• Title/Summary/Keyword: 전기적 촉진시험

Search Result 42, Processing Time 0.029 seconds

An Experimental Study on the Resistance of Nylon Fiber Reinforced Concrete to Chloride Ion Penetration (나일론섬유보강 콘크리트의 염소이온 침투 저항성에 대한 실험적 연구)

  • Jeon, Joong-Kyu;Moon, Jae-Heum;You, Jin-O
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.557-560
    • /
    • 2008
  • Fiber reinforcement has been being widely used in concrete to enhance the mechanical properties and to reduce the micro-cracking caused by plastic and drying shrinkage. While researches has been focused on the benefits of fiber reinforcement, the properties of fiber reinforced concrete are strongly dependent on the type, shape and the amount of fibers in concrete. In this study, the resistance of nylon fiber reinforced concrete against the chloride ion penetration was experimentally observed by NT Build 492. The test results showed that the addition of nylon fiber has little effect on the change of the resistivity of concrete to the chloride ion penetration.

  • PDF

Introduction of International Standard Test Scenario of the SCADA System with CIM using IEC 61970 (IEC 61970 CIM 기반 SCADA 시스템 표준시험 시나리오)

  • Jang, B.T.;Lee, Y.J.;Lee, N.H.;Han, J.Y.;Kim, S.K.;Choi, J.K.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.573-574
    • /
    • 2015
  • 스마트그리드 전력계통시스템 기술의 중요한 특징중의 하나는 국제표준을 기본으로 탑재하고 있다. 발전소부터 수용가까지 각 영역별로 운영중인 시스템들이 국제표준을 준수한다는 것은 어떤 특정임무만을 담당하는 독립된 시스템이 아닌 타 시스템에 정보를 주고 받는 분산시스템의 구조로 전력시스템 전체 아키텍쳐가 변화하고 있는 것이다. 이러한 환경은 ICT(Information & Communication Technology)와 매우 친화적이며 스마트그리드의 발전을 촉진시킨다. 전력회사마다 운영중인 송변전자동화시스템인 SCADA(Supervisory Control And Data Acquisition)에 대하여 IEC 61970 표준을 지원하는 기능을 갖춘 제품들이 세계시장에 급속히 공급되고 있어 표준을 기반으로 하는 이기종 제품간에 정보교환의 호환성을 검증하는 상호운용성 시험의 중요성이 커지고 있는 실정이다. 본 논문에서는 IEC 61970이 적용된 SCADA 시스템을 대상으로 표준기반의 상호운용성 시험에 대해 기술하고자 한다.

  • PDF

Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment (염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가)

  • Lee, Hae-Seung;Cho, Ggu-Hwan;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.397-405
    • /
    • 2014
  • There are many literatures reporting that the service life of re-bars in concrete structures is reduced in the oceanic environment due to chloride attack. To solve this problem, this study used geo-polymer as a mix material for concrete to increase its resistance to salt damage, and the external voltage method, one of the electric methods, is was applied to evaluate the likelihood of re-bars in the oceanic structure being exposed to the extreme salt environment. The items evaluated include the natural potential of re-bars and the corrosion rate. The results of the tests showed that in all of the salt environmental conditions (submerged zone, tidal zone, and crack), the tested materials were remarkably effective compared with ordinary concrete. The corrosion protective property was found not only in the evaluation of the natural potential but also in the evaluation of the corrosion rate, suggesting that the external voltage method can be used stably for geo-polymer RC structures in an extreme salt environment.

Characteristics for Reinforcement Corrosion and Chloride Ion Diffusion of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 및 염소이온 확산 특성)

  • Kwon, Soon-Oh;Bae, Su-Ho;Lee, Hyun-Jin;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.34-39
    • /
    • 2014
  • The purpose of this experimental research is to evaluate the resistance of reinforcement corrosion and chloride ion penetration of high volume fly ash (HVFA) concrete. For this purpose, concrete test specimens were made for various strength level and replacement ratio of fly ash, and then compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91 and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that compressive strength of HVFA concrete was decreased with increasing replacement ratio of fly ash but long-term resistance against reinforcement corrosion and chloride ion penetration of that was increased.

