• Title/Summary/Keyword: 전류 변압기

Search Result 474, Processing Time 0.046 seconds

Theoretical Analysis of the High Voltage Generator System for CRT Displays (CRT 디스플레이용 고전압 발생기 시스템의 이론적해석)

  • 지철근;박지식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.11
    • /
    • pp.826-835
    • /
    • 1987
  • In this paper, the horizontal output and flyback transformer (FBT) stages during the retrace time are represented by a new simplified equivalent circuit. The circuit analysis is performed by means of this equivalent circuit and the computed results are compared with those of experiment The results show that for fixed other circuit parameters, the high voltage regulation depends upon the coupling factor of transformer, the V-I characteristics and the charge storage of the high voltage rectifying diodes. The computed output voltages are found to be about 3.9 to 5.8% higher than the measurements and these are probably due to the neglection of the transformer losses. These acceptable errors show that the newly suggested equivalent circuit is reasonable.

A Study on the Utilization and Control Method of Hybrid Switching Tap Based Automatic Voltage Regulator on Smart Grid (스마트그리드의 탭 전환 자동 전압 조정기의 다중 스위칭 제어 방법 및 활용 방안에 관한 연구)

  • Park, Gwang-Yun;Kim, Jung-Ryul;Kim, Byung-Gi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.31-39
    • /
    • 2012
  • In this paper, we propose a microprocessor-based automatic voltage regulator(AVR) to reduce consumers' electric energy consumption and to help controlling peak demanding power. Hybrid Switching Automatic Voltage Regulator (HS-AVR) consist of a toroidal core, several tap control switches, display and command control parts. The coil forms an autotransformer which has a serial main winding and four parallel auxiliary windings. It controls the output voltage by changing the combination of the coils and the switches. Relays are adopted as the link switches of the coils to minimize the loss. To make connecting and disconnecting time accurate, relays of the circuit have parallel TRIACs. A software phase locked loop(PLL) has been used to synchronize the timings of the switches to the voltage waveform. The software PLL informs the input voltage zero-crossing and positive/negative peak timing. The traditional voltage transformers and AVRs have a disadvantage of having a large mandatory capacity to accommodate maximum inrush current to avoid the switch contact damage. But we propose a suitable AVR for every purpose in smart grid with reduced size and increased efficiency.

The Development of Electronic Transformer(CT/PT) for Intelligent GIS Based on IEC 60044 (IEC 60044 기반 Intelligent GIS용 전자식 변성기 개발)

  • Kim, M.S.;Jung, J.R.;Kim, J.B.;Song, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2262-2264
    • /
    • 2005
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어지고 있으며, Digital Network에 대응한 변성기 관련규격인 IEC 60044가 근래 제정되어짐에 따라 이에 적합한 전자식 변성기가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 IEC 60044를 기반으로 한 전자식변성기 Layout을 구성하였으며, CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF

An Development of Design Automation Tool for isolated DC-DC Converters (절연형 DC-DC 컨버터의 설계자동화 도구 구현)

  • 김주일;김종태
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.4
    • /
    • pp.101-109
    • /
    • 1999
  • 본 논문에서는 절연형 DC-DC 컨버터의 설계자동화 도구를 제시한다. 절연형 DC-DC 컨버터는 입력과 출력 측의 분리에 의한 회로 보호, 다중출력으로의 확장, 승압 및 강압의 용이성 등의 장점을 가지고 있다. 설계자동화의 과정은 여러 단계로 나눌 수 있다. 토폴로지 선택, 전압 및 전류용량이 적절한 스위치 소자 선택, 인덕턴스와 캐패시턴스의 값 결정, 그리고 변압기 설계의 순서로 컨버터 회로의 자동합성이 진행된다. C언어를 이용하여 자동화 도구를 구현하였고 SMPS 데이터 북으로부터 얻은 실제 회로의 사양을 가지고 다양한 컨버터 회로를 합성함으로 검증하였다.

  • PDF

A Discriminating Algorithm between Magnetizing Inrush and Internal Faults of Transformers Using Difference of a differential current (차동전류의 변화율을 이용한 변압기의 여자돌입과 내부사고 구분 알고리즘)

  • Kang, Y.C.;Lee, B.E.;Yun, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.171-173
    • /
    • 2000
  • This paper presents a discriminating algorithm between magnetizing inrush and internal faults of transformers using difference of a differential current. Incase of inrush, change of magnetizing inductance repeats. Thus, second difference of differential current periodically shows pulse while periodic pulse is not represented in case of internal winding fault. The proposed algorithm is suitable irrespective of the amount of remanent flux.

