• Title/Summary/Keyword: 전기 잡음

Search Result 792, Processing Time 0.024 seconds

Quality Improvement of Low-Bitrate HE-AAC Encoder (HE-AAC 부호화의 저비트율에서 음질향상 기법)

  • Kim, Jeong-Geun;Lee, Jae-Seong;Lee, Tae-Jin;Kang, Kyeong-Ok;Park, Young-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.66-74
    • /
    • 2008
  • In this paper, we propose new techniques that can improve the quality of AAC and SBR encoders comprised in low bitrate HE-AAC. To reduce the pre-echo artifacts often occurring for transient blocks in AAC, we propose an extended Temporal Noise Shaping (sTNS) in which the frequency range is selectively extended down to the low-frequency region. Also, for he high-frequency region being coded by SBR encoder, tones are identified through a sinusoidal modeling and their frequencies are adjusted within the QMF band in order to reduce the noise floor due to aliasing. Spectrograms of the decoded signals were compared and listening tests were conducted to evaluate the proposed algorithm. Results confirmed the effectiveness of the proposed algorithm.

Measurement set-up for CMOS-based integrated circuits and systems at cryogenic temperature (CMOS 기반의 집적 회로 및 시스템을 위한 극저온 측정 환경 구축)

  • Hyeon-Sik Ahn;Yoonseuk Choi;Junghwan Han;Jae-Won Nam;Kunhee Cho;Jusung Kim
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.174-179
    • /
    • 2024
  • In this work, we introduce a complementary metal-oxide semiconductor(CMOS)-based integrated circuit(IC) measurement set-up for quantum computer control and read-out using a cryogenic refrigerator. CMOS circuits have to operate at extremely low temperatures of 3 to 5 K for qubit stability and noise reduction. The existing cryogenic measurement system is liquid helium quenching, which is expensive due to the long-term use of expendable resources. Therefore, we describe a cryogenic measurement system based on a closed cycle refrigerator (CCR) that is cost-free even when using helium gas for long periods of time. The refrigerator capable of reaching 4.7 K was built using a Gifford-Mcmahon(G-M) type cryocooler. This is expected to be a cryogenic refrigerator set-up with excellent price competitiveness.

Evaluation on real-time multi-point sensing performance of IoT-based hybrid measurement system (IoT 기반 하이브리드 계측시스템 실시간 다점 측정 성능 평가)

  • Kim, Heonyoung;Kang, Donghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.543-550
    • /
    • 2018
  • The rapid growth of IoT technology induced by the fourth industrial revolution has resulted in research into various types of wireless sensors, and applications based on this technology are prevalent in many areas. However, among the various sites where this technology is used, railway bridges and tunnels with lengths of tens of kilometers have problems with data acquisition, due to the signal noise induced by the long distance measurement and EMI induced by the high voltage power feeding system, when conventional electric sensors are used. To overcome these problems, many studies on fiber optic sensors have been conducted as a substitute for the conventional electric sensors. However, restrictions on the types of fiber optic sensors have limited their application in railways. For this reason, a hybrid measurement system with IoT based wireless data communication, in which both electric and fiber optic sensors can be applied simultaneously, has been developed. In this study, in order to evaluate the applicability of the hybrid measurement system developed in the previous study, a real-time test for 4 types of measurement environments, which reflect possible railway sites, is performed. As a result, it was confirmed that the signals from both the electric and fiber optic sensors, which were acquired at a remote area in real-time, showed good agreement with each other and that this measurement system has the potential to handle sensors with a sampling rate of 2.5 kHz. In the future, it is expected that the IoT-based hybrid measurement system will contribute to the improvement of structural safety by enabling real-time structural health monitoring when applied to various measurement sites.

