• Title/Summary/Keyword: 전압상승

Search Result 509, Processing Time 0.03 seconds

Electric Fan Heater Design for Eco-Energy Saving (친환경 에너지 절감형 전기온풍기 기구설계)

  • Sul, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • As the Eco-energy is recently required, electrical energy is fast increased. Several induction heating methods are attractive for Eco-energy and energy saving. In this paper, electrical fan heater was designed and developed with new concept for energy saving by electromagnetic induction heating. Proposed system was composed of three module, blast part, induction heating part and power transformation part. Induction heating method was adapted for heating and the resonant inverter was used for increasing of the power transformation efficiency. Full-bridge resonant inverter was adopted to resonant inverter. This system was composed of induction heating part made with metal(SUS 40 series), and power transformation part made with rectifier module, filter module and resonant inverter. From these results, the proposed new electric heater could be saved the energy from faster increasing the temperature compared to commercial gas and other electric heater. This electrical fan heater is possible to be used in field of home, commercial and agricultural area for eco-energy saving heater.

Gibbsite 상전이에 관한 전자빔 조사효과의 EF-TEM을 이용한 정량화

  • 김영민;정종만;이수정;김윤중
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2003.05a
    • /
    • pp.11-11
    • /
    • 2003
  • 전자현미경내에서 일부 무기 및 금속 시료들은 전자빔 조사에 의해 시료구조가 손상되거나 비정질화 또는 상전이 등과 같은 구조전이 현상들을 겪게 된다. 즉, 전자빔 조사에 의해 시료는 원자간 결합이 끊어져 나타나는 Knock-on damage, 시료 원자 주위의 전자들과의 상호 작용에 의해 나타나는 Ionization damage, 빔 에너지의 시료온도 상승 기여에 의한 Radiolysis damage 등의 현상들을 경험하게 된다. 이러한 현상은 전자현미경의 가속전압, 전자밀도, 시료 조건 등에 따라 그 지배기구가 다르며 동일한 시편이라도 시료의 두께와 시편온도를 결정하는 전자빔 조사선량에 따라 그 양상과 전이 속도가 달라진다. 본 연구에서는 전자빔 조사에 의해 구조 전이를 겪게 되는 대표적 무기수화물의 하나인 Cibbsite에 대해 전자빔 조사효과에 대한 정량적 고찰을 에너지 여과 투과전자현미경 (EF-TEM)을 이용하여 시도하였다. 전자빔 조사는 120분까지 실시하였고 각 시간별로 에너지 필터와 Imaging plate를 이용하여 Gibbsite의 회절패턴과 미세조직 변화를 기록하였다 빔조사 시엔 illumination angle을 1.25mrad(Dose rate : 334 × 10³ e/sup -//sec·n㎡)으로 하였으며 사진기록 시엔 최소 illumination angle인 0.04mrad(Dose rate : 413 e/sup -//sec·n㎡)을 사용하였다. 시료의 관찰방향은 [001]방향이고 관찰시료두께는 약 50nm로 평가되었으며 시료의 화학변화는 EDS를 이용하여 분석하였다. 회절자료의 Intensity는 ELD/CRISP 프로그램을 이용하였으며 빔조사선량은 평행조사빔이 시료와 상호 작용하는 면적과 상호작용하지 않을 때의 빔을 회절모드에서 faraday cup으로 측정한 빔전류로 부터 계산하였다. Gibbsite에 대한 전자빔 조사 시 1분 이내에 급격한 Hydroxyl Ion(OH-)의 이탈로 인해 Cibbsite의 구조는 거시적 비정질화가 되며 시간증가에 따라 χ-alumina → ν-alumina → σ-alumina or δ-alumina의 순으로 상전이를 겪는다. 전자빔 조사 시 관찰된 회절자료의 가시적 변화를 통해 illumination angle 1.25mrad(Dose rate : 334 × 10³ e/sup -//sec·n㎡)일 경우 약 3초 이내에 비정질화가 시작됨을 알 수 있었고 이는 약 1 × 10/sup 6/ e/sup -//sec·n㎡ 의 전자선량에 해당되며 이를 기준으로 각각의 illumination angle에 대한 임계전자선량을 평가할 수 있었다. 실질적으로 Cibbsite와 같은 무기수화물의 직접가열실험 시 전자빔 조사에 의해 야기되는 상전이 영향을 배제하고 실험을 수행하려면 illumination angle 0.2mrad (Dose rate : 8000 e/sup -//sec·n㎡)이하로 관찰하고 기록되어야 함을 본 자료로부터 알 수 있었다.

