• Title/Summary/Keyword: 전기저항률

Search Result 263, Processing Time 0.031 seconds

Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model (2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석)

  • Lee, Bok-Hee;Kim, Tae-Ki;Cho, Yong-Seung;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment (염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가)

  • Lee, Hae-Seung;Cho, Ggu-Hwan;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.397-405
    • /
    • 2014
  • There are many literatures reporting that the service life of re-bars in concrete structures is reduced in the oceanic environment due to chloride attack. To solve this problem, this study used geo-polymer as a mix material for concrete to increase its resistance to salt damage, and the external voltage method, one of the electric methods, is was applied to evaluate the likelihood of re-bars in the oceanic structure being exposed to the extreme salt environment. The items evaluated include the natural potential of re-bars and the corrosion rate. The results of the tests showed that in all of the salt environmental conditions (submerged zone, tidal zone, and crack), the tested materials were remarkably effective compared with ordinary concrete. The corrosion protective property was found not only in the evaluation of the natural potential but also in the evaluation of the corrosion rate, suggesting that the external voltage method can be used stably for geo-polymer RC structures in an extreme salt environment.

Effect of pH adjustors in slurry on Ru CMP (Ru CMP에서 슬러리의 pH 적정제에 따른 영향)

  • Kim, In-Kwon;Kwon, Tae-Young;Cho, Byoung-Gwun;Kang, Bong-Kyun;Park, Jin-Goo;Park, Hyung-Soon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.85-85
    • /
    • 2007
  • 최근 귀금속중의 하나인 Ruthenium(Ru)은 높은 일함수, 누설전류에 대한 높은 저항성등의 톡성으로 인해 캐패시터의 하부전극으로 각광받고 있다. 하부전극으로 증착된 Ru은 일반적으로 각 캐패시터의 분리와 평탄화를 위해 건식식각이 이루어진다. 하지만, 건식식각 공정중 유독한 $RUO_4$ 가스가 발생할 수 있으며, 불균일한 캐패시터 표면을 유발할 수 있다. 이러한 문제점들을 해결하기 위해 CMP 공정이 필요하게 되었다. 하지만, Ru은 화학적으로 매우 안정하기 때문에 Ru CMP 슬러리에 대한 연구가 필요하게 되었으며, 이에 대한 연구가 활발히 진행되고 있다. 본 연구에서는 Ru CMP 공정에서 Chemical A가 에칭제 및 산화제로 사용된 슬러리의 pH 변화와 pH 적정제에 따른 영향을 살펴보았다. Ru wafer를 이용하여 static etch rate, passivation film thickness와 wettability를 pH와 pH 적정제에 따라 비교해 보았다. 또한, pH 적정제로 $NH_4OH$와 TMAH를 이용하여 pH별 슬러리를 제작하고 CMP 공정을 실시하여 Ru의 removal rate을 측정하였다. $NH_4OH$와 TMAH의 경우 각각 130. 100 nm/min의 연마율이 측정된 pH 6에서 가장 높은 연마률을 보였으며, TMAH의 경우가 pH 전 구간에서 $NH_4OH$에 비해 낮은 연마율이 측정되었다. TEOS 에 대한 Ru의 선택비를 측정해 본 결과, $NH_4OH$의 경우 pH 8~9. TMAH의 경우 pH 6~7에서 높은 selectivity를 얻을 수 있었다.

  • PDF

The Estimation of the Target Position and Size Using Multi-layer Neural Network in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 다층 신경회로망을 이용한 표적의 위치와 크기 추정)

  • Kim, Ji-Hoon;Kim, Chan-Yong;Cho, Tae-Hyun;Lee, In-Soo
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.35-41
    • /
    • 2018
  • Electrical impedance tomography (EIT) is a kind of nondestructive testing technique that obtains the internal resistivity distribution from the voltages measured at the electrodes located outside the area of interest. However, an image reconstruction problem in EIT has innate non-linearity and ill-posedness, so that it is difficult to obtain satisfactory reconstructed results. In general, a neural network can efficiently model the input and output relationships of a non-linear system. This paper proposes a method for estimating the position and size of a circular target using a multi-layer neural network. To verify the performance of the proposed method, neural network was trained and various computer simulations were performed and satisfactory performance was verified.

