• 제목/요약/키워드: 전력피뢰기

검색결과 39건 처리시간 0.03초

전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성 (The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway)

  • 김재문;안승호;김양수;김철수
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

직류전차선로의 뇌과전압 해설 및 피뢰기와 가공지선 차폐효과 검토 (Analysis of Lightning Overvoltage and Shielding Effect of Arrester and Overhead Grounding Wire on DC Railroad)

  • 정채균;홍동석;이종범;조한구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권8호
    • /
    • pp.359-364
    • /
    • 2001
  • This paper presents the influence of the lightning overvoltage and the shielding effect of lightning arresters and overhead grounding wires on the DC railroad systems. Modeling of railroad system is established in ATPDraw to perform the simulation and the line constants of railroad were calculated using ATP_LCC. When a direct lightning strikes to the DC railroad, the result of simulation reveals that the shielding effect of arresters is reduced at messenger, trolly-wire, and the shielding effects of overhead grounding wire is over 90% than the case which does not include it. Therefore it is evaluated that overhead grounding wires should be installed in the DC railroad line.

  • PDF

발전기 및 주변압기 연계 계통의 뇌 서지 영향 분석 (Analysis of Lightning Surge in Interconnected Systems)

  • 박세호;여상민;서훈철;김철환;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.636-637
    • /
    • 2007
  • 전력계통에서 과전압이 발생할 경우 보호 장치들의 트립이 발생하거나 기기들의 영구적인 손상을 가져 올 수 있다. 특히 낙뢰에 의한 뇌 서지는 여러 과전압 중 가장 큰 크기를 가지며, 절연 설계 등에 대해 매우 중요한 현상이다. 특히, 발전기 및 주변압기가 연계된 계통에서의 뇌 서지는 피뢰기의 위치 선정, 각종 제어 회로에의 영향 등의 관점에서 검토되어야 할 대상이다. 본 논문에서는 과도해석 프로그램인 EMTP-RV를 이용하여 발전소 및 주변압기 연계 계통을 모델링하고, 낙뢰에 의한 과전압이 송전선로에 발생하였을 때 발전기 및 주변압기연계 계통에서 어떻게 영향을 미치는지 모의하고 분석하였다.

  • PDF

양성자 가속기 연구센터 관련 전력설비 설계 현황 (Electric Power System Design Status for the Proton Accelerator Conventional Facilities of PEFP)

  • 문경준;전계포;민의섭;남정민;김준연;김보현;정우성;유석태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.496-497
    • /
    • 2006
  • 90년대에 들어서면서부터 미래원천기술 개발에 필요한 양성자원 및 중성자원의 중요성이 부각됨으로써, 이에 적합한 고에너지(수백 MeV${\sim}$수 GeV) 및 대전류(수십 mA)의 대형 양성자 가속기가 개발되어 반도체 생산, 의료장비 등 여러 분야에 널리 적용되고 있는 추세이다[1, 2]. 이에 양성자 사업단은 21세기 미래 원천기술을 개발하고 산업경쟁력을 제고하며 공공복지를 증진시킬 수 있는 양성자가속기를 개발하여, NT, BT, IT, ST등 중요 국가과학기술분야의 발전기반을 확충하기 위한 프론티어 사업목표로 하고 있으며 이에 부응할 수 있는 양성자 가속기 연구센터 건설계획을 설정하여 추진 중에 있다. 본 논문에서는 양성자 가속기 연구센터 건설계획 과정 중에서 전력설비 설계 방법, 즉 154kV 수전 설비, 직류전원계통, 무정전 전원계통 설비, 접지 및 피뢰설비의 기능 및 특징에 관해 기술하고자 한다.

  • PDF

선화아연바리스터 기반의 1-포트 서지보호장치의 최적 설계 기법 (Optimal Design Method of 1-Port Surge Protective Device Based on Zinc Oxide Varistor)

