• Title/Summary/Keyword: 전력절약

Search Result 509, Processing Time 0.025 seconds

Photovoltaic Generation System Control Using Space Vector PWM Method (공간벡터 PWM 방식을 이용한 태양광 발전 시스템 제어)

  • Cho, Moon-Taek;Choi, Hae-Gill;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.31-37
    • /
    • 2010
  • In this paper, a photovoltaic system is designed with PWM(Pulse Width Modulation) voltage source inverter. Proposed synchronous signal and control signal was processed by 56F8323 microprocessor for stable modulation. The PWM voltage source inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power, from 10 to 20[%]. The PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. In addition, I connected extra power to the system through operation the system voltage and inverter power in a synchronized way by extracting the system voltage so that the phase of the system and PWM voltage inverter can be synchronized. In the system of this research showed good results after being controlled in order to provide stable power to the load and the system through maintaining and low output power of harmonics.

An Efficient Voltage Scheduling for Embedded Real-Time Systems with Task Synchronization (태스크 동기화가 필요한 임베디드 실시간 시스템에 대한 효율적인 전압 스케쥴링)

  • Lee, Jae-Dong;Hur, Jung-Youn
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.6
    • /
    • pp.273-283
    • /
    • 2008
  • Many embedded real-time systems have adopted processors supported with dynamic voltage scaling(DVS) recently. Power is one of the important metrics for optimization in the design and operation of embedded real-time systems. We can save considerable energy by using slowdown of processor supported with DVS. In this paper, we propose heuristic algorithms to calculate task slowdown factors for an efficient energy consumption in embedded real-time systems with task synchronization. The previous algorithm has a following constraint : given the tasks are ordered in a nondecreasing order of their relative deadline, the task slowdown factors computed are in a nonincreasing order. In this paper, we relax the constraint and propose heuristic algorithms which have the same time complexity that previous algorithm has and can save more energy. Experimental results show that the proposed algorithms are energy efficient.

Analysis of the Hardware Structures of the IoT Device Platforms for the Minimal Power Consumption (소비 전력 최소화를 위한 IoT 디바이스 플랫폼의 하드웨어 구조 분석)

  • Lee, Jin
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.2
    • /
    • pp.11-18
    • /
    • 2020
  • Since the end devices of the Internet of Things (IoT) are battery operated products, careful consideration for ultra-low power (ULP) is required. The Micro Controller Unit (MCU) industry has developed very effective functions to save energy, but developers have difficulty in selecting the MCU because various operating modes are applied to reduce energy consumption by manufacturers. Therefore, this paper introduces ULPMark benchmark, a standardized benchmark method that can compare MCUs of various vendors and feature sets, and provides hardware functions for ultra-low-power operation of the two platforms that received the high evaluation scores from ULPMark. In addition, we investigated and analyzed how developers can utilize the functions for ultra low power consumption through driver APIs and detailed register control.

Studies on the Application of Unit-inverter Parallel Operation to Sea-water Lift Pump in Power Plant (단위 인버터 병렬운전에 의한 발전소 해수펌크 적용)

  • 김수열;류홍우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • Due to the increase in capacity of auxiliary machinery in power plant, the importance of energy saving has been greatly emphasized. If the speed of fans or pumps is controlled in accordance with the variation of load, large electric energy can be saved. Large capacity inverter, 2MVA GTO inverter, has been developed by operating two of 1MVA unit inverters in parallel. The parallel operation of the unit inverter is accomplished through two output transformers of which the secondary windings are connected in series. The system is composed of one control cubicle, one rectifier cubicle and 2 unit inverter cubicles. This inverter system was applied to the sea water lift pump(SLP) driven by a 6.6KV 1500KW induction motor in Seo-Inchon power plant to save the electric energy. The parallel operation of inverters by 180 degrees apart in switching frequency helps to reduce the harmonic components.

