• Title/Summary/Keyword: 전선강도

Search Result 75, Processing Time 0.034 seconds

ASummer Circulation Inferred from the Density (Temperature) Distribution in the Eastern Yellow Sea (密度(水溫) 分布에 의한 夏季黃海東部의 海水循環考察)

  • 성영호
    • 한국해양학회지
    • /
    • v.22 no.2
    • /
    • pp.63-70
    • /
    • 1987
  • Existing oceanographic data indicate that tidal mixing fronts generally prevail in the Eastern Yellow Sea along the Korean coast. In the Western part, these fronts seem to be much weaker. These fronts are believed to be generated mostly by spatially different tidal mixing. The geostrophic adjustment model applied to the observed density structure gives the mixed coastal water flowing northward and the offshore waters(both surface warm and bottom cold waters) flowing southward along the Korean coast. The transport of each water amounts to O(10$\^$4/)m$\^$3//sec.

  • PDF

The Sag Behavior of STACIR/AW $410mm^2$ Power Line (STACIR/AW $410mm^2$ 송전선의 이도거동)

  • Park, Su-Dong;Kim, Byung-Geol;Kim, Shang-Shu;Lee, Hee-Woong;Jang, Tae-In;Kang, Ji-Won;Lee, Dong-Il;Min, Byung-Uk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1262-1265
    • /
    • 2004
  • 송전용량 증가를 위해 개발되어 최근 본격적으로 사용되고 있는 STACIR/AW 송전선은 송전용량의 증가에 따라 그 운전환경도 변화하여 연속사용온도의 경우, 기존 ACSR 전선의 90t에 비해 높은 $210^{\circ}C$로 규정 되어 있을 만큼 고온에서 운전되고 있다. 따라서 STACIR/AW 송전선은 이도설계와 그 운용에 있어서 운전 온도 상승에 따른 각별한 주의관리가 필요하다 실제 STACIR/AW송전선은 그 설계단계에서도 이와 같은 고온운전 환경을 고려하여 고온에서도 소정강도를 유지하는 내열 Al도체와 이도제어를 위한 낮은 열팽창 특성의 INVAR합금(Fe-35Ni계 합금)을 강선으로 하는 특화된 재료로 구성되어 있다. 그러나 이와 같은 재료 설계적 보완책에도 불구하고 실제 송전선은 전선의 자중, 철탑 간에 형성된 가설장력과 같은 다양한 응력이 고온환경에서 부하되는 복합 열화 상태에 노출되어 있고, 이것은 재료학적인 관점에서 크릴 변형 발생의 가능성을 높이고 있으나 이것에 대한 연구 또는 실험결과는 크게 미미한 실정이다. 본 연구에서는 STACIR/AW $410mm^2$ 송전선과 그 구성소재를 대상으로 $200^{\circ}C$, $300^{\circ}C$에서 장시간 열화한 후, 구성소재의 탄성계수, 열팽창계수 및 STACIR/AW전선의 크림변형 거동을 조사하여 열화에 노출된 STACIR/AW 송전선의 이도변화 거동을 규명하고자 하였다.

  • PDF

Development of overhead distribution line diagnosis system program (가공 배전선로 진단시스템 프로그램 개발)

  • Dong Hyun Chung;Deok Jin Lee
    • Smart Media Journal
    • /
    • v.12 no.5
    • /
    • pp.81-87
    • /
    • 2023
  • In this paper, accidents in high-voltage overhead distribution lines, which provide stable power supply in the power system, cause inconvenience in life and disruption of production of companies. 22.9 [kV] high-voltage overhead power distribution lines aim to improve reliability and stability, such as damage caused by rain, snow, wind, etc., or electric shock prevention. Therefore, in order to prevent wire disconnection accidents due to deterioration of electrical conductivity or tensile strength due to corrosion of overhead distribution lines, it is necessary to prevent unexpected accidents in the future through regular inspection and repair. In order to diagnose deterioration due to corrosion of distribution lines, a diagnostic system (measuring instrument) is installed on the wires to monitor the condition of the wires. The manager on the ground receives the measured data through ZigBee wireless communication, controls the diagnosis system through the diagnosis system program, and grasps the condition of the overhead distribution line through the measured data and photographed photos, and predicts the life of the wire along with the visual inspection method. developed a program.

