• Title/Summary/Keyword: 전류 응답

Search Result 398, Processing Time 0.03 seconds

Capless Low Drop Out Regulator With Fast Transient Response Using Current Sensing Circuit (전류 감지 회로를 이용한 빠른 과도응답특성을 갖는 capless LDO 레귤레이터)

  • Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.552-556
    • /
    • 2019
  • This paper present a capless low drop out regulator (LDO) that improves the load transient response characteristics by using a current regulator. A voltage regulator circuit is placed between the error amplifier and the pass transistor inside the LDO regulator to improve the current characteristics of the voltage line, The proposed fast transient LDO structure was designed by a 0.18 um process with cadence's virtuoso simulation. according to test results, the proposed circuit has a improved transient characteristics compare with conventional LDO. the simulation results show that the transient of rising increases from 1.954 us to 1.378 us and the transient of falling decreases from 19.48 us to 13.33 us compared with conventional capless LDO. this Result has improved response rate of about 29%, 28%.

The Optimization of Current Control in DC/AC Power Converters under Digital Control with Microprocessor (마이크로프로세서에 의한 디지탈 제어방식에서 직류/교류 전력변환장치 전류제어 성능의 최적화)

  • 우명호;목형수;정승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.61-69
    • /
    • 1998
  • In this paper, discrete current control of voltage source inverters is proposed. As a current control scheme, the constant switching frequency predictive current control is adopted and implemented with DSP microprocessor system. In particular, the proposed method is for the compensation of the control lagging due to calculation delays in the microprocessor controller. In controlling the current, the inverter output voltage saturation problem is inevitable and usually affects the current control performance. So, the saturation boundary condition of the inverter output voltage and its effects on the current controal performance of the proposed current control scheme are investigated with experiment. Finally, the proposed scheme is applied to the active power filter system and some results are described for validation.

A digitial control algorithm for PDP's DC-DC converters using a load current prediction technique (부하전류 예측기법을 이용한 PDP DC-DC 컨버터의 디지털 제어 알고리즘)

  • Chae S.Y.;Hyun B.C.;Agarwal P.;Cho B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.406-408
    • /
    • 2006
  • 본 논문은 플라즈마 디스플레이 패널(PDP) 전원공급 장치로 사용되는 DC-DC 컨버터의 동적 응답특성을 향상 시킬 수 있는 새로운 디지털 제어 알고리즘을 서술한다. 제안하는 알고리즘은 PDP에 영상을 표시하기 위한 영상 입력신호와 구동회로의 유지방전 파형의 제어를 위한 신호를 이용하여 부하전류의 변화량과 시점을 예측한다. 별도의 추가적인 전류센서를 사용하지 않고 예측된 부하전류 정보는 일반적인 디지털 전압 제어기에 피드포$\sim$워드 형태로 추가되어 적용된다. 제안된 알고리즘은 디지털 Pl 전압 제어기만을 사용한 경우에 비해 부하전류가 급격히 변동할 때 좀 더 빠른 응답특성과 낮은 출력전압 변동 특성을 보인다. 제안된 알고리즘은 FPGA를 사용하여 구현 되었으며, Buck 컨버터를 사용하여 기본 동작을 검증하였다.

  • PDF

A Discrete-time Sliding Mode Control Scheme to Improve Transients of Grid-connected Inverter under Distorted Grid (왜곡 계통 조건에서 계통연계 인버터의 과도응답을 개선하기 위한 이산시간 슬라이딩 모드)

  • Yoon, Seung-Jin;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.338-339
    • /
    • 2018
  • 최근 분산전원 시스템 개발로 인해 계통연계 인버터의 사용이 증가해 왔다. 계통연계 인버터의 주요한 역할은 계통연계 환경에서의 안정적인 운전과 계통 사고 시 중요 부하에 대한 연속적인 전력을 공급하기 위한 독립운전에 있다. 각 모드 전환시의 출력전압의 변동성과 과도응답 특성을 개선하기 위해 최근 다중 루프 및 간접 전류 제어 방식이 계통연계 인버터에 적용되었다. 하지만 이러한 제어 방식은 캐패시터 전압 및 인버터 전류의 측정이 요구되어 시스템의 비용 및 복잡성을 증가시키게 된다. 본 논문에서는 이산시간 상태공간에서의 전상태 관측기를 설계하여 무순단 절체 동작 시 제어기가 요구하는 변수를 추정하고 이를 궤환신호로 사용하여 시스템의 설계 비용 및 복잡성을 줄인다. 또한 계통연계 시 계통유입 고조파 전류를 억제하기 위해 일반적으로 사용되는 기존 공진형 제어기의 과도 응답을 개선하기 위해 이산시간에서 슬라이딩 모드와 공진제어기가 결합된 새로운 제어기 구조를 제안한다. 제안된 기법의 타당성은 PSIM 시뮬레이션을 통하여 입증된다.

  • PDF

Predictive Current Control Method of Single Phase CHFL Converter for EV On-board Charger (전기자동차 온-보드 충전기를 위한 단상 CHFL 컨버터의 예측전류제어 기법)

  • Kim, Seung-Gwon;Kim, Jae-Keun;Park, Sung-Min
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.213-214
    • /
    • 2018
  • 본 논문에서는 전기자동차 온-보드 충전기용 단상 cycloconverter-type high frequency link 컨버터의 전력 제어성능과 동적 응답특성을 개선하기 위하여 예측전류제어 기법을 적용한다. 배터리를 충전 및 방전하기 위하여 전력계통에 연결되는 V2G 충전기는 전압 변동, 고조파 왜곡 등의 외란 발생에도 강인한 동적 응답 특성을 유지하여야 한다. 예측전류제어 기법이 적용된 제어기는 계통 외란이 존재하는 경우에도 전력 레퍼런스를 빠르게 추적하고 정확한 듀티를 생성할 수 있으므로 우수한 동적 및 과도 응답특성을 갖는다. 제안하는 제어기의 성능과 파라미터 변동에 대한 민감도는 PSIM 시뮬레이션을 이용하여 평가되며, 여러 계통외란 상태에서 PI 제어기와 비교된다.

