• Title/Summary/Keyword: 전산화단층촬영 영상

Search Result 505, Processing Time 0.031 seconds

Treatment Planning for Minimizing Carotid Artery Dose in the Radiotherapy of Early Glottic Cancer (조기 성문암의 방사선치료에서 경동맥을 보호하기 위한 치료 계획)

  • Ki, Yang-Kan;Kim, Won-Taek;Nam, Ji- Ho;Kim, Dong-Hyun;Lee, Ju-Hye;Park, Dal;Kim, Don-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Purpose: To examine the feasibility of the treatment planning for minimizing carotid artery dose in the radiotherapy of early glottic cancer. Materials and Methods: From 2007 to 2010, computed tomography simulation images of 31 patients treated by radiotherapy for early glottic cancer were analyzed. The virtual planning was used to compare the parallel-opposing fields (POF) with the modified oblique fields (MOF) placed at angles to exclude the ipsilateral carotid arteries. Planning target volume (PTV), irradiated volume, carotid artery, and spinal cord were analyzed at a mean dose, $V_{35}$, $V_{40}$, $V_{50}$ and with a percent dose-volume. Results: The beam angles were arranged 25 degrees anteriorly in 23 patients and 30 degrees anteriorly in 8 dose-volume of carotid artery shows the significant difference (p<0.001). The mean doses of carotid artery were 38.5 Gy for POF and 26.3 Gy for MOF and the difference was statistically significant (p=0.012). Similarly, $V_{35}$, $V_{40}$, and $V_{50}$ also showed significant differences between POF and MOF. Conclusion: The modified oblique field was respected to prevent a carotid artery stenosis and reduce the incidence of a stroke based on these results.

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

Study on Optimum Contrast Medium Quantity during Abdominal CT using Dual Energy Technique (복부 CT 검사 시 이중에너지 기법을 통한 적정한 조영제 양에 관한 연구)

  • Kang, Min;Choi, Namgil;Han, Jaebok;Kim, Wook;Jang, Yeongill;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • The purpose of this study is finding optimum contrast medium quantity during abdominal CT using dual energy technique. The study subjects are 30 patients who had received general single energy abdominal CT and received double energy technique follow-up abdominal CT. dual energy technique abdominal CT images were obtained after setting contrast medium quantities at 30%, 40%, 50%, 60% and 70% of contrast medium quantity at the time of single energy technique. Then the contrast enhancement (Hounsfield Unit; HU) was estimated by setting-up the regions of interest at aorta, inferior vena cava, hepatic portal vein and hepatic parenchymal. The obtained values were compared to the values of the same parts measured during single energy technique abdominal CT. The results of the study were as following. The 60% set up group had HU in aorta : $210.80{\pm}13.609$, IVC : $190.40{\pm}25.215$, hepatic portal vein : $198.40{\pm}21.232$ and hepatic parenchymal : $119.20{\pm}7.98$, The single energy abdomianl CT images had HU in aorta : $205.40{\pm}16.426$, IVC : $188.20{\pm}21.476$, hepatic portal vein : $195.40{\pm}22.744$ and hepatic parenchymal : $121.00{\pm}6.595$. Therefore, it is possible to obtain contrast enhancement by dual energy technique abdominal CT similar to the same by single energy technique abdominal CT by setting-up the quantity of contrast medium at 60% of contrast medium at the time of single energy technique abdominal CT. Based on the result of this study, it is possible to decrease existing quantity of contrast medium by _% and the injection velocity can be also decreased. Accordingly, it is believed that the result of study would be quite useful for patients who have renal function disorder, weak vein or side effect of contrast medium in the past.

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient (3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰)

  • Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.

  • PDF

The pattern of movement and stress distribution during retraction of maxillary incisors using a 3-D finite element method (상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Chung, Ae-Jin;Kim, Un-Su;Lee, Soo-Haeng;Kang, Seong-Soo;Choi, Hee-In;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.98-113
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the displacement pattern and the stress distribution shown on a finite element model 3-D visualization of a dry human skull using CT during the retraction of upper anterior teeth. Methods: Experimental groups were differentiated into 8 groups according to corticotomy, anchorage (buccal: mini implant between the maxillary second premolar and first molar and second premolar reinforced with a mini Implant, palatal: mini implant between the maxillary first molar and second molar and mini implant on the midpalatal suture) and force application point (use of a power arm or not). Results: In cases where anterior teeth were retracted by a conventional T-loop arch wire, the anterior teeth tipped more postero-inferiorly and the posterior teeth moved slightly in a mesial direction. In cases where anterior teeth were retracted with corticotomy, the stress at the anterior bone segment was distributed widely and showed a smaller degree of tipping movement of the anterior teeth, but with a greater amount of displacement. In cases where anterior teeth were retracted from the buccal side with force applied to the mini implant placed between the maxillary second premolar and the first molar to the canine power arm, it showed that a smaller degree of tipping movement was generated than when force was applied to the second premolar reinforced with a mini implant from the canine bracket. In cases where anterior teeth were retracted from the palatal side with force applied to the mini implant on the midpalatal suture, it resulted in a greater degree of tipping movement than when force was applied to the mini implant between the maxillary first and second molars. Conclusion: The results of this study verifies the effects of corticotomies and the effects of controlling orthodontic force vectors during tooth movement.

