• Title/Summary/Keyword: 전산화단층촬영장치

Search Result 103, Processing Time 0.027 seconds

Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality (흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가)

  • Kim, Min Kyoung;Kwak, Hyeng Ju;Kim, Jong Hun;Choe, Won-Ho;Ha, Yun Kyung;Lee, So Jung;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.143-147
    • /
    • 2016
  • Recently, digital tomosynthesis system (DTS) has been developed to reduce overlap using conventional X-ray and to overcome high patient dose problem using computed tomography (CT). The purpose of this study was to develop image reconstruction algorithm and to evaluate image characteristics and dose with chest digital tomosynthesis (CDT) system. Image reconstruction was used for filtered back-projection (FBP) methods and system geometry was constructed ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, and ${\pm}30^{\circ}$ angular range for acquiring phantom images. Image characteristics carried out root mean square error (RMSE) and signal difference-to-noise ratio (SDNR), and dose is evaluated effective dose with ${\pm}20^{\circ}$ angular range. According to the results, the phantom image with slice thickness filter has superb RMSE and SDNR, and effective dose was 0.166 mSv. In conclusion, we demonstrated usefulness of developed CDT image reconstruction algorithm and we constructed CDT basic output data with measuring effective dose.

Cardiac Rupture Combined with Massive Right Hemothorax by Blunt Chest Trauma -A report of two cases- (흉부둔상환자에서 중증우측혈흉을 동반한 심장파열 -치험 2례-)

  • 정은규;이병욱;윤용한;백완기;김광호;류송현;김혜숙;김정택
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.173-175
    • /
    • 2001
  • 흉부둔상에 의한 심장파열은 50% 이상의 치사율을 갖는 질환으로 응급실에 도착하기 전에 사망하는 경우가 대부분이다. 일반적으로 전형적인 심장압전을 동반하기 때문에 이학적 소견이나 심장초음파 또는 흉부전산화 단층촬영으로 진단이 가능하다. 그러나 저자의 경우와 같이 심장압전의 징후가 없이 중증 우측혈흉만 있는 경우 심장파열을 진단하는 것은 어렵다. 만약 고속의 자동차사고로 인한 흉부둔상을 받은 환자에서 늑골골절이 없이 우측에 중증의 혈흉이 있어 응급개흉술을 받아야 한다면 심장파열의 가능성을 염두에두고 수술을 계획하는 것이 필요하다고 생각한다. 본 인하대학교 흉부외과학 교실에서는 흉부둔상에 의한 중증우측 혈흉과 심낭파열을 동반한 심장파열 2례를 심패바이패스와 자가수혈 장치를 이용하여 효과적으로 치료하였기에 보고하는 바이다.

  • PDF

Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull (전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교)

  • Kang Bok-Hee;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

Estimation of Computed Tomography Dose in Various Phantom Shapes and Compositions (다양한 팬텀 모양 및 재질에 따른 전산화단층촬영장치 선량 평가)

  • Lee, Chang-Lae
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • The purpose of this study was to investigate CTDI (computed tomography dose index at center) for various phantom shapes, sizes, and compositions by using GATE (geant4 application for tomographic emission) simulations. GATE simulations were performed for various phantom shapes (cylinder, elliptical, and hexagonal prism PMMA phantoms) and phantom compositions (water, PMMA, polyethylene, polyoxymethylene) with various diameters (1-50 cm) at various kVp and mAs levels. The $CTDI_{100center}$ values of cylinder, elliptical, and hexagonal prism phantom at 120 kVp, 200 mAs resulted in 11.1, 13.4, and 12.2 mGy, respectively. The volume is the same, but $CTDI_{100center}$ values are different depending on the type of phantom. The water, PMMA, and polyoxymethylene phantom $CTDI_{100center}$ values were relatively low as the material density increased. However, in the case of Polyethylene, the $CTDI_{100center}$ value was higher than that of PMMA at diameters exceeding 15 cm ($CTDI_{100center}$ : 35.0 mGy). And a diameter greater than 30 cm ($CTDI_{100center}$ : 17.7 mGy) showed more $CTDI_{100center}$ than Water. We have used limited phantoms to evaluate CT doses. In this study, $CTDI_{100center}$ values were estimated and simulated by GATE simulation according to the material and shape of the phantom. CT dosimetry can be estimated more accurately by using various materials and phantom shapes close to human body.

