• Title/Summary/Keyword: 전기저항 평가방법

Search Result 212, Processing Time 0.033 seconds

Evaluation of Electric Pulp Test (EPT) as a Tool for Measurement of Dentinal Hypersensitivity (상아질 지각과민 측정 도구로서의 전기치수검사에 대한 평가)

  • Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.371-378
    • /
    • 2002
  • In this study, 40 hypersensitive teeth of 19 patients were investigated. The procedures performed were as follows: Before desensitization, EPT at occlusal third of buccal surface was done for the evaluation of pulp vitality and the EPT value was recorded for the reference value. And mechanical and thermal test was executed for the test of hypersensitivity. If the tooth responded to the above tests, we did EPT at the exposed surface, using toothpaste as a electrolite medium and recorded the EPT value at patient's response. After the tests had been done, desensitization procedures with Gluma(R) Desensitizer were performed according to the manufacturer's instructions. After desensitization, the same tests except EPT at occlusal third were repeated. All the 40 teeth responded positive before desensitization and negative after desensitization procedures. The EPT value at occlusal third ranged from 31 to 65 (48.9${\pm}$7.2). Before desensitization 34 teeth responded at EPT value of 2 and the remaining 6 teeth was in the range of 17 to 25. After desensitization all 40 teeth responded from 12 to 27 (19.6${\pm}$3.5). The 6 teeth responded at greater number than 2 before desensitization was in the range of 18 to 23. Within the limitations of this study we can conclude that: When a tooth with dentinal hypersensitivity responds to mechanical and thermal stimulation, the tooth shows very low resistance to electricity at the exposed surface while when a tooth is desensitized and doesn't show respond to mechanical and thermal stimuli, the tooth shows increased level of resistance to electric stimulation at the exposed surface. EPT can be used for the diagnosis of dentinal hypersensitivity. Furthermore EPT will be useful to evaluate the outcome of desensitization procedures. However, EPT is not a valid tool for measuring dentinal hypersensitivity.

Environmental Geophysical Survey of Abandoned Landfills for Contamination Evaluation: A Case Study (불량 매립지 오염평가를 위한 지구물리 탐사 사례연구)

  • Lee, Sung-Soon;Lee, Jin-Yong;Yoon, Hee-Sung;Lee, Kang-Kun;Kim, Chang-Gyun;Yu, Young-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.463-471
    • /
    • 2006
  • Electrical resistivity surveys were conducted at areas of abandoned landfills in Cheonan and Wonju. Geology and extent of leachate migration around the landfills were evaluated with collected resistivity data by 2-D and 3-D resistivity inverse modeling. The Cheonan landfill is located above the paddy fields and the resistivity survey lines were crossed to examine possible pollution at the paddy fields by leakage of the landfill leachate. In Wonju, the landfill and the downgradient paddy fields are divided by a concrete barrier wall. At the bottom of the landfill, there is a leachate settlement system, which has not been in operation. To evaluate leachate leakage into the paddy fields, a total of 4 survey lines were used. According to the resistivity survey results, the landfill leachate in Cheonan appeared to be restricted only within the interior of the landfill, not to migrate into the subsurface of the paddy fields. These results are well consistent with electrical conductivity values of groundwaters obtained from a periodic analysis of water qualities. In Wonju, however, it was inferred that the leachate emanating from the landfill migrated beneath the abandoned leachate settlement system and the leachate would reach the downgradient paddy fields. Low resistivity area was observed in the old reservoir area and it appeared to be derived from convergence of groundwater flows from the surrounding valley and the moist wet land. In addition, groundwater flow into the paddy fields occurs beneath the old reservoir embankment at depths of $7{\sim}8m$. This paper reports details of the resistivity surveys for the uncontrolled landfills.

Development of High-performance Oxide Semiconductor Thin-Film Transistor with ITO buried layer by Annealed Microwave

