun;Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.26-44
    • /
    • 2011
  • The Study was carreid out to see whether the intensity of electromagnetic waves in each floor of a building where the sharing base station has been established is harmful to a human body, and to expect the intensity of the waves in the building. The investigate was performed on both of sharing base station either with many scatterers or without any of them. To satisfy the international standard and the domestic TTA standard, rms for each of the electromagnetic wave of every floor in the building with the station was measured from 3 location of 3 heights(1.1m,1.5m, and 1.7m). Max of the measured rsm from the each of the frequencies in the nine location was confirmed to be 48.12%(the rooftop measured value) at most, compared to the human body protection standard. The value was confirmed to satisfy the human body protection standard for each frequency. And the total value of the calculated exposure indexes for each frequency was determined to be more than 7 times lower at most, which was 0.1445, compared to the 1 standard. Since P value in both of 868MHz and 2.14GHz electromagnetic waves intensity for each base station and floor was less than 0.05, it was revealed to be meaningful, and since R-Sq(adj) value showed a value more than 50%, the regression equation was determined to fully absorb the data information. However, although the P value of both of 868MHz and 2.14GHz electromagnetic waves intensities under the integrating terms of the base station data and the floor data was showed to be less than 0,05, since R-Sq(adj) value of 868MHz electromagnetic waves intensity presented a value smaller than 50%(34.15%), it was determined that the 868MHz electromagnetic waves intensity is very much influenced by an environment with a base station. Because the electromagnetic waves intensity of 2.14GHz show R-Sq(adj) value bigger then 50%(51.8%), The regression equation model of 2.14GHz electromagnetic waves intensity was confirmed to be proper. It also turned out not to be effected by the surrounding environment near a building with the base station and the intensity of electromagnetic waves for each floor of such building was expectable by the regression equation.

Measurement of Transfer Impedance on Shielded Multiconductor Telecommunication Cables using IEC 96-1 Line Injection Method (IEC 96-1 Line Injection Method를 이용한 다 도체 통신케이블 차폐층의 전달임피던스 측정)

  • 이현영;오호석;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.377-383
    • /
    • 2003
  • As the high-speed data communications such as xDSL using the existing copper cable come into wide use, the electromagnetic coupling characteristics of telecommunication cables become more significant. In order to describe the screening performance of telecommunication cable, the transfer impedance of cable shield is required. This paper describes the transfer impedance for two types of telecommunication cables using the line injection method of IEC 96-1. Results are analyzed to show how the materials of cable shields, the positioning of the injection line and of the inner conductor of the CUT(Cable Under Test) affect the value of transfer impedance. We then propose the transfer impedance model of telecommunication cable based on the measurements.

Interference Influence Analysis on the Interoperability in the Combined Military Communication Systems (통합 군 통신 시스템에서 상호운용으로 인한 간섭 영향 분석)

  • Kim, Tae-Woo;Kim, Jung;Kwag, Young-Kil
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.365-371
    • /
    • 2014
  • It is essential for the combined military weapon system to be equipped with interoperability for the efficient combat operation in the modern warfare environment. Since most of modern military systems utilize the electromagnetic wave for the radio communication in the network-centric warfare system, they can be vulnerable to the mutual interference among the adjacent combined military systems. In this paper, the typical radio communication systems are modeled with the modulation types of both spread and non-spread spectrum system. The various interference signals were generated for the simulation of the mutual interference influence from the adjacent radar and communication systems. The simulation results show that the detection performance of the victim communication receiver is seriously affected by the various interferences such as the types of modulation and the ratio of the overlapping bandwidth of the adjacent interferers. This result will be useful for defining the criteria of the interference protection in the combined military system for the interoperability in the future.

EMI Reduction Analysis by a Conductor between Frames (프레임을 연결하는 전도체의 구조가 EMI 감소에 미치는 영향 분석)

  • Koh, Eun-Kwang;Shim, Min-Kyu;Hong, Eun-Ju;Lee, Jai-Yeol;Park, Seung-Hun;Kwak, In-Gu;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.263-270
    • /
    • 2008
  • In this paper, we investigated EMI(electromagnetic interference) reduction by conductor connection, which was used for fixing and electrical grounding between frames. Conductor connects two frames and then it provides the decrease of return path of signal current. To prove the effect of conductor, we measured/simulated the RE(radiated emission) with/without conductors between the two frames. From the measured/simulated results, we observed that EMI decreased about 1$\sim$10 dB at the frequency range of 30 MHz to 1 GHz. VNA(vector network analyzer) was used to measure the S parameters and the RE was measured in a 3 m anechoic chamber. The simulated and measured results are compared and discussed.

