• 제목/요약/키워드: 전력설비

Search Result 2,896, Processing Time 0.042 seconds

High Efficiency Power Conversion System of Non Isolated Type Applied in Fuel Cell Generator Used to Fire Prevention Installation (소방 방재설비용 연료전지 발전시스템의 비절연형 고효율 전력변환기 설계)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.19-26
    • /
    • 2006
  • In this paper, author proposes to a fuel cell generation system used to fire prevention installation at emergency. The proposed system is used with a power source of fire prevention installation in preparation for breaking of commercial power supply at emergency. A part of most power loss of the fuel cell generation system is power converter. And the major losses of power converter are switching losses of power semiconductor switches used to power conversion. This parer is designed with a high efficiency power converter of non isolated type in order to increase efficiency of fuel cell power system. The controlling switches used in power conversion system are operated with soft switching, which is applied to partial resonant method to reduce switching loss. The result is that the fuel cell power system gets to high efficiency. Some computer simulated results and experimental results are confirmed to the validity of the analytical results.

  • PDF

Power Monitoring and Equipment Diagnosis System (전력감시진단종합 시스템)

  • Bahng, S.J.;Jin, M.G.;Lee, S.C.;Kim, Y.I.;Kim, P.S.;Nam, S.S.;Choi, C.H.;Park, J.H.;Sihn, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.252-254
    • /
    • 2005
  • 전력계통을 감시, 보호하기 위해서 해당 도메인에 맞게 전력감시 시스템을 운용한다. 전기품질을 위해서 전기품질감시 시스템을, 전력설비의 노후 정도, 교체기간을 감시하기 위해서 전력설비진단 시스템을 각각 운용한다. 최근 전력 IT 기술의 발달과 전력감시 시스템의 효율적 관리가 필요하게 되면서 국내외 선진사들은 전력시스템의 통합 솔루션을 소개, 개발하고 있는 추세이다. 본 논문에서는 전력감시 시스템들을 총합한 전력감시진단종합 시스템을 개 발하였고 이를 소개하고자 한다.

  • PDF

Analysis of Decentralized Energy using WADE Economic Model (WADE Economic Model에 의한 분산형전원 분석)

  • Kim, Yong-Ha;Woo, Sung-Min;Lee, Kwang-Sung
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.88-99
    • /
    • 2008
  • This paper analyzed quantitative effect on sorts of scenario for DE (Decentralized Energy) in the Korean Power System using WADE Economic Model. WADE Economic Model calculated shortage of power sales from the existing technologies above all. and it construct a new type of technologies according to sorts of scenario for DE. generating capacity and electricity generation is computed from this process. From now on can assess the side of environment meant $CO_2$, $NO_x$, $SO_x$, PM10 and cost meant electric retail cost that composed of construction, T&D, fuel, maintenance and environment.

Development on the Methodology of CDM Projects in the SF6 Recovery and Recycling of Electrical Equipment (전력설비에서의 SF6 회수 및 재활용 CDM 방법론 개발)

  • Pyo, Jeong-Gwan;Sa, Jae-Hwan;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.2 no.3
    • /
    • pp.143-159
    • /
    • 2011
  • Projects applying the CDM methodology AM0035 of the $SF_6$ Emission Reductions in Electrical Grids should provide direct monitoring of all the key parameters that are related to estimation of baseline and project emissions including detailed explanations of key operating conditions and procedures, and an explanation addressing uncertainty as the result of EB meeting 41. Through this study, recovery ratio during maintenance, purity of $SF_6$ before and after disposal, replacing, loss rate of $SF_6$ before and after reclamation, leakage emission from electricity consumption and fossil fuel combustion, considered conservatively the key parameter of various monitoring. Consequently, confirmed the reduction in the amount of reduction due to the baseline emission decrease, project emission increase.

