• 제목/요약/키워드: 전산화 단층촬영장치

Search Result 103, Processing Time 0.026 seconds

Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality (흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가)

  • Kim, Min Kyoung;Kwak, Hyeng Ju;Kim, Jong Hun;Choe, Won-Ho;Ha, Yun Kyung;Lee, So Jung;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.143-147
    • /
    • 2016
  • Recently, digital tomosynthesis system (DTS) has been developed to reduce overlap using conventional X-ray and to overcome high patient dose problem using computed tomography (CT). The purpose of this study was to develop image reconstruction algorithm and to evaluate image characteristics and dose with chest digital tomosynthesis (CDT) system. Image reconstruction was used for filtered back-projection (FBP) methods and system geometry was constructed ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, and ${\pm}30^{\circ}$ angular range for acquiring phantom images. Image characteristics carried out root mean square error (RMSE) and signal difference-to-noise ratio (SDNR), and dose is evaluated effective dose with ${\pm}20^{\circ}$ angular range. According to the results, the phantom image with slice thickness filter has superb RMSE and SDNR, and effective dose was 0.166 mSv. In conclusion, we demonstrated usefulness of developed CDT image reconstruction algorithm and we constructed CDT basic output data with measuring effective dose.

Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning (흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과)

  • Lee, Jong-Seok;Kweon, Dae-Cheol;You, Beong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.225-231
    • /
    • 2009
  • The purpose of the current study was to compare radiation dose of 64MDCT performed with automatic exposure control (AEC) with manual selection fixed tube current. We evaluated the CT scans of phantom of the chest and abdomen using the fixed tube current and AEC technique. Objective image noise shown as the standard deviation of CT value in Hounsfield units was measured on the obtained images. Compared with fixed tube current, AEC resulted in reduction of the chest and abdomen in the CTDIvol (35.2%, 5.9%) and DLP (49.3%, 3.2%). Compared with manually selected fixed tube current, AEC resulted in reduced radiation dose at MDCT study of chest and abdomen.

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound (효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현)

  • 박형재;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.516-519
    • /
    • 2001
  • To diagnose a patient's blood vessel disease, apoplexy, hypertension, arteriosclerosis, the blood velocity is very important. Determining the blood velocity methods using ultrasound are Continuous Doppler System and Pulse Doppler System. In using the Pulse Doppler System, we can obtain the position of blood velocity. But it is more complex hardware than Continuous Doppler System and it has low SNR(signal-noise ratio). So in this study, to obtain a believable information we use the Continuous Pulse Doppler System. Thus system have analog part and digital part. In analog part is composed of ultrasound generating part, the amplifying part to amplify the received signal from ultrasound sensor, the demodulation part to detect blood velocity and the filtering part to remove the noise. In digital part is composed of the A/D conversion part, digital signal processing part, and the communication part to communicate the PC. In this study to implement efficient ultrasound blood velocity measurement system, we can get the patient's blood velocity information in realtime. Thus, It is a useful in the accurate diagnosis with C.T(computered tomography), M.R.I(magnetic resonance imaging).

  • PDF

A study of incisive canal using a cone beam computed tomography (cone beam형 전산화 단층촬영장치를 이용한 절치관의 연구)

  • Kim Gyu-Tae;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.7-12
    • /
    • 2004
  • Purpose: To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. Materials and Methods: 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. Results: The mean length of incisive canal was 15.87 mm±2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm±0.76 and 3.89 mm± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3°±6.96 and 117.45°±7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r= 0.258). Conclusion : This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  • PDF

Anatomical structure of lingual foramen in cone beam computed tomography (Cone beam형 전산화 단층촬영장치를 이용한 설공의 해부학적 구조)

  • Ki Min-Woo;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.129-136
    • /
    • 2004
  • Purpose: To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Materials and Methods : Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. Results: In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03±0.08, and both lateral lingual foramina was 0.20±0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9mm±0.28, right lateral lingual foramen was 0.92mm±0.23, and left lateral lingual foramen was 0.88mm±0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Conclusion : Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  • PDF

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

Effect of conservative therapy and Mandibular condylar bone change on Adolescents with osteoarthritis of TMJ (청소년 측두하악관절 골관절염의 보존적 치료효과 및 관절면의 변화 비교)

  • Jeon, Hye-Mi;Kim, Kyung-Hee;Ok, Soo-Min;Heo, Jun-Young;Jeong, Sung-Hee;Ko, Myung-Yun;Ahn, Young-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.4
    • /
    • pp.357-366
    • /
    • 2013
  • This study is designed to evaluate the treatment outcome of occlusal stabilizing splint and to assess follow-up study of condylar bony changes using cone beam computed tomography(CBCT) in adolescents patients (12-19 years) with TMJ osteoarthritis(OA). 167 eroded condyles in 149 subjects were chosen among the patients who presented to the Department of Oral Medicine of Pasan National University Hospital, diagnosed as TMJ osteoarthritis by clinical exam, x-ray and CBCT from 2009 to 2012. They were treated conservatively with physical therapy, medication, behavioral therapy and occlusal stabilizing splint therapy. After average 9 months, CBCT was retaken and subjective symptoms and clinical findings were investigated. Condyle bony changes were classified by unchanged, less severe and more severe. The obtained results were as follow: 1. Pain, Noise, LOM(Limitation of motion) and MCO(Maximum comfortable opening) measurement of TMJ OA patients were markedly improved after conservative treatment. 2. In the occlusal stabilizing splint therapy group, Pain and LOM were statistically significant improved than non-occlusal stabilizing splint therapy group. 3. In the acute occlusal stabilizing splint therapy group, Pain and LOM were remarkably improved. 4. In comparison of CBCT1 and CBCT2 images, the transition of bone changes to lesser severe was most commonly in joint with erosive change. 5. In the non-occlusal stabilizing splint therapy group, the transition of condylar bone changes from erosion to more severe was many than occlusal stabilizing splint therapy group.

Investigation of Ring Artifact Using Algebraic Reconstruction Technique (대수적 재구성 기법을 통한 링 아티팩트 조사)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.65-70
    • /
    • 2018
  • Computed tomography system is widely used on various fields because section image of an object can be acquired. During several step to obtain section image, artifacts by many error factors can be added on the image. Ring artifact induced by the CT system is examined in this study. A test phantom of $512{\times}512$ size was constructed numerically, and the ring artifact was investigated by the algebraic reconstruction technique. The computer program was realized using Visual C++ under the fan beam geometry with projections of 720 and detector pixel of 1,280. The generation of ring artifact was verified by applying different detection efficiency on detector pixels. The ring intensity became large as increasing the ring value, and the ring artifacts were strongly emphasized near the center of the reconstructed image. The ring artifact may be eliminated by tracking the position of ring artifact on the reconstructed image and by calibrating the detector pixel.