Measurement of Velocity Profile in Liquid Metal Flow Using Electromagnetic Tomography (전자기 토모그래피를 이용한 액체 금속 속도장 측정)

  • Choi, Sang-Ho;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1749-1754
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output for a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was $54^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

  • PDF

Flow Measurement in Bubbly and Slug Flow Regimes Using The Electromagnetic Flowmeter Developed (전자기유량계를 이용한 기포 및 슬러그 유동 측정방법 연구)

  • Cha, Jae-Eun;Ahn, Yeh-Chan;Seo, Kyung-Woo;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1559-1569
    • /
    • 2002
  • In order to investigate the characteristics of electromagnetic flowmeter in two -phase flow, an AC electromagnetic flowmeter was designed and manufactured. In various flow conditions, the signals and noises from the flowmeter were obtained and analyzed by comparison with the observed flow patterns with a high speed CCD camera. The experiment with the void simulators in which rod shaped non-conducting material was used was carried out to investigate the effect of the bubble position and the void fraction on the flowmeter. Based on the results from the void simulator, two -phase flow experiments encompassed from bubbly to slug flow regime were conducted. The simple relation $\Delta$ $U_{TP}$ = $\Delta$ $U_{SP}$ (l-$\alpha$) was verified with measurements of the potential difference and the void fraction. Due to the lack of homogeneity in a rent two -phase flow, the discrepancy between the relation and the present measurement was slightly increased with void fraction and also liquid volumetric flux jf. Whereas there is no difference in the shape of the raw signal between single-phase flow and bubbly flow, the signal amplitude for bubbly flow is higher than that for single -phase flow at the same water flow rate, since the passage area of the water flow is reduced. In the case of slug flow, the phase and the amplitude of the flowmeter output show dramatically the flow characteristics around each slug bubble and the position of a slug bubble itself. Therefore, the electromagnetic flowmeter shows a good possibility of being useful for identifying the flow regimes.ul for identifying the flow regimes.

전자펌프의 원리 및 기술개발 현황

  • 김동화
    • 전기의세계
    • /
    • v.39 no.9
    • /
    • pp.35-38
    • /
    • 1990
  • 전자펌프(Electromagnetic)는 액체금속의 도전성을 이용하는 것으로 종래의 기계식에 비해 회전부가 없고 기밀을 요하는 패킹장치 등이 없어 보수가 필요없을 뿐 아니라 동작시 유도전압 조정기를 이용하여 유량제어를 쉽게 할 수 있는 등 많은 장점이 있다. 따라서 신뢰성과 안전성이 요구되는 고속증식로, 인공위성과 같이 액체금속을 냉각재로 사용한는 시스템의 펌프에는 물론 알루미늄, 납, 수은 등과 같이 산업계에서 많이 쓰이는 용융금속의 수송에도 대단히 중요한 장치이다. 그러나 전자펌프는 구조상 2차측(액체금속)과 펌프닥트등에서의 손실이 대단히 클 뿐 아니라 전자펌프의 이용 특성상 높은 온도에서 사용해야 하므로 절연 및 내열재료 특성에도 아직 연구되어야 할 과제가 많다. 본 난에서는 이러한 관점에 입각하여 전자펌프의 기본원리를 기술하고 국내외의 연구현황 및 전망을 고찰하여 보고자 한다.

  • PDF

Thermal Plasma Synthesis of Nano Composite Particles (열플라즈마에 의한 복합 나노 입자 제조)

  • Jeong, Min-Hee;Kim, Heon-Chang
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.676-679
    • /
    • 2010
  • Nano composite particles were synthesized from a bulk ZrVFe alloy ingot by transferred DC thermal plasma. Effects of plasma gas flow rate on the characteristics of the produced nano composite particles were investigated. The characteristics of the synthesized powder were analyzed by field scanning electron microscopy (FE-SEM), light scattering particle size analyzer (PSA), energy dispersive X-ray spectroscopy (EDS), X-ray diffractometer (XRD), and Brunauer-Emmett-Teller (BET) surface area analyzer. As the flow rate of plasma gas increased from 20 L/min to 40 L/min, the average particle size decreased from 91 nm to 55 nm, the particle size distribution became narrower, the surface area increased from $200\;m^2/g$ to $255\;m^2/g$, the particle composition was nearly unaffected, and the particle crystallinity was improved.

실시간 수문자료의 특성분리를 통한 예측성능의 향상

  • Hwang, Seok-Hwan;Kim, Chi-Yeong;Cha, Jun-Ho;Jeong, Seong-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.128-128
    • /
    • 2011
  • 본 연구에서는 자동유량측정시설에 의하여 실시간으로 생산되는 자동유량측정 자료의 정상성 여부를 판단하는데 중요한 적정 측정 신뢰구간을 실시간으로 예측할 수 있는 기술을 개발하였다. 전세계적으로, 현대적인 유량측정이 시작된 이래 연속유량 산정을 위한 방법은 수위-유량관계곡선을 이용하는 방법 외에 실무적으로 활용 가능한 방법은 거의 전무한 실정이다. 수위-유량관계곡선을 이용하는 방법은 연속수위를 계측하여 이에 해당하는 연속유량을 산정하는 방법으로 수위와 유량간에 일정한 관계를 가지는 정상적인 흐름을 보이는 자연하천의 경우에 정확도가 매우 높다. 그러나 감조나 구조물 등에 의해 유량이 조절되는 경우에 유량산정의 정확도는 현저히 떨어지게 된다. 따라서 수위에서 유량을 환산하는 방법이 아닌 유량을 직접 연속으로 측정하는 방법이 꾸준히 연구되어 왔고, 이 중 가장 대표적인 방법이 자동유량측정 방법이다. 그러나 자동유량측정 방법은 유량을 연속으로 측정할 수 있다는 장점에 반해 측정된 유량의 정확도를 높이기가 매우 어렵다는 단점도 가지고 있다. 계측 자체의 기술적 한계는 주로 계측기기적인 문제로 이는 전자기, 통신 기술 등 첨단 기술의 발전과 함께 다양한 현장 시험을 통해 폭넓은 개선이 이루어지고 있다. 그러나 아직 기술적 완성도가 완전하지 못한 현실에서, 현재 설치되어 있는 자동유량측정 유량자료의 신뢰도를 높이기 위해서는 각각의 계측 시점에서 자료가 정상적으로 산정되고 있는지에 대한 검정이 필요하고, 이는 자동유량측정 자료의 정확도 확보에 매우 중요한 관건으로 작용할 수밖에 없다. 이러한 배경에서 본 연구에서는 조석성분과 유출성분을 분리하여 예측하는 방법을 새롭게 개발 적용하였다. 자료는 자료의 시간해상도 증감에 따른 실제 예측의 정확도 증감을 고려하여 가장 적절하다고 판단되는 시자료를 사용하였으며, 자료간 상관을 분석하여 주 입력 자료로 팔당댐 방류량, 한강대교 지점 수위, 전류 수위를 이용하였다. 모형의 예측 능력을 극대화하기 위하여 조석 영향을 받는 자료의 경우는 웨이블릿 변환(wavelet transform)을 이용하여 순수 유출성분과 조위성분을 분리하여 별도로 적용하였다. 그리고 예측을 위한 모형은 실시간 자료기반 모형으로 그 안정성이 인정된 서포트벡터머신(support vector machine)을 이용하였다. 이러한 과정을 통해 한강대교 지점의 순수 유출성분과 조위성분의 유량을 각각 예측한 후 두 결과를 합성하여 최종 한강 대교 지점의 유량을 산정하였다. 조석성분을 분리하여 한강대교 지점의 유량을 예측한 결과 대부분의 예측치가 95% 예측구간에 포함되었다. 그리고 조석성분을 분리하지 않은 모형과 조석성분을 분리한 모형의 예측 능력을 비교한 결과, 조석성분을 분리한 모형이 예측이 정확도가 높았다. RMSE의 경우 분리하지 않은 모형대비 23%의 예측오차가 감소하였고, NSC의 경우 0.92에서 0.95로 예측의 정확도가 증가하였다.

  • PDF

A Study on Design and Development of the Electronically Controlled Power Steering Controller far a Passenger Car (승용차용 전자계어식 파워스티어링 콘트롤러의 설계 및 개발에 관한 연구)

  • 김광열;김태훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.166-174
    • /
    • 2002
  • Power steering systems far automobile are becoming ever more popular because they reduce steering efforts of the drivers, especially during parking lot maneuver. In this paper, the controller of the motor driven hydraulic power steering(MDHPS) has been designed and developed. This system uses a power source of DC motor instead of engine power source for power steering drive oil pump. The developed MDHPS system is accomplished a highly sensitive power steering resulted from electronic control under variable driving condition. Furthermore, this system is more improvement than type of engine driving far fuel economy.

Adaptive Control of a Multivariable System Using $\mu$-Computer (마이크로콤퓨터를 이용한 다변수 시스템의 적응제어에 관한 연구)

  • Kim, Young-Key;Bien, Zeungnam
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.5
    • /
    • pp.27-33
    • /
    • 1979
  • It is reported that a typical multivariable system of chemical process type was constructed and control experiment was conducted using a $\mu$-computer instead of using conventional hardwave controller. When the pressure of water to be supplied to the multivariable system is varying, an adaptive control method using a flowmeter is suggested to enhance the control performance.

  • PDF

대기압 저온 아르곤 플라즈마 제트의 분광 분석

  • Han, Guk-Hui;Kim, Yun-Jung;Kim, Jung-Gil;Kim, Yeon-Jeong;Jo, Hyeon;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.191-191
    • /
    • 2016
  • 대기압 저온 Ar 플라즈마 제트에서 발생되는 플라즈마에 대해 연구하였다. 플라즈마 제트의 본체는 주사기 바늘, 유리관 그리고 테프론 튜브로 구성되어 있다. 바늘의 앞부분은 유리관에 삽입되어 있으며 바늘의 뒷부분은 테프론 튜브와 연결되어 있다. 주사기 바늘에는 수십 kHz의 사인파를 발생시키는 DC-AC 인버터로 수 kV의 고전압을 인가해준다. 기체는 테프론 튜브를 통해 바늘의 안쪽으로 흐른다. 사용 기체는 Ar이며 유량은 3 lpm이다. 주사기 바늘형 전극의 내경은 1.3 mm, 외경은 1.8 mm, 총 길이는 39.0 mm이며 재질은 스테인레스강이다. 유리관의 내경은 2.0 mm, 외경은 2.4 mm, 총 길이는 80.0 mm이다. 자외선-근적외선 분광계를 이용하여 대기압 저온 Ar 플라즈마 제트에서 발생된 플라즈마의 분광 분석을 하였다. 플라즈마 제트에서 발생되는 플라즈마의 휘도는 대략 $10{\sim}30cd/m^2$이다. 플라즈마의 측정 위치, 플라즈마 제트의 입력 전압과 입력 전류, 기체 종류 등의 변수에 따른 분광 실험을 하였으며 이를 통해 얻은 분광 데이터를 일반적인 볼츠만 기울기법에 대입하여 플라즈마의 들뜸 온도를 측정하였다. 또한 Ar 플라즈마 제트의 분광 데이터를 수정된 볼츠만 기울기법에 대입하여 플라즈마의 전자 온도를 측정하였다. 이는 바이오-의료용 플라즈마 및 플라즈마 공정 등의 다양한 응용 분야에서 유용하게 활용할 수 있을 것이다.

  • PDF

Fabrication of Single Capacitive type Differential pressure sensor for Differential Flow meter (차압식 유량계를 실장을 위한 Single Capacitive Type Differential 압력 센서 개발)

  • Shin, Kyu-Sik;Song, Sangwoo;Lee, Kyungil;Lee, Daesung;Jung, Jae Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • In this paper, we have developed a differential pressure flow sensor designed as a single capacitive type. And the sensor was fabricated using a MEMS process. Differential pressure flow sensors are the most commonly used sensors for industrial applications. The sensing diaphragm and bonding joint of the MEMS pressure sensor are easily broken at high pressure. In this paper, we proposed a structure in which the diaphragm of the sensor was not broken at a pressure exceeding the proof pressure, and the differential pressure sensor was designed and manufactured accordingly. The operating characteristics of the sensor were evaluated at a pressure three times higher than the sensor operating pressure (0-3 bar). The developed sensor was $3.0{\times}3.0mm$ and measured with a LCR meter (HP 4284a) at a pressure between 0 and 3 bar. It showed 3.67 pF at 0 bar and 5.13 pF at 3 bar. The sensor operating pressure (0-3 bar) developed a pressure sensor with hysteresis of 0.37%.

Analysis of Daily Milking Flow in Holstein Dairy Cow Using the LactoCorder (전자식유량계를 활용한 홀스타인 젖소의 비유형질 분석)

  • Cho, Kwang-Hyun;Choi, Jun-Pyo;You, Byung-Wha;Lee, Deuk-Hwan;Kong, Hong-Sik;Park, Kyung-Do;Lee, Hak-Kyo
    • Journal of Animal Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.265-272
    • /
    • 2009
  • A total of 486 milk records were collected from 16 diary farms in Imsil-gun, Jeollabuk-do. Results obtained were as follows: The average 3MG (amount of milk within the first three minute) was 7.44 kg and 55% of total milk yield was produced within 3 min. The average of SPL (% of foam in milk) was 33.93% and the average of MNG (strip yield) was 0.14 kg, which was less than 1% of total milk yield. The averages of HMF (highest milk flow), HMG (maximum milk flow rate in one minute) and DMHG (average milk flow in the main milking phase) were 3.03 kg/min, 2.94 kg/min and 2.05 kg/min, respectively and the average milking speed in Imsil-gun was slower than other regions. The average of tS500(time to reach 0.5 kg/min at beginning) was 0.23min (about 14 seconds) and that of tMGG (duration of the total milking) was 7.75min. The average tMBG (duration of the dry milking phase) was 0.58 min (35 seconds) and that of tMNG (duration of the stripping phase) was 0.42min (14 seconds). The averages of ELHMF (electrical conductivity at highest milk flow) and ELAP (beginning peak level of the electrical conductivity) were 6.81 mS/cm and 7.58 mS/cm, respectively. The average of ELMAX (maximum electrical conductivity) was 7.48 mS/cm and that of ELAD (beginning peak difference of the electrical conductivity) was 0.61 mS/cm. While the total milk yields for DMHG, tMHG (duration of the main milking phase), tPL (duration of the plateau phase), tAB (duration of the descending phase) and tMGG were positively correlated (0.35~0.54), those for tMBG and SPL were negatively correlated (-0.11 and -0.27). As the DMHG increased, tMHG, tPL, tAB, tMGG and SPL decreased. While the cows with higher electrical conductivity at the beginning of milking had less somatic cell counts, cows with higher electrical conductivity after the peak of milk yield had more somatic cell counts. The results of this experiment indicated that through milking based on milking and lactating standards and the regular checking of milking status, the qualities of milk and milk yields could be improved.