  • Pyo, Ju-Yeong;Im, Cheol-Min;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.204.2-204.2
    • /
    • 2015
  • 산화물 반도체는 비정질임에도 불구하고 높은 이동도를 나타내며, 적은 누설 전류, 낮은 소비전력, 저온 공정 가능, 가시광선 영역에서 투명한 성질을 가지고 있다. 이와 같은 다양한 장점들로 인해 산화물 반도체를 이용한 트랜지스터는 차세대 플랫 패널 디스플레이 적용에 있어서 핵심 기술로 각광받고 있다. 한편, 소자의 크기가 점점 더 작아짐에 따라 고집적화에 따른 scaling down은 항상 언급되는 이슈이다. 이와 관련하여 소자의 높은 on current는 트랜지스터를 더 작게 구현할 수 있다는 가능성을 보여준다. 따라서 현재 소자의 on current를 높이기 위해서 소자의 구조를 변형하는 연구가 활발히 진행되고 있다. 본 연구에서는 소자의 on current를 높이기 위한 방법으로 ITO buried layer를 이용한 산화물 반도체 pseudo 트랜지스터를 제작하였다. 먼저 채널을 형성하기 전에 ITO buried layer를 형성시켜준 후, 채널 영역으로서 InGaZnO (2:1:1)를 용액 공정을 이용하여 형성시켰다. 이어서 소자의 전기적 특성 향상을 위해 마이크로웨이브 열처리를 1800 W에서 2분간 실시하였다. 또한 대조군으로 ITO buried layer를 갖지 않는 소자를 같은 방법으로 제작하여 평가하였다. 그 결과 ITO buried later를 갖는 소자에서 대조군과 비교하여 높은 on current를 나타냄을 확인하였다. 이와 같은 결과는 낮은 저항의 ITO buried layer가 current path를 제공함과 동시에 더 두꺼운 채널 층을 형성시켜 높은 on current에 기여하기 때문이다. 결과적으로 ITO buried layer를 갖는 소자 구조를 이용함으로써 고성능 트랜지스터를 제작하여 소자를 집적화 함에 있어서 유망한 소자가 될 것으로 예상된다.

  • PDF

An Estimation Technique of Rock Mass Classes for a Tunnel Design (터널 설계를 위한 암반등급 산정 기법에 관한 연구)

  • 유광호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.319-326
    • /
    • 2003
  • In site investigation for tunnel designs, nowadays, geophysical exploration such as seismic exploration and electric resistivity exploration as well as drilling logging is frequently carried out. A method which can systematically make the utmost use of all available data obtained from investigation, therefore, is strongly required for the optimal evaluation of ground conditions in terms of rock mass class, etc. Many researchers have proposed using qualitative data to cope with the lack of quantitative data. In this study, an evaluation technique of rock mass classes in undrilled region was proposed based upon multiple indicator kriging method which is a geostatistical technique. It was shown that two types of data with different degree of uncertainty, for example, drilling logging data and geophysical exploration data, could be simultaneously utilized in evaluating rock mass classes for a real tunnel design.

다양한 기판에 FTS(Facing Target Sputtering)방법으로 제작된 AZO박막의 광전 특성에 관한 연구

  • ;Seo, Seong-Bo;Kim, Hwa-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.176.1-176.1
    • /
    • 2013
  • TCO (Transparent Conductive Oxide)는 투명 전도성 산화물 높은 투과율과 낮은 비저항 가지고 있어서 최근 사용된 평판디스플레이 LCD(liquid crystal display), PDP (Plasma Display Panel), OLED (Organic Light Emitting Display) 에 많이 사용되고 있다. 현재 양산화 되고 있는 ITO (Indium tin Oxide)는 좋은 전도율과 높은 투과율로서 가장 많이 쓰인다. 하지만 ITO중에 Indium Oxide는 치명적인 독성을 가지고 있으며 In의 저장량이 적어 시간이 갈수록 가격이 비싸지는 등 여러 가지 단점을 가지고 있다. 그것에 비해 AZO (aluminum-doped zinc oxide)는 독성이 없고 가격도 저렴하여 ITO의 단점을 보완 할 수 있는 물질이다. AZO 증착은 현재 sol-gel, CVD(chemical vapor deposition), Sputter, 등으로 사용되고 있으며 현재 많은 연구가 진행되고 있다. 본 실험에서는 PEN 기판을 사용하였으며, 플라즈마의 열적 데미지로 인한 기판의 변형 등 여러 가지 문제를 해결하기 위하여 박막의 열적 변형이 적고, 고밀도 플라즈마로 양질의 박막 증착이 가능한 FTS (Facing Target Sputtering)방법을 사용하여 AZO박막을 증착시키고 구조적, 전기적, 광학적인 특성을 평가 하였다. 측정 분석 결과 AZO는 가시광 영역에 높은 투과율이 요구되는 Flexible display 표시장치와 OLED, PDP, 유기태양전지 등 많은 영역에 사용이 가능 할 것이라 사료된다.

