선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성 (Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

전력용 변압기 중성점 리액터 단선 감시용 보호계전기 오동작 사례 분석 (The Analysis of Mal-Operation of Protection Relay for Detecting Disconnection of Neutral Grounding Reactor)

  • 강연욱;곽주식;김건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.603-605
    • /
    • 2005
  • 전력수요의 증대에 따른 계동모의 확장에 따라 관련기기는 초고압 및 대용량화 추세에 있다. 이러한 관련기기들 중에서도 특히 154/22.9kV 전력용 변압기는 고장시 수용가의 정전범위가 방대하고 변압기 내부 고장의 복구비용 또한 막대하므로 경제적 손실은 물론 사회적 영향도 크다. 우리나라에서는 1980년 초기부터 154/22.9kV 전력용 변압기의 고장이 급증하였으며, 이러한 원인은 주로 직전접지 방식을 채택하고 있는 한전 계통에서 배전선의 지락고장에 의한 지락고장 전류가 변압기 중성점을 통하여 변압기에 충격을 가함으로써 변압기 권선 단락 절연파괴 및 ULTC 고장 등이 발생하는 것으로 밝혀졌다. 따라서 한전에서는 변압기 중성점으로 흐르는 지락고장전류의 저감을 위해 변압기 중성점 접지 리액터(NGR: Neutral Ground Reactor)를 설치하여 운전하고 있으며, 결과 변압기 고장이 크게 감소하였다. 그러나 모선 절체시 변압기 1, 2차측 차단기 Trip 고장이 발생하였으며, 고장 발생 원인은 NGR 보호계전기 59GT 계전기의 오동작에 의한 86T Lock Out 계전기 동자으로 변압기 1, 2차측 차단기 Trip 고장이 발생한 것으로 추정된다. 따라서 본 논문에서는 무부하 모선 차단시 59GT 계전기에 나타나는 이상 전압을 EMTP (electro-magnetic transient program)를 이용하여 분석하였다.

  • PDF

액체질소에서의 열적 기포에 의한 절연파괴기구 (Thermal Bubble-Initiated Breakdown Mechanism of $LN_2$)

  • 곽동주;추영배;류강식;류경우;윤문수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.302-305
    • /
    • 1989
  • Ac, dc and impulse dielectric strengths of $LN_2$ at 0.1MPa were investigated experimentally, referring to the behavior of thermally induced bubble, which might be generated at quenching condition of immerged-cooling superconducting devices. The experimental results show that the bubble shape under electric field stress depends significantly on the applied voltage waveform. With ac voltage, the breakdown voltage of $LN_2$ falls suddenly near to one of the saturated gas at the threshold heater power of boiling onset. In control to this, the reduction of impulse breakdown voltage with heater peter is gradual and the time to breakdown depends on the existence of thermal bubble. These breakdown characteristics can be explained satisfactorily by the bubble behavior under electric fields.

  • PDF

$(Sr_{0.50}Pb_{0.25}Ba_{0.25})TiO_3$세라믹의 유전특성에 관한 연구 (A study on the dielectric properties of the $(Sr_{0.50}Pb_{0.25}Ba_{0.25})TiO_3$ ceramics)

  • 김세일;정장호;이성갑;배선기;이영희
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권3호
    • /
    • pp.267-271
    • /
    • 1995
  • The electrical properties of (S $r_{0.50}$P $b_{0.25}$B $a_{0.25}$)Ti $O_{3}$ ceramics were studied. Specimens were prepared by the conventional mixed oxide method, and fired between 1300[.deg. C] - 1375[.deg. C], for 2[hr.]. The electrical and structural preperties of specimens were investigated with sintering temperature. Increasing the sintering temperature from 1300[.deg. C] to 1375[.deg. C], average grain size was increased from 2.61[.mu.m] to 4.53[.mu.m]. (S $r_{0.50}$P $b_{0.25}$B $a_{0.25}$)Ti $O_{3}$ specimen sintered at 1350[.deg. C] for two hours showed good dielectric constant(2147) and dielectric loss(1.7[%]) properties at 1[khz]. Sintered density and breakdown field strength were the highest value of 5.75[g/c $m^{3}$], 20[kV/cm], respectively. Dielectric properties with applied voltage were independent of the sintering temperature.temperature.

  • PDF

에폭시/고무 거시계면에서 장시간 절연파괴전압에 대한 연구 (Study on the Long Time Breakdown Voltage in the Macro Interface between Epoxy and Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.1003-1008
    • /
    • 2002
  • In this paper, the estimation of lifetime with the various conditions of the interface between toughened epoxy and rubber which are consisting materials of underground power delivery system has been studied. After the measurement of the short time AC interfacial breakdown strength on macro interfaces at room temperature, the breakdown time at several voltages were measured under the constant voltages lower than the short time breakdown voltage. The long time breakdown voltage was calculated by using Inverse Power Law. Two types of interfaces was studied. One was the interface between toughened epoxy and EPDM(Ethylene Prorylene Diene Terpolymer). The other was the interface between toughened epoxy and silicon rubber. Interfacial pressure and roughness of interfaces was determined through the characteristic of short time AC interfacial breakdown strength. Oil condition was no oiled, low viscosity oiled and high viscosity oiled. High viscosity oiled interface between Toughened epoxy and silicon rubber had the best lifetime exponent, 20.69. and the breakdown voltage of this interface after 30 years was evaluated 19.27㎸.