A Study on realtime and two-way Communication of customer's electric load facility for DR system (수요 측 전력설비의 실시간 양방향 통신에 관한 연구)

  • Ko, Jong-Min;Yu, In-Hyeob;Yang, Il-Kwon;Song, Jae-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.542-543
    • /
    • 2008
  • 전력산업의 환경변화에 따라 단일 공급자였던 한전을 비롯하여 전력판매사업자, 민간부하사업자, 에너지컨설팅사업자 등 에너지관련 서비스를 제공하는 주체자(이하 ESP : Energy Service Provider)의 참여로 전력시장이 경쟁체제로의 변화가 예상된다. 이러한 주체는 전력에너지 관리 최적화를 위한 수요측의 전력자원과 정보의 통합관리가 필요하다. 또한 수요측 서비스 개선과 동시에 수익을 창출할 수 있는 부가 서비스의 개발이 또한 요구될 것이다. 최근 석유가격의 지속적인 상승으로 도매시장가격은 더욱 증가할 것으로 예상된다. 현재 우리나라는 CBP 형태의 전력시장에서 시간대별로 변하는 전력가격(SMP)에 의하여 시장가격이 정해진다. 따라서 시장가격이 높아지면 높아질수록 전력을 구입하고 있는 전력사업자의 경우 구입비의 증가로 재무 건전성 확보에 악영향을 초래한다. 따라서 효율적인 전력 수요절감을 통해 구입전력비를 절감할 수 있는 신수요관리 기법이 필요하다. 이러한 신수요관리 기법은 국가적으로는 하계수급비상 해소와 신규 건설비용 및 혼잡비용을 회피하고, 전력사업자는 구입전력비의 절감을 통해 전력도매시장가격의 안정을 도모할 수 있다. 이러한 수요절감 기법 중 수요측의 자율적인 참여 및 반응을 기반으로 하는 수요반응(Demand Response, 이하 DR)이 있으며, 이는 전력사업자와 수요 측 전력부하설비와의 양방향 통신 및 제어 인프라 구축이 필요하다. 본 논문은 이러한 DR운영에서 반드시 필요한 수요측 전력부하설비와의 양방향 통신 및 제어 인프라구축에 대한 방법 및 결과를 제시하고자 한다.

  • PDF

Realtime Digital Monitoring and Controller Development for Power Systems (전력시스템의 실시간 디지털 중앙감시 및 제어장치 개발)

  • Jong-Dug Cho;Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1517-1522
    • /
    • 2001
  • In this paper, We propose digital protective relay which monitors the status of distribution line and controls power apparatus with real time operation. Digital protective relay improves the performance of basic functions which are measurement, display and communication. The Int one we consider is that the protective device has the standard method for protecting the distribution systems which are circuit brakers, switch and emergency generators. These are Protected by analog type Protective relay and devices. The security requirements should be activated within a few seconds, and with real time operation. The second one is an efficient method for adapting the one chip micro-processor(PIC16F84) which is enable to digital control system. The proposed methods are implemented with experimental results and have an high fidelity characteristics in local experiment tests.

  • PDF

Study of a Overcurrent Synthetic Circuit Test for Thyristor Switched Capacitor of Static Var Compensator. (SVC TSC Valve의 과전류 합성시험에 관한 연구)

  • Lee, Jin Hee;Kim, Young Woo;Zhen, Yuan;Jung, Teag Sun;Baek, Seung Taek
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.163-164
    • /
    • 2014
  • 전력계통은 전력수요의 지속적인 성장에 따라서 전력설비의 추가를 지속적으로 추진하고 있지만, 심해지는 환경문제 등으로 인해 용지 확보에 어려움이 있다. 이로 인해 송전선로 장거리화, 용량부족량 등 전력계통에 여러 가지 복잡한 문제가 야기되는데. 이것은 곧 전력계통의 안정도와 직결된다. 이러한 문제를 효과적이면서 경제적인 해결방법으로 FACT(Flexible AC Transmission System)기술이 주목 받고 있다. FACTS 기기 중 SVC(Static Var Compensator)는 상용운전 중이며, 기존 동기조상기에 비해 저렴하고, 신속 정확한 전압제어를 하는 장점이 있다. SVC는 TCR(Thyristor Controlled Reactor)과 TSC(Thyristor Switched Capacitor), FC(Fixed Capacitor)등 여러 종류의 구성을 가지고 있다. 합성시험회로설비(Synthetic Test Circuit)는 Thyristor로 구성된 TCR, TSC Valve를 실제 운전조건으로 동작시켜 SVC Valve의 신뢰성을 검증하는 설비이다. 특히, TSC Valve는 운전시 초기 과전류가 발생하는 운전특성상 이에 대한 평가기준에 따른 시험을 통해 신뢰성을 반드시 검증하여야 한다. 본 논문에서는 IEC 61954에서 제시하는 시험평가 기준에 의거하여 TSC의 Overcurrent Test를 위한 STC 평가 방법를 기술하고 설계된 TSC 시험을 위한 STC topology와 Simulation으로 검증 방법을 기술한다.