  • PDF

A Study on the Strength Characteristics and Failure Detection of Single-lap Joints with I-fiber Stitching Method (I-fiber 스티칭 공법이 적용된 Single-lap Joint의 강도 특성 및 파손 신호 검출 연구)

  • Choi, Seong-Hyun;Song, Sang-Hoon;An, Woo-Jin;Choi, Jin-Ho
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.317-322
    • /
    • 2021
  • When a complex load such as torsion, low-speed impact, or fatigue load is applied, the properties in the thickness direction are weakened through microcracks inside the material due to the nature of the laminated composite material, and delamination occurs. To prevent the interlaminar delamination, various three-dimensional reinforcement methods such as Z-pinning and stitching, and structural health monitoring techniques that detect the microcrack of structures in real time have been continuously studied. In this paper, the single-lap joints with I-fiber stitching process were manufactured by a co-curing method and their strengths and failure detection capability were evaluated. AE and electric resistance method were used for detection of crack and failure signal and electric circuit for signal analysis was manufactured, and failure signal was analyzed during the tensile test of a single-lap joint. From the experiment, the strength of the single lap joint reinforced by I-fiber stitching process was improved by about 44.6% compared to the co-cured single lap joint without reinforcement. In addition, as the single-lap joint reinforced by I-fiber stitching process can detect failure in both the electrical resistance method and the AE method, it has been proven to be an effective structure for failure monitoring as well as strength improvement.

Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Frequency Spectrum Analysis Method (주파수분석법에 의한 발전소 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk;Lee, In-Cheol;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.10-17
    • /
    • 2000
  • In boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants, conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also, these techniques have low practicality and applied only to component surfaces with good accessibility. It needs to apply a reliable and quantitative ultrasonic nondestructive evaluation method that can be replaced for these equipment. In this study, both artificial creep degradation test using life prediction formula and frequency analysis by ultrasonic tests for crept specimens were carried out for the purpose of nondestructive evaluation for creep damage. As a result of ultrasonic tests for crept specimens, we conformed that the high frequency side spectra decrease and central frequency components shift to low frequency band, and also their bandwidth decreases as increasing creep damage in backwall echos.

  • PDF

Interpretation of Geophysical and Engineering Geology Data from a Test Site for Geological Field Trip in Jeungpyung, Chungbuk (충북 증평 지질학습장 시험부지에 대한 물리탐사 및 지질공학 자료의 해석)

  • Kim, Kwan-Soo;Yun, Hyun-Seok;Sa, Jin-Hyeon;Seo, Yong-Seok;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.339-352
    • /
    • 2016
  • The best way of investigating the physical and mechanical properties of subsurface materials is the combined interpretation of data from borehole geophysical surveys and geotechnical experiments with rock samples. In this study two surface seismic surveys with refraction and surface-wave method are alternatively conducted for downhole seismic surveys in test site for geological field trip in Jeungpyung, Chungbuk. P- and S-wave velocity structures are delineated by refraction and MASW (multichannel analysis of shear waves) methods, respectively. Possion's ratio section, reconstructed from P- and S-wave velocities, is correlated to the outcrop geological features consisting of reddish sedimentary rock, gray volcanic rock, and joints/fractures. In addition, rock samples representative for reddish sedimentary and gray volcanic features are geotechnically analyzed to provide physical, mechanical properties, and elastic modulus. Dynamic elastic moduli estimated from geophysical data is found to be higher than the one from geotechnical data. Reddish sedimentary rock characterized with low porosity and moisture content corresponds to the zone of low electrical resistivities and their small variations in the resistivity sections between the rainy and dry days. This trend suggests that the weathered gray volcanic rock and the nearby fractures with higher low porosity and moisture content are interpreted to be good carrier especially in rainy season.

Comparison of Human Sensibility in Driving Simulator and Roller-Coaster Simulator (자동차 시뮬레이터와 롤러코스터 시뮬레이터 주행에 따른 감성 비교)

