• Title/Summary/Keyword: 전산화단층검사

Search Result 439, Processing Time 0.021 seconds

Evaluation of Dose and Image Quality of Lens according to Baseline during Brain CT Scan (두부 전산화단층촬영 시 기준선에 따른 수정체 선량과 화질 평가)

  • Kim, Kyu-Hyung;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.699-704
    • /
    • 2019
  • It is important to minimize the exposure dose during an examination and obtain good quality images at the same time. This study compared the beam harding effect according to the baseline superior orbito meatal line(SOML), orbito meatal line(OML), inferior orbito metal line(OML) and measured the exposure dose of the lens, especially in brain CT examinations, which generally apply to head diease patients. The beam harding effect assessment of each image along the baseline was performed quantitatively using the Image J program, and the exposure dose of the lens was detected by OSLDs and compared. As a result, As a result, when the SOML was used as the reference line, the dose of the lens was decreased by 85.08% at 80 kV and by 79.7% at 80 kV, compared to when IOML was used as the baseline. If the gantry angle at brain CT was parallel scan to SOML, there were no significant differences in the exposure to the lens and between the OML and IOML. Therefore, this study has shown that it is efficient to have a parallel scan on SOML as a protocol during Brain CT examinations.

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF

Evaluation of Myocardial Ischemia Using Coronary Computed Tomography Angiography in Patients with Stable Angina (안정형 협심증 환자들에서 관상동맥 전산화단층촬영을 이용한 심근허혈의 평가)

  • Sung Min Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.250-271
    • /
    • 2020
  • Assessment of myocardial ischemia in patients with stable angina is important in deciding whether to treat coronary artery disease and in predicting clinical outcome. The fractional flow reserve is a standard reference for the diagnosis of myocardial ischemia, but this procedure has limitations because of its invasiveness. Coronary computed tomography angiography (CCTA) is now an established tool in the anatomic diagnosis of coronary artery disease; however, there are limits to the diagnosis of hemodynamically important stenosis that causes myocardial ischemia. In order to address this problem, studies using quantification of coronary atherosclerotic plaques, myocardial perfusion, and noninvasive calculation of fractional flow reserve based on CCTA have been actively conducted and recognized for their diagnostic value. In this review, several imaging techniques of CCTA used to assess myocardial ischemia are described.

Analysis on the Entrance Surface Dose and Contrast Medium Dose at Computed Tomography and Angiography in Cardiovascular Examination (심장혈관검사에서 전산화단층검사와 혈관조영검사의 입사표면선량 및 조영제 사용량에 관한 분석)

  • Seo, Young-Hyun;Han, Jae-Bok;Choi, Nam-Gil;Song, Jong-Nam
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.535-541
    • /
    • 2016
  • This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48~85 years old (mean $65{\pm}10$ years old), and the weight was 37.6~83.3 kg (mean $63{\pm}6kg$). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

CT Findings of Central Airway Lesions Causing Airway Stenosis-Visualization and Quantification: A Pictorial Essay (협착을 유발하는 중심 기관지 병변들의 전산화단층촬영 소견-시각화 및 정량화: 임상화보)

  • Myeong Jin Choi;Hee Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1441-1476
    • /
    • 2021
  • The tracheobronchial tree is a system of airways that allows the passage of air to aerate the lungs and entire body. Several pathological conditions can affect this anatomical region. Multidetector CT (MDCT) helps identify and characterize various large airway diseases. Post-processing tools, such as virtual bronchoscopy and automatic lung analysis, can help enhance the performance of imaging studies. In this pictorial essay review, we provide imaging findings of various bronchial lesions manifested as wall thickening and endoluminal nodules on conventional MDCT and advanced image visualization and analysis.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

A Case of Atypical Pathogen Pneumonia, associated with Recurrent into Diffuse Pneumonic Consolidation (재발성 경과를 취한 비정형 병원균주 폐렴 환자 1예)

  • Oh, Jong-Kap
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.391-400
    • /
    • 2011
  • Pneumonia is an infection of the lungs and respiratory system and can be classified by a variety of factors such as infectious agents, etiology, infection area, and other criteria. From a 46-year-old male, who was suspected of being infected with atypical pathogen pneumonia and underwent such tests as serological testing, examination of sputum, urine examination, parasite examination, bronchoscopy, needle biopsy and so on, no significant abnormality was found. This patient also showed no specific symptoms like auscultatory abnormalities, high fever, nonproductive cough, muscle stiffness, sputum production, dyspnea. Prescription of broad-spectrum oral antibiotics and ant-parasitic didn't seem to be effective against bacterial and atypical pathogen. The patient's condition alternately repeated between natural cure and recurrence. The average healing process during which scarring, nodule recurrence and disappearance on the lungs happened was about 20 days. Chest radiography and chest high resolution computerized tomographic scans(HRCT scan) was performed to depict parenchymal aberrations and demarcate the extent and distribution of atypical pathogen pneumonia. As a result, chest radiography did not show the specific symptoms, whereas areas of opacity (seen as white) which represent consolidation were revealed in chest HRCT scan. This indicates that only chest radiography is not that useful for early diagnosis of atypical pathogen pneumonia in patients, since it can't show exactly what the symptom is because of the barriers such as diaphragm, liver, and spine. Therefore, it is desirable that chest HRCT should be used in the diagnosis to compare with the results of chest radiography. Here, report with literature investigations the case of recurrent atypical pathogen pneumonia.

Beyond Coronary CT Angiography: CT Fractional Flow Reserve and Perfusion (전산화단층촬영 관상동맥조영술: 분획혈류예비력과 심근관류 영상)

  • Moon Young Kim;Dong Hyun Yang;Ki Seok Choo;Whal Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.3-27
    • /
    • 2022
  • Cardiac CT has been proven to provide diagnostic and prognostic evaluation of coronary artery disease for cardiovascular risk stratification and treatment decision-making based on rapid technological development and various research evidence. Coronary CT angiography has emerged as a gateway test for coronary artery disease that can reduce invasive angiography due to its high negative predictive value, but the diagnostic specificity is relatively low. However, coronary CT angiography is likely to overcome its limitations through functional evaluation to identify the hemodynamic significance of coronary artery disease by analyzing myocardial perfusion and fractional flow reserve through cardiac CT. Recently, studies have been actively conducted to incorporate artificial intelligence to make this more objective and reproducible. In this review, functional imaging techniques of cardiac computerized tomography are explored.

Squamous Cell Carcinoma in the Base of the Tongue in a Dog (개의 혀 뿌리에서 발생한 편평세포암종)

  • Kim, Se-Eun;Kim, Seung-Hyun;Shim, Kyung-Mi;Bae, Chun-Sik;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.30-33
    • /
    • 2016
  • It is difficult to detect and diagnose a mass at the tongue base, particularly if the mass is located under normal appearing mucosa. Computed tomography (CT), particularly post-contrast images, is useful to evaluate a tongue mass and adjacent structures including cervical lymph nodes. Nevertheless, a definitive diagnosis of a mass is obtained by histopathological examination. In this case, we describe a mass arising from the tongue body to the root in a dog. The patient was referred with ptyalism and an eating disorder. An oral examination was performed, and decreased tongue motility was observed. CT scanning was performed, and a lingual mass was detected. A lingual mass sample was collected by biopsy at the postmortem 2 months later. A histopathological examination was performed, and the lingual mass was diagnosed as squamous cell carcinoma.