  • 정태훈;김용성;박근보;이승일
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.93-102
    • /
    • 2018
  • 본 논문은 뇌격전류에 따른 저압 배전계통의 전자식 전력량계 및 배전 패널의 통신설비와 전원장치를 보호할 목적으로 사용하는 서지보호장치(SPD)에 관한 것이다. 서지보호장치(SPD)는 접속방식에 따라 1-포트 서지보호장치(SPD)와 감결합 요소를 포함한 2-포트 서지보호장치(SPD)로 구분된다. 뇌격전류에 대한 내부 시스템의 보호는 협조된 서지 보호체계를 이루는 계통적인 접근이 필요하다. 이에 대응하기 위해 이론적인 검토를 통해 피뢰구역(LPZ) 정의에 대한 고찰 및 해석을 진행하였다. 뇌서지에 의한 뇌격전류는 상당히 크기 때문에 하나의 서지보호장치(SPD)로 방호하기에는 한계가 발생하며, 이를 해결하기 위해 다단의 종속적으로 서지보호장치(SPD)를 설치하게 된다. 본 논문에서는 전력계통에 있어 한전계통에 연계되는 Incoming side가 아닌 건물 내에 설치되는 분기형 배전패널 내부의 전자식 전력량계 및 각종 통신(제어)설비를 보호할 목적으로 한전계통이 연계되는 MOF 단에 설치되는 LPZ0에 해당하는 피뢰기(LA, SA)와 보호협조를 이루는 LPZ1과 LPZ2의 경계영역에 설치하는 저압 배전계통용 II등급 서지보호장치(SPD)에 대해 설계를 하였다. 또한 감결합 요소가 없고, 부하 전류를 흘릴 수 있는 직렬 접속 방식의 1-포트 서지보호장치(SPD)에 대한 최적의 설계 방안을 도출하고 실험을 통해 기존의 방식과 비교하여 성능 개선과 관련한 검증을 실시하였다.

전력용 피뢰기의 열안정화 특성 (Study on Thermal Stability Characteristics of Surge Arrester for High Power)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1142-1145
    • /
    • 2004
  • ZnO surge arresters continuously endure the operating voltages during the operation course, and in the mean time, which need to withstand occasionally transient voltages of lightning and switching overvoltages. Under these voltages, the ZnO varistors inside arresters would have aging phenomena, one important result of aging phenomena is the increasing of resistive currents of varistors, which leads to the increasing of power losses of varistors. And the operating voltage is continuously applied on the ZnO varistors, there is a degradation phenomenon existing in ZnO varistors. When the degradation reaches a certain degree, then the arrester must stop operation. The degradation is related to the applied voltage ratio, the applied voltage ratio is high, the degradation is quickly. When the power loss is higher than the thermal dispersion ability of house of arrester, then the arrester will thermally breakdown. In this study the thermal stability characteristics of surge arresters for high power wil be discussed on the view point of watt losses and thermal breakdown.

  • PDF

누설전류 검출에 의한 ZnO 피뢰기의 열화진단장치 개발 (Development of a Deterioration Diagnostic Device for ZnO Arrester by Leakage Current Detection)

  • 김재철;이보호;오정환;이영길;문선호;김영춘
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.184-189
    • /
    • 1999
  • In this paper, we develope a diagnosis device for ZnO arrester by detecting the leakage current in service. To diagnose the deterioration of ZnO arrester, the device detects the total leakage current which flows between an arrester and ground, and analyzes the resistive current(third harmonic current) which is an indicator of deterioration of ZnO arrester. We use the optical cable which can transfer a detected data without a noise, also use a microprocessor for a data storage, processing, and trend analysis. Experiment are executed to verify its performance in laboratory and the results show that the diagnosis device exactly detects the total leakage current and the resistive current, so it can diagnose the deterioration of ZnO arrester. Also the leakage current of ZnO arrester is detected using the developed diagnostic device in field, these results are presented.

  • PDF

전력용 피뢰기의 MOV 미립화와 에너지 내량 특성 연구 (Study on Surge Absorption Capability for Power Arrester with MOV Micro-milling Characteristics)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.120-124
    • /
    • 2004
  • The protection performance and energy absorption capability are important for both MOAs for distribution lines and MOAs for high voltage systems, therefore the manufacturing technique of ZnO varistor elements with high ability against surge impacts is great important for high voltage systems. But until now ZnO varistors for low voltage class have been developed in Korea, ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems depend on an import from advanced countries, such as Japan or U.S.A, which have developed its in the late 1980s. So in the aspect of taking independent technique the development of ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems is important. In this research project ZnO varistor elements with diameters of 35mm and 70mm for the rate discharge current of 5, 10kA class for high voltage systems are manufactured, then various chemical composition and processing variables affected the electrical and the physical characteristics of these ZnO varistors are investigated.

