• Title/Summary/Keyword: 전열특성

Search Result 338, Processing Time 0.023 seconds

Performance and Heat transfer Characteristics of Louver Fin-tube Heat Exchanger for Simultaneous Cooling/Heating Heat Pump (동시 냉난방 히트펌프용 루버핀-관 열교환기 성능 및 전열특성 실험연구)

  • Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1337-1342
    • /
    • 2007
  • An experimental study has been performed to investigate the performance and heat transfer characteristics of the heat exchanger for simultaneous cooling/heating heat pump. The heat transfer performance was measured using an air-enthalpy calorimeter and a constant temperature water bath, to obtain the performance evaluation and analysis of a fined tube heat exchanger. Six finned tube heat exchangers with louver fin were tested under a heating condition. Air-side heat transfer and friction were presented in terms of j-factor and f-factor. The heat transfer coefficient increased with decreasing the fin pitch, j-factor and f-factor on the fin pitch and the number of tube rows decreased with increasing Reair.

  • PDF

Signal Characteristics of Eddy Current Test for Intergranular Attack of Steam Generator Tubes (증기발생기 전열관의 입계부식에 대한 와전류검사 신호특성)

  • Choi, Myung-Sik;Lee, Deok-Hyun;Cho, Se-Gon;Yim, Chang-Jae;Han, Jung-Ho;Hur, Do-Haeng
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.198-202
    • /
    • 2002
  • Beacuse intergranular attack (IGA), one of the locallized corrosion forms occurring on steam generator tubes, can not be fabricated by an electric discharge machining method, there are few data for the eddy current test (ECT) characteristics of IGA. In this paper, the characteristics of eddy current signals are evaluated using nonexpanded tubes with IGA defects formed in 0.1 M sodium tetrathionate solution at $40^{\circ}C$. The detectability and sizing accuracy of IGA were discussed in terms of the coil type and frequency of the ECT probes.

Numerical Study on the Effect of Guide Vane Position and Angle on Heat Transfer and Flow Characteristics of a Pin-fin Channel with a Guide Vane (가이드 베인을 부착한 핀-휜 유동에서 가이드 베인 위치와 입사각에 따른 전열 및 유동 특성에 관한 수치적 연구)

  • Lee, Deukho;Oh, Yeongtaek;Bae, Jihwan;Lee, Changhyeong;Kim, Kuisoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.3
    • /
    • pp.35-43
    • /
    • 2019
  • In this study, a guide vane with varying positions and incidence angles was adopted to a pin-fin channel to analyze the change in thermal performance and pressure loss characteristics. A numerical analysis was conducted to investigate the effect of incidence angles and positions on heat transfer and flow characteristics at Re =1400. The results of it were compared those of a pin-fin channel without a guide vane. In case 1 when the incidence angle is $0^{\circ}$, the heat transfer performance is maximized and improved by approximately 5% when compared to the pin-fin channel without the guide vane. In case 2 when the incidence angle is $10^{\circ}$, the pressure loss is minimized and decreased by approximately 1.9% when compared to the pin-fin channel without the guide vane.

An Experimental Study on the Augmentation of Heat Transfer by Impinging Air Jets with Swirl (충돌선회분류(衝突旋回噴流) 열전달증진(熱傳達增進)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Ohu, Su-Cheol;Park, Sung-Soo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 1993
  • This Paper deals with the experimental study of the axisymmetric air jet impinging vertically on the flat heating surface with and without swirl. The purpose of this study is to investigate the characteristics of flow, augmentation of heat transfer rate, turbulent intensity, and the comparison of heat transfer rate, the optimal swirling condition about the swirl and nonswirl axisymmetric air jet. In order to augment the heat transfer on the flat heating surface without introducing any additional power, the technique used in the present work was placement of twisted tape inserted pipe in front of the nozzle exit in order to make a swirl. The effect of swirl degree is investigated in case of S=0., 0.056, 0.111, 0.222 and the velocity of the jet was 14, 20, 26, 32, 38, 44m/s. The distance between the nozle exit and the stagnation point on the impinging plate was the H/D=$1{\sim}14$. In order to analyze of the flow structure which increase heat transfer, the velocity and the turbulent intensity of the axisymmetric jet was measured by a hot wire anemometer according to the swirl number and H/D.

  • PDF

An Experimental Study on the Fluidization and Heat Transfer Characteristics in the Gas-Solid Fluidized Bed Furnace (기일고(氣一固) 유동층노내(流動層爐內) 유동화(流動化) 및 전열특성(傳熱特性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Choi, Gug-Gwang;Park, Jong-Suen
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.55-63
    • /
    • 1989
  • In this paper, the fluidization characteristics of the magnesia fluidized bed and the heat transfer characteristics with the specimen (SM55C) plunged in the bed have been investigated. To characterize the fluidization, the minimum fluidizing velocities and the relation ships between bed voidage and fluidization rate and obtained. To characterize heat transfer, the experiments for finding heating time transfer effect have been carried out by varying the magnesia particles sizes. optimum heating condition in the magnesia fluidized bed is obtained.

