• Title/Summary/Keyword: 전원공급시스템

Search Result 571, Processing Time 0.025 seconds

A Analysis on the Result of CE/CS Test on the KOMPSAT-I ETB (아리랑1호 위성 ETB의 전도성 전자파 환경 시험결과 분석)

  • 임성빈;천용식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.184-192
    • /
    • 2001
  • In this paper, we analyze the result of the conduced emission and susceptibility tests performed on the KOMPSAT-I ETB Platform. The ETB platform consists of the EM (Engineering Model) boxes developed to perform the electrical functional test. During the conducted emission test, we measured the instant waveform in time domain when each switch was turn on, and spectrum of the noise in the frequency range of 10 Hz up to100 MHz fur the steady state of the ETB. During the conducted susceptibility test, no malfunction and no serious damage of the electronic box were observed when a simulated noise waveform was applied to the DC power bus. The simulated waveform was obtained by adding the 6 dB-system margin to the worst case waveform measured from the conducted emission. This test was performed as co-development of the KOMPSAT-I with TRW in USA.

  • PDF

Use of Piezoelectric Effect in Portable Loadless Wind-Power Source for Ubiquitous Sensor Networks (유비쿼터스 센서네트워크를 위한 압전효과 기반의 무구속 휴대용 풍력 전원 장치)

  • Chang, Hyung-Kwan;Kim, Dae-Joong;Park, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.623-628
    • /
    • 2010
  • This paper presents a wind-power-driven portable power source based on piezoelectric effect. Positive piezoelectric effect is one of efficient and widely used mechanisms for converting mechanical energy to electrical energy. However, for this mechanism, a periodic mechanical stress with a high frequency, as in the case of AC, has to be exerted; such stress cannot be exerted by the natural wind in the environment. The natural wind has a constant velocity with slow and irregular variations, as in the case of DC. In this paper, we propose a novel and simple mechanism to convert mechanical energy into electrical energy. The DC-like wind flow is passed through a propeller to convert it to an AC-like wind flow; the resultant AC-like periodic flow induces vibrations in a piezoelectric cantilever, thereby, generating electrical power. This system is expected to be one of practical solutions for wireless energy supply to ubiquitous sensor networks (USNs).

A Study on the Development of Electric Signal Measuring Device Using a Smart Phone (스마트 폰을 이용한 전기신호 측정기 개발에 관한 연구)

  • Son, Young-Dal;Eun, Chang-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.9-17
    • /
    • 2017
  • In this paper, we propose a method to develop a multimeter which is used for measuring electric signals in industrial field by using battery and display of smart phone. Most of the multimeters that are linked to existing smartphones are connected to Bluetooth, which is inconvenient for battery use and low in measurement accuracy. To improve this, we developed smart multimeter that can supply power and data at the same time by USB OTG method which can be used by sharing the power of smartphone. We also developed a smart multimeter that can measure resistance, DC voltage, current, AC voltage and current. Developed an Android app with a button that displays measurement data and can select the type of electric signal to be measured, and tests whether the manufactured system is operating normally or not. Respectively.The results of this study confirm that it is possible to fabricate a smart meter that has equal or better performance compared to existing instruments and does not require a separate power source or display, and it is expected to be a reference for the development of various smart instruments in the future.

A Research on transmission energy and data using induced electromotive force of coil (코일의 유도기전력을 이용한 에너지 및 데이터 전송방법에 관한 연구)

  • Jung, Hee-Chur;Seo, Jung-Hwa;Kim, Kyoung-Rok;Kim, Myung-Hyun;Koo, Ja-Chun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.607-615
    • /
    • 2016
  • This study concerns the transmission of energy and data using induced electromotive force. Due to the requirements of weapon systems, most arms are kept in an armory for a very long time before being used. During this time, the reserve battery, which serves mostly as a power supply for the electronic fuze, can be degraded, thus causing problems when it is actually needed. We attempt to solve the various problems associated with the old fuze system caused by long-term storage by using the 'induction power' transmitted from another device just before its operation, instead of using 'built-in power'. We tried to find the best carrier frequency to communicate with the system by induced electromotive force. Also, we changed the communication method for transmitting the 'induction power' from 'FM/AM modulation' to 'Duty ratio modulation', which can transmit a large amount of data in a short time. Through experiments, it was demonstrated that the induction coil can replace the reserve fuze's battery without any problem, thus confirming the possibility of using an induction coil as the power supply source of the electronic fuze.

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

Power Quality Monitoring System of Using Power Line Communication (전력선통신을 이용한 전력품질 모니터링 시스템)

  • Hong Ducpyo;Choi Jaeho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.91-97
    • /
    • 2005
  • As the developing of industry, the nonlinear equipments as inverter, converter, SMPS(Switching Mode Power Supply) and motor have been increased. But the sensitive electronic loads to the power quality, such as computers and other electronic equipments, have been spreaded out very fast. Thus, the power quality(PQ) problems and the real time power quality monitering(PQM) are one of the important issues in industry and building area for the intelligent control of the systems. One of them, PQM using PLC(Power Line Communication) have good merits that can send and receive the PQ information without any new network line. This paper presents the PQM hardware and software to monitor the PQ information by using PLC that meets the categories of IEEE Std. 1159.

Analysis of the Actuator Winding to a Frequency Characteristic based on Energy Conversion Theory (에너지 변환 이론에 의한 액추에이터 권선부의 주파수 특성 해석에 관한 연구)

  • 김양호;이해경;황석영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.83-87
    • /
    • 2004
  • In this paper, an electrical equivalent circuit is derived by solving system equations. A frequency characteristics graph is calculated and the characteristics curve of the linear Actuator Model System are simulated by the Matlab program The frequency characteristics of a linear actuator are analyzed on the structure of the linear Actuator Model System This paper proposed and analyzed the linear Actuator Model(LAM) by using Matlab program with linear actuator was verified computer simulation based on the energy conversion theory.

Development of Ubiquitous Telemetry Water Reading System Using RF and CDMA (RF와 CDMA를 활용한 상수도 원격검침시스템 개발)

  • Lho, Tae-Jung;Kim, Hwa-Il;Lee, Wook-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.215-221
    • /
    • 2009
  • In recent, there has been progressed in various ways of research and development about a ubiquitous telemetry reading, but several problems are arising the reliability of reading value, power supply and so on. These issues were solved by using the RF module and digital pulse meter with photocoupler. Realized by this study, a telemetry reading system, utilizing RF and CDMA telecommunication, and check in real time the state of water leakage by managing the distinct usage data. In addition, the users can check it in person, and it can minimize the public enmities. Further, as a part of the silver industry fur constantly growing senior population, it might be introduced as safety supervision system.

Regenerative Inverter System for DC Traction Substation with Voltage Drop Compensation Mode (전압강하 보상모드를 갖는 직류 지하철용 회생인버터 시스템)

  • Kim, Jun-Gu;Kim, Jae-Hyung;Cho, Kee-Hyun;Won, Chung-Yuen;Kim, Yong-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.213-220
    • /
    • 2008
  • In this paper, the regenerative inverter system with voltage drop compensation mode is proposed. When the main rectifier is broken, the DC traction can not be supplied the power from the utility. Actually, the reserve rectifier is mounted in the substation to prevent this accident. In this paper, the voltage drop compensation mode is added to the regenerative inverter system in order to substitute the reserve rectifier. The proposed regenerative inverter system returns the regenerative energy from the DC line voltage to the utility. In addition, the inverter can be compensate the harmonics caused by the power conversion devices used in the DC traction system. We demonstrated the effectiveness of the proposed control algorithm by using computer simulation.

Performance Analysis of Emergency Communication System of Nuclear Power Plant using Markov Model (마코프 모델을 이용한 원전 비상 통신 시스템 성능 분석)

  • Son, Kwang Seop
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.10-21
    • /
    • 2014
  • In Fukushima accident, when the severe accident such as a natural disaster happens, it is impossible to monitor the plant status due to a extreme environment and station blackout and most I&C systems break downs. Finally, these cause the loss of emergency cooling function and thus results in a hydrogen explosion and radiation leak. In this paper, the emergency response system is introduced that monitors and controls properly when the sever accidents like Fukushima accident happen, And the performance requirements of a wireless communication system used in the emergency respons system is described and the performance of emergency communication system is analyzed using the markov model.