  • 민병찬;전효정;강인형;성은정;김철중;윤석준
    • Science of Emotion and Sensibility
    • /
    • v.6 no.3
    • /
    • pp.13-20
    • /
    • 2003
  • In an experimental study, we assessed human sensibility in terms of psychophysiological response according to change of speeds (40, 70, 100km/h) in a driving simulator and application of motion fitters (washout filter, non-washout later) in a roller coaster simulator. For the driving and roller coaster simulators, a group of 12 healthy men in their twenties and a group of 8 healthy men in their twenties, respectively, participated. Participants each completed a simulator sickness questionnaire (SSQ), a subjective assessment of sensations of pleasantness, tension, and arousal, and perception of speed. Physiological signals were measured by 1/f fluctuation of EEG (electroencephalogram), ECG (electrocardiogram), and GSR (galvanic skin response). These were measured pre-to-post under the experimental conditions for each simulator. Subjective pleasantness, tension, arousal, and perception of speed and physiological responses indicating a feeling of pleasantness by 1/f fluctuation were higher for the roller coaster simulator than those measured for low speed driving in the driving simulator. The mean frequency of alpha band (8-l3㎐) in EEG increased with exposure to the driving simulator relative to that for the roller coaster simulator. Heart rate variability and GSR were significantly changed between pre- and post- under each condition in the driving and roller coaster simulators. The data suggest that subjective sensibility was elevated according to gain of speed and variety of simulator motion, and physiological responses were activated with increased speed.

  • PDF

Evaluation of $SrRuO_3$ Buffer Layer for $Pb(Zr,Ti)O_3$ Ferroelectric Capacitor ($Pb(Zr,Ti)O_3$ 강유전체 커패시터에 적용하기 위한 $SrRuO_3$ 버퍼 층의 특성 평가)

  • Kweon, Soon-Yong;Choi, Ji-Hye;Son, Young-Jin;Hong, Suk-Kyoung;Ryu, Sung-Lim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.280-280
    • /
    • 2007
  • $Pb(Zr,Ti)O_3$ (PZT) 강유전체 박막은 높은 잔류 분극 (remanent polarization) 특성 때문에 현재 강유전체 메모리 (FeRAM) 소자에 적용하기 위하여 가장 활발히 연구되고 있다. 그런데 PZT 물질은 피로 (fatigue) 및 임프린트 (imprint) 등의 장시간 신뢰성 (long-term reliability) 특성이 취약한 단점을 가지고 있다. 이러한 신뢰성 문제를 해결할 수 있는 효과적인 방법 중의 하나는 $IrO_2$, $SrRuO_3$(SRO) 등의 산화물 전극을 사용하는 것이다. 많은 산화물 전극 중에서 SRO는 PZT와 비슷한 pseudo-perovskite 결정구조를 갖고 격자 상수도 비슷하여, PZT 커패시터의 강유전 특성 및 신뢰성을 향상시키는데 매우 효과적인 것으로 알려져 있다. 따라서 본 연구는 PZT 커패시터에 적용하기 위하여 SRO 박막을 증착하고 이의 전기적 특성 및 미세구조를 분석하고자 하였다. 또 실제로 SRO 박막을 상부전극과 PZT 사이의 버퍼 층 (buffer layer)으로 적용한 경우의 커패시터 특성도 평가하였다. 먼저 다결정 SRO 박막을 $SiO_2$/Si 기판 위에 DC 마그네트론 스퍼터링 법 (DC magnetron sputtering method)으로 증착하였다. 그 다음 이러한 SRO 박막의 미세구조, 결정성 및 전기적 특성이 증착 조건들의 변화에 따라서 어떤 경향성을 보이는지를 평가하였다. 기판 온도는 $350\;{\sim}\;650^{\circ}C$ 범위에서 변화시켰고, 증착 파워는 500 ~ 800 W 범위에서 변화시켰다. 또 Ar+$O_2$ 혼합 가스에서 산소의 혼합 비율을 20 ~ 50% 범위에서 변화시켰다. 이러한 실험 결과 SRO 박막의 전기적 특성 및 미세 구조는 기판의 증착 온도에 따라서 가장 민감하게 변함을 관찰할 수 있었다. 다른 증착 조건과 무관하게 $450^{\circ}C$ 이상의 온도에서 증착된 SRO 박막은 모두 주상정 구조 (columnar structure)를 형성하며 (110) 방향성을 강하게 나타내었다. 가장 낮은 전기 저항은 $550^{\circ}C$ 증착 온도에서 얻을 수 있었는데, 그 값은 약 $440\;{\mu}{\Omega}{\cdot}cm$ 이었다. SRO 버퍼 충을 적용하여 제작한 PZT 커패시터의 잔류 분극 (Pr) 값은 약 $30\;{\mu}C/cm^2$ 정도로 매우 높은 값을 나타내었고, 피로 손실 (fatigue loss)도 $1{\times}10^{11}$ 스위칭 사이클 후에 약 11% 정도로 매우 양호한 값을 나타내었다.

  • PDF