• Title/Summary/Keyword: 전력절약

Search Result 509, Processing Time 0.033 seconds

Autonomous Indoor Lighting Device Control System Based on Wireless Sensor Network (무선센서네트워크 기반의 자율 실내 조명 제어 시스템)

  • Islam, Tahidul;Koo, In-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.31-38
    • /
    • 2011
  • In this paper, we propose an autonomous Indoor lighting control system in which indoor lighting devices are autonomously controlled such that electricity bills are minimized in our daily life. Our focus is to utilize Passive Infrared (PIR) sensors to detect the presence of human being indoor and automatically to control indoor lighting electric devices. A control algorithm is also devised to control the whole system. We justify the proposed system by demonstrating specific applications in our everyday life. Cost survey and experimental results also demonstrate the efficiency of the proposed system in real life.

Design and Implementation of Optimal Control Algorithms for Building Energy Management (빌딩 에너지 관리 최적화 알고리즘 설계 및 구현)

  • Jin Jung-Hwa;Chung Sun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

Energy Effective Tag Anti-collision Protocol for Mobile RFID System (에너지 효율적인 모바일 RFID용 태그 충돌방지 프로토콜)

  • Cho, Yang-Hyun;Kook, Joong-Gak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.2
    • /
    • pp.207-214
    • /
    • 2012
  • This paper is to improve an identification ratio of tags by analyzing Slotted ALOHA, Dynamic Slotted ALOHA, Binary-tree and Query-tree and shortening the tag identification time in mobile RFID. Also, it enables the stable information transmission of tags by saving backscattering power of tags through shortening of identification time. As a result, this increases the available time of the battery and accessibility to a RFID service. For this, we proposed the energy-efficient tag anti-collision protocol for mobile RFID. The proposed scheme shows advanced result in identification time and collision counts. This scheme may be the first attempt for the mobile anti-collision.

File System Featured FAT Compatible Flash Translation Layer (파일시스템 기능을 지원하는 FAT 호환 플래시 변환 계층)

  • Kim, Yumi;Baek, Seungjae;Choi, Jongmoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.04a
    • /
    • pp.699-702
    • /
    • 2009
  • 저 전력, 내구성, 소형, 빠른 속도 등의 장점을 가지고 있는 플래시 메모리는 생산 기술 발전에 힘입어 센서 노드, 휴대폰, MP3, PMP등의 소형 전자 제품의 저장장치에서부터 SSD형태로 노트북이나 서버에 이르기 까지 그 활용범위가 더욱 확장되어 가고 있다. 다양한 시스템에서 사용될 수 있는 플래시 메모리의 특성상 이에 저장된 데이터의 호환성은 중요한 고려사항이다. 이를 위해 플래시 메모리의 고유한 특성을 숨기고 일반적인 블록장치로 에뮬레이션 해주는 소프트웨어인 FTL과 FAT 파일시스템이 플래시 메모리 관리를 위한 사실상 표준 소프트웨어로써 사용되고 있다. 그러나 범용 컴퓨터를 기반으로 개발된 FTL과 FAT 파일시스템을 열악한 하드웨어로 구성된 시스템에서 구동하는 경우 많은 제약이 발생한다. 따라서 본 논문에서는 이러한 제약사항을 극복하기 위해 최소한의 파일시스템 기능을 제공하는 FAT 표준 호환 FTL을 제안한다. 제안된 기법은 리눅스 운영체제에 동적으로 적재 가능한 모듈형태로 구현되었으며, 실험을 통해 본 논문에서 제안한 기법이 기존 기법 대비 32%의 메모리 공간을 절약할 수 있으며, 동시에 완벽한 FAT 호환성을 제공함을 확인할 수 있었다.

A method of SW development cost estimation for SBA's cost-effectiveness analysis (SBA 효과도 분석을 위한 소프트웨어 개발 비용 산정기법 연구)

  • Choi, Dal-Nim;Kim, Hyung-Jong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.337-339
    • /
    • 2011
  • M&S 기반의 가상환경 설계운영은 자원절약 및 위험성 감소 등 다양한 측면에서 효율성을 지니고 있다. 국방은 현실세계에서 실시하기 어려운 군사작전 시뮬레이션 운영을 위해 국방 M&S 개념을 도입하고, 이를 기반으로 무기체계의 소요도출부터 전력화 단계까지 프로세스 전반에 걸쳐 가상 환경에서의 설계 운영 및 검증을 수행하는 SBA 를 도입하였다. 그러나 모델링 및 시뮬레이션 과정에서 발생되는 고비용, 위험성 등의 문제점은 SBA 도입 효율성에 대한 논란의 요인이 된다. 따라서 SBA 도입 효과를 입증할 수 있는 지표 제시가 요구되며, 이 연구에서는 입증 지표로서 비용, 시간, 품질 및 위험도의 4 가지 요소를 분석한다. 또한 소프트웨어 개발비용 산정의 어려움 및 SBA의 고비용 가능성을 이유로 SBA 에 대한 개발비용 산정의 필요성을 제기한다. SBA 개발비용 산정을 위해 기존에 제시된 소프트웨어 개발비용 산정 모델 적용을 제안하고, COCOMO 모델, Putnam 모델, FP모델, 전문가의 감정 및 델파이 기법 등 소프트웨어 개발비용 산정모델을 기반으로 SBA 개발비용 산정에 적합한 모델을 분석한다.