Analysis of Seepage Velocity in Unsaturated Weathered Soils Using Rainfall Infiltration Test (강우침투실험을 통한 불포화 풍화토 지반의 강우 침투속도 분석)

  • Kim, Hoon;Shin, Ho-Sung;Kim, Yun-Tae;Park, Dug-Keun;Min, Tuk-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.71-78
    • /
    • 2012
  • Rainfall infiltration test under one dimensional condition is conducted to evaluate the effect of rainfall intensity on seepage velocity and infiltration characteristics for initial unsaturated sediment. Experimental results are compared with those numerical simulations with respect to variations of pore water pressure, degree of saturation and discharge velocity with time, and both results give good agreement. High rainfall intensity tends to increase seepage velocity almost linearly. But it shows rapid increase as rainfall intensity approaches saturated hydraulic conductivity of the sediment. In addition, the upper part of wetting front depth is partially saturated, not fully. Therefore, actual wetting front depth is considered to advance faster than theoretical prediction, which leads to slope instability of unsaturated slope due to surface rainfall.

Characteristics of Insertion Loss of Adhesive Tapes to Reduce Noise through Small Opening Hole (미세한 공혈을 통한 소음의 저감을 위한 접착 테이프 별 삽입손실 특성)

  • Yong Thung Cho
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.232-237
    • /
    • 2024
  • Adhesive tapes can be conveniently used for various applications by combination of materials requiring diverse mechanical strength and specific adhesives. Duct tape is usually readily available and one of the most widely used adhesive tapes. Duct tapes are composite materials with good mechanical strength consisted of fiber material, which is different from other tapes. In addition, electrical insulation tapes are used for very long period of time for insulating cables, and are also used for reinforcement of mechanical strength and increasing damping of cable in practice. Recently, variety of foam tapes and double-sided tapes are widely used in diverse applications. However, there is no previous work readily available clearly illustrating noise isolation performance of tapes. In present work, noise isolation performance of tapes is presented by measurement of insertion loss of variety of tapes on a small hole. Double-side foam tapes presented the best noise isolation performance among adhesive tapes measured in present work.

Influence Factors of Street Environment for Provision and Management of Street Green (가로녹지 조성 및 관리를 위한 가로환경 영향요인 분석 연구 - 서울시 관리도로를 대상으로 -)

  • Han, Bong-Ho;Kwak, Jeong-In;Kim, Hong-Soon
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.2
    • /
    • pp.253-265
    • /
    • 2013
  • This study was correlation analysis between provision and management of street green and street environment through field survey about city official roads(93 routes, 629.2km) in Seoul. Green belt under the street trees were 17.5% of all routes. Composition of street green belt width of 1~ 2m was the most common(11.6%). Management status as a protected facilities were protect frame and prtect cover installed inerval(60.1%). Interval of pruning was 63.5%. Type of tree was mainly 47.9%. Road width was mainly more than 8-line(51.3%). Sidewalk width was mainly 3~6m(84.1%)in environment status of street. Landuse was mainly commercial and business(70.3%). Electronic wire complete was mainly compete with crown(33.6%). Use of sidewalk was mainly used(16.3%). ANOVA analysis was conducted between the Street green and environment of Street. Street green belt(more than with 3m) was analyzed to be effective in street green manufacture. Natural green area of city's outside and Industrial area were analyzed to be effective. Use of sidewalk was to be a management. Protection facilities are installed on the narrow sidewalk width lower intensity. There was a higher strength in narrow sidewalk width, road width and compete with crown. And type of tree was higher strength similarly. Pruning and type of tree showd a significant correlation. Thus, ensure sufficient sidewalk width and land use should be considered for street green was effective manufacture and management. Species selection and pruning management was needed by consider electronic wire management, type of tree and landscape.