  • PDF

A Study on the Overheat Inspecting System for Power Transformer using Fiber Bragg Grating Temperature Sensor (FBG 온도센서를 이용한 전력용 변압기 파열감시 시스템 연구)

  • Kim, Woo-Jin;Park, Hyoung-Jun;Song, Min-Ho;Lee, June-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.169-170
    • /
    • 2006
  • 대형화, 고압화되고 있는 전력설비는 사고가 발생할 경우 그에 수반되는 산업, 경제, 사회적인 손실의 규모가 매우 커지는 경향을 가진다. 특히 적정온도 이상에서의 운전은 전력설비의 오동작을 일으키는 주요한 원인 중 하나이므로 비정상적인 온도상승을 조기에 감지하여 사고의 가능성을 감소시키는 시스템의 개발은 안정적인 전력설비 운용에 반드시 필요한 요소기술이다. 기존의 감시 시스템은 대부분 여러 위치의 정보를 동시에 얻기 위하여 여러 개의 개별 센서를 배열하여야하므로 대형중량화가 불가피하다는 단점을 갖고 있다. 그러나 광섬유 FBG 온도센서는 전자기 간섭의 영향을 받지 않고, 여러 개의 센서를 하나의 광섬유 라인에 설치하여 동시에 여러 부위의 온도를 측정할 수 있는 준분배형 온도센서 구현이 가능하다는 장점으로 과열감시 시스템에 적합한 센서로 인식된다. 본 연구에서는 광섬유 FBG 온도센서를 이용하여 변압기 단락시험을 통해 변압기의 온도 변화를 T-type thermocouple(이하 TC)과 동일한 지점에서 측정하고, 그 데이터를 비교분석함으로써 광섬유 FBG 온도센서 시스템의 신뢰성을 검증하였고, 이를 전력용 변압기 과열감시 시스템으로 적용할 수 있음을 제시하였다.

  • PDF

Synthetic Circuit for Thyristor controlled Reactor of Static Var Compensator operational Test (SVC의 TCR Operational Test를 위한 합성시험회로)

  • Kim, Young Woo;Lee, Jin Hee;Jung, Teag Sun;Baek, Seung Taek;Chung, Young Ho
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.51-52
    • /
    • 2014
  • 전력계통은 전력수요의 지속적인 성장에 따라서 전력설비의 추가를 지속적으로 추진하고 있지만, 심해지는 환경문제 등으로 인해 용지 확보에 어려움이 있다. 이로 인해 송전선로 장거리화, 용량부족량 등 전력계통에 여러 가지 복잡한 문제가 야기되는데, 이것은 곧 전력계통의 안정도와 직결된다. 이러한 문제를 효과적이면서 경제적인 해결방법으로 FACT(Flexible AC Transmission System)기술이 주목 받고 있다. FACTS 기기 중 SVC(Static Var Compensator)는 상용운전 중이며, 기존 동기조상기에 비해 저렴하고, 신속 정확한 전압제어를 하는 장점이 있다. SVC는 TCR(Thyristor Controlled Reactor)과 TSC(Thyristor Switched Capacitor), FC(Fixed Capacitor)등 여러 종류의 구성을 가질 수 있다. TCR과 TSC는 실제 운전에 앞서 여러 가지 방법으로 검증이 필요하다. 합성 시험회로 설비(Synthetic Test Circuit)는 TCR과 TSC 안에 존재하는 Thyristor Valve의 동작을 실제 동작 조건으로 동작시켜, 동작의 신뢰성을 검증하는 설비이다. 본 논문에서는 TCR의 Operational Test를 위한 STC를 기술하고 있다. 설계된 STC는 PSCAD를 사용하여 검증하였다.

  • PDF

Analysis of Overvoltage according to Lightning of Distribution Systems (배전계통의 뇌격에 따른 과전압 분석)

  • Choi, Seung-Hyun;Kim, Hyoun-Su;Yeo, Sang-Min;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2227_2228
    • /
    • 2009
  • 낙뢰가 전력계통에 유입되면 전력설비 및 통신설비에 영향을 미쳐 경제적인 손실로 이어지는 문제점을 초래한다. 본 논문에서는 배전계통에서의 뇌격전류의 크기, 뇌격지점에서의 거리, 그리고 접지저항의 크기에 따른 과전압을 전력계통 과도현상 프로그램인 EMTP(Electro-Magnetic Transients Program)을 이용하여 모의 및 분석하였다.

  • PDF