An Application-Specific and Adaptive Power Management Technique for Portable Systems (휴대장치를 위한 응용프로그램 특성에 따른 적응형 전력관리 기법)

  • Egger, Bernhard;Lee, Jae-Jin;Shin, Heon-Shik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.8
    • /
    • pp.367-376
    • /
    • 2007
  • In this paper, we introduce an application-specific and adaptive power management technique for portable systems that support dynamic voltage scaling (DVS). We exploit both the idle time of multitasking systems running soft real-time tasks as well as memory- or CPU-bound code regions. Detailed power and execution time profiles guide an adaptive power manager (APM) that is linked to the operating system. A post-pass optimizer marks candidate regions for DVS by inserting calls to the APM. At runtime, the APM monitors the CPU's performance counters to dynamically determine the affinity of the each marked region. for each region, the APM computes the optimal voltage and frequency setting in terms of energy consumption and switches the CPU to that setting during the execution of the region. Idle time is exploited by monitoring system idle time and switching to the energy-wise most economical setting without prolonging execution. We show that our method is most effective for periodic workloads such as video or audio decoding. We have implemented our method in a multitasking operating system (Microsoft Windows CE) running on an Intel XScale-processor. We achieved up to 9% of total system power savings over the standard power management policy that puts the CPU in a low Power mode during idle periods.

Feedstuff of Food Garbage by the Rapid Steam Drying (스팀 고속건조에 의한 음식물쓰레기의 사료화에 관한 연구)

  • Kim, Nam-cheon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.3 no.2
    • /
    • pp.69-78
    • /
    • 1995
  • When the food garbage of general hospital was dried by the rapid steam drying process, the water content was changed to 1.3% from 77.8~82.8%. In this experiment, weight reduction rate was 80%, and electricity consumption was 2.4Kwh. Dried compost from this rapid steam drying process was brown pellets, which was consist of 27.77% crude protein and 3.19% crude fiber. Even though these pellets were slightly short of crude fat and crude ash content, these were analysed as a possible supplementary feed for pig. On the condition of drying food garbage mixed with 5% pulverized chaff, the necessary drying time was shortened by 1 hour, weight reduction rate was 76%, and reduction rate of electricity consumption was 42%. But contents of crude fiber and crude ash were increased to about 2 times. In case of adding new food garbage continuously to the composted food garbage mixed with 3.4% pulverized chaff, weight reduction rate and contents of crude fiber and crude ash were decreased gradually, but contents of crude protein and crude fat were increased. In case of composting food garbage from buffet, both drying time and electricity consumption were reduced, and ingredients of compost were higher than that of assorted feed for pig in the market.