A Study on the CO2 Reduction Potential by Means of Increased Efficiency of the Electricity (제조업 전력 사용 효율성 제고를 통한 온실가스(CO2) 감축 잠재량 추정에 관한 연구)

  • Min, Dong-Ki
    • Journal of Environmental Policy
    • /
    • v.9 no.3
    • /
    • pp.143-160
    • /
    • 2010
  • This paper estimate the $CO_2$ reduction potential that can be achieved by improving the technical efficiency of input factors in the manufacturing sector. Technical efficiency in each manufacturing firm was estimated using the DEA technique. Depending on the returns-to-scale assumption selected, average technical efficiency was estimated to be between 0.467 and 0.643. These estimates suggest that, when the efficiency of electricity consumption in the manufacturing sector is improved, the overall $CO_2$ emissions can be reduced by 17.1-25.5%. Recently, the Korean government has adopted a low-carbon-green-growth policy with the goal of reducing greenhouse gas emissions by 30% below the BAU level by year 2020. The analysis of the paper suggests that this goal can be achieved through improved efficiency of electricity consumption.

  • PDF

Power Demand Estimation of Consuming Facility using Orthogonal Polynomial Regression Model (직교 다항 회귀모델을 이용한 수용설비의 소비전력 추정)

  • 고희석;이충식;지봉호;김일중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.75-81
    • /
    • 1999
  • This paper presents in the rrethod power demand estimated of consuming facility algorithm using orthogonal polynomial regression rmdel. Estimation rmdel presented can use mathematical rrethod consists. of extrapolation and correlation rrethod, Computation tirre and capacity of presented rmdel was rmre economic than multiple regression rrodel because low-order equation can use in the high-order equation without sorre correction, and vice-versa. Therefore this rmthed can be very usefulness rmthed in the power demand estimation Fourth-order rrodel was very good armng this rrodel that was coJTJp)Sed the estimation rmdel of second, third and fourth-order. Power demand estimated result of consuming facility using correlation rrethod was good in the percentage error of about 2[%1 Also It was to verify efficiency and awroPJiation the estimated rmdel that estimation percentage error was about 1[%] in the oower demand estimated result of 1997.

  • PDF

A Study on Energy-Saving of Neon Sign by ON/OFF Control (네온사인의 점멸에 의한 전기에너지의 절약에 관한 연구)

  • 김인식;김성수;이동인;이광식
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.3
    • /
    • pp.27-35
    • /
    • 1994
  • As a study on the method for energy-saving of the neon sign, this paper has systematically investigated the quantity of energy-consumption of the sign through a long period of time, according to the changes of the sign's ON/OFF speed, time ratio, etc. One neon sign(1 [kW] was built up for this. For this experiment, the ON/OFF periods(T) were set to 1.0,2.0,4.0 and 8.0[sec), and the ON time ratios(D) to 25, 50, 75 and 100 [%] respectively. Energy Analyzer was used for more accurate measurement. As the result, we found that the energy consumption of the sign had no effect on the ON/OFF period (T) when T was more than 2.0(sec), but that the energy consumption was decreasing when T was less than 2.0[sec]. The greatest value in the energy-saving of the sign appeared when the values of T and D were small altogather. And under the conditions, the energy consumption with T=1.0[sec) and D= 25[%] decreased 83.0[%] in comparison with the continuous ON case.

  • PDF

A operation scheme to the power consumption of base station in wireless networks (무선망에서 기지국의 전력소모에 대한 운영 방안)

  • Park, Sangjoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.285-289
    • /
    • 2020
  • The configuration of hierarchical wireless networks is provided to support diverse network environments. In the base station, two system state can be basically considered for the operation management so that the state transition may be occurred between active and sleep modes. Hence, to reduce energy consumption the system operation management of the low power should be considered to the base station system. In this paper we consider the analytical model of Discontinuous Reception (DRX) to investigate the system management. We provide the analysis scheme of base station system by the DRX model, and the low power factor would be investigated for the energy consumption. We also use the finite-state Markov system model that in a system state period the wireless resource request and the operation of service call arrival interval is considered to numerically analyze the performance of energy saving operations of base station.

