• 제목/요약/키워드: 전류 변압기

Search Result 474, Processing Time 0.025 seconds

An Improved Feed-Forward Controller for the Parallel Operation of a Single-Phase PWM Converter in High-Speed Trains (고속철도용 단상 PWM 컨버터의 병렬운전을 위한 개선된 전향제어기)

  • Park, Byoung-Gun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.226-234
    • /
    • 2010
  • This paper proposes an improved feed-forward controller that calculates the gain value by estimating the changed boost inductance in practical operating condition of transformer. The boost inductance is estimated by the measurement of input current and voltage. The estimated boost inductance is optimized by the least square method. The proposed feed-forward controller can be achieved the robust control through the gain value calculating the estimated boost inductance despite of the changed condition of transformer and can minimize the interference phenomenon by reducing the harmonics of input current. The validity of proposed technique is verified through the simulation and experiment.

A Study on Hybrid switching Method of Automatic Voltage Control on Smart-greed (스마트그리드에서의 다중 스위칭 방식의 자동 전압 조절 방법에 관한 연구)

  • Park, Gwangyun;Kim, Jungryul;Kim, Byunggi
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.47-50
    • /
    • 2012
  • 본 연구에서는 수용가에서 에너지 절감과 최대수요전력 제어를 위하여 마이크로프로세서를 이용한 고효율 자동 전압 조정기의 제어 방법에 대하여 제안한다. 제안한 고효율 자동 전압 조정기는 트로이달 코아에 1개의 직렬 권선과 분리된 4개의 분로 권선으로 구성되어 있는 단권 변압기를 사용한다. 변압기의 전압 조정은 직렬 권선과 분로 권선의 연결 방법에 따라 감압/승압이 가능하다. 스위치는 릴레이와 트라이악을 병행하여 사용한다. 스위치의 조작 시 발생하는 권선의 여자돌입전류를 제어하기 위하여 트라이악을 이용 연결 상태를 변경하고 연결 상태 유지 시에는 릴레이를 이용함으로써 스위치 소비 전력을 최소화 한다. 제어신호는 여자 돌입 전류를 줄이기 위하여 전압 파형에 동기화 하여 제어되며 이를 위하여 소프트웨어 PLL을 사용한다. 소프트웨어 PLL은 전압 파형의 zero-cross, 전압 최고점 등의 시간을 생성한다. 권선 스위치의 제어, 소프트웨어 PLL등 자동 전압 조정기의 제어는 마이크로프로세서에 의해서 이루어진다.

