• Title/Summary/Keyword: 전력선 채널

Search Result 174, Processing Time 0.031 seconds

A Study on the Cancellation of Harmonic Noise for the Improvement of Data Transmission Characteristics in Power Line Channel (전력선 채널의 데이터 전송 특성 개선을 위한 고조파 잡음 제거에 관한 연구)

  • 박준현;김남용;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.3
    • /
    • pp.259-269
    • /
    • 1991
  • In this paper, power line harmonic noise which is the most serious problem in the secondary power distribution line is eliminated and analyzed using adaptive noise cancellers with two adaptive algorithms, LMS and individual tap LMS(ITLMS) algorithm. To testify the improvement of data transmission characteristics made by the adaptive filter with two adaptive algorithms, BER was measured in DS spread spectrum communication system including the noise canceller.

  • PDF

A Study for Indirect Channel Noise Measurement in Powerline Communications (전력선 통신 채널의 간접 잡음 측정에 대한 방안 연구)

  • Son, Hyun-Il;Oh, Hui-Myoung;Lee, Jae-Jo;Lee, Won-Tae;Kim, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2611-2613
    • /
    • 2002
  • 본 논문에서는 전력선 통신 채널의 간접 잡음 측정에 대한 연구를 하였다. 주위 환경에 의한 Noise 및 여러 통신매체에 의한 방해전파에 의해 전력선 통신 채널은 송신 측의 고출력 요구와 가능한 전력선 통신의 대역폭이 감소하는 악화된 통신환경을 보여 준다. 이러한 Noise를 측정하는 방법은 Coupling Capacitor를 이용한 직접 측정 방식과 이동 측정 장치를 이용한 간접 측정 방식이 있다. 전자는 광범위한 측정지역과 측정장비의 설치 등에서의 번잡함으로 효과적인 Noise 측정이 어렵다. 본 논문에서는 두 가지 방식의 Noise 측정 결과의 비교 및 검토를 통해 이동 측정 장치를 이용한 방식의 장점과 보완할 점을 검토였으며, 특히 직접 측정 방식과의 결과 값의 차이를 보상할 수 있는 상관관계 분석의 필요성을 고찰하였다.

  • PDF

Measurement of Indoor Power Line Channel Characteristics Considering Capacitive Loads (용량성 부하를 고려한 옥내 전력선 채널 특성 측정)

  • Heo Yoon-Seok;Hong Bong-Hwa;Kim Chul;Jun Kye-Suk;Lee Dae-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.53-60
    • /
    • 2005
  • Considerable efforts has been recently devoted to the determination of accurate channel models for the power line environment, both for the indoor and outdoor cases. The common limitation of the known and previously published models is the particular type of approach followed. This paper is concerned with a power line channel characteristic measurement for the more fast and efficiently power line communication experiment. The need arises from the fact that indoor power cables consist of conductors and inductors. A capacitive load simulator is a essential equipment in the power line modem development for indoor power line network. We accomplished a channel data base by the frequency response method about the total 224 capacitor load cases. On the basis of this measurement modeling it is here revealed that the power line communication channel is a more deterministic media.

Outage Probability Analysis for Single User System in Power Line Communications (단일 사용자 전력선 통신 환경에서의 outage 확률 분석)

  • Shin, Jae-Young;Jeong, Ji-Chai
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.321_322
    • /
    • 2009
  • 최근 전력선 통신이 홈 네트워킹의 새로운 기술로 주목을 받고 있어 관련 수요가 증가하고 있다. 안정적인 통신을 위하여 일정한 QoS(Quality of Service)의 제공은 매우 중요하다. 본 논문에서는 outage 확률 분석을 위하여 시뮬레이션을 이용한 옥내 전력선 통신 환경에 대한 채널 응답과 채널 용량을 계산하였다. 계산된 채널 응답과 채널 용량을 바탕으로 전송 신호의 파워에 따른 outage 확률을 분석을 하였다. 시뮬레이션 분석 결과 아주 높은 수준과 아주 낮은 수준의 QoS 환경에서 전송 신호의 파워는 outage 확률에 영향을 미치지 않았다. 하지만, 30% ~ 50% outage를 허용하는 QoS 환경에서는 전송 신호의 파워에 따라서 outage 확률이 상대적으로 크게 변화하였다. 따라서 본 논문에서는 outage 확률측면에서 전송 신호의 파워를 효율적으로 이용할 수 있는 방향을 제시한다.

  • PDF

A Channel modeling and analysis of Indoor power cable for UWB communication system (구내용 전력케이블기반의 UWB통신용 채널특성분석에 관한 연구)

  • Cha, Jae-Sang;Jeong, Jae-Ho;Kim, Dae-Sik;Kim, Hyo-Jin;Moon, Kyung-Hwan;Lee, Jong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.78-80
    • /
    • 2006
  • 전력계통망 및 수용가는 다양한 형태의 전력케이블 및 전력선이 연계된 분 배전망을 형성하고 있다. 특히, 이렇게 구성된 분 배전망은 하나의 전력계통으로서 연계된 전력망을 형성하고 있으며, 이를 전력선통신의 인프라로 활용할 수 있다. 최근 들어, 전력선통신 기술에 대한 연구가 활발히 진행되고 있으며, 계통에 연계된 부하와 분기선로 그리고 매질의 특성에 따라 통신환경이 달라진다. 특히 전송 주파수에 따른 신호의 감쇠, 연계된 부하의 종류와 이들 부하로 인한 잡음원의 유입 및 전송신호의 왜곡 등이 주요한 채널환경 요소이다. 본 논문에서는 상기 나열한 한계점을 극복하기 위한 대안으로 전력선 및 케이블의 매질특성을 평가하고, 이에 따른 전송신호의 영향을 분석, 연계된 다양한 부하들의 변동에 따른 통신환경의 변화 영향 그리고 통신성능에 미치는 영향을 분석하였으며, 또한 전력 케이블 및 선로의 특성과 부하변동 특성을 반영하여 구내용 전력케이블 기반의 UWB(Ultra Wide Band) 통신용 채널 환경을 모델링하는 방안을 제안하고자 한다.