Mechanical Deterioration Characteristics of ACSR due to a Flame (화염으로 인한 ACSR의 기계적 열화 특성)

  • 박창기;이광식;강지원;김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.160-168
    • /
    • 2003
  • In Korea, a large portion of aerial power-transmission cables is installed in the mountains. In the case of a fire in the mountains, steel wires coated with zinc and aluminum wires of those power cables exposed to the fire or near around will be deteriorated by the blaze and the high temperature. Deterioration proceeds by interactions of a variety of factors like quality, manufacturing process, the condition of installation and exposure environment of a wire, and so on. Generally, the characteristic of a conductor affect by a forest fire can not be analyzed without the effect through simulating a forest fire. However, there are little research accomplishments of that kind of simulation about it, and there's been no analysis of a sample exposed to an actual forest fire. This thesis shows the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include the intensity of extension and wrench for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR 480[$\textrm{mm}^2$] which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

Bonding Stress Analysis of Cable Fairings used in Small Guided Missiles and Strength Tests of Bonding Materials (유도무기 케이블 페어링의 강도 해석 및 접착재 강도 시험)

  • Goo, N.-S.;Yoo, K.-J.;Shin, Y.-S.;Lee, Y.-H.;Cheong, H.-Y.;Kim, B.-H.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.76-82
    • /
    • 2005
  • Cable fairings of guided missiles are generally used for protection of electric cables under aerodynamic heating and mechanical loading. The stress distributions between a cable fairing and missile main body along a cable fairing are necessary for its design. In this paper, a method for bonding stress and strength analysis of a cable fairing has been investigated and its computer program developed. Tensile and three-point bending tests of generally used bonding materials were also conducted to supply basic material properties for design of cable fairings.

장기 노출된 탄소 콘크리트의 전기적 특성

  • 김종훈;김찬오;손기상
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.05a
    • /
    • pp.77-81
    • /
    • 2002
  • 콘크리트에 탄소를 혼합하여 제작하면 탄소자체의 흡수성질이 있어 배합콘크리트에 밀실하게 배합되기가 쉽지 않으나 일단 밀실하게 제작되면 압축강도가 크게 개선되는 것으로 전기$\cdot$전도에 큰 성능개선을 할 수 있는 것으로 보여진다. 콘크리트에 전선을 매입하여 그 특성을 개선하는 등 해외 및 국내 연구들이 진행되고 있다. 본 연구에서는 기구 매입 없이 초기 배합에서 곧바로 전기적 특성을 이러한 방향으로 개선하는 방법을 찾는 기초연구를 하는데 있다.(중략)

  • PDF

An Experiment on Guy Tensions and Stub Strengths (지선장력 및 수평지선주 강도시험)

  • Wong, Yoon-Chan;Cho, Si-Hyung;Kim, Geun-Hwan;Park, Jung-Shin;Kim, Dae-Hark;Lee, Si-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.5-6
    • /
    • 2006
  • 본 시험의 목적은 수직주 및 $80^{\circ}$경사주에 대한 강도시험을 통하여 보통지선이 없는 수평지선주의 시설가능 범위를 파악하고, 전선장력에 대한 지선장력과 전주저항모멘트간의 상관관계를 실증시험을 통하여 지선 강도계산시 전주저항모멘트 적용의 타당성 여부를 조사하는 것이다. 시험결과 $2^{\circ}$이상 휘어진 전주는 지선 보강이 필요하며, 설계시 하중 작용점에 따른 전주저항모멘트는 일정한 값을 적용하여도 됨을 확인하였다. 그리고 지선강도계산식에서 전주의 저항모멘트를 고려하지 않는 것이, Y지선보다는 각 하중 작용점에 해당 불평균장력에 견디는 1조 지선을 시설하는 것이 바람직하다. 또한 보통지선이 없는 수평지선주는 지선에 작용하는 하중, 전주의 설계하중, 전주길이 및 지선의 설치위치를 고려하여 선정하여야 하여야 함을 도출하였다.

  • PDF