• 제목/요약/키워드: 전산화단층촬영 영상

Search Result 505, Processing Time 0.022 seconds

Examination Techniques and Imaging Findings of Hepatic Hemangioma (간혈관종의 검사기법과 영상소견)

  • Chang-Hoe Koo;Jong-Wan Keum;Ji-Eun Seok;Dong-Chul Choi;Yun-Ho Choi;Man-Seok Han;Min-Cheol Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.375-384
    • /
    • 2023
  • Most Hepatic hemangiomas are asymptomatic and small in size, making them difficult to find by pathological examination. Therefore, radiological diagnosis is essential for the early finding and diagnosis of Hepatic hemangioma. Three-phase method using contrast medium in computed tomography, T1, T2-weighted imaging in magnetic resonance imaging, dynamic magnetic resonance imaging using contrast medium, echo planar imaging method, diffusion-weighted imaging method, blood pool scan using 99mTc-labeled red blood cells in nuclear medicine, we looked at the color doppler method In ultrasound, and it is important to accurately understand the imaging findings of hepatic hemangioma and perform the examination in order to make an accurate diagnosis. most hepatic hemangioma are benign tumors, care should be taken not to confuse them with malignant tumors such as hepatocellular carcinoma to prevent unnecessary procedures. Therefore, in order to make an accurate diagnosis, it is important to accurately understand the imaging findings of hemangioma and perform the examination.

Clinical Course of Small Subepithelial Tumors of the Small Bowel Detected on CT (전산화단층촬영에서 확인된 소장의 작은 상피하종양의 임상 경과 연구)

  • Seohyun Kim;Seung Joon Choi;Su Joa Ahn;So Hyun Park;Young Sup Shim;Jeong Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.608-619
    • /
    • 2022
  • Purpose This study aimed to evaluate the natural growth of subepithelial tumors of the small bowel detected on CT. Materials and Methods Consecutive patients who were suspected of having subepithelial tumors of the small bowel between January 2005 and December 2020 were reviewed. Eligible patients with suspected small (< 30 mm) subepithelial tumors on at least two CT evaluations were included in the analysis. The patients' data on demographic characteristics, tumoral characteristics, and tumoral size changes during the follow-up were collected. Results This study included 64 patients with suspected small subepithelial tumors (n = 64) of the small bowel. After a median follow-up of 15.8 months, the diameter and volume growth rates were 0.02 mm/month and 1.5 mm3/month, respectively. A significant correlation was observed between the initial size and the growth rate of the small bowel subepithelial tumors. The group of large-sized tumors (initial diameter ≥ 10 mm) tended to show lobulated contours, heterogeneous enhancement, and necrotic changes more frequently than the group of small-sized tumors (initial diameter < 10 mm). Conclusion Small bowel subepithelial tumors measuring less than 10 mm grew more slowly than those measuring 10-30 mm.

THE ASSESSMENT OF ULTRASONOGRAPHIC ECHOGENICITY IN NORMAL HUMAN PAROTID AND SUBMANDIBULAR GLANDS (정상 이하선과 악하선에 대한 초음파영상의 반향성 평가)

  • Lee Jean;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.167-177
    • /
    • 1997
  • 타액선 병변의 일반적인 영상진단법으로는 타액선조영술, 전산화단층촬영술, 자기공명 영상, 타액선 스캔, 초음파 촬영술이 있다. 이중 초음파촬영술은 타액선내 종양의 유무를 평가하는데 있어서 매우 우수하여, 전산화단층촬영이나 자기공명영상과 더불어 이용되고 있으나, 염증을 진단하는데 있어서는 타액선조영술보다 민감도가 떨어지는 단점이 있다. 일반적으로 타액선의 염증반응시 초음파상은 반향이 정상보다 낮아지며, 내부의 균질성이 떨어지는 양상을 보여 이를 진단의 기준으로 이용해왔으나 정상타액선에서도 반향이 편차가 심할 뿐만 아니라 연령에 따른 정상 타액선의 반향성에 대한 연구가 부족하여 진단에 어려움이 있었다. 이에 저자는 우선적으로 타액선에 병적인 증상이 없는 남녀 90명을 연령별(20-35세 : 청년군, 36~55세 : 중년군, 55-70세 노년군),성별에 따라 분류하여 정상 타액선의 초음파상을 얻었다. 이의 반향을 측정하고, 비만한 정도를 나타내는 체격지수를 구하여 다음과 같은 결과를 얻었다. 1. 이하선과 악하선 모두에서 연령군극_ 따라 반향성이 증가하는 양상을 보였으며, 청년군과 노년군 사이에는 유의한 차이가 있었다(p<0.05). 2. 이하선과 악하선 모두에서 성에 따른 반향성의 유의한 차이는 없었다. 3. 성에 관계없이 악하선의 반향성이 이하선의 반향성보다 높았으며, 남자에 있어서는 유의한 차이가 있었다(p<0.05). 4. 동일한 타액선에서 좌우측 타액선의 반향성의 평균 차이값은 유의한 차이가 없었다. 5. 이하선과 악하선의 반향성은 중등도의 양의 상관관계를 보였다(남자 : r=0.56, 여자 : r=0.54). 6. 체격지수와 타액선의 반향성은 약한 양의 상관관계를 보였다.