Ar/$N_2$ 및 Kr/$N_2$ 혼합 가스의 교류절연파괴 특성 (AC Breakdown Characteristics in Ar/$N_2$ and Kr/$N_2$ Gas Mixtures)

  • 이상우;김이국;김인식;구경철;이동인;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1744-1746
    • /
    • 2001
  • In this paper, we investigated the breakdown characteristics of Ar, Kr and $N_2$ gas in pure states with pressure range of 58.8-137.3[kPa] under uniform and non-uniform fields, and the measured values are compared with those in Ar/$N_2$ gas mixtures. From these results, the breakdown voltages of $N_2$ gas in uniform field were increased about 4.8 and 4.4 times than those of Ar and Kr gas, respectively. Breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of $N_2$ gas. Breakdown voltages of Ar(70%)/$N_2$(30%) gas mixtures in the pressure of 101.3[kPa] (gap length : 3[mm]) were increased 1.9 times than those of pure Ar gas.

  • PDF

나노 충진제에 따른 에폭시 나노 컴퍼지트의 절연파괴강도 특성 (Dielectric Breakdown Characteristics Depending on The Nano Filler of Epoxy Nano-composites)

  • 박태학;백승학;이동건;박홍규;정인범;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.92-92
    • /
    • 2010
  • In this paper, the test is performed on MgO, which is used as a filler in epoxy additives, respectively (0, 1.0, 3.0, 5.0, 7.0, 10 [wt%]) for HVDC(high voltage direct current) submarine cable insulating material to improve electrical properties of epoxy resin in high temperature. The breakdown strength due to increasing amount of filler increased to 5.0 [wt%] by the effects of the Coulomb blockade. However, it is confirmed that strength of dielectric breakdown decreased because the filler functioned as impurities and affected the breakdown when filler additive exceeded by 5.0 [wt%] or more. We have found that the highest dielectric breakdown strength of specimen added 5.0 wt% at $25^{\circ}C$, and is more increased approximately 13.7 [%] than virgin specimen.

  • PDF

MgO를 첨가한 에폭시 나노 컴퍼지트의 절연파괴강도 온도의존성 (Temperature Dependence on dielectric breakdown strength of Epoxy Nano-Composites depending on MgO)

  • 정인범;한현석;이영상;조경순;신종열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.48-48
    • /
    • 2010
  • In this paper, we have investigated temperature dependence of dielectric breakdown voltage at epoxy with added nano-filler(MgO), which is used as a filler of epoxy additives for HVDC(high voltage direct current) submarine cable insulating material with high thermal conductivity and restraining tree to improve electrical properties of epoxy resin in high temperature region. In order to find dispersion of the specimen, the cross sectional area of nano-composite material is observed by using the SEM(Scanning Electron Microscope) and it is conformed that each specimen is evenly distributed without the cohesion. As a result, it is confirmed that the strength of breakdown of all specimen at 50 [$^{\circ}C$] decreased more than that of the dielectric breakdown strength at room temperature. When temperature increases from 50 [$^{\circ}C$] to 100 [$^{\circ}C$], we have confirmed that breakdown strength of virgin specimen decreases, but specimens with added MgO show constant dielectric breakdown strength.

  • PDF

XLPE/EPDM 계면에서의 절연파괴 특성 (Properties of Electrical Breakdown in the Interface between XLPE / EPDM)

  • 조정형;한성구;이창종;김석기;최용식;박강식;서광석;박대희;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1469-1471
    • /
    • 1996
  • In this paper, We intended to evaluate the characteristics of XLPE/EPDM interface which exists in the cable joint. The fault of practical cable was mainly occurred in this interface. Thus we looked into the electrical characteristics through the conduction current and the breakdown test. Through the experiment, we obtained the result that the conduction current in this interface flowed less than other dielectric materials, that the breakdown strength was higher and that the pressure dependance of the breakdown strength was higher.

  • PDF

전착된 폴리이미드 박막의 고온영역에서 절연파괴 특성에 관한 연구 (A Study on the Breakdown Characteristics of Electrodeposited Polyimide Film at High Temperature)

  • 유영복;신동국;김병준;김종석;박강식;김석기;조동헌;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1498-1501
    • /
    • 1996
  • To evaluate insulating properties of polyimide thin film on high temperature over $100\;^{\circ}C$, polyimide film were prepared by electrophoretic deposition onto metal surface from nonaqueous emulsion. The emulsion is made by adding a solution of the resin to a precipitant, which is an organic liquid compeltely miscible with the solvent of the organic resin solution, but which does not dissolve the resin. The polyimide film obtained by annealing shows good insulation properties of 5.8 MV/cm at elevated temperature and breakdown strength of the film reveals thickness dependence.