• Title/Summary/Keyword: 전기적 특성 측정

Search Result 2,962, Processing Time 0.036 seconds

A Study on Comparative Analysis of Food Characteristics of Sea Bream and Similar Species (도미와 유사어종의 식품학적 특성비교 분석에 관한 연구)

  • Chung, Ji-Yong;Jung, Young Mi
    • Culinary science and hospitality research
    • /
    • v.23 no.2
    • /
    • pp.159-168
    • /
    • 2017
  • This study was conducted to compare the food quality of domesticated species. Consumers surveyed for safe food intake and proper culture of food distribution. The results of the comparison study are as follows. Muscle moisture content, protein content, and fat content. K, P, and C showed relatively high values in the muscle of the sea bream. Fe showed low contents. As a result of measuring heavy metal component, Cd was not detected in sea bream and mullet, but $0.01{\pm}0.00mg/kg$ was detected in red mine. Other heavy metals were below the reference value or were not detected. Electrophoresis results showed that the band appeared at in red minefish. In the case of sea bream and swordfish, no distinctive features of the band were shown. In the case of sea bream, there was little difference in food science between the similar fish species and the red sea bream fish, but price was different. An environment should be created for consumers to buy the right ingredients at the price they want. It is necessary to educate consumers about food ingredients immediately.

Resistive E-band Textile Strain Sensor Signal Processing and Analysis Using Programming Noise Filtering Methods (프로그래밍 노이즈 필터링 방법에 의한 저항 방식 E-밴드 텍스타일 스트레인 센서 신호해석)

  • Kim, Seung-Jeon;Kim, Sang-Un;Kim, Joo-yong
    • Science of Emotion and Sensibility
    • /
    • v.25 no.1
    • /
    • pp.67-78
    • /
    • 2022
  • Interest in bio-signal monitoring of wearable devices is increasing significantly as the next generation needs to develop new devices to dominate the global market of the information and communication technology industry. Accordingly, this research developed a resistive textile strain sensor through a wetting process in a single-wall carbon nanotube dispersion solution using an E-Band with low hysteresis. To measure the resistance signal in the E-Band to which electrical conductivity is applied, a universal material tester, an Arduino, and LCR meters that are microcontroller units were used to measure the resistance change according to the tensile change. To effectively handle various noises generated due to the characteristics of the fabric textile strain sensor, the filter performance of the sensor was evaluated using the moving average filter, Savitsky-Golay filter, and intermediate filters of signal processing. As a result, the reliability of the filtering result of the moving average filter was at least 89.82% with a maximum of 97.87%, and moving average filtering was suitable as the noise filtering method of the textile strain sensor.

Efficient Treatment of Sewage Sludge by Effective Microorganisms (유효미생물에 의한 하수슬러지의 효율적 처리)

  • Choi, Chung-Sig;Joo, Gil-Jae;Lee, Dong-Hoon;Choi, Choong-Lyeal;Rhee, In-Koo;Choi, Jyung
    • Current Research on Agriculture and Life Sciences
    • /
    • v.17
    • /
    • pp.45-52
    • /
    • 1999
  • This study was conducted to evaluate the effects of microbial inoculation on sewage sludge composting. The number and species of microorganisms in sewage sludge sampled on February were higher than those sampled on August. The composting of sewage sludge is inhibited by the polyacrylamide cation, which was used as a coagulant and known to repress the growth of microorganisms. The growth of all microorganisms was inhibited by the addition of the polyacrylamide cation at a concentration of more than 0.8%. The species and viable counts of microorganisms were observed to increase during composting sewage sludge by inoculation of the effective microorganisms and addition of the pine tree sawdust as a bulking agent, compared with those without inoculation. A variety of organisms in compost(sewage sludge plus sawdust) were observed after composting for 30 days, such as Fragilaria sp., Proales sp., Vorticella sp., Schizothrix sp., Anabaena sp., Zoothaminium sp., Epstylis sp., Arcella sp., Balantidium sp., Actinophrys sp., Synedra sp., Euglypha sp., Ulothrix sp., Anacystis sp., and Clostium sp.