  • PDF

Radiologic Diagnosis of Temporomandibular Joint (측두하악관절의 영상진단)

  • Park, Hyok;Chung, A-Young;Jung, Da-Woon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.291-299
    • /
    • 2012
  • There are many kinds of techniques for imaging temporomandibular joints. None of them for imaging "best fit" for every patient of temporomandibular disorder is recommended ideally. It is more important to be able to select the modality that is most adequate and appropriate for a given clinical issue.

3-D Conformal Radiotherapy for CNS Using CT Simulation (입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획)

  • 추성실;조광환;이창걸
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Purpose : A new virtual simulation technique for craniospinal irradiation (CSI) that uses a CT-simulator was developed to improve the accuracy of field and shielding placement as well as patient positioning. Materials and Methods : A CT simulator (CT-SIM) and a 3-D conformal radiation treatment planning system (3D-CRT) were used to develop CSI. The head and neck were immobilized with a thermoplastic mask while the rest of the body was immobilized with a Vac-Loc. A volumetric image was then obtained with the CT simulator. In order to improve the reproducibility of the setup, datum lines and points were marked on the head and body. Virtual fluoroscopy was performed with the removal of visual obstacles, such as the treatment table or immobilization devices. After virtual simulation, the treatment isocenters of each field were marked on the body and on the immobilization devices at the conventional simulation room. Each treatment fields was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR) and digitally composited radiography (DCR) images from virtual simulation. Port verification films from the first treatment were also compared with the DRR/DCR images for geometric verification. Results : We successfully performed virtual simulations on 11 CSI patients by CT-SIM. It took less than 20 minutes to affix the immobilization devices and to obtain the volumetric images of the entire body. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with simulation films to within 5 mm. This not only reducee inconveniences to the patients, but also eliminated position-shift variables attendant during the long conventional simulation process. In addition, by obtaining CT volumetric image, critical organs, such as the eyes and the spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. Differences between the DRRs and the portal films were less than 3 m in the vertebral contour. Conclusion : Our analysis showed that CT simulation of craniospinal fields was accurate. In addition, CT simulation reduced the duration of the patient's immobility. During the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization by standard protocol for craniospinal irradiation.

  • PDF

Angiographic Findings of an Isolated Meandering Pulmonary Vein: A Case Report (단독 사행 폐정맥의 혈관 조영술 소견: 증례 보고)

  • Ji Su Ko;Lyo Min Kwon;Han Myun Kim;Ji Young Woo;Yoo Na Kim;Jung Won Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.1018-1023
    • /
    • 2021
  • A meandering pulmonary vein (MPV) is a rare pulmonary vascular anomaly characterized by an abnormal course of the pulmonary vein draining into the left atrium. We report the case of a 55-year-old female who was diagnosed with a right MPV on pulmonary angiography. Enhanced chest CT revealed a vascular structure with an abnormal course that drained into the right superior pulmonary vein in the right upper lobe, which resembled a pulmonary arteriovenous malformation (AVM). Pulmonary angiography performed to discriminate between an MPV and pulmonary AVM showed no feeding artery, normal parenchymal staining, and drainage to the left atrium via the culprit vessel. Thus, the patient was diagnosed with MPV. When an MPV is difficult to differentiate from other vascular anomalies on enhanced chest CT, pulmonary angiography can be helpful. By recognizing the angiographic findings of an MPV, unnecessary treatment can be prevented.