네트 가전기술의 동향

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.314
    • /
    • pp.58-63
    • /
    • 2003
  • 휴대전화, PC, 브로드밴드(ADSL, FTTH) 등 가정 내에서의 IT기기 및 네트워크의 보급이 급속하게 진전되고 있다. TV와 에어콘 등 가전제품의 IT화가 진행되어 가정 내에서 네트워크를 형성함은 물론 외부 네트워크에 상시 접속되는 세계가 실현되어 가고 있다. 네트워크 접속에 대응하는 네트가전이 보급되면 가전기기 간의 연대 및 외부와의 정보통신에 의해 가전제품의 기능과 성능을 최대한으로 발휘할 수 있게 되어 생활환경, 편리성이 크게 향상됨과 아울러 성(省)에너지화에도 큰 효과를 나타낸다. 네트가전은 TV, VTR, DVD등의 AV계(系), 냉장고와 세탁기 등의 기기계, 태양광발전시스템과 전기온수기 등의 설비계로 분류된다. AV계에서는 디지털정보의 다운로드와 기억에 의해 다양한 고품질의 영상음향에 둘러싸인 세계가 탄생하게 된다 기계계의 네트가전에서는 홈서버 경유로 외출 장소에서 기기의 상태를 파악하여 제어하는 것이 가능해진다. 설비계에서는 설비 간의 연대에 따라 에너지절약 운전과 최대전력량의 제어에 의한 코스트절약이 실현된다. 네트가전을 이용한 홈네트워크 실현을 위해서는 고객이 쉽게 다를 수 있으며 만족할 수 있는 기능과 서비스, 성(省)배전$\cdot$저(低)코스트의 네트워크, 기기가 외부에서 간단히 제어될 수 있는 고신뢰성 인터페이스의 실장(實裝)과 표준화, 디지털 컨텐츠의 유통을 촉진하기 위한 컨텐츠 권리보호제도 정비가 필요하게 된다. 미쓰비시전기는 ''언제나, 어디에나, 누구에게도'' 가전제품을 편리하게 사용될 수 있는 유비쿼터스 사회를 실현하기 위하여 AV, 설비$\cdot$기기, 컴퓨터의 모든 분야에 대응한 가전기기, 네트워크 관련기기의 개발을 진행해 나감은 물론 주택을 이용한 실증시험을 실시하여 소비자 메리트의 본질적인 추구를 위해 계속 추진해 나가고 있다.

  • PDF

The experimental investigation for the curing condition deduce of the Polymer concrete manhole (폴리머 콘크리트 맨홀의 양생 조건 도출을 위한 실험적 고찰)

  • Kim, Dong-Hun;Han, Jin-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.545-548
    • /
    • 2008
  • 불포화 폴리에스테르 수지를 결합재로 사용하여 제작되는 폴리머 콘크리트 맨홀은 조기 고강도 발현, 접착성. 수밀성, 내동결융해성, 내약품성, 내마모성, 전기절연성이 우수하여 프리캐스트로 제작되는 많은 통신용 맨홀에 적용되고 있다. 폴리머 콘크리트의 결합재로 사용되는 불포화 폴리에스테르 수지는 열경화성수지로써, 자체 발열에 의해 거푸집을 탈형할 정도의 초기 경화 반응이 나타나지만, 구조물로서 요구되는 소요 강도를 발휘하기 위해서는 적정 온도에 의한 추가 양생이 반드시 필요하다. 이에 본 논문에서는 폴리머 콘크리트의 휨 강도 시험용 공시체를 사용하여, 다양한 양생 온도 조건 및 양생기간에 따른 휨 강도를 측정하였으며, 이를 가열 촉진 양생에 의한 휨 강도와 비교하여 콘크리트가 소요 강도를 발휘하는데 요구되는 적정 온도와 기간을 도출하였다. 이를 통해 폴리머 큰크리트 맨홀의 품질 확보를 위한 생산 관리와 제품 검사를 체계적이고 효율적으로 수행할 수 있도록 하였다.

  • PDF

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.