  • PDF

증기발생기 sleeve를 위한 Inconel 전열관의 레이저 용접특성분석

  • 권성옥;정진만;김철중
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.956-960
    • /
    • 1995
  • 원자력발전소 증기발생기 전열관의 레이저 보수용접 기술개발을 위해 Inconel tube의 sleeve 레이저 용접실험을 수행하였다. Nd:YAG 레이저로부터 발진된 레이저 빔은 광섬유를 통하여 전송되어 자체 개발한 weld head tool을 이용하여 tube 내부에서 용접이 이뤄지도록 하였다. 레이저의 출력 및 펄스폭, 반복율, buffer 가스속도, 용접속도 등의 용접 변수를 변화시키면서 용접단면의 형상을 측정하였다. 용접변수에 따른 결과를 고찰하였고 이에 따른 적절한 용접범위를 제시하였다.

  • PDF

Characteristics of Heat Transfer for Small-size Marine Diesel Engine (소형박용 디젤엔진의 전열특성)

  • 최준섭
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.36-42
    • /
    • 1996
  • Analysis of heat transfer on small-size Diesel engine is required for the development of high performance and efficiency engine. This basic study aims to establish heat transfer technique for marine Diesel engine. The main results from this study are as follows : 1) Overall engine heat transfer correlation of Re-Nu. 2) Radiant heat flux as fraction of total heat flux over the load range of several different Diesel engine. 3) Characteristics of heating curves on piston, cylinder liner and head. 4) Surface heat flux versus injection timing.

  • PDF

몰비지수에 의한 증기발생기 틈새수화학 특성평가

  • 나정원;성기운;조영현;김우철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.369-373
    • /
    • 1998
  • 증기발생기에서 부식에 의한 전열관 손상은 전열관과 관판사이의 틈새에서 대부분 발생되고 이 틈새에서의 수질환경에 좌우된다. 틈새에서는 과열도가 높아 미량의 불순물이 농축되면서 틈새수화학 (crevice chemistry)은 증기발생기 내부수 수화학과는 달라진다. 전열관 손상을 억제하기 위해서는 틈새수질을 적절히 제어하여야 하는데 이는 틈새수화학을 정확히 분석평가할 수 있는 기술을 기반으로 하여야 한다. .기존의 틈새수질을 계산하는 방법으로는 증기발생기 내부수에 비해 틈새에서 화학종들이 얼마나 농축되는지를 가정하는 농축도 (concentration factor) 방법이 있으나 가정에 의한 불확실성으로 인해 틈새수질을 정확히 해석할 수 없었다. 그러나 원전 증기발생기의 잠복불순물 방출시험 자료로부터 틈새수질을 보다 정확히 평가할 수 있는 새로운 개념의 몰비지수(molar ratio index) 방법이 최근 EPRI에서 제시되었고 EPRI 산하의 많은 발전소에서 적용중이다. 본 연구에서는 PWR 원전 증기발생기의 틈새수화학을 평가할 수 있는 기술을 개발하기 위해 잠복불순물 방출시험 자료로부터 틈새에서의 몰비지수를 계산할 수 있는 CRAP (CRevice-chemistry Analysis Program) 전산프로그램을 작성하였다 CRAP를 국내원전에 적용하여 증기발생기 및 그 틈새에서의 수화학을 평가하였다.

  • PDF

Heat Transfer and Sterilization Characteristics of an ERV Element Made of Hwang-to Paper (황토지로 제작된 전열교환소자의 전열특성 및 항균특성에 관한 연구)

  • Cho, Min-Chul;Oh, Sai-Kee;Ahn, Young-Chull
    • Journal of Power System Engineering
    • /
    • v.21 no.1
    • /
    • pp.50-56
    • /
    • 2017
  • To increase the enthalpy exchange efficiency of ERV elements, the moisture exchange character must be improved. The moisture exchange efficiency depends on material characteristics. The material used for ERV is Hwang-to paper based on Han-ji which is Korean traditional paper. The paper has excellent performance in moisture exchange and heat transfer compared with polymer and other papers. To have an anti bacteria performance and to improve moisture exchange performance of Han-ji, Hwang-to is added to the Han-ji. The enthalpy exchange efficiency of the Hwang-to paper shows 5% greater than that of the conventional paper. In case of Escherichia Coli, the reduction rate of bacteria is 96.6% and in case of Pseudomonas, the reduction rate of bacteria is 97.5%. The ERV element made of Hwang-to paper has a great possibility as an ERV element.

Experimental study on the characteristics of heat transfer for new type aluminum tube (신형 알루미늄관의 열전달 특성에 관한 실험적 연구)

  • 문춘근;윤정인;김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.31-37
    • /
    • 2000
  • This study investigated heat transfer characteristics of refrigeration system using new type aluminium heat transfer tube for evaporator of refrigeration and air-conditioning comparing with bare tube. From the result of heat transfer experiment form one phase flow using cooled and hot water, about 20% heat transfer performance is superior in case of same quantity of flow and about 4% heat transfer performance if superior in case of same velocity comparing with bare tube. Casing of two phase flow, heat transfer performance of new type aluminum heat transfer tube shows about 50% superior heat transfer performance comparing with bare tube in the same evaporating pressure when using heat transfer tube as evaporator and shows about 47% increase when expressing performance coefficient as the rate of refrigerating capacity and compressing work. However, it can be known that pressure drop in the heat transfer tube is taken higher value of about 18% in case of new type aluminum heat transfer tube. From the above result, new type aluminum heat transfer tube is excellent comparing with bare heat transfer tube using the existing heat exchanger for refrigerator.

  • PDF