The Analysis of Cerebral Aneurysm's Prone position Using Computed Tomography Equipment (전산화단층촬영장치를 이용한 뇌동맥류의 호발부위 분석)

  • Lee, Seon-Tae;Lim, Jong-Soo;Park, Jeong-Kyu
    • Journal of Digital Contents Society
    • /
    • v.12 no.3
    • /
    • pp.271-277
    • /
    • 2011
  • This research studied 249 patients who has an aneurysm and went through computerized CT angiography at S University Hospital in Northern Kyung-sang area from October 1st 2008 to September 30th 2010, and the results are the following. Among total 249 of research objects, 159 women (63.9%) showed higher distribution than 90 men (36.1%) The order of the distribution of aneurysm classified by blood vessel is the following. Posterior communicating artery 34.9% as the highest, internal carotid artery 21.7%, middle cerebral artery of 15.7%, anterior communicating artery 14.5%, posterior cerebral artery and posterior cerebral artery channel 3.6% each, anterior cerebral artery and vertebral artery 2.4% each, and posterior inferior cerebellar artery 1.2%. As a result of analysis of distribution of aneurysm classified by gender, there was no case of posterior cerebral artery and posterior cerebral artery channel among men, and there was no case of posterior inferior cerebellar artery among women. Distribution of aneurysm classified by vessel according to gender showed no statistic significance. (p<0.05). And distribution of aneurysm classified by vessel according to the age, showed no statistic significance. (p>0.05), After applying post analysis to understand the group with age difference, the significance was the highest among the group of 61-70, (4.21), and the group of the age under 30 was the lowest. (2.0) There was statistic significance on the distribution of aneurysm classified by vessel according to the season. (p<0.05). After applying post-analysis in order to understand the groups with difference between seasons, it was found that fall was the highest (4.55) and spring was the lowest. (2.50)

A Study on the Improvement of Evaluation Methods and Standards for Simulation Evaluation of Computed Tomography (전산화단층촬영용장치의 모의 평가를 통한 평가방법 및 평가기준의 개선방안에 관한 연구)

  • Kim, Kyo-Tae;Heo, Ye-Ji;Shin, Jung-Wook;Noh, Si-Cheul;Jung, Bong-Jae;Kang, Sang-Sik;Nam, Sang-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.339-345
    • /
    • 2013
  • In foreign countries, the impotance of quality assurance (QA) is increasing, whereas QA evaluation standards are not established properly in Korea. Thus this study was conducted to suggest improved QA evaluation standards and methods by studying/comparing/analyzing the literature in both Korea and foreign countries and prove its suitability through simulated evaluation. result of research in south korea, much check list using the evaluation method subjective, the evaluation of accuracy and reproducibility is meausred in the number of missing. Therefore, attempts to present a clear reference evaluation and objective way to solve the problem, examined the accuracy and reproducibility and 10times of measurement. The results of the simulated evaluation satisfied both proposed evaluation standards and methods. However the QA evaluation standards and methods for the items that are implemented only in Korea and high-contrast spatial resolution could have been established. In this regard, there is a need of further studies on the establishment of QA evaluation standards and methods that suits Korean situation.

Development of A Fractionated Stereotactic Radiotherapy System (분할 정위방사선 치료 시스템 개발 연구)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • We invented the newly developed Fractionated Stereotactic Radiotherapy(F.S.R.T) system using combined techniques of couch mounting and pedestal mounting system. Head fixation frame consists of a milled alluminium alloy(duralumin) and is placed to the couch. This frame immobilized patient head using the dental bite, 3.2 mm frontal and occipital thermoplastic mask. To evaluate the coordinate of target isocenter, Brown-Revert-Walls C.T localizer can be attached to this frame. And also, we developed the frame mounting system by developing the modification of pedestal mounting system. This system is fixed to couch floor and can be used to evaluate the isocenteric accuracy of gantry, couch and collimator in Q.A procedure. In order to measure the relocation accuracy, the acrylic phantom and the accurate pointers have been made. The repositioning of the targets in the phantom were estimated by comparing C.T coordinates and E.C.L portal films taken with anterior-posterior and right-left direction. From the results of experiments, the average distance errors between the target isocenter and its mean position were 0.71$\pm$0.19 for lateral, 0.45$\pm$0.15 for inferior-superior, 0.63$\pm$0.18 for anterior-posterior. And the maximum distance error was less than 1.3 mm. The new head fixation frame and frame mounting system were non-invasive, accurately relocatable, easy to use, very light and well tolerable by the results of phantom tests. The major advantage of using this frame mounting system is complete access to any point in the Patients cranium especially posterior direction

  • PDF

The Effects of the CT Voltages on the Dose Calculated by a Commercial RTP System (CT 관전압이 상용 전산화치료계획장치의 선량계산에 미치는 영향)

  • 강세권;조병철;박희철;배훈식
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • The relationship between the dose calculated with a radiotherapy treatment planning system (RTPS) and CT number verses the relative electron density curve was investigated for various CT voltages and beam qualifies. We obtained the relationship between the CT numbers and electron densities of the tissue equivalent materials for various CT voltages and beam qualifies. At lower CT voltages, the higher density materials, like cortical bone, showed larger CT numbers and the soft tissues showed no variations. We peformed a phantom study in a RTPS, where a phantom consisted of lung and bone legions in water. We calculated the dose received behind the lung and bone regions for 6 MV photon beams, in which the regions below the lung, water and bone received higher doses in this listed order. The result was the same for 10 MV photon beams. For the clinical application, the doses were calculated for the lung and pelvis. No difference was observed when using different electron density conversion tables with various CT voltages from a same CT. A relative dose difference of 1.5% was obtained when the CT machine for the density conversion table was different from that for the CT image for planning.

  • PDF

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.