  • PDF

Studies on Photocatalytic Thin Films($TiO_2$, TiO-N) Manufactured by DC Magnetron Sputtering Method and it's Characteristics for Removal of Pollutants (DC 마그네트론 스퍼터링법을 이용한 광촉매박막($TiO_2$, TiO-N)제조 및 오염물질 제거에 관한 연구)

  • Jeong, Weon-Sang;Park, Sang-Weon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.59-66
    • /
    • 2005
  • [ $TiO_2$ ] was deposited by DC magnetron sputtering on glass surface under various sputtering parameters such as discharge power($0.6{\sim}5.2\;kW$, substrate temperature($R.T{\sim}350^{\circ}C$), Ar and $O_2$ flow ratio with $0{\sim}50\;sccm$($Ar+O_2$ 90 sccm) and about 1 mtorr of pressure. TiO-N thin film was prepared under same sputtering conditions for $TiO_2$ thin film except flow ratio($Ar+O_2+N_2$ 90 sccm). The sheet resistance of thin films deposited under these parameters was measured to analyze electronic characteristic and thin film's thickness(${\alpha}$-step), surface roughness(AFM) and formation construction(FE-SEM, XRD) were also measured to draw optimal sputtering parameters. In order to evaluate photo-activity of thin film($TiO_2$, TiO-N) made in optimal parameters for removal of pollutants, toluene among VOCs and Suncion Yellow among reactive dyes were chosen to probe organic compounds for photo-degradation. It was shown that the photo-catalytic thin films had a significant photo-activation for the chosen contaminants and especially TiO-N thin film showed maximum efficiency of 33% for toluene(5 ppm) removal in visible-light range.

P3 in the Auditory Event-Related Evoked Potential of Schizophrenia(I) -P3 in the Schizophrenics- (정신분열증의 사건관련유발전위에 대한 연구(I) -정신분열증 환자의 사건관련유발전위-)

  • Oh, Dong-Jae;Chang, Hwan-Il
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.1
    • /
    • pp.87-98
    • /
    • 1994
  • Objectives: To examine a defect in inhibitory gating of auditory evoked response in schizophrenics, to compare P3 latency and amplitude in negative and positive schizophrenics, and to assess the association of P3 with family history of the psychiatric disorders, electroconvulsive therapy, and clinical features. Methods: 54 schizophrenics(male 31, female 23) and 75 controls(male 33, female 42) were tested with event-related potential paradigm designed to elicit P3 response and Frankfurter Beschwerde Fragebogen. Results: In schizophrenics, the latency of P3 was significantly more delayed and the amplitude of P3 was significantly more reduced than in the controls. Significant differences in P3 latency and amplitude between negative and positive schizophrenics were not found. And significant difference in the P3 latency and amplitude between schizophrenics with family histories of psychiatric disorder and those without family histories of psychiatric disorder was not found also. The P3 latency and amplitude was not significantly related with electroconvulsive therapy and other clinical features such as age, duration of illness, onset of inllness, number of admission, and doses of antipsychotics etc. Conclusion: These results suggested that schizophrenics had a dysfunction in the process of selective attention and that P3 was not significantly related with family history of the psychiatric disorders, positive and negative symptoms, electro1convulsive therapy, and clinical features in schizophrenics.

