• 제목/요약/키워드: 전산화 단층 혈관 조영술

Search Result 55, Processing Time 0.031 seconds

A Study on Selection of Optimal Imaging Diagnostic Device for Cerebral Angiography: Focusing on MRA, CTA, and DSA Imaging Diagnosis Devices (뇌혈관 검사 시 최적의 영상 진단장치 선정에 관한 연구: MRA, CTA, DSA, 영상 진단장치 중심으로)

  • Byun, Jung-Su;Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.637-645
    • /
    • 2017
  • The objective of this study was to find the optimum test device for the cerebral blood vessels by comparing and analyzing the SNR and CNR methods for images of three devices (i.e., MRA, CTA, and DSA). The study targeted 90 patients who underwent cerebral angiography from November 2016 to May 2017. The measuring parts were measured by using Rt MCA, Lt MCA, and ACA Image J. The results of quantitative analysis showed that the mean SNR of MRA, the CNR of MRA, the signal strength of MRA, the mean SNR of CTA, the CNR of CTA, the signal strength of CTA, the SNR of DSA, the CNR of DSA, and the signal strength of DSA were evaluated as 254.87, 178.13, 326.81, 74.75, 62.2, 356.66, 26.85, 25.89, and 4400.69, respectively (p<0.05). As a result, both SNR and CNR methods measured it in the order of MRA>CTA>DSA. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis SPSS. In conclusion, the results of this study revealed that the optimum imaging devices were MRA, CTA, and DSA after evaluating randomly selected patients with cerebrovascular disease.

Accuracy of Nodal Staging with Integrated PET/CT Scanning in Non-small Cell Lung Cancer (양전자단층촬영/전산화단층촬영(integrated PET/CT)을 이용한 비소세포폐암의 림프절 병기판정)

  • Kim, Ji-Hoon;Chung, Won-Sang;Kim, Young-Hak;Kim, Hyuck;Jeon, Seok-Chol
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.700-704
    • /
    • 2010
  • Background: For staging primary lung cancer, integrated positron emission tomography/computed tomography (PET/CT) imaging is popular. The purpose of this study was to evaluate the accuracy of PET/CT scanning in lymph nodal staging of lung cancer. Material and Method: We studied 48 patients who had received CT, PET/CT and pulmonary resections due to primary non-small cell lung cancer in our hospital between January 2006 and August 2009. Mediastinal lymph nodes were classified as superior mediastinal nodes, aortic nodes, inferior mediastinal nodes, or N1 nodes. We compared the power of CT and PET/CT for diagnosing pulmonary lymph nodes for each of the four types of nodes. Result: PET/CT was more sensitive than CT for all groups except inferior mediastinal nodes. However, the differences were not significant (McNemar's test: superior mediastinal nodes, p=0.109; aortic nodes, p=1.000; inferior mediastinal nodes, p=0.625, N1 nodes, p=0.424). Conclusion: The accuracy of PET/CT is similar to that of CT alone for staging lymph nodes. The two imaging modalities might be used as complementary, cooperative tools. We expect that integrated PET/CT will be found to be significantly mmore sensitive after more trials are done and more data is accumulated.

Popliteal Artery Entrapment Syndrome -One case report - (슬와동맥 포착증후군 - 1예 보고 -)

  • Oh Jae-Yun;Lee Seock-Yeol;Lee Chol-Sae;Lee Seung-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.791-794
    • /
    • 2006
  • Popliteal artery entrapment syndrome is a rare disorder and lead to claudication and disturbance of blood flow from the results of an abnormal relationship of the popliteal artery to the gastrocnemius muscle, a fibrous band or the popliteus muscle in a young male population. The specific diagnosis is difficult, In most cases, surgical treatment provides a definitive diagnosis of the lesion and is necessary for the patient's recovery. A 34-years-old male was admitted complaining of claudication and pain on left leg. Ankle-brachial index, vascular sonography, CT-angiogram and MRI revealed an occlusion of proximal popliteal artery of left leg. The patient was confirmed as a popliteal artery entrapment syndrome (type IV) that the popliteal artery was entrapped by a fibrous band around the popliteus muscle in the operative fold. Completely occluded fibrotic popliteal artery was removed, and interposition with ipsilateral greater saphenous vein graft was done. After surgery, symptoms of the patient have improved.

Surgical Treatment of Lemierre′s Syndrome -A case report- (Lemierre 증후군의 수술 치험 -1례 보고-)

  • 오정훈;이정철;이동협;이장훈;정태은;한승세
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.644-647
    • /
    • 2001
  • Lamierre's syndrome is characterized by a rare fulminant condition resulting from primary oropharyngeal infection followed by secondary septic thrombophlebitis of the internal jugular vein and metastatic infection. A forty-year-old man who had been on ventilator due to servere chest trauma, showed severe reddish inflammatory swelling of the right cervical soft tissue and newly developed pneumonia. He went into in septic condition shortly thereafter. Thrombophlebitis with central abscess in the right internal jugular vein was identified by neck CT and MRA(magnetic resonance angiography). Right cervical swelling worsened in spite of clindamycin and heparin therapy. We performed immediate surgery for removal of septic thrombus and resection of internal jugular vein. Patient's septic condition, pneumonia, and local inflammatory reaction were improved within several days after surgery.

  • PDF

Arterio-Biliary Fistula as a Rare Life-Threatening Complication of Transjugular Intrahepatic Portosystemic Shunt: A Case Report (경경정맥 간내 문맥 정맥 단락술 후 드물게 발생하는 동맥-담관루: 증례 보고)

  • Ji Su Ko;Lyo Min Kwon;Han Myun Kim;Min-Jeong Kim;Hong Il Ha;Ji Won Park;Ji Young Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.705-711
    • /
    • 2022
  • A 46-year-old male with alcoholic liver cirrhosis underwent a transjugular intrahepatic portosystemic shunt (TIPS) for refractory ascites. On the 9th day after the procedure, he presented with melena and decreasing hemoglobin levels. Hemobilia due to fistula formation between the right intrahepatic bile duct and right hepatic artery was suspected on computed tomography. Angiography revealed a fistula of the small branches of the hepatic segmental arteries, and right intrahepatic bile duct was confirmed; embolization was successfully performed with a coil for the eighth segmental hepatic artery, a glue-lipiodol mixture for the fifth segmental hepatic artery, and gelfoam slurry for the right anterior hepatic artery. However, 2 days after embolization, the patient died owing to aggravated disseminated intravascular coagulopathy. When gastrointestinal bleeding occurs after TIPS, careful evaluation is immediately required, and hemobilia should be considered.

Diameters of the Thoracic Aorta Measured with Multidetector Computed Tomography (다중검출 전산화 단층촬영을 이용하여 측정한 흉부대동맥의 직경)

  • Lee, Gun;Lim, Chang-Young;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • Background: Background: Computed tomography (CT) is the main tool for detecting abnormalities of the thoracic aorta, but conventional CT only shows the cross-sectional images. These CT images have some limitations fo accuratly measuring the thoracic aortic diameters at various levels. Multidetector computed tomography (MDCT) overcomes these limitations. We measured the thoracic aortic diameter perpendicular to the loop-shaped thoracic aortic course and this was studied in relation to age, gender, height, weight, the body surface area, the body mass index and the presence of hypertension. Material and Method: Thirty hundred thirty one patients (males: 141 patients and females: 190 patients) who had no abnormalities of the thoracic aorta were investigated using MDCT aortography. They were divided into three age categories: 20~39 years old, 40~59 years old and over age 60. The image was reformed with multiplanar reconstruction and the diameter of the aorta was measured perpendicular to the aortic course at 5 anatomic segments. Level A was the mid-ascending aorta, level B was the distal ascending aorta, level C was the aortic arch, level D was the aortic isthmus and level E was the mid-descending aorta. Result: The mean age was 49.5 years old for males and 54.9 years old for females (p<0.05). The mean diameter of the thoracic aorta at level A was 31.1 mm, that at level B was 30.2 mm, that at level C was 26.5 mm, that at level D was 24.0 mm and that at level E was 22.6 mm. The diameters at all the levels were gradually increased with age. Hypertensive patients had larger diameters than did the non-hypertensive population. There was a positive correlation between the ascending aortic diameter (levels A&B) and height and the body surface area, but there were no statistical differences at the aortic arch (level C) and the descending aorta (levels D&E). There were no statistical differences of the weight and body mass index at all levels. Conclusion: The diameters of the thoracic aortas were directly correlated with gender, age and hypertension. Height and the body surface area were only correlated with the ascending aorta. Weight and the body mass index have no statistical difference at all levels. We measured the age related thoracic aortic diameters and the upper normal limits and we provide this data as reference values for the thoracic aortic diameter in the Korean population.