Analysis of impact of CATV leakage on CDMA Mobile Communication Systems (CDMA 이동통신시스템에 대한 케이블 방송 전송설비 누설전자파 영향 분석)

  • Park, Seong-Gyoon;Han, Chan-Kyu
    • Journal of IKEEE
    • /
    • v.15 no.3
    • /
    • pp.218-226
    • /
    • 2011
  • In this paper, the leaky electric field intensity of outdoor CATV facilities on CDMA mobile service band defined in technical regulation related with CATV is investigated if appropriate or not. From experimental and theoretical analysis results, Maximum allowable power level of CATV leakage should be -110dBm/1.23MHz. Also, the CATV leakage intensity thresholds, which may not nearly give an impact on the uplink performance of CDMA mobile base station for outdoor background noise of -100~-80dBm/1.23MHz to be measured in outdoor environment, couldn't conform to the current CATV technical regulation. Therefore, the leakage intensity in the current CATV technical regulation is rated as a too much low level in view of an overly worst case.

EMC 관련 최근 기술 동향 - CISPR 20 방사내성 Round Robin Test 결과 및 분석

  • Jang, Tae-Heon;Jo, Won-Seo
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.60
    • /
    • pp.48-52
    • /
    • 2006
  • 2006 CISPR 총회가 스웨덴 스톡홀름 KISTA에서 개최되었다. CISPR I 회의는 9월 18일부터 20일까지 3일간 WG2 및 WG4를 중심으로 진행되었으며, WG1과 WG3 회의는 9월 20일 오후에 있었다. 우리나라에서는 WG1에 두 가지 제안을 발표하였다. 하나는 2004년 중국 상해 회의에서 처음 제안하여 2005년 남아공 케이프타운 회의에서 Task Force가 구성된 대형 시험품에 대한 CISPR 20의 외부 방사내성 시험레벨에 관한 것이다. 2006년 1월 미국 산타페에서 열린 TF 회의에서 시험결과에 대한 기술적 토론이 있었으며, Round Robin Test(RRT)를 실시하기로 결정되었다. RRT시험은 7월 중순에 실시되었으며, 참여한 시험소는 영국의 SONY, 네덜란드의 Philips, 독일의 SHARP 이었으며, 국내의 여러 EMC 시험소도 추후에 참여하였다. RRT 시험의 결과 및 분석이 이번 스톡홀름 회의에서 발표되었다. 또한, CISPR 13의 방사성 방출(RE)의 측정거리 기준점의 변경에 관한 것이다. 본 고에서는 TV 수신기에 대한 RRT 시험결과 및 분석에 대한 발표 내용을 소개하고자 한다. CISPR 20의 외부 전자기장 내성 시험은 0.8 m인 개방형 스트립라인(Open Strip-line: OSL)내에 시험품을 설치하고 $150kHz{\sim}150MHz$에서 시험하도록 규정하고 있다. OSL에 설치할 수 없는 대형기기는 IEC 61000-4-3에 따라서 주파수 범위 $80MHz{\sim}150MHz$까지 동일한 한계치로 전자파무반사실에서 시험하도록 규정되어 있다. 이에 대해 국내 제조업체 및 EMC 전문가들로 구성된 CISPR I 국내 위원회에서는 IEC 61000-4-3에 의한 전자파무반사실(챔버)에서의 내성시험이 CISPR 20에 의한 OSL에서의 내성시험보다 가혹하다는 문제 제기가 있었다. 이것이 본 안건에 대한 배경이다 지금까지 진행되어 왔던 내용을 요약해 보면 2004년 상해 회의에서, 수치해석 및 측정비교를 통하여 CISPR 20에서 규정하고 있는 OSL 전기장 교정방법의 개선의 필요성과 OSL에서 시험할 수 없는 대형 시험품에 대하여 시험레벨을 조정할 것을 지적하였다. 2005년 케이프타운 회의에서는 실제적으로 TV 방송 수신기 및 관련기기가 두가지 방법으로 시험되었을 때 시험결과에 미치는 영향을 시험품의 전기장 내성 레벨로 비교하였으며, 전자파무반사실에서 시험할 경우 시험레벨이 12 dB 낮추도록 보정되어야 할 것을 제안하였다. 2006년 이번 회의에서는 세계 각국의 시험소와 비교시험을 통하여 나타난 OSL과 전자파무반사실 간의 시험결과의 차이 및 이에 대한 원인을 분석하여 보고하였다. OSL과 전자파무반사실 비교시험에서 나타난 차이는 평균적으로 9 dB의 차이로 나타났으며, 주요 원인은 OSL에서 적용하고 있는 시험품을 OSL내부에 설치한 후 시험품에 의해 변경된 전기장의 세기를 보정해 주는 인자(k2)로 인한 차이(6 dB)와 OSL 내부의 전기장의 세기와 전자파무반사실 균일장 영역의 전기장의 세기의 차이(3 dB)이다.