• Title/Summary/Keyword: 전류 파형

Search Result 431, Processing Time 0.026 seconds

Soft Switching Single Stage AC-DC Full Bridge Boost Converter Using Non-Dissipative Snubber (무손실 스너버 적용 소프트 스위칭 Single Stage AC-DC Full Bridge Boost 컨버터)

  • 김은수;조기연;김윤호;조용현;박경수;안호균;박순구
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.377-383
    • /
    • 1999
  • A new soft switching single stage AC-DC full bridge boost converter with unit input power factor and isolated output i is presented in this paper. Due to the use of a non-dissipative snubber on the primary side, a single stage high-power f factor isolated full bridge boost converter has a significant reduction of switching losses in the main switching devices. The non-dissipative snubber adopted in this study consists of a snubber capacitor Cr, a snubber inductor Cr, a fast r recovery snubber diode Dr' and a commutation diode Dp. This paper presents the complete operating principles, t theoretical analysis and experimental results.

  • PDF

The Improvement of Output Voltage of UPS Using a Parallel Control Method (병렬 제어기법을 이용한 UPS 출력 전압의 개선)

  • 成 炳 模;姜 弼 淳;朴 晟 濬;金 喆 禹
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.158-164
    • /
    • 2002
  • This paper presents a proper parallel control method using a conventional control and a repetitive control for improving the output voltage waveform of uninterruptable power supply. Although first-order prediction control method shows a good characteristics to rectifier load, it is not sufficient to reduce steady state errors generated in nonlinear loads such as rectifier loads and phase controled loads. So we also employed a repetitive control method. A repetitive control method can eliminate steady state errors in the distorted output voltage caused by cyclic loads. The presented control scheme is verified through simulation and experiment. Experimental results Implemented on a single phase PWM inverter equipped with a LC output filter with 3 kVA, 60 Hz are shown.

Optimum Parameter Design for Defibrillator (제세동기 최적 파라미터 설계)

  • Yoon, H.Y.;Ko, H.W.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.245-251
    • /
    • 1997
  • In designing defibrillator, several parameters such as patient's transthoracic impedance, output energy level, peak current, and time duration of current waveform must be considered to generate optimum electrical shocks on the heart. Patient's transthoracic impendence depends on the physical and health condition of patient. In this study, before the development of a defibrillator, the range of above parameters value as circuit elements was determined to derive optimal waveform by predicting and analyzing the performance of designed circuit by means of simulation with the software, P-Spice. The efficiency of parameter design was verified through the performance test with the developed defibrillator.

  • PDF

The Current and Power Waveform Improvement of a $3{\Phi}$ Induction Motor with LC Filter Driven by a Digital Bridge Inverter (디지탈 브리지형 인버터로 구동되는 3상유도전동기의 LC 필터에 의한 전류 및 전력 파형 개선)

  • Chung, J.Y.;Park, J.G.;Kang, C.N.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.553-555
    • /
    • 1996
  • This paper concerns with a method to improve the current and power waveforms of the variable speed $3{\Phi}$ AC motor system driven by the single-pulse PWM, and the current waveforms and $3{\Phi}$ power waveforms are analyzed by FFT under various running conditions. By the performance analysis through the experiments, the following results have been obtained. AC source of pseudo sine waveform can be obtained from the modulated alternating square voltage by means of the well designed LC filter. It is confirmed that current waveforms and $3{\Phi}$ power waveforms can be improved by utilizing the high order low pass LC filter than that of lower order. Especially, current waveforms and $3{\Phi}$ power waveforms tan be much improved at low frequency domain. $3{\Phi}$ power waveforms have a smatter ripple and bigger power by utilizing the high order low pass LC filter than that of lower order. Also, the running condition of $3{\Phi}$ AC motor is good at low frequency domain.

  • PDF

Effect of Short Circuit Time Ratio and Current Control Pattern on Spatter Generation in $CO_2$ Welding ($CO_2$용접의 스패터 발생에 미치는 단락시간비 및 단락전류 파형제어의 영향)

  • 조상명
    • Journal of Welding and Joining
    • /
    • v.21 no.1
    • /
    • pp.48-53
    • /
    • 2003
  • The object of this study is to examine the effect of short circuit time ratio (SCTR) and current rise delay time (Td) on the spatter generation at low and medium current range in $CO_2$ welding. The spatter was evaluated by the weight generated in the welding of bead-on-plate for 30 seconds (3 times). Td was varied by order of 0, 0.4, 0.8 and 1.2 msec. At each Td, the short circuit time ratio was varied by the output voltage of the welding power source. In the low current range, it was found that the optimum SCTR was 20~25%, and the minimum spatter generation weight was obtained in the case of Td=0.4msec and SCTR=22% even though the remarkable difference was not showed by the application of Td. In the medium current range, it was confirmed that the arc was stable though the SCTR was increased from 20% to 40% by the control of current wave. Spatter generation weight depended on the variation of Td, and the lowest value of spatter generation weight occurred at Td=0.8~1.2msec.