  • PDF

Study on Improvement of Signal to Noise Ratio for HgI2 Radiation Conversion Sensor Using Blocking Layer (Blocking layer 적용을 통한 HgI2 방사선 변환센서의 신호대 잡음비 향상에 관한 연구)

  • Park, Ji-Koon;Yoon, In-Chan;Choi, Su-Rim;Yoon, Ju-Sun;Lee, Young-Kyu;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

Evaluation of the corrosion property on the welded zone of seawater pipe by A.C shielded metal arc welding (교류 피복아크 용접에 의한 해수 배관 용접부위의 부식 특성 평가)

  • Jeong, Jae-Hyun;Kim, Yun-Hae;Moon, Kyung-Man;Lee, Myeong-Hoon;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.877-885
    • /
    • 2013
  • A seawater pipe of the engine room in the ships is being surrounded with severely corrosive environments caused by fast flowing of the seawater, containing aggressive chloride ion and high conductivity etc.. Therefore, the leakage of the seawater from its pipe have been often occurred due to its local corrosion by aggressive chloride ions. Subsequently, its leakage area is usually welded by AC shielded metal arc welding with various electrodes. In this study, when the sea water pipe is welded with several types of electrodes such as E4301, E4311, E4313 and E4316, a difference of the corrosion resistance on the welding metal zones was investigated using an electrochemical method, observing microstructure, measuring polarization behaviors and hardness. The weld metal zone welded with E4313 electrode exhibited the lowest value of hardness compared to other weld metal zones. In addition, its zone indicated also the best corrosion resistance than those of other weld metal zones. Furthermore, all of the weld metal zones revealed a relatively better corrosion resistance than those of the base metal zones. and also showed higher hardness than the base metal zones.

Radiation detector material development with multi-layer by hetero-junction for the reduction of leakage current (헤테르접합을 이용한 누설전류 저감을 위한 다층구조의 방사선 검출 물질 개발)

  • Oh, Kyung-Min;Yoon, Min-Seok;Kim, Min-Woo;Cho, Sung-Ho;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using a multi-layer technique to decrease dark current. High efficiency materials in substitution for Amorphous Selenium(a-Se) have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using PN junction or Hetero junction already used as solar cell, semiconductor. Particle-In -Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in Particle-In -Binder method. To make up for the weak points, multi-layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity, signal linearity is measured to evaluate multi-layer radiation sensor material.

  • PDF

Physiological Properties of Lactobacillus acidophilus 30SC Exposed to Heat Shock Stress (Heat Shock Stress에 의한 Lactobacillus acidophilus 30SC의 생리적 특성)

  • Moon, Yong-Il;Han, Soo-Min;Park, Dong-Jun;Chi, Youn-Tae;Kim, Kwang-Hyun;Oh, Sejong
    • Food Science of Animal Resources
    • /
    • v.25 no.3
    • /
    • pp.350-356
    • /
    • 2005
  • We examined the enhancement of thermotolerance for storage conferred on Lactobacillus acidophilus 30SC by adaptation to different stresses. The viable cells of Lactobacillus acidophilus 30SC were compared with their viability prior to heating at $45,\;55^{\circ}C\;and\;60^{\circ}C$. Heat-adapted ($45^{\circ}C$ for 15 min) L. acidophilus 30SC in MRS broth exhibited higher survivability at lethal temperature of $55^{\circ}C$ than control. Cellular protein profiles of L. acidophilus 30SC during heat adaptation were examined with SDS-PAGE, and scanning electron microscopy. When L. acidophilus 30SC was heat-adapted at $55^{\circ}C$ for 15min, 5 new protein spots of ca $8\~45\;kDa$ size were observed on 2D SDS-PAGE. It was presumed that new proteins of L. acidophilus 30SC were produced to adapt to the environment of higher growth temperature.

Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires (삼상 다중 접지 배전계통에서 활선로 추적 방법)

  • Zheng, Yan-peng;Byun, Hee-Jung;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.559-562
    • /
    • 2017
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace off-lines with high power impulse injection. Our proposed method use to trace live lines with very small power high frequency signal injection. Typical power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. Two end communication terminals are required to be synchronized between them for determination on electrically same phases. Challenging issue is to achieve synchronization without GPS providing synchronizing time. A novel power transformer and wire identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF