• Title/Summary/Keyword: 전원 관리 시스템

Search Result 275, Processing Time 0.027 seconds

A Proposal of the Prediction Method of Decentralized Power on Climatic Change (기후 변화에 따른 분산 전력 예측 방법 제안)

  • Kim, Jeong-Young;Kim, Bo-Min;Bang, Hyun-Jin;Jang, Min-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.942-945
    • /
    • 2010
  • The development of decentralized power has appeared as part of an effort to decrease the energy loss and the cost for electric power facilities through installing small renewable energy generation systems including solar and wind power generation. Recently a new era for decentralized power environment in building is coming in order to handle the climatic and environmental change occurred all over the world. Especially solar and wind power generation systems can be easily set up and are also economically feasible, and thus many industrial companies enter into this business. This paper suggests the overall architecture for the decentralized renewable power system and the prediction method of power on climatic change. The ultimate goal is to help manage the overall power efficiently and thus provide the technological basis for achieving zero-energy house.

  • PDF

A Study on Data Acquisition System for Battery Automatic Charging and Discharging (배터리의 자동 충방전 데이터 수집 장치에 관한 연구)

  • Lee, Kyung-Sung;Moon, Chae-Joo;Jeong, Moon-Seon;Kim, Sang-Man;Youn, Young-Chan;Kim, Tae-Gon
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.70-71
    • /
    • 2011
  • 최근 신재생에너지에 대한 관심이 높아지면서 에너지 저장 장치로 친환경적인 2차 전지가 전기 에너지 저장 매체로 관심을 받고 있다. 2차 전지는 다양한 전자기기의 구동전원으로 널리 사용되고 있다. 2차 전지의 수명은 충방전과 관련이 있으며, 특히 니켈 수소 전지의 경우 과충전에 의한 온도 상승은 배터리 수명에 직접적인 영향을 준다. 경제성을 고려할 때 2차 전지는 배터리 관리 시스템을 필요로 하며, 충방전 전압과 전류 및 온도를 고려하여 충방전이 제어 되어야 한다. 본 논문은 범용 프로세서와 전압 전류 센서 및 온도센서를 사용하여 배터리의 자동 충방전 데이터 수집장치를 개발에 관한 것이다. 충방전 전압은 0.5V에서 15V까지 설정이 가능하도록 설계하였다. 제작된 장치로 충방전에 따른 배터리의 온도 변화가 측정 및 분석 가능 하였으며, 배터리 전압은 5mV 단위로 충방전이 가능함을 확인하였다.

  • PDF

Development of Monitoring for secondary-battery-system using LabVIEW (LabVIEW를 이용한 2차전지의 상태 감시제어장치에 관한 연구)

  • Kim, Sun-Young;Sin, Kun;Kim, Byung-Mok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.85-88
    • /
    • 2011
  • 석유 등 화석연료로 인한 지구온난화 문제와 더불어 일본 대지진 이후 원자력발전의 안전에 의문이 제기 되면서 신재생에너지에 대한 관심이 한층 고조되고 있다. 이에 발맞추어 국가정책으로 녹색성장 정책이 실행됨에 따라 2030년까지 전체 에너지원 중 신에너지전원의 비중을 전체 에너지원의 11%로 확대하는 정책을 적극적으로 추진하고 있다. 따라서 신재생에너지를 통하여 얻은 전기에너지를 저장하여 사용 할 수 있는 2차 전지에 대한 연구가 다수의 산업 현장에서 각광을 받고 있다. 최근 2차 전지는 Smart Grid 및 전기자동차분야에서 폭넓게 사용 되면서 정확한 출력전압, SOC 및 충-방전 예상 시간을 추정하여 2차 전지의 과충전, 과방전으로 인하여 생기는 고장 및 사고를 미연에 방지하고 2차 전지 사용 시 편의성을 제공하기 위한 시스템에 대한 연구가 필요한 실정이다. 본 논문은 이런 실정에 맞추어 LabVIEW 프로그램을 활용하여 2차 전지의 상태를 실시간으로 감시 및 제어하는 프로그램을 제작함으로써, 사고 시 2차 전지에 가해지는 피해 방지 및 관리 시 발생하는 여러 문제점에 대한 효율적인 해결 방안을 제시하고자 한다.

  • PDF

Implementation of Automatic Power Management System using the Arduino and Beacons (아두이노와 비콘을 활용한 자동 전원 관리 시스템의 구현)

  • Kang, Bong-Gu;Yeo, Junki;Shim, Jaechang
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1471-1478
    • /
    • 2016
  • In this study, the system to manage the power automatically was implemented by using Arduino, Raspberry pi, and Beacon technologies. Before the research, pre-research was carried out with the analysis on the existing power management systems in the market in order to find a solution to reduce burdens from standby power and power waste with the increase of electric charges. The system is designed to be able to deliver and receive data through IEEE 802.15.4 wireless protocol, by using Xbee module. Arduino was tested to verify whether it is able to control SSR(Solid State Relay), and it was found that there is no problem. Meanwhile, it was also tested whether it is possible to organize a star topology network through Arduino and Raspberry Pi, and it was confirmed that normal wireless communication is possible through IEEE 802.15.4 wireless protocol. It is designed that the signal from Android smartphone application is to be delivered to Raspberry Pi and then, to be delivered to Arduino through Xbee so that Arduino could control SSR. In addition to this, wireless protocol required to control Arduino with Raspberry Pi is also designed and applied to this research.

Safeguard Memory Operation for LEO Stellite (저궤도위성 세이프가드 메모리 운영)

  • Chae, Dong-Seok;Yang, Seung-Eun;Cheon, Yee-Jin
    • Annual Conference of KIPS
    • /
    • 2012.11a
    • /
    • pp.8-10
    • /
    • 2012
  • 위성을 전체적으로 제어하는 탑재소프트웨어가 동작하는 주 메모리와는 별도로 세이프가드 메모리가 있다. 세이프가드 메모리는 주로 위성의 장애관리를 위해 사용되는 것으로 프로세서 리셋 시에 전체적으로 초기화가 수행되는 주 메모리와는 달리 별도의 전원을 사용하여 항상 Power-ON 상태를 유지하고 주/부 2개의 메모리가 주/부 프로세서와 Cross-Strap으로 연결되어 어느 프로세서에서든 접속이 가능하도록 구성되어 있다. 위성에 심각한 장애가 발생하여 정상적인 운영이 불가능한 경우, 위성은 Fail-over 과정을 거치게 되는데, Fail-over 과정에서 2개의 세이프가드 메모리의 비상운영데이터 영역에 장애 발생원인 및 프로세서 리셋 이후에 필요한 정보들을 기록하고, 미리 정해진 Backup 하드웨어를 이용하여 시스템 초기화가 수행된다. Backup 하드웨어를 통하여 프로세서가 정상적으로 Boot-up되면 세이프가드 메모리에 저장된 비상운영데이터를 이용하여 위성의 장애발생 원인을 파악하고, 정상운영모드로 복귀하는 절차를 거치게 된다. 본 논문은 저궤도 위성에서 사용되는 세이프가드 메모리 운영방식에 대해 기술한 것이다.

A Study on Transmission Efficiency of Wireless Power Induction and Resonant Charging Methodologies (무선 유도 및 공진 충전방식의 전송효율 연구)

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.747-750
    • /
    • 2019
  • Wearable devices have become practically indispensable to daily life and helped people track and manage fitness, health, and medical functions etc. As these wearable devices become smaller and more comfortable for the user, the demand for longer run time and charging ways presents new challenges for the power management engineer. Wireless power transfer (WPT) is the technology that forces the power to transmit electromagnetic field to an electrical load through an air gap without interconnecting wires. This technology is widely used for the applications from low power smart phone to high power electric railroad and main electrical grid. There are two kinds of WPT methods: Inductive coupling and magnetic resonant coupling. The model using magnetic resonant coupling method is designed for a resonant frequency of 13.45 MHz. In this study, the hardware implementations of these two coupling methods are carried out, and the efficiencies are compared.

Study of Fire Examples for Electrical Wire Short and Insulated Coating Melting by Heating Including Automotive Engine Room (자동차 엔진룸 관련 전기 배선의 단락 및 열에 의한 절연피복 용융에 대한 화재사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Youm, Kwang Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.15-19
    • /
    • 2013
  • This paper is to analyze and study the cause of fire examples produced because of short phenomenon by electric connecting damage and contacting engine over-heating with combustible materials in engine room of vehicle. In the first example, it knew the fact that the fire produced by contacting with body of vehicle because of loosed of bracket bolt for wire fixing that installed on the transmission case the battery power cable supply the power from battery of engine room to starting motor. In the second example, it certified the fire by short phenomenon because of insulation tape melting wound wiring lined from battery to starting motor. In the third example, it sought for fire's cause that melting phenomenon the wire coating by overheated engine as the wire disconnected with connector by the vibration. Therefore, the fire of system including engine electric made in the danger the people in the car by failure of engine and other system. And than, the car's driver must manage and examine a vehicle conscientiously.

소형위성 ETB에서의 전력계 기능시험

  • 윤영수;박종오;최종연;권재욱;안재철;조승원;김영윤
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.91-91
    • /
    • 2003
  • 위성을 발사하기 전까지는 지상에서 EGSE(Electrical Ground Support Equipment)를 이용하여 충분한 시스템 단위의 위성체 기능 시험을 수행한다. KOMPSAT-2(Korea Multi-Purpose Satellite - 2)와 같은 소형 위성의 서브시스템 각각이 요구사항에서 제시하는 규격을 만족하는지 여부를 점검하는 단계에서 전력계 관련 서브시스템의 기능 시험도 EPS(Electrical Power Subsystem) Test Plan에 의해 순차적으로 수행한다. KOMPSAT-2 ETB(Engineering Test Bed)에서의 전력계 시험은 먼저 Test Fuse Modules Check를 수행하였다. 퓨즈 모듈은 PCU(Power Control Unit) 상에 설치되어 있는 장치로써 퓨즈 모듈의 입력과 출력 사이에 도통성 및 다른 출력과의 절연성을 검증한다. 다음으로 EGSE 중 PMTS(Power Monitor Test Set)와 PCU와의 직렬 인터페이스를 점검하는 PCU Interface Check를 수행하였다 시험절차서에 따라 PCU가 가지는 릴레이 스위치에 대하여 명령어를 보내어 릴레이의 동작 상태 및 출력 전압 등을 점검한다. 다음 단계에서는 DC Integration을 수행하여 ETB 하니스 중 전원 관련 라인을 점검하였다 PCU는 모든 위성체 하드웨어에 전력을 공급하는 장비로써 과전력으로부터 하드웨어를 보호하기 위하여 하니스를 연결하기 전에 우선적으로 시험한다. 다음으로는 ECU(EPS Control Unit)가 각각에 해당하는 하드웨어에 명령어를 보내어 전력계 전체적인 동작 상태 검증하는 EPS Hardware Command & Telemetry Checkout을 수행하였다. ECU는 전력계의 모든 하드웨어를 제어하고 그 상태를 모니터링하는 기능을 한다. PCU와의 인터페이스를 통하여 전력의 제어 및 분배에 관련되는 특성을 제어 및 모니터하며 DDC(Deploy Device Controller)는 ECU로부터 명령어를 받아서 arm 및 safe 상태에 대한 텔리 메트리 데이터를 제공한다 그리고, SAR(Solar Array Regulator)는 ECU로부터 Bypass Relay 및 ARM Relay에 관한 명령어를 받아 수행되며 그에 따른 텔리 메트리 데이터를 제공한다. 마지막으로 EPS 소프트웨어를 검증하는 EPS Software Verification을 수행하였다 전력계 소프트웨어의 설계의 검증 부분은 현재 설계 제작된 전력계 .소프트웨어의 동작 특성 이 위성 의 전체 운용개념과 연계하여 전력계 소프트웨어가 전력계 및 위성체의 요구조건을 만족시키는지를 확인하는데 있다. 전력계 운용 소프트웨어는 배터리의 충ㆍ방전을 효율적으로 관리해 3년의 임무 기간동안 위성체에 전력을 공급할 수 있도록 설계되어 있다

  • PDF

Automated Maintenance Inspection System for Unmanned Surveillance Equipment (무인감시설비를 위한 유지보수 자동화 점검 시스템)

  • Chae, Min-Uk;Lee, Choong Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Recently, unmanned facilities have been introduced and operated in a way that reduces the cost and development of IT technology. Although unmanned facilities have advantages in terms of efficiency and economy, they have disadvantages such as failure of unmanned facilities and malfunctions, causing damage to facilities caused by intruders, and information leakage. In addition, it is necessary to visit the person in charge at all times to inspect the unmanned facilities, resulting in management costs. In this paper, we designed a system that checks the status of unmanned surveillance facilities in real time to check and automatically recover problems such as malfunctions, and to notify managers of situations by text messages in real time. The system to be designed consists of an integrated network video server (NVR) that receives and determines information on the operation status of the main equipment such as video, sound, and lighting, and a real-time text message using an SMS server.

A Study on IoT/LPWA-based Low Power Solar Panel Monitoring System for Smart City (스마트 시티용 IoT/LPWA 기반 저전력 태양광 패널 모니터링 시스템에 관한 연구)

  • Trung, Pham Minh;Mariappan, Vinayagam;Cha, Jae Sang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.1
    • /
    • pp.74-82
    • /
    • 2019
  • The revolution of industry 4.0 is enabling us to build an intelligent connection society called smart cities. The use of renewable energy in particular solar energy is extremely important for modern society due to the growing power demand in smart cities, but its difficult to monitor and manage in each buildings since need to be deploy low energy sensors and information need to be transfer via wireless sensor network (WSN). The Internet of Things (IoT) / low-power wide-area (LPWA) is an emerging WSN technology, to collect and monitor data about environmental and physical electrical / electronics devices conditions in real time. However, providing power to IoT sensor end devices and other public electrical loads such as street lights, etc is an important challenging role because the sensor are usually battery powered and have a limited life time. In this paper, we proposes an efficient solar energy-based power management scheme for smart city based on IoT technology using LoRa wide-area network (LoRaWAN). This approach facilitates to maintain and prevent errors of solar panel based energy systems. The proposed solution maximizing output the power generated from solar panels system to distribute the power to the load and the grid. In this paper, we proved the efficiency of the proposed system with Simulink based system modeling and real-time emulation.