  • PDF

Transition of voltage-differential current under internal fault on power transformer (전력용 변압기 내부고장시 전압-차전류의 변화에 관한 연구)

  • Park, Jae-Sae
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.92-95
    • /
    • 2004
  • Power transformer is an important apparatus in transforming and delivering the power in a power system. It shows less accident ratio than other system apparatus, but once the accident occurs, it causes long-term operation stoppage and economic loss. It brings high bad spillover effects. Therefore, the role of protective relaying, which is to prevent internal fault a power transformer is highly important. This study proposed advanced algorithm that can clearly determine internal fault of the power transformer and magnetizing inrush, through numerical analysis by using the terminal voltage and input output current.

  • PDF

수전설비의 사례에서 트립사고와 그 체크포인트

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.6 s.102
    • /
    • pp.88-95
    • /
    • 1985
  • 수전설비에서 트립사고의 원인으로서는 전기기기 배전의 고장(단락, 지락)에 의한 것, 과부하의 의한 것 등 당연히 동작해야 될 트립 외에 동작해서는 안될 때에 트립되는 이른바 Nuisance Tripping (불필요동작)이라고 하는 케이스가 있다. 담당 기술자를 곤란하게 하는 현상인데 그 발생요인을 이해해둔다면 대책을 수립하여 방지하는 것은 곤란한 일이 아니다. 과전류에서는 변압기 여자돌입전유가 주로 생각되는데 지로의 경우에는 미소한 사고에너지를 검출, 증폭하고 있기 때문에 몇 가지의 요인을 들수 있다. 여기서는 주로 지로에 의한 요인을 가급적 사례를 기초로 하여 들고 체고 포인트를 설명하기로 한다.

  • PDF

Transformer Temperature forecast method using Top Oil Temperature Rising & Current (최상부 유온 상승과 전류를 이용한 변압기 온도 예측 방법)

  • Ko, Dong-Wook;Kim, Kwang-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1689-1690
    • /
    • 2008
  • In this paper, The method of a temperature rasing forecast is suggested and simulated. The data used in this simulations exists in the KD Power and it was obtain by real transformer. The method of temperature forecast is based on a top oil temperature rising modeling which is proposed by the IEEE journal. We propose modifications of a modeling that accurately predicts a future transformer temperature. This Method is verified by simulations.

  • PDF

Trand analysis of MW grid-connected photovoltaic solar system (MW급 계통연계형 태양광 발전 시스템 동향 분석)

  • Kim, Min-Guk
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.305-306
    • /
    • 2010
  • 현재 전 세계적으로 개발 되어진 계통연계형 태양광 인버터는 500kW급 미만이며, MW급 태양광 발전을 위하여 MW급 인버터 개발이 필요 하지만 파워 반도체(IGBT) 소자의 전류 정격의 한계, 방열 그리고 저주파 변압기의 크기 문제로 개발의 어려움이 있다. 본 논문에서는 이러한 단점을 해결하고 현재 개발 되어 있는 350kW급 태양광 인버터 3대를 이용한 최적의 1MW급 발전 시스템 구성 방향을 제시 하였다.

  • PDF

작은 필터 사이즈를 갖는 고효율의 PWM 3레벨 컨버터

  • Kim, Seon-Tae;Kim, Deok-Yu;Kim, Jae-Guk;Mun, Geon-U
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.131-132
    • /
    • 2010
  • 본 논문에서는 작은 필터 사이즈를 갖는 영전압 스위칭이 가능한 PWM 3레벨 컨버터를 제안한다. 제안하는 컨버터의 모든 스위치의 전압 스트레스는 입력 전압의 반으로 제한되고, 2차측의 필터 앞단 전압이 3레벨 형태로 나타나 기존보다 작은 출력 필터 사이즈가 필요하다는 장점을 갖는다. 또한 두 개의 변압기로 전류를 분할함으로써 도통 손실을 줄일 수 있다. 효과를 확인하기 위해 500-600V 의 입력 전압과 60V 의 출력 전압을 갖는 500W 컨버터를 제작하여 실험하였다.

  • PDF