Surface and Electrical Properties on EPDM/Silicone Composite Insulator (EPDM/Silicone 복합 절연체의 표면특성과 전기적 특성)

  • Shim, Dae-Sup;Park, Sung-Gyun;Kim, Bum-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.92-95
    • /
    • 2001
  • 고분자 복합체 절연재료는 porcelain 이나 glass 같은 세라믹 소재의 재료와 비교하여 옥외사용 시간의 관점에서 더 뛰어난 특정을 발휘한다. 그러나 노화되었을 때, 이들 옥외용 절연재료의 성질은 발수성이나 흡수성등과 같은 절연재료의 표면특성에 의해 변화한다. 이러한 표면특성의 변화는 누설전류에 의한 트래킹 (tracking), 침식 (erosion) 및 섬락현상(flashover) 등의 유전체 파괴에 이르게 한다. 본 연구에서는 고분자 복합체 절연재료로 널리 이용되고 있는 EPDM의 발수특성을 향상시키기 위해 기존에 이용되던 무기물 첨가제인 alumina hydrate(ATH)이외에 발수성이 뛰어난 실리콘 고무를 상용화제를 이용하여 블렌드하고, 각종 유기 첨가제 및 무기물 보강제를 이용하여 EPDM/Silicone 복합체를 제조하였다. EPDM/Silicone 복합체의 인장강도 및 유전강도는 실리콘의 함량이 증가할수록 낮아졌으며, 촉진 노화시험을 실시한 결과 $120^{\circ}C$까지 인장강도 및 신율을 유지하였다. 유전강도의 측정결과 복합체의 접촉각과 표면에너지 측정결과 Silicone 고무의 함량이 증가할수록 접촉각은 증가하고, 표면에너지는 낮아졌다. 경사평판법에의한 내트래킹성 측정결과 실리콘 함량이 증가할수록 내트래킹성은 우수하였으며, 실리콘 함량이 30%인 복합체에서는 트래킹 및 침식이 진행되지 않았다.

  • PDF

Effect of the Kinds and Replacement Ratios of Mineral Admixtures on the Development of Concrete Resistance against the Penetration of Chloride Ions (혼화재 종류 및 치환율이 콘크리트의 내염성능 향상에 미치는 영향에 관한 연구)

  • Kim Young-Jin;Lee Sang-Soo;Kim Dong-Seuk;Yoo Jae-Kang
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.319-326
    • /
    • 2004
  • This paper investigates the effect of the concrete containing mineral admixtures(pozzolanic materials such as fly-ash, ground granulated blast-furnace slag, silica fume and meta kaolin) on the resistance properties to chloride ion invasion. The purposed testing procedure was applied to the concrete replaced mineral admixtures for 3${\~}$4 replacement ratios under water-binder ratios ranged from 0.40 to 0.55. For the electro-migration test, Tang and Nilsson's method was used to estimate the diffusion coefficient of chloride ion. As a results, the water-binder ratios, kinds of mineral admixtures and replacement ratios, water curing periods had a great effect on the diffusion coefficient of chloride ion, and the optimal replacement ratios had a limitation for each mineral admixtures. Also, the use of mineral admixtures by mass(replacement of OPC) enhance the resistance ability against chloride penetration compared with the plain concrete. The compressive strength was shown related to the diffusion coefficient of chloride ion, the compressive strength increases with the diffusion coefficient of chloride ion decreasing. Below the 50 MPa, the variation of diffusion coefficient of concrete replaced mineral admixtures was bigger than that of plain concrete.

A Method on the Rapid Assessment of Resistance to Chloride Ion Penetration for Mortar and Concrete with Mineral Admixtures (혼화재를 사용한 모르타르 및 콘크리트의 염소이온 침투 저항성 평가)

  • Park Jung-Jun;Kim Sung-Wook;Koh Kyung-Taek;Lee Jong-Suk;Lee Jang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.485-492
    • /
    • 2004
  • In this study, ASTM C 1202 which is most commonly used for evaluating the penetration resistance into the concrete is reviewed. The test results by ASTM C 1202 showed that the passed charge could be underestimated as the $OH^-$ ion concentration in the concrete is lowered when the concrete is mixed with the admixtures. Therefore, the modified method using the distilled water was proposed in the paper. According to the test results, the modified method is not susceptible to $OH^-$ ion and temperature rise. In addition, the long term emersion test for the concrete mixed with the admixtures in the NaCl solution showed that the chloride diffusion coefficient tested by the modified method have higher correlation compared to the conventional ASTM method.