  • PDF

An Analysis of Characteristics of Underground Power line Communication Channel (지중 전력선 통신채널의 특성 해석)

  • Eom, Ki-Hwan;Shin, Jai-Ho;Lee, Seung-Joon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.5
    • /
    • pp.40-45
    • /
    • 2011
  • In this paper, to develop a broadband power line communication modem and network technologies, we analysis the characteristics of underground power line communication channel through actual tests. To measure the amount of attenuation by length and structure of broadband power line communication channel, we configure a measurement system of the channel with signal generator, spectrum analyzer and non-contacted coupler. For actual tests, we choose two of the longest lines among medium-voltage lines as a single line in the test lines and measure the characteristics of noise and signal attenuation level of the channel. The experimental results show that the channel has a impulse noise which can remarkably reduce communication capability. In the case of long lines, high-frequency attenuation appeared by length of the lines.

Effect of Interference from DC Power Supply on Power Line Communication Channel (전력선 통신 채널에서 직류전원 공급장치의 간섭 영향)

  • Kim, Sungeon;Jeon, Taehyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.111-115
    • /
    • 2014
  • Power line communications can be utilized to build up the data transmission network wherever the electricity is available. This type of communication system could provide a basis for the network construction in many application areas which include the smart grid and home networks. On the other hand the power line communication is vulnerable to various types of interferences and noises. Also, its channel characteristics are constantly changing depending on the type and the amount of electrical loads connected to the network. Especially, the usage of DC power supply has been increased due to the explosive expansion of smart devices in our daily lives which result in the increased level of interferences on the power line channel. In this paper, the effect of the operation of the DC power supplies on the channel characteristics and the data transmission performance is analyzed through the experiments.

Evaluation of the home power line channel's communication reliability in Internet operation of home appliances (전력선 통신망 네트워크상의 가전제품 통신 신뢰도 측정 및 분석에 관한 연구)

  • Ahn Nam-Ho;Choi Won-Sup;Chang Tae-Gyu;Kim Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.1 no.1
    • /
    • pp.65-72
    • /
    • 2002
  • 본 논문에서는 인터넷 가전제어를 위한 전력선 통신망 채널 특성 추정 기법을 제시하였고 실 거주 댁내 전력선 통신망의 채널 특성을 실측하여 통신 신뢰도를 평가하였다. 전력선 통신 기능을 내장한 동일 모델의 네트워크 가전제품 4종(에어컨, 냉장고, 세탁기, 전자렌지)을 실 거주 가정 100가구에 설치하여 전력선 통신망의 통신 신뢰도를 평가하였다. 통신 신뢰도의 평가 결과 통신 신뢰도가 90%이상이 나타나는 것을 확인하였다. 이것은 PLC모뎀이 장착된 가전제품의 활용과 고밀도 아파트 주거 지역에서 인터넷 가전제어를 위한 서비스가 상업적으로 이용할 수 있는 근거를 뒷받침한다고 할 수 있다.

  • PDF

Implementation and Performance Analysis of PLC Scheme based on SISO/MIMO-OFDM using MRC (최대비 합성법을 이용한 SISO/MIMO-OFDM 기반 전력선 통신 방식 구현 및 성능분석)

  • Yoo, Jeong-Hwa;Choe, Sang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2B
    • /
    • pp.176-183
    • /
    • 2011
  • In this paper, we propose the implementation and performance analysis of power line communication based on SISO/MIMO-OFDM which focuses on high speed data transmission in smart grid and future power line grid. We employ Zimmermann frequency model and Middleton Class A model as the multipath power line fading channel and impulse noise channel, respectively. In this paper, in order to improve the three-phase or single-phase PLC performance, we introduce a new MRC (called a&f-MRC) which effectively sums up multiple antenna diversity gain and multipath fading diversity gain. Via simulation, we prove the performance advantage over existing SISO/MIMO systems. In addition, we offer the tradeoff on system design through comparing with MRC, EGC and SC.

Performance Characteristics of Broadband PLC at Out-door Field Test-bed (저압 인입선에서의 고속 전력선통신 특성 분석)

  • Park Byung-Seok;Yoo Dong-Hee;Hyun Duck-Hwa;Choi Young-Lim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.264-273
    • /
    • 2005
  • Broadband power line communications have been receiving tremendous interest In recent years because this technology enables utilities to deploy a communication network over existing power line infrastructures. Despite the enormous potential, there is some skepticism about the technology and its commercial viability. In this paper, we investigate the performance characteristic of PLC through field test carried out in actual households. Also it addresses major field deployment aspects, such as range, coverage, the number of node for operation and maintenance.