A Study on Modeling of Short-Circuliting Phenomena and Selection of Current Waveform for Reduction of Spatter in GMAW (가스 메탈 아크 용접에서 단락현상 모델링 및 스패터 감소를 위한 전류파형 선정에 관한 연구)

  • 황주호;문형순;나석주;한광수
    • Journal of Welding and Joining
    • /
    • v.14 no.1
    • /
    • pp.57-67
    • /
    • 1996
  • With an expansion in automation of welding processes, emphasis has been shifted from other welding processes to the GMA welding. However, there is a problem with this process that the spatter occurs very frequently. In GMA welding, there are several types in the way of metal transfer from the electrode wire to the weld pool, which have a close relatonship with the spatter genetration. This study was concerned with the spatter occurring in the short-circuiting transfer. In welding with short-circuiting, the electromagnetic force formed by the welding current facilitatics the rupture of the metal bridge between the wire and workpiece and ensures the normal process of the welding process. However, the spatter can be genetrated from the droplet because of the upward magnetic force, when the droplet contacts with the weld pool. The passage of current through the bridge results in the accumulation of the thermal energy, which causes the bridge to explode in the final stage of short-circuiting, thus forming the spatter. Based on the above phenomena in conjunction with other experimental results published, the physical phenomenon related with the occurrence of spatter was modeled and the current waveform was investigated to reduce the spatter. Finally, the fuzzy rule based method was proposed to predict the time of short-circuiting and arcing in the metal transfer.

  • PDF

A study on Parallel running Hydroelectric power Generation breakdown through Reactive Current (무효횡류에 의한 병렬 운전 수력발전소 고장에 관한 연구)

  • Ha, Sung-Jong;Kim, Ji-Chan;Ahn, Jae-Hu;Byeon, Gyu-Yong;Pi, In-Seop;Ye, Cheol-Hae;Jeong, Ho-Un
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.214-215
    • /
    • 2011
  • 2대의 교류발전기 G1과 G2가 병렬운전 중 일 때 내부 기전력 E1, E2는 같은 위상이지만, 크기가 E1>E2로 될 때 두 발전기 사이에는 전위차가 있으므로 횡류 Ic가 흐르게 된다. 남강수력발전소는 주변압기(15MVA, 3.45/66kV) 한대에 수차발전기(7MVA) 2대가 병렬로 운전 중인데, 남강수력 제1호 수차발전기 AVR 시스템의 고장(RS 1기판)으로 G1 발전기의 내부 유기전압과 G2 발전기의 내부 유기전압에 차가 생기고, 이 양자의 차 전압을 전원으로 하여 발전기 G1과 G2를 환류하는 전류가 발생하여 발전 기동 중 비상정지 하였다. 본 논문에서는 고장원인 분석과정 및 AVR 시스템 보수 전 후 파형 비교 및 사고원인을 논하고자 한다.

  • PDF

Module-based Modeling Method of $3\Phi$ Phase-Controlled Rectifier System for DC Motor Drive under Matlab/Simulink environment (Matlab/Simulink 환경하에서 3상 위상제어 정류기-DC 전동기 구동시스템의 모듈별 모델링 기법)

  • 김상민;한우용;이창구;김성중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.15-21
    • /
    • 2000
  • This paper presents the modeling method of $3\Phi$ phase-controlled rectifier for the DC motor drive in MATLAB/SIMULINK environment. This method has no need to extend the system mathematically and thus it's easy to integrate the various systems. The whole model consists of $3\Phi$ phase-controlled rectifier block, DC motor block and speed/current controller block. The simulation results show that the model outputs are almost similar to those of the real system and therefore that the presented method is suitable for the research of the closed-loop controlled power electronic systems.

  • PDF

A Study on the Low Noise Medical SMPS (의료용 SMPS 개발 및 노이즈 감소 대책에 대한 연구)

  • 이정우;김응석;김기만;윤형로
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • The main noise sources in SMPS are divided into three parts: the switching devices, the rectifiers in secondary part, the output transformer and choke coil. In this paper we performed the noise analysis with respect to bobbin type and winding method, and designed an optimized transformer focusing on the transformer. For the comparison. we measured four parameters for each cases, including EMI conducted emission noise. signal from the switching devices, output ripple/noise voltage and leakage current. As the result, the transformer using a vertically-typed bobbin and a parallel, sandwich winding method showed the best performance. We confirmed that the SMPS developed in this research is satisfied with the IEC 601-1 international standard for the medical instrumentation. by testing its electrical characteristics and safety.

  • PDF

A Study on Input Current Waveform Analysis for Step Up-Down AC-DC Converter of High Power Factor added Electric Isolation (고역률 스텝 업-다운 절연형 AC-DC 컨버터의 입력전류 파형분석에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Choon-Sam;Lee, Bong-Seob;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.34-36
    • /
    • 2008
  • This paper is given a full detail of mathematical analyses of input current for novel active type power factor correction(PFC) AC-DC converter of step up-down added electric isolation. These are compared with harmonics components of input current for a conventional PFC converter of electric isolation type. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode(DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of a conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

  • PDF