  • PDF

3-Phase Current Estimation of SRM Based on DC-Link Current (직류링크전류를 기반으로 한 SRM 3상전류 추정법)

  • Kim, Ju-Jin;Choi, Jae-Ho;Kim, Tae-Woong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.307-312
    • /
    • 2006
  • This paper proposes the SRM drive system, which accurately estimates the phase currents from the DC-link current to drive SRM instead of detecting the three-phase currents. In addition, the detecting circuit of DC-link current is also proposed to increase the resolution and decrease the off-set influence. Comparing with the general drive system based on the phase current, it is verified through the experiments that the proposed SRM drive system based on the DC-link current has the good performance in steady-state response of the speed control. Using the DC-link current, all of the 3-phase currents can be easily estimated for driving the SRM.

Comparative Study on Classical Control and Modern Control via Analysis of Circuit-based Time Response (회로망 기반의 시간응답 해석에 따른 고전제어와 현대제어의 비교 연구)

  • Min, Yong-Ki
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.575-584
    • /
    • 2017
  • It is suggested the circuit network to analyze the time response of control system. And it is analyzed the interrelation for classical control and modern control by the transfer function and the state equation. Without complicated integration of state transition equation, it is suggested to possible time response by combining the state transition matrix and the transfer function. A source program is coded to display the time response according to the unit-step and the sinusoidal input. Transient response is analyzed in the unit-step input and phase difference between current and voltage is analyzed in sinusoidal input. As writing the suggested contents in transient response or state-space analysis, it is improved the understanding for control engineering and ability for system design.

Performance Evaluation of Thin Film PZT IR detectors in terms of Silicon Substrate Thickness (실리콘 기판 두께에 따른 PZT 박막 적외선 감지소자의 성능 변화)

  • Go, Jong-Su;Liu, Weiguo;Zhu, Weiguang
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.11
    • /
    • pp.781-790
    • /
    • 2001
  • The effects of silicon substrate thickness on the performance of thin film PZT IR detectors are theoretically and experimentally investigated. Theoretical analyses show that the pyroelectric current responsivity of a detector without a silicon substrate is about two orders higher than that of a detector with a 450${\mu}{\textrm}{m}$ thick silicon substrate. At a fixed chopping frequency of 100Hz, the pyroelectric current responsivity decreases exponentially with increasing silicon substrate thickness up to 50${\mu}{\textrm}{m}$, and above 50${\mu}{\textrm}{m}$ the decreasing rate become slow. The thinner the silicon substrate is, the less the thermal loss by conduction is , and thus the higher responsivity is resulted. To verify the theoretical analyses, micromachined PZT thin film IR detectors with different silicon substrate thicknesses are fabricated and characterized. The theoretical and experimental results show the similar tendencies for all silicon substrates with varying thickness.

  • PDF

Characterization of Nafion Coated Non-enzymatic Glucose Sensor in Human Plasma and Whole Blood (나피온을 이용하여 패키징된 무효소 혈당센서의 혈장 및 전혈에서의 특성 평가)

  • Lee, Yi-Jae;Kim, Jung-Doo;Park, Jae-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1474-1475
    • /
    • 2008
  • 본 논문에서는 nanoporous Pt (Platinum) 전극을 이용한 무효소 혈당센서의 생체 적합성 및 전류응답 특성 향상을 위해 다양한 패키징 방법이 제안되었다. 생체적합성을 갖는 Nafion 멤브레인을 dipping, spin coating, chemical bonding 방법으로 패키징 한 후, 다양한 글루코오스 농도의 혈장, 전혈에서 특성을 분석, 비교하였다. 단백질 등이 포함되지 않은 환경에서 spin coating 방법으로 패키징한 센서의 전류응답 특성은 가장 좋았지만, 혈장 및 전혈에서는 dipping, chemical bonding 방법으로 패키징한 센서의 전류응답 특성에 미치지 못했다. Nafion film을 센서와 chemical bonding한 센서의 혈장에서 sensitivity 는 0.32 ${\mu}A/mM{\cdot}cm^2$ 이었다. 한편, 전혈에서 bare 센서가 급격한 bio-fouling 현상을 보이는 반면 패키징한 센서는 글루코오스 농도에 따라 일정한 전류변화를 보였다. 이는 Nafion을 이용하여 패키징한 무효소 혈당 센서가 생체환경에 적합할 뿐 아니라 생체이식형 및 연속 측정 가능한 시스템에 적용 가능함을 보여준다.

  • PDF

An Adoptive Current Control Scheme of an AC Servo Motor for Performance Improvement of a Servo Drive (서보 드라이브 성능 향상을 위한 AC 서보 전동기의 적응형 전류 제어)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.96-103
    • /
    • 2006
  • An MRAC-based adaptive current control scheme of an AC servo motor is presented for the performance improvement of a servo drive. Although the predictive current control is known to give ideal transient and steady-state responses, its steady-state response my be degraded under motor parameter variations. To overcome such a limitation, the disturbances caused by the parameter variations will be estimated by using an MRAC technique and compensated by a feedforward control. The proposed scheme does not require the measurement of the phase voltage unlike the conventional disturbance estimation scheme using observer. The asymptotic stability is proved. The proposed scheme is implemented using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.