  • PDF

조광기능을 갖춘 전자식 형광등용 IC

  • 최낙춘;신동명;김덕중
    • 전기의세계
    • /
    • v.43 no.1
    • /
    • pp.13-19
    • /
    • 1994
  • 전자식 안정기는 최근 에너지 절약 정책과 관련하여 조명기기분야의 관심의 대상이 되었고, 절전 효율이 높은 고품질의 전자식 안정기에 대한 연구 개발 및 보급이 점점 더 확대되고 있는 추세이다. 일반적으로 전자식 안정기는 수십 KHz의 고주파에서 형광등을 구동시킴으로써 빛의 깜박거림과 가청잡음이 없으며, 저주파(60Hz)에서 사용하는 재래식 안정기(choke coil 방식)에 비해 높은 절전 효과를 얻을 수 있다[1-4]. 특히, 빌딩 사무실의 경우 낮에도 창가의 형광등이 켜져 있어서 막대한 전력을 낭비하고 있는 실정이므로, 일조량에 따른 자동 전력 조절이 가능한 전자식 형광등의 출현이 기대되고 있다. 전자식 안정기의 보급 확대를 위해서는 절전 효과 뿐만 아니라, 품질 문제, 수명 문제등을 고려하여야 하는 바, 예를 들면 순간 점등으로 방전초기의 sputtering 현상에 의한 lamp의 수명 단축, 미소 입력전압 변동에 따른 급격한 광출력의 변화로 절전 효과의 상실과 이상동작에 의한 스위칭 소자의 파괴 현상, 고주파 스위칭시 발생되는 전력손실과 noise등에 대한 대책이 요구되고 있다. 이러한 점을 개선하기 위해 추가되는 회로는 전자식 안정기 시스템을 더욱 복잡하게 만들고, 경제적으로 원가 부담을 주기 때문ㅇ 고품질의 전자식 안정기를 보급하는데 어려운 점으로 부각되고 있다. 본 고에서는 이러한 문제를 해결하기 위하여 조광기능을 포함한 다양한 제어회로와 보호회로를 조광기능을 포함한 다양한 제어회로와 보호회로를 1 chip에 수용하는 고품질의 전자식 안정기 제어용 집적회로에 대해서 기술하고자 한다.되어 나아갈 기술의 조류에도 부합하는 형태라 하겠다. 그러나 이 방식은 기 언급한 바와 같이 분산처리를 관장하는 운영체계의 개발에 상당한 고전이 따르리라 보여지며, 또한 보다 상세한 연구가 선행되어야 하겠지만 개발된 상용의 통신 프로토콜로서는 병렬처리의 성능을 극대화 하기에는 여러가지 제약이 있을 것으로 예측된다.기기들이 어떻게 응용되고 있는지 살펴보기로 하자. real informations would be available. Results are compared with those of optimal power flows.기능시험을 완료했으며 실제 line-of-sight(LOS) 시스템 구현에 적용중이다. 시대를 살아 갈 회원들이다. '컨텐츠의 시대'가 개막되는 것이며, 신세기통신과 SK텔레콤은 선의의 경쟁 과 협력을 통해 이동인터넷 서비스의 컨텐츠를 개발해 나가게 될 것이다. 3배가 높았다. 효소 활성에 필수적인 물의 양에 따른 DIAION WA30의 라세미화 효율에 관하여 실험한 결과, 물의 양이 증가할수록 그 효율은 감소하였다. DIAION WA30을 라세미화 촉매로 사용하여 아이소옥탄 내에서 라세믹 나프록센 2,2,2-트리플로로에틸 씨오에스터의 효소적 DKR 반응을 수행해 보았다. 그 결과 DIAION WA30을 사용하지 않은 경우에 비해 반응 전환율과 생성물의 광학 순도는 급격히 향상되었다. 전통적 광학분할 반응의 최대 50%라는 전환율의 제한이 본 연구에서 찾은 DIAION WA30을 첨가함으로써 성공적으로 극복되었다. 또한 고체 염기촉매인 DIAION WA30의 사용은 라세미화 촉매의

  • PDF

Adaptive Minimum Sleep Window Algorithm for Saving Energy Consumption in IEEE 802.16e (IEEE 802.16e에서의 에너지 절약을 위한 적응적 최소 수면 구간 결정 알고리즘)

  • Jung, Woo-Jin;Lee, Tae-Jin;Chung, Yun-Won;Chung, Min-Young
    • Journal of Internet Computing and Services
    • /
    • v.9 no.4
    • /
    • pp.11-20
    • /
    • 2008
  • IEEE 802.16e has adopted sleep mode to minimize energy consumption of mobile nodes with high speed mobility. If the Base Station (BS) has no data to be sent to a Mobile Subscriber Station (MSS) at the instant of ending sleep window of the MSS, the MSS increases its sleep window interval by double until the window interval reaches to the maximum sleep window interval. Thus, during the operation of sleep mode, MSS repeatedly performs switch on/off action until there exist frames to be received from BS. The switch on/off operation significantly consumes energy of MSS. To effectively deal with the energy of the MSS, this paper proposes an algorithm which decides the minimum sleep window interval that will be used in next sleep mode based on the current sleep window interval. We evaluate the performance of IEEE 802.16e sleep mode algorithm and our proposed algorithm in terms of energy consumption and blocking probability. Compared with the current sleep mode algorithm used in IEEE 802.16e, the proposed algorithm decreases the energy consumption by about 30% without increasing blocking probability.

  • PDF

Analysis of the abroad and domestic research trends on climate change and its economical effect on the power plant (기후변화협약 시행에 따른 대응 방안 및 발전분야 영향 분석)

  • Woo, Kwangje;Hwang, Jae Dong;Jeong, Seok Yong;Jang, Gil Hong
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.43-49
    • /
    • 2001
  • To meet $CO_2$ emission regulation, this study describes the present state of $CO_2$ reduction technology and the effect of the regulation on power industry. In Japan, R&D investment is actively continuing through a long-term R&D project, along with trying to meet the reduction demand by the ways of energy saving and abroad business. EU has made a lot of investments in increasing the efficiency of power generation and developing alternative energy sources. The US is making provision of the portion of reduction by using energy saving program and emission trading, and the current DOE-driven program is addressing the development of cost-effective power systems. In the country, the research to reduce $CO_2$ emission has been mainly driven by the government and research institute supported by the government. Meanwhile, if the reduction obligation imposed on Portugal which is the least strict condition will be enforced in Korea, it is likely that about 50 running power plants should be stopped or shut down after 2015, in spite of voluntary reduction efforts such as conversion to clean fuels, etc. according to the government's long-term electric power need and supply plan.

  • PDF