Giant Cavernous Hemangioma of the Esophagus -One Case Report- (식도에 발생한 거대 해면혈관종 수술치험 - 1례 보고 -)

  • Lee, Chang-Min;Park, Sung-Dal;Cho, Sung-Rae;Huh, Bang
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.324-328
    • /
    • 1998
  • Esophageal hemangioma is an extremely rare benign tumor that causes dysphagia and massive upper gastrointestinal bleeding. Although certain abnormalities seen on a barium swallow esophagography or at endoscopy may suggest an esophageal hemangioma, a contrast CT and radionuclide angiography using a blood-pool radiopharmaceutical can characterize the intense vascularity of the tumor. We experienced the ase of a 7$\times$7$\times$3.5 cm in size giant cavernous hemangioma of the lower 1/3 of esophagus in a 40 year old man. A mural cavernous hemangioma was diagnosed with a barium swallowed esophagogaphy, endoscopy, and a contrast CT. It was treated successfully by transthoracic esophagectomy including the tumor and esophagogastrostomy.

  • PDF

Hybrid Operation of a Kommerell’s Diverticulum with Left Aberrant Subclavian Artery (비정상 좌측 쇄골하동맥을 동반한 Kommerell 게실의 하이브리드 수술법)

  • Kim, Hye-Won;Lee, Jae-Won;Jung, Sung-Ho;Jung, Jae-Seung;Jung, Jong-Pil
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.458-461
    • /
    • 2010
  • A 53-year-old woman had right aortic arch, Kommerell’s diverticulum and aberrant left subclavian artery (LSA) without any compressive symptoms. Hybrid operation was performed. This consisted of LSA bypass using a 6 mm ringed Gore-Tex graft between the left common carotid artery and aberrant LSA via a left supraclavicular incision, and stent graft insertion into the aortic arch via the right femoral artery. Postoperative computed tomography as well as intraoperative angiography demonstrated successful occlusion of Kommerell’s diverticulum and bypass of the aberrant LSA. There were no complications related to the operation or the intervention.

Right Coronary Artery to Left Ventricular Fistula with a Giant Right Coronary Artery Aneurysm - A case report - (거대 우관상 동맥류를 동반한 우관상 동맥에서 좌심실로 유출되는 관상 동맥루 - 1예 보고 -)

  • Kang, Joon-Kyu;Huh, Jae-Hak;Chang, Ji-Min;Song, Cheol-Min
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.296-299
    • /
    • 2010
  • A right coronary artery to left ventricular fistula with a giant right coronary artery aneurysm is a very rare condition. This requires surgical treatment because of the possibility of rupture of aneurysm, heart failure and infective endocarditis. A 47 years old male patient with dyspnea on exertion for 3 months was diagnosed as having a right coronary artery to left ventricular fistula with a giant right coronary artery aneurysm according to the CT and coronary artery angiography. We resected the aneurysm and performed a coronary artery bypass graft.

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.