The Secondary Contiguous or Non-contiguous Subchondral Bone Impactions in Subaxial Cervical Spinal Injury: Incidence and Associated Primary Injury Patterns (축추이하 경추 손상에서 이차적으로 발생하는 연속적, 비연속적 연골하골 압박손상의 빈도와 원발부위 손상 패턴)

  • Han, Jun Gu;Kim, Yeo Ju;Yoon, Seung Hwan;Cho, Kyu Jung;Kim, Eugene;Kang, Young-Hye;Lee, Ha Young;Cho, Soon Gu;Kim, Mi Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.232-243
    • /
    • 2014
  • Purpose : To evaluate the incidence of secondary contiguous or non-contiguous subchondral bone impactions (SBI) in subaxial cervical spinal injury and associated primary injury patterns. Materials and Methods: A retrospective review of computed tomography, magnetic resonance imaging, and medical records was carried out for 47 patients who had sustained a subaxial cervical spinal injury. Presence, number, level, and sites of secondary contiguous or non-contiguous SBI were recorded. To evaluate primary injury patterns, the level and number of primary injury sites of subaxial cervical spine injury, injury morphology, anterior/posterior discoligamentous complex (ADC/PDC) injury, posterior ligamentous complex (PLC) injury, spinal cord injury, and mechanism of injury (MOI) were analyzed. Differences in primary injury pattern of subaxial cervical spine injury and MOI between patients with and without SBI, and between contiguous or non-contiguous SBI were analyzed using the Mann-Whitney U test, Pearson's chi square test and Fisher's exact test. Results: Eighteen patients (18/47, 38.29%) had developed contiguous (n=9) or non-contiguous (n=9) SBI, most commonly involving T3 (15/47, 31.91%) and 3 levels (6/18, 33.33%). All SBIs had developed near the anterosuperior region of the body and the superior endplate and were the result of a high-impact MOI. SBIs were statistically significant in association with injury morphology and PLC injury (P=0.001, P=0.009, respectively) at the primary injury site. Non-contiguous SBI was more frequently accompanied by upper cervical spinal injuries in association with PDC injuries, as opposed to contiguous SBI, with statistical significance (P=0.009), while no other statistically significant differences were found. Conclusion: Secondary SBIs are common and probably associated with subaxial cervical spinal injuries with high energy compressive flexion forces.

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

Results of Three-Dimensional Conformal Radiation Therapy for the Treatment of a Solitary Sternal Relapse of Breast Cancer (흉골에 단독 전이된 유방암의 삼차원 입체조형 방사선 치료 성적)

  • Kim, Hae-Young;Huh, Seung-Jae;Park, Won;Choi, Do-Ho;Kang, Min-Kyu;Yang, Jung-Hyun;Nam, Seok-Jin;Im, Young-Hyuck
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.91-95
    • /
    • 2008
  • Purpose: To evaluate the response and survival rate after three-dimensional conformal radiation therapy(3D-CRT) of patients with a solitary sternal relapse of breast cancer. Materials and Methods: Seventeen patients between May 1996 and June 2005 were evaluated with the salvage 3D-CRT treatment of a solitary sternal relapse of breast cancer. The treatment fields included the gross tumor volume with 2 cm margins. The total radiation dose was $35.0{\sim}61.5$ Gy(biologic effective dose of $43.7{\sim}76.9Gy_{10}$ using an $\alpha/\beta$ ratio of 10 Gy), with a daily dose of $1.8{\sim}3.0$ Gy. The tumor response was evaluated by the change in maximum tumor size via follow up CT scans $1{\sim}3$ months after the completion of treatment. Results: An objective tumor response was achieved in all patients, with a complete response in 5 patients and a partial response in 12 patients. The 5-year overall survival rate was 51.9%(median survival time: 27 months), and the most important factor affecting overall survival was the disease-free interval(interval from primary surgery of breast cancer to the development of sternal metastasis): The 5-year overall survival rate was 61.8% for patients with a disease-free interval ${\geq}12$ months and 0.0% for patients with disease-free interval <12 months(p=0.03). Conclusion: The response to 3D-CRT was good in patients with solitary sternal relapse of breast cancer. Particularly, patients with long disease-free interval from primary surgery survived significantly longer than patients with short disease-free interval from primary surgery.