Design and Fabrication of Wide Electrical Tuning Range DRO Using Open-Loop Method (개루프 방법에 의한 확장된 전기적주파수조정범위를 갖는 유전체공진기발진기의 설계 및 제작)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yang, Seong-Sik;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.6
    • /
    • pp.570-579
    • /
    • 2009
  • In this paper, we presented a Vt-DRO with a wide electrical frequency tuning range, using open-loop gain method. The Vt-DRO was composed of 3-stages, resonator, amplifier and phase shifter. In order to satisfy an oscillation condition, we determined magnitude and phase of each stage. The measured S-parameter of cascaded 3-stages shows open-loop oscillation condition. Also, using measured open loop group delay, we derived the relation for electrical frequency tuning range. The Vt-DRO was implemented by connecting the input and the output of the designed open-loop and resulted in closed-loop. As a results, tuning-range of Vt-DRO is 82 MHz, which is close to the predicted results for tuning voltage 0${\sim}$10 V and shows linear frequency tuning at the center frequency of 5.3 GHz. The phase noise is -104 ${\pm}$1 dBc/Hz at 100 kHz offset frequency and power is 5.86${\pm}$1 dBm respectively.

상부 Au 전극 면적 Size에 따른 PbI2 필름의 전기적 특성 평가

  • Myeong, Ju-Yeon;Park, Jeong-Eun;Kim, Dae-Guk;Kim, Gyo-Tae;Jo, Gyu-Seok;O, Gyeong-Min;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.374-374
    • /
    • 2014
  • 의료용 X-ray는 과거 analog 방식과, 연구가 진행 중이며 현재 많이 사용되고 있는 digital 방식으로 나누어진다. 최근, 광도전체와 형광체 기반의 flat panel X-ray detector의 발전에 따른 상용화가 이루어지고 있으며, 많은 발전 가능성이 제기되고 있다. flat panel X-ray detector 검출방식은 direct method (직접 방식)와 indirect method (간접 방식)로 나누어진다. 본 연구는 일반적으로 상용화 되어있는 amorphous seleinum (비정질 셀레늄)의 큰 일함수에 의한 저 해상력이라는 단점을 보완하기 위해, 작은 일함수를 가지는 물질을 사용하여, 영상을 얻을 시에 높은 해상력으로 표현할 수 있도록 하고, 원자번호가 높은 물질을 사용하여 X-ray 흡수율을 높일 수 있도록 기존 direct method에 많이 사용되고 있는 amorphous seleinum 기반 digital X-ray detector가 아닌, 이러한 장점을 충족시킬 수 있는 PbI2 물질 층을 사용하여 시편을 제작 하였다. PbI2를 같은 두께로 올린 후, 물질 층 상부에 Au 전극 면적을 다른 size로 제작한 시편으로 X-ray에 노출 시켰다. 이는 상부 전극 size 차이에 따른 신호 차이를 측정하여 전기적 특성을 평가하기 위한 것이다. 전도성을 띠고 있는 ITO (Indium - Tin - Oxide) glass를 이용하여 screen printing 방법으로 제작하였다. PbI2층을 약 160~180 um두께, $3cm{\times}3cm$ size로 5개 제작하였으며, 상부 전극으로는 Au를 진공 증착 시켰다. 상부 전극 size는 각각 시편 5개에 $0.5cm{\times}0.5cm$, $1cm{\times}1cm$, $1.5cm{\times}1.5cm$, $2cm{\times}2cm$, $2.5cm{\times}2.5cm$로 PbI2 물질 층 중앙에 증착 시켰다. 이러한 설정으로 X-ray 노출 시 관찰할 수 있는 PbI2의 전기적인 특성을 평가할 수 있었다. 관전압을 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp, 140 kVp로 설정하고, 관전류는 100 mA로 설정하였으며, Dark current, Sensitivity를 측정하였다. Dark current와 Sensitivity를 측정한 뒤, 그 값을 이용하여 SNR (신호 대 잡음 비)값을 구해보았다.실험 결과 단위면적당 signal과 SNR을 분석할 수 있었다. 80 kVp로 기준을 잡고 결과 값을 보면 $0.5cm{\times}0.5cm$ 시편에서 2.92 nC/cm2, $2.5cm{\times}2.5cm$ 시편에서 0.84 nC/cm2로 상부 전극 크기가 작을수록 더 좋은 신호를 측정할 수 있었다. 똑같은 기준에서 SNR을 계산 해 보았을 때, $0.5cm{\times}0.5cm$ 시편에서 6.46, $2.5cm{\times}2.5cm$ 시편에서 1.91로 SNR역시 상부 전극 크기가 작을수록 더 큰 값을 확인할 수 있었다. 이러한 결과는 edge-effect의 영향으로 인해 나온 결과라고 할 수 있다. 이러한 실험 결과, detector 제작 시, 같은 물질을 사용하여 더 높은 효율을 내기 위해서는 큰 size의 상부 전극 보다는 작은 size의 상부 전극을 증착 시키는 것이 전기적 특성을 더욱 효율적으로 평가할 수 있을 것이라고 사료된다.

  • PDF

Pole-pole array electrical resistivity survey and an effective interpretational scheme of its data (2극법 전기비저항 탐사 자료의 효율적인 해석방법)

  • Cho Dong-Heng;Lee Chang Yourl;Jee Sang-Keun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.112-131
    • /
    • 2000
  • In spite of its many strong points, pole-pole electrode configuration is not often used for ground electrical resistivity survey except for bore hole survey as normal logging and for archaeological investigation. Above all, poor spatial resolution of pole-pole survey may be responsible for this. But recent experiences so far gained by the present authers lead them to think that pole-pole survey can be at least a viable means of reconnaissance survey in near-surface conductive environment and an effective interpretational scheme may augment its resolution. As well known, a response of any other electrode configuration is a linear combination of pole-pole responses. Based on this principle of linear superposition and the principle of reciprocity, the other 'responses' can be derived with simple additions and subtractions of pole-pole responses. Though such responses are not always correct due to the adverse effects of noises, combined with the potential decay curves, they can be helpful to interprete better pole-pole survey data especially in connection of the resolution. This can be comparable to the use of the first or second derivatives of gravity and magnetic intensity surveys.

  • PDF

Image Reconstruction Using Iterative Regularization Scheme Based on Residual Error in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 잔류오차 기반의 반복적 조정기법을 이용한 영상 복원)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.272-281
    • /
    • 2014
  • In electrical impedance tomography (EIT), modified Newton Raphson (mNR) method is widely used inverse algorithm for static image reconstruction due to its convergence speed and estimation accuracy. The unknown conductivity distribution is estimated iteratively by minimizing a cost functional such that the residual error namely the difference in measured and calculated voltages is reduced. Although, mNR method has good estimation performance, EIT inverse problem still suffers from ill-conditioned and ill-posedness nature. To mitigate the ill-posedness, generally, regularization methods are adopted. The inverse solution is highly dependent on the choice of regularization parameter. In most cases, the regularization parameter has a constant value and is chosen based on experience or trail and error approach. In situations, when the internal distribution changes or with high measurement noise, the solution does not get converged with the use of constant regularization parameter. Therefore, in this paper, in order to improve the image reconstruction performance, we propose a new scheme to determine the regularization parameter. The regularization parameter is computed based on residual error and updated every iteration. The proposed scheme is tested with numerical simulations and laboratory phantom experiments. The results show an improved reconstruction performance when using the proposed regularization scheme as compared to constant regularization scheme.

Sensitivity Analysis and Estimation of the Depth of Investigation in Small-Loop EM Surveys (소형루프 전자탐사의 감도분석 및 가탐심도 추정)

  • Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.299-308
    • /
    • 2002
  • We have derived an analytical expression for the sensitivity of the frequency domain small-loop electromagnetic (EM) surveys over a two-layer earth in order to estimate the depth of investigation with an instrument having the source-receiver separation of about 2 m. We analyzed the sensitivities to the lower layer normalized by those to the upper half-space and estimated the depth of investigation from the sensitivity analyses and the mutual impedance ratio. The computational results showed that the in-phase components of the sensitivity to the lower layer dominates those to the upper layer when the thickness of the upper layer is less than 20 m, while the quadrature components are not sensitive to the lower layer over the entire frequency range. Hence we confirmed that the accurate measurement of the in-phase component is essential to increase the depth of investigation in the multi-frequency small-loop EM survey. When conductive basement of 10 ohm-m underlies the upper layer of 100 ohm-m, an accurate measurement of the in-phase components ensures the depth of the investigation more than 10 m even accounting a noise effect, from which we conclude that the small-loop EM survey is quite effective in imaging the conductive plume down to a considerable depth. On the other hand, in the presence of the resistive basement of 1,000 ohm-m, the depth of investigation may not exceed 5 m considering the instrumental accuracy, which implies that the application of the small-loop EM survey is not recommended over the resistive environment other than detecting the buried conductor.

Direct blast suppression for bi-static sonar systems with high duty cycle based on adaptive filters (고반복률을 갖는 양상태 소나 시스템에서의 적응형 필터를 이용한 송신 직접파 제거 연구)

  • Lee, Wonnyoung;Jeong, Euicheol;Yoon, Kyungsik;Kim, Geunhwan;Kim, Dohyung;You, Yena;Lee, Seokjin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.446-460
    • /
    • 2022
  • In this paper, we propose an algorithm to improve target detection rate degradation due to direct blast in a bi-static sonar systems with high duty cycle using an adaptive filters. It is very important to suppress the direct blast in the aforementioned sonar systems because it has a fatal effect on the actual system operation. In this paper, the performance was evaluated by applying the Normalized Least Mean Square (NLMS) and Recursive Least Square (RLS) algorithms to the simulation and sea experimental data. The beam signals of the target and direct blast bearings were used as the input and desired signals, respectively. By optimizing the difference between the two signals, the direct blast is removed and only the target signal is remained. As a result of evaluating the results of the matched filter in the simulation, it was confirmed that the direct blast was removed to the noise level in both Linear Frequency Modultated (LFM) and Generalized Sinusoidal Frequency Modulated (GSFM), and in the case of GSFM, the target sidelobe decreased by more than 20 dB, thereby improving performance. In the sea experiment, it was confirmed that the LFM reduced the level of the transmitted direct wave by 10 dB, the GSFM reduced the level of the transmitted direct wave by about 4 dB, and the side lobe of the target decreased by about 4 dB, thereby improving the performance.

Brain-Waves Analysis according to Ego-state and OK-gram of Transactional Analysis Theory (교류분석이론의 자아상태와 인생태도에 따른 뇌파 분석)

  • Jeong, Cheon-Soo;Kim, Jung-Sam;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.858-863
    • /
    • 2014
  • Through this study, we found out whether to measure objectively by using Transactional Analysis(TA) evaluating their own growth and benefit of health through the change of Ego-state, the personality structure and brain waves monitoring electric signals occurring in the brain of the human biological signals. According to the results of brain-wave test, M-type is brain-waves of healthy adults and a, ${\beta}$ were dominantly observed in the occipital while not sleeping. In particular, ${\beta}$ appears widely throughout the brain during nervous or concentrating metal activities and unlike N-type experimenters, ${\beta}$ was found to be dominant in M-type experimenters even in stable condition. N-type is brain waves of healthy adults and a, ${\beta}$ were dominantly observed in the occipital while not sleeping. In particular, unlike nervous or concentrating M-type, there was no noise such as tension and blink while resting. In addition, it turned out that subjects with high levels of A ego do not return quickly to the stable state and show a lot of Blinking and swallowing saliva, noise regardless of the pattern of Egogram. And brain waves of 11 people that the difference in data of OK-gram and Ego-state is the same in all items or less than -5 showed a low amplitude of $20{\mu}V$ in general. In conclusion, this study identified that the theory of personality pattern of Transactional Analysis Theory and brain-wave findings are consistent and also found out that brain waves are also associated according to each Ego-state of Egogram.