  • PDF

$(Na,K)NbO_3$ 세라믹스를 이용한 강압형 압전변압기의 전기적 특성

  • Lee, Yu-Hyeong;Ryu, Ju-Hyeon;Kim, In-Seong;Song, Jae-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.94-94
    • /
    • 2009
  • 전기 에너지를 기계적 에너지 변환하고 또한, 기계적 에너지를 전기 에너지로 변환할 수 있는 압전 세라믹스는 압전 변압기 (piezoelectric transformer), 초음파모터, 센서등과 같은 응용분야에 넓게 사용되고 있다. 특히, 압전 변압기의 설계와 제조방법에 대해서는 이미 상당히 많은 연구가 수행되어 왔다. 특히, 전원장치에 있어서는 현재 주요부품으로 사용되고 있는 권선형 변압기와 같은 전자 변환기의 대체품으로서 누설손실이 없는 압전세라믹스 소재의 특성을 이용한 압전변압기의 개발과 응용연구가 국내외적으로 활발히 진행 중이다. 하지만 지금 까지 널리 사용된 PZT계 압전 세라믹스는 환경문제에 있어서 문제점을 가지고 있다. $1200^{\circ}C$ 이상에서 소결되는 PZT계열의 압전세라믹스 소재를 사용한 전자부품의 60~70%이상이 PbO로 구성되어 있기 때문에 $1000^{\circ}C$ 부근에서 급격한 휘발특성을 보이는 PbO로 인한 환경오염문제가 대두되고 있다. 압전변압기, 초음파모터등에 사용될 수 있는 무연계 압전재료 중에 PZT 압전소자의 기능을 대체할 만한 물질로는 높은 큐리온도와 우수한 압전특성을 보이는 $(Na,K)NbO_3$세라믹스가 가장 유력한 것으로 알려져 있다. 즉, 압전변압기용 조성 세라믹스는 높은 에너지 변환효율을 위해서 전기기계 결합계수($k_p$)가 커야 되며, 발열에 의한 온도 상승을 억제하기 위하여 기계적 품질계수($Q_m$)가 큰 것이 바람직하다. 또한, 높은 전류를 발생하기 위해서는 유전상수가 커, 압전변압기의 출력측 정전용량을 크게 하여야 한다. 본 연구에서는 무연계 압전세라믹스를 개발하고, 이를 이용한 전력밀도(power density)가 높은 무연계 압전변압기를 제작하여 그에 대한 전기적 특성을 조사하였다. 따라서 본 연구에서는 무연 압전변압기용 압전 세라믹스를 개발하기 위해 뛰어난 압전 및 유전특성을 가진 무연$(Na,K)NbO_3$계 세라믹스를 기본조성으로 하였고, KCN을 복합 첨가하여 볼 변화에 따른 미세구조, 압전 및 유전특성을 조사하고. 가장 우수한 조성으로 비납 압전변압기를 제작하여 전기적특성을 조사하였다.

  • PDF

Wireless Diagnostic Technique for Pole Transformer Using SMS of Mobile Telecommunication Network (이동통신망의 SMS 방식을 이용한 주상변압기 무선 진단 기법)

  • Kim Jin-Cheol;Lee Hyang-Beom
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.3
    • /
    • pp.61-71
    • /
    • 2003
  • This paper suggests a wireless diagnostic technique using SMS (Short Message Service) of mobile telecommunication network for pole transformer. The temperature and current of pole transformer are acquired and the average and standard deviation are transmitted using SMS of mobile telecommunication network when transformer is overloaded The algorithm and protocol is design to fit the wireless diagnostic technique. By using the wireless method, the weak point of accessability can overcome. It is possible to manage, control, and monitor many transformers with just one server.

  • PDF

A Contactless Power Charging System using Half-Bridge Series Resonant Converter (Half-Bridge 직렬 공진컨버터 적용 비접촉 충전시스템)

  • Kim, Joo-Hoon;Song, Hwan-Kook;Kim, Eun-Soo;Park, Sung-Ho;Kim, Yoon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.251-259
    • /
    • 2009
  • In this paper, a contactless power supply using half-bridge series resonant converter that achieves ZVS operation of main switches and ZCS operation of secondary side diodes is proposed. Since the proposed contactless power supply using half-bridge series resonant converter operates with lower switching frequency than the resonant frequency, it can achieve ZCS operation of secondary side diodes due to discontinuous resonant current. And it is also possible to control the converter in narrow frequency range and to obtain high voltage gain, which, in turn, offers low turns ratio for the transformer and high efficiency. Based on the theoretical analysis and simulation results, the 3.15W prototype is built and the final experimental results are described.

A Study on the Reverse-Power-Flow Phenomenon due to Transformer Wiring Types in Distribution System (배전계통에서 변압기 결선에 의한 역 조류현상에 관한 연구)

  • Shin, Dong-Yeol;Ha, Bok-Nam;Jung, Won-Wook;Cha, Han-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.111-119
    • /
    • 2008
  • As the penetration of distributed generation systems is recently high, there have been metering errors, trips of protective devices in KEPCO distribution systems including an occurrence of false fault-indicator in distribution automation system. The cause of malfunctions was the reverse-power-flow phenomenon due to transformer wiring types. By the effect of the reverse-power-flow, each of phase's fundamental currents was added by about 3 times on the neutral line. A new method based on the analysis of the reverse-power-flow is proposed in this paper. Fault currents on each section were analyzed by the proposed method, and the effect of types of transformer wiring was examined experimentally. In order to reduce the malfunctions due to the reverse-power-flow, controlling the zero-sequence impedance of transformer was designed and verified by using PSCAD/EMTDC software.