  • PDF

Negative Resistance Characteristics of $Fe_{1+x}V_{2-x}O_4$ Spinels ($Fe_{1+x}V_{2-x}O_4$ Spinel의 부성저항특성)

  • Lee, Gil-Sik;Son, Byeong-Gi;Lee, Jong-Deok
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.14 no.3
    • /
    • pp.25-31
    • /
    • 1977
  • Fe V spinels were prepared by sintering the well-ground stoichiometric mixtures of Fe O and V O at 1,10$0^{\circ}C$ under H -CO atmosphere. The activation energy for electrical conduction decreases with increasing amount of iron. The tendency of activation energy depending on the amount of iron contained clarifies that the electrical condction of the spinel is mainly due to electron hopping between Fe and Fe ions at B sites. In the experiment for negative resistance characteristics, the threshold voltage (Vth) for the samples is related to ambient temperature, thickness and raising rate of applied voltage. Vth decreases as temperature increases while Vth increases linearly with thickness and Vth increases linearly with the raising rate of applied voltage in semi-logarithmic scale. These results lead to a conclusion that current paths mainly formed by thermal breakdown are ascribed to the negative resistance phenomena. Applying this property, these vanadium iron spinels may be used for switching elements.

  • PDF

Parameters of the Electric and Magnetic Fields Due to Cloud-to-Ground Lightnings (낙뢰에 의한 전계와 자계 파형의 파라미터)

  • 이복희;안창환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.3
    • /
    • pp.359-368
    • /
    • 1998
  • One of the topics concerning the electromagnetic compatibility of modern electronic circuits is to take protection from transient overvoltages caused by not only cloud-to-ground lightnings but also induced lightning discharges. In this paper, the vertical electric and horizontal magnetic fields from cloud-to-ground lightnings were measured and analyzed. The electric and magnetic fields waveforms associated with cloud-to-ground lightnings have several subsidiary peaks which decrease with time. There were not much differences between the electric and magnetic field due to long distance cloud-to-ground discharges. Average values of 10~90% rise times of electric fields are $4.65mutextrm{s}$ for the positive cloud-to-ground lightning and $3.29mutextrm{s}$ for the negative cloud-to-ground lightning, respectively. Also, in the positive and negative cloud-to-ground lightning discharges, the zero-to-zero crossing times in the wave tail of magnetic fields are significantly longer than those of the electric fields.

  • PDF

Impulse breakdown Characteristics in SF6/N2, Gas Mixtures with a Temperature Variation (온도변화에 따른 SF6/N2 혼합가스의 임펄스 절연파괴특성)

  • Li, Feng;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.79-86
    • /
    • 2008
  • This paper presents the experimental results of impulse breakdown characteristics in $SF_6/N_2$ gas mixtures under a highly non-uniform electric field with a change in temperature. The test temperature ranges from -25[$^{\circ}C$] to 25[$^{\circ}C$]. The processes of impulse preliminary breakdown developments were analyzed by the measurements of current pulse and luminous signals. As a result, the temperature dependance of breakdown voltage for the negative polarity was much stronger than that for the positive polarity. When increasing the temperature, The leader stepping time for the negative polarity was shown to be longer than that for the positive polarity. The results presented in this paper can be used as a useful information in designing the gas insulation lines with prominent ability for lightning surge.

Analysis of Thermal Recovery Characteristics for $SF^6$ Gas-Blast Arc within Laval Nozzle (Laval Nozzle에 대한 $SF^6$ 아크의 열적회복특성 해석)

  • Song, Gi-Dong;Lee, Byeong-Yun;Gyeong-Yeop;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.9
    • /
    • pp.522-529
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the thermal recovery characteristics of a Laval nozzle. A commercial CFD program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of GE Co.(General Electric Company). In order to investigate the state of the arc region after current zero, the simulation was carried out with three steps. They are steady state arc simulation, transient arc simulation before current zero, and transient hot-gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl's mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The post-arc current was calculated to evaluate the thermal recovery characteristics after current zero. Compared with the results obtained by GE Co., it has been found that the critical RRRV(ratio of rise of recovery voltage) will be determined previously by this study.his study.

A Study of Ozone Generation Characteristic using Ceramic Catalyst Tube of Ti-Si-Al (Ti-Si-Al형 세라믹 촉매 방전관의 오존 발생 특성 연구)

  • 조국희;김영배;이동훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.130-136
    • /
    • 2002
  • A novel ozonizer has been developed using a high frequency surface discharge and a high purity Ti-Si-Al ceramic catalyst as its dielectric component. A cylindrical thin compound ceramic catalyst in reactor is adhered to inside of the film-like outside electrode. And, when experiment condition are oxygen gas temperature of 20 [$^{\circ}C$], inner reactor pressure of 1.6 atm 600[Hz] and flow late of 2[l/min]. the ozonizer can easily produce ozone concentration(50~60[g/㎥]for oxygen) and power efficiency(180[g/kWh]for oxygen) without using a special enrichment means. At 2[l/min], 20[$^{\circ}C$], 1.6[atm], 600[Hz]and 40[W], the result of simulation to gas temperature of reactor using general code Phoenics, the maximum temperature of reactor was 132[$^{\circ}C$]in reactor. Ant the result electric field simulation of Ti-Si-Al type reactor using general code Flux 2D, maximum electric field was 0.131E.08[V/m].