  • PDF

산불 방지를 위한 산악기상관측시스템 구축방안 (A Study on Establishment of the Optimum Mountain Meteorological Observation Network System for Forest Fire Prevention)

  • 이시영;정일웅;김상국
    • 한국농림기상학회지
    • /
    • 제8권1호
    • /
    • pp.36-44
    • /
    • 2006
  • 본 연구에서는 강원 영동 및 경북 동부지역의 산악기상관측시스템 구축을 위한 AWS 위치선정, 네트워크 구성(관측시스템, 통신시스템, 자료처리시스템)과 특히, 산불방지를 위해 산림청과 지방자치단체가 기 설치한 산불무인감시카메라, 무선중계탑의 산악기상관측망과의 연계 구축방안과 산악기상관측망의 관리방안을 제시하였으며, 본 연구를 통해 얻어진 사항은 다음과 같다. 산지가 많은 강원도에서는 산악지형에 따른 악기상이 자주 발생하여 강원지방기상청에서는 관측망을 유지관리 하는데 고초를 겪고 있으며 강풍, 뇌전현상 등으로 장비피해를 많이 입어, 보다 피해를 최소화할 수 있는 여러 가지 방안들을 강구하여 왔다 따라서 산악지형에 관측망을 구성하기 위해서는 장비의 견고성을 최우선적으로 반영해야 한다. 전원시설은 가능한 태양전원을 권장하지만 일조량이 적은 깊은 계곡과 같은 지역에 설치가 이루어질 경우 상용전원을 사용할 수밖에 없으며 대부분 산악에서의 전원시설은 열악하여 전원 백업시설 설치를 강구해야 한다. 전원 백업시설의 효율성을 유지하기 위해서는 소비전력이 적은 시스템을 선택하여 관측자료의 손실을 최대한 방지해야만 한다. 또한 태양전원을 이용할 경우 충전과 소모량을 사전에 면밀히 검토해야 한다. 산악은 뇌전현상이 근접하고 잦기 때문에 뇌전으로부터 장비 보호시설 설치를 강구하기 위해 피뢰접지 및 장비접지 시설에 투자를 아껴서도 안 될 것이다. 뇌전으로부터의 장비 보호시설을 강구하는 것도 중요 하지만 써지에 강한 제품을 채택하는 것이 보다 중요하다고 하겠다. 자료수집에 있어서는 전원 및 통신환경을 감안하여야 하며 전체 통신망을 단일화하는 것도 간결하지만 단일 통신망만을 채택할 경우에는 한계성이 있으므로, 다양한 통신망을 이용하는 것이 자료수집의 한계를 극복할 수 있는 방법이다. 따라서 수집 통신망을 통한 기상 관측 자료를 인근 1차 수집기관을 거쳐 최종 메인 수집장치로 내부망을 따라 수집하는 것이 최선의 망 운영방법이다. 자동관측시스템(AWS) 설치 시 기존의 무인감시카메라와 무선중계탑을 최대한 활용하되 무인감시카메라 설치위치$(70\siml,245m)$와 무선중계탑의 설치위치 $(299\sim1,573m)$가 산불위험지역에 포함되어 있는지의 면밀한 검토가 요구된다. 산불 등 각종 산림재난 방지와 관련한 정보를 얻을 수 있는 자동기상관측시스템(AWS)의 설치 위치는 산불발생확률모형에서 산정된 위험지역 내에 설치하는 것이 산불발생 위험지역을 판정하는데 매우 효과적일 것으로 판단된다. 기상청과 지자체가 보유하고 있는 기상관측 장비들은 대부분 도시를 중심으로 설치 운영되고 있어 산림 또는 산악에 설치된 기상관측 장비의 수는 적은 편이다. 따라서 산림과 산악에 기상관측 장비의 보강은 필수적이다. 관측망 구성은 기상청의 관측 표준(안)을 준수하며, 설치 지점의 특성에 따라 가장 경제적인 방법을 선택하는 것이 바람직하며, 특히 장비구매 설치 시 다양한 종류의 제품을 선택하는 것은 차후 장비 관리에 어려움을 겪을 소지가 있어 가능한 우수한 제품을 선택하되 동일 제품 사용을 권장한다. 따라서 위의 망구축이 이루어져 현재 기상청이 설치 운영하고 있는 측정 장비에 의해 취득한 기상자료를 공동 활용하여 표출하면 더욱 상세한 자료의 획득과 활용이 기대되어 진다. 또한, 금번 논문에서는 산불위험지역의 격자점(15km)내에 최소한 1대의 AWS 설치방안을 제시하였지만, 금후에는 15km내에서도 능선, 계곡 등 구체적인 위치확정을 위한 선행연구가 실시되어야할 것으로 판단된다.