Study of Polymer Rapid Setting Cement Concrete Using Electric Arc Furnace Oxidizing Slag Aggregate (전기로(電氣爐) 산화(酸化)슬래그 잔골재를 이용한 폴리머 속경성(速硬性) 시멘트 콘크리트 기초물성(基礎物性) 연구(硏究))

  • Jung, Won-Kyong;Gill, Yong-Soo;Kang, Seung-Hee
    • Resources Recycling
    • /
    • v.21 no.1
    • /
    • pp.30-40
    • /
    • 2012
  • Electric arc furnace slag is made in ironworks during steel refining, it is been increasing chemical and physical resistibility using ageing method of unstable state of melting steel slag for using concrete's fine aggregates. Which is been changing stable molecular structure of aggregates, it restrains moving of ion and molecule. In Korea, KS F 4571 has been prepared for using the electric arc furnace oxidizing slag to concrete aggregates(EFS). In this study, Electric arc furnace oxidizing slag is used in the PRCC(Polymer Rapid setting Cement Concrete) which is applied a bridge pavement of rehabilitation, largely. The results showed that the increment of compressive strength development by 10- 20%. The flexural strength of EFS-Con increased greatly as the electric arc furnace oxidizing slag changed. The compressive strength and flexural strength developed enough for opening the overlayed EFS-Con to the traffic after 4 hours of EFS-Con placement. The permeability of EFS-Con was evaluated as negligible due to its very low charge passed. Thus, EFS-Con could be used at repairing or overlaying the concrete at fast-track job sites.

Comparison of Human Sensibility in Driving Simulator and Roller-Coaster Simulator (자동차 시뮬레이터와 롤러코스터 시뮬레이터 주행에 따른 감성 비교)

  • 민병찬;전효정;강인형;성은정;김철중;윤석준
    • Science of Emotion and Sensibility
    • /
    • v.6 no.3
    • /
    • pp.13-20
    • /
    • 2003
  • In an experimental study, we assessed human sensibility in terms of psychophysiological response according to change of speeds (40, 70, 100km/h) in a driving simulator and application of motion fitters (washout filter, non-washout later) in a roller coaster simulator. For the driving and roller coaster simulators, a group of 12 healthy men in their twenties and a group of 8 healthy men in their twenties, respectively, participated. Participants each completed a simulator sickness questionnaire (SSQ), a subjective assessment of sensations of pleasantness, tension, and arousal, and perception of speed. Physiological signals were measured by 1/f fluctuation of EEG (electroencephalogram), ECG (electrocardiogram), and GSR (galvanic skin response). These were measured pre-to-post under the experimental conditions for each simulator. Subjective pleasantness, tension, arousal, and perception of speed and physiological responses indicating a feeling of pleasantness by 1/f fluctuation were higher for the roller coaster simulator than those measured for low speed driving in the driving simulator. The mean frequency of alpha band (8-l3㎐) in EEG increased with exposure to the driving simulator relative to that for the roller coaster simulator. Heart rate variability and GSR were significantly changed between pre- and post- under each condition in the driving and roller coaster simulators. The data suggest that subjective sensibility was elevated according to gain of speed and variety of simulator motion, and physiological responses were activated with increased speed.