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

Type of medical institutions according to the Equipment List and inspection fee computed tomogaphy relationship between (의료기관 종별에 따른 전산화단층촬영장비 보유현황과 검사료간의 관계)

  • Kim, Min-Cheol;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.195-196
    • /
    • 2011
  • 1996년 이후부터 전산화단층촬영 검사가 건강보험급여대상이 되면서 이용률과 보급률이 더욱 증가되고 있으며 검사범위의 확대, 검사시간의 단축, 반복검사의 용이성, 이용의 편리성, 결과의 신뢰성, 장치의 구조적인 요소 및 검사 시행 횟수의 증가 등으로 검사량이 증가되고 있는 실정이다. CT 검사 건수의 증가요인으로 새로운 CT장비의 개발과 더불어 급격한 장비도입 증가 추세가 있으므로 이에 본 연구에서는 의료기관 종별 및 시기별 CT 장치 보유현황과 검사료간의 관계를 파악하였다. CT 장비는 병원급은 증가하고 있는 추세이나 의원급은 감소하고 있는 것으로 나타났다. CT진료비 청구는 80%이상이 종합전문요양기관과 종합병원에서 청구하는 것으로 나타났다. 이에 본 연구에서는 고가의료영상 진단 장비인 CT의 세대별 발달장비 도입 시기에 따른 우리나라 CT의 현황을 조사 분석하여 제시하여 고가의료장비 수급의 정책수립의 계기 및 기여하고자 한다.

  • PDF

The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography (관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가)

  • Choi, Nam-Gil;Choi, Jae-Seong;Han, Jae-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4411-4417
    • /
    • 2010
  • This study was retrospectively to compare the exposure dose and the imaging quality in coronary CT angiography by using the 64 channel multidetector computed tomography and the 128 channel DSCT. Effective dose was calculated dose length product (DLP) by multiplied the convention factor of chest (0.017). Imaging quality was assessed by radiologists using the 5-point Likert scale. The DLP was ranged from 851 to $1277mGy{\cdot}cm$ (mean: 17.23 mSv) in the 64 channel MDCT and from 82 to $110mGy{\cdot}cm$ (mean: 1.58 mSv) in the of 128 channel DSCT, respectively. The score of imaging quality was respectively $3.31{\pm}0.62$ in 64 channel MDCT and $4.05{\pm}0.46$ in the 128 channel DSCT. The exposure dose of 128 channel DSCT has decreased 1ess 1/10. The score of imaging quality was significant difference between two modalities and the frequency (>4 good) in the 128 channel DSCT is about three times than that of the 64 channel MDCT. Therefore, the 128 channel DSCT in coronary CT angiography is clinically more effective modality for both investigators and patients.

Accuracy of Nodal Staging with Integrated PET/CT Scanning in Non-small Cell Lung Cancer (양전자단층촬영/전산화단층촬영(integrated PET/CT)을 이용한 비소세포폐암의 림프절 병기판정)

  • Kim, Ji-Hoon;Chung, Won-Sang;Kim, Young-Hak;Kim, Hyuck;Jeon, Seok-Chol
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.700-704
    • /
    • 2010
  • Background: For staging primary lung cancer, integrated positron emission tomography/computed tomography (PET/CT) imaging is popular. The purpose of this study was to evaluate the accuracy of PET/CT scanning in lymph nodal staging of lung cancer. Material and Method: We studied 48 patients who had received CT, PET/CT and pulmonary resections due to primary non-small cell lung cancer in our hospital between January 2006 and August 2009. Mediastinal lymph nodes were classified as superior mediastinal nodes, aortic nodes, inferior mediastinal nodes, or N1 nodes. We compared the power of CT and PET/CT for diagnosing pulmonary lymph nodes for each of the four types of nodes. Result: PET/CT was more sensitive than CT for all groups except inferior mediastinal nodes. However, the differences were not significant (McNemar's test: superior mediastinal nodes, p=0.109; aortic nodes, p=1.000; inferior mediastinal nodes, p=0.625, N1 nodes, p=0.424). Conclusion: The accuracy of PET/CT is similar to that of CT alone for staging lymph nodes. The two imaging modalities might be used as complementary, cooperative tools. We expect that integrated PET/CT will be found to be significantly mmore sensitive after more trials are done and more data is accumulated.