Transformerless DGS Control using a Z-source Boost Inverter (Z-원 승압인버터를 이용한 변압기 없는 DGS제어)

  • Park Young-San
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1617-1624
    • /
    • 2006
  • This paper presents system modeling, modified space vector PWM implementation and design of a closed loop controller of the Z-source inverter which consists of L and C components and shoot-through zero vectors for DGS. Zero vector periods of SVPWM utilized to boost DC-link voltage instead of conventional DC/DC converter and transformer. Only two shoot-through vut(nn are used for DC link voltage control during one switching period without loss of non-zero vectors. Discrete time sliding mode controller, robust servomechanism controller are designed to realize fast and no-overshoot current response and a steady state voltage error. Simulation results are shows the effectiveness of the proposed algorithm.

A Single-stage Interleaved Soft-switching On-board Charger with Low Frequency-less Transformer (저주파를 제거한 변압기를 갖는 단일단 인터리브드 소프트스위칭 차량탑재형 충전기)

  • Kim, Minjae;Kim, Byeongwoo;Jung, Bumkyo;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.275-276
    • /
    • 2016
  • 본 논문에서는 저주파를 제거한 변압기를 갖는 단일단 인터리브드 소프트스위칭 차량탑재형 충전기를 제안한다. 기존 단일단과 달리 제안하는 인터리빙 회로와 스위칭 기법으로 변압기의 저주파 리플을 제거하여 코어부피 및 손실을 최적화할 수 있으며 넓은 전압 및 부하영역에서 소프트스위칭을 성취하여 단일단의 문제점을 극복하였다. 또한 인터리빙효과로 인하여 입력필터가 작고 스위치 전류부담을 감소시킬 수 있다. 제안하는 차량탑재형 충전기의 동작원리를 제시하고 시작품을 통해 본 논문의 타당성을 검증하였다.

  • PDF

대화면 PDP 서스테인 파워 모듈을 위한 고효율 펄스폭 변조 컨버터

  • Lee, Il-Un;Jo, Sin-Yeong;Mun, Geon-U
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.366-367
    • /
    • 2011
  • 대화면 PDP 서스테인 파워 모듈을 위한 고효율 펄스폭 변조 컨버터가 본 논문에서 소개된다. 제안된 컨버터는 일차측에서 병렬로 연결되고, 위상 변조 방식으로 구동되는 두 개의 하프브릿지 컨버터로 구성되어 있다. 그들의 변압기들은 이차측에서 직렬로 연결된다. 제안된 컨버터에서 모든 스위치들은 그 전부하 구간동안 ZVS를 가지고 턴 온되며, 동시에 그 ZVS 범위를 확장하기 위해 추가된 전류에 의한 도통 손실을 최소화 할 수 있는 장점을 갖는다. 또한 그 변압기의 턴 비가 비교되는 컨버터들에 비해 유리하게 설계될 수 있어 일차측 도통 손실을 개선할 수 있는 장점도 갖는다. 낮은 프로파일 설계 또한 두개의 변압기의 사용으로 달성된다. 제안된 컨버터의 성능은 80인치 PDP 서스테인 파워 모듈의 스펙으로 구현된 프로토타입 컨버터들부터 검증된다.

  • PDF

A Study on the Harmonics Reduction using Phase Shifting Transformer in a Electric Power Distribution System (배전계통에서 위상조정 변압기를 사용한 고조파 저감에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.38-44
    • /
    • 2002
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system High harmonics current, and voltages will cause equipment damage and disturb the plant operation. The application of phase shifting transformers can be a very cost-effective method of harmonic treatment where multiple harmonic sources ice in operation. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of a phase shifting transformer for harmonic elimination are presented.