A Dynamic Server Load Balancing based on Power Information for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 전력 정보 기반의 동적 서버 부하분산)

  • Kim, Dong-Jun;Kang, Na-Myong;Kwon, Hui-Ung;Kwak, Hu-Keun;Kim, Young-Jong;Chung, Kyu-Sik
    • Annual Conference of KIPS
    • /
    • 2011.04a
    • /
    • pp.171-174
    • /
    • 2011
  • 서버 클러스터에서 부하 분산기는 사용자의 요청을 각 서버로 분산시키는 역할을 한다. 리눅스 가상 서버(LVS: Linux Virtual Server)는 소프트웨어적으로 사용되는 부하 분산기로서 여러 가지 스케줄링 방식들을 가지고 있다. 그러나 부하 분산 시에 서버의 유동적인 부하 정보를 반영하지 못하는 단점이 있다. 이에 개선된 방식으로 서버의 동시 연결 개수에 따라 상한계(Upper Bound)와 하한계(Lower Bound)를 설정하고, 요청을 분산하는 동적 스케줄링(Dynamic Scheduling)이 존재한다. 그러나 서버의 상태에 따라 상한계와 하한계가 바뀔 수 있음에도 불구하고 이 값들이 고정되어 있다는 단점을 가진다. 본 논문에서는 기존 부하 분산 방법의 단점을 극복하는 서버 전력 정보에 기반한 스케줄링 방식을 제안한다. 제안된 방식은 서버의 부하 정보를 기반으로 에너지를 추정하고 전력 수치를 기반으로 LVS의 가중치 테이블을 주기적으로 갱신한다. 그리고 부하 분산기는 클라이언트로부터 요청 받은 트래픽을 각 서버의 에너지 소모 상태에 따라 적용시킴으로써 에너지 소모가 최소화되도록 부하를 분산한다. 또한 서버의 상태에 따라 상한계와 하한계가 바뀔수 있음을 고려하여 상한계와 하한계를 설정하지 않고 서버의 상태에 따라 적절하게 요청이 분배되도록 하였다. 15대의 PC를 사용하여 실험을 수행하였으며, 실험 결과는 기존 부하 분산 알고리즘 중 성능이 가장 좋은 알고리즘에 비해 서버의 성능이 동일한 경우 성능 및 소비전력 면에서 거의 동등하였고, 서버의 성능이 상이한 경우 50.2% 성능 향상 및 27.3% 소비 전력 절감을 확인하였다.

Exploiting Spatial Reuse Opportunity with Power Control in loco parentis Tree Topology of Low-power and Wide-area Networks (대부모 트리 구조의 저 전력 광역 네트워크를 위한 전력 제어 기반의 공간 재사용 기회 향상 기법)

  • Byeon, Seunggyu;Kim, JongDeok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.194-198
    • /
    • 2021
  • LoRa is a physical layer technology that is designed to provide a reliable long-range communication with introducing CSS and with introducing a loco parentis tree network. Since a leaf can utilize multiple parents at the same time with a single transmission, PDR increases logarithmically as the number of gateways increases. Because of the ALOHA-like MAC of LoRa, however, the PDR degrades even under the loco parentis tree topology similarly to the single-gateway environment. Our proposed method is aimed to achieve SDMA approach to reuse the same frequency in different areas. For that purpose, it elaborately controls each TxPower of the senders for each message in concurrent transmission to survive the collision at each different gateway. The gain from this so-called capture effect increases the capacity of resource-hungry LPWAN. Compared to a typical collision-free controlled-access scheme, our method outperforms by 10-35% from the perspective of the total count of the consumed time slots. Also, due to the power control mechanism in our method, the energy consumption reduced by 20-40%.

  • PDF