Current Limiting Characteristics due to Application Location of a Superconducting Fault Current Limiter in a Simulated Power Distribution System (모의배전계통에 초전도한류기의 도입위치에 따른 전류제한 특성)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.90-95
    • /
    • 2009
  • The application of a large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer‘s impedance causes the short-circuit current of the power distribution system to increase and thus, the higher short-circuit current exceeds the cut-off ratings of the protective devices such as a circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from the higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. However, the current limiting effect of SFCL including its bus voltage drop compensation depends on SFCL's application location in a distributed power system. In this paper, the current limiting and the bus-voltage drop compensating characteristics of the SFCL applied into a power distribution system were studied. In addition, the quench and the recovery characteristics of the SFCLs in each location of the power distribution system were compared each other.

A Thermoprofile Study of 2,450-MHz Microwave Thermogenerator in Phantom and Animal Tumor (2,450 MHz 온열치료기의 온도분포실험 -Phantom 및 실험동물종양에서-)

  • Yoon S. C.;Gil H. J.;Bahk Y. W.;Chu S. S.
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.173-177
    • /
    • 1986
  • Since March 1985, we have treated cancer patients with local hyperthermia using a 2,450-MHz microwave thermogenerator. Prior to clinical trial, a 2,450-MHz microwave generator remodeled from a household electric range was tested and evaluated to test its clinical applicability. We studied the thermoprofile and tried to find out suitable electric power ranges to produce optimal temperature of $42-44^{\circ}C$ in a lump of meat, agar phantom and animal tumor models. The present study confirmed the intratumoral temperature to be $1-3^{\circ}C$ higher than in surrounding normal tissue.

  • PDF

결정질 실리콘 태양전지 표면 조직화 형상이 효율에 미치는 영향 분석

  • Byeon, Seong-Gyun;Kim, Jun-Hui;Park, Ju-Eok;Jo, Hae-Seong;Kim, Min-Yeong;Im, Dong-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.315.1-315.1
    • /
    • 2013
  • 표면 조직화의 목적은 태양전지 표면에서의 입사되는 빛의 반사율을 감소 시키고, 웨이퍼 내에서 빛의 통과 길이를 길게 하며, 흡수되는 빛의 양을 증가시키는 것이다. 본 연구에는 습식, 건식 표면조직화 방법에 따른 표면 형상과 표면 반사도를 분석 하였으며, 셀을 제작하여 전기적 특성과 광학적 특성의 상관관계를 분석하였다. 표면 조직화 공정은 염기성 용액인 KOH를 이용한 식각 방법과 Ag를 이용한 metal-assisted 식각, 산증기를 이용한 식각, 플라즈마를 이용한 반응성 이온식각을 적용하여 제작하였다. 표면 반사율을 400~1000 nm 사이의 파장에서 측정하였으며 KOH를 이용하여 식각한 샘플이 9.11%의 표면 반사율을 가졌으며 KOH를 이용하여 식각한 표면에 추가로 metal-assisted 식각을 한 샘플이 2%로 가장 낮은 표면 반사율을 보였다. 표면 조직화 후 동일 조건으로 셀을 제작 하여 효율 측정 결과 Ag를 이용한 2단계 metal-assisted chemical 식각이 15.83%의 가장 낮은 광변환 효율을 보였으며 RIE를 이용한 2단계 반응성 이온 식각공정이 17.78%로 가장 높은 광변환 효율을 보였다. 이 결과는 반사도 결과와 일치 하지 않았다. 표면 조직화 모양에 따른 셀 효율의 변화는 도핑 프로파일과 표면 재결합 속도의 변화 때문이라 생각되며 더 명확한 분석을 위해 양자 효율을 측정하여 분석을 시도하였다. 측정 결과 단파장 대역에서 낮은 응답특성을 가지는 것을 확인 할 수 있었는데 그 이유는 낮은 반사도를 가지는 표면조직화 공정의 경우 나노사이즈의 구조를 갖기 때문에 균일한 도핑 프로파일을 얻지 못해 전자 정공의 분리가 제대로 이루어지지 못하였고 표면 재결합 속도증가의 원인으로 단락전류와 개방전압이 낮아져 효율이 떨어진 것으로 판단된다. 실험 결과 도핑 프로파일의 균일성은 셀 효율 개선을 위해 낮은 표면 반사율 만큼 중요하다는 점을 알게되었다. 낮은 반사율을 갖는 표면조직화 공정도 중요하지만 표면에 따른 균일한 도핑 프로파일을 갖는 공정을 개발한다면 단파장 응답도가 향상되어 단락전류밀도의 상승효과를 얻을 수 있을 것이라 판단된다.

  • PDF