  • PDF

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

Relationship between Tensile Characteristics and Fatigue Failure by Folding or Bending in Cu Foil on Flexible Substrate (유연성 기판에 사용되는 전해 동박의 절곡 및 굴곡 피로 파괴와 인장 특성과의 관계)

  • Kim, Byoung-Joon;Jeong, Myeong-Hyeok;Hwang, Sung-Hwan;Lee, Ho-Young;Lee, Sung-Won;Cbun, Ki-Do;Park, Young-Bae;Joo, Young-Cbang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.1
    • /
    • pp.55-59
    • /
    • 2011
  • Folding endurance, bending fatigue and monotonic tensile tests of 4 kinds of Cu foil on flexible substrate was performed to investigate the relationship between folding or bending endurances and tensile characteristics. The repeated 5.3 or 2.0% strain was applied to Cu foil in folding endurance test or bending fatigue test while monitoring the electrical resistance. Elastic modulus, yield strength, ultimate tensile strength, ductility, and toughness were obtained by monotonic tensile test on the same samples. The Cu foil with higher toughness and ductility showed higher reliabilities in folding or bending fatigue. However, elastic modulus and yield strength did not show any relationship with folding and bending reliability. This is because the failures of Cu foil by folding or bending fatigue were closely related to the fracture energy of metal.

Fabrication of Strain Sensor Based on Graphene/Polyurethane Nanoweb and Respiration Measurement (그래핀/폴리우레탄 나노웹 기반의 스트레인센서 제작 및 호흡측정)

  • Lee, Hyocheol;Cho, Hyeon-seon;Lee, Eugene;Jang, Eunji;Cho, Gilsoo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The purpose of this study is to develop a strain sensor based on a nanoweb by applying electrical conductivity to a polyurethane nanoweb through the use of Graphene. For this purpose, 1% Graphene ink was pour-coated on a polyurethane nanoweb and post-treated with PDMS (Polydimethylsiloxane) to complete a wearable strain sensor. The surface characteristics of the specimens were evaluated using a field emission scanning electron microscope (FE-SEM) to check whether the conductive material was well coated on the surface of the specimen. Electrical properties of the specimens were measured by using a multimeter to measure the linear resistance of the specimen and comparing how the line resistance changes when 5% and 10% of the specimens are tensioned, respectively. In order to evaluate the performance of the specimen, the gauge factor was obtained. The evaluation of the clothing was performed by attaching the completed strain sensor to the dummy and measuring the respiration signal according to the tension using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., U.S.A.). As a result of the evaluation of the surface characteristics, it was confirmed that all the conductive nanoweb specimen were uniformly coated with the Graphen ink. As a result of measuring the resistance value according to the tensile strength, the specimen G, which was treated with just graphene had the lowest resistance value, the specimen G-H had the highest resistance value, and the change of the line resistance value of the specimen G and the specimen G-H is increased to 5% It is found that it increases steadily. Unlike the resistance value results, specimen G showed a higher gauge rate than specimen G-H. As a result of evaluation of the actual clothes, the strain sensor made using the specimen G-H measured the stable peak value and obtained a signal of good quality. Therefore, we confirmed that the polyurethane nanoweb treated with Graphene ink plays a role as a breathing sensor.

이중구조 투명전극을 이용한 실리콘 박막 태양전지 효율향상 기법

  • Kim, Hyeon-Yeop;Kim, Min-Geon;Choe, Jae-U;Lee, Jun-Sin;Kim, Jun-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.591-591
    • /
    • 2012
  • 본 연구는 Transparent conducting oxide (TCO, 산화물투명전극)를 이용한 박막태양전지 효율향상에 관한 것으로, 이중의 TCO층(Double-stacked TCO layer)의 효과적인 광학 및 전기적 설계에 관한 것이다. 기존 박막 태양전지에서는 투명전극 TCO layer로서, ITO (Indium-Tin-Oxide), FTO (Fluorine- Tin-Oxide), 및 AZO(Aluminum-doped Zinc Oxide) 등을 사용해 왔다. 각 TCO layer마다 장점이 있지만 단점 또한 존재한다. ITO의 경우 높은 전기적 특성을 가지는 반면 수소 플라즈마에 취약하고 기계적 강도에 취약해 ITO 단일층만으로 박막 태양전지에 적용하는 것에 제한을 받는다. 한편, AZO의 경우 전기적 특성도 우수할 뿐만 아니라 수소 플라즈마에도 내구성이 강한 장점이 있지만, 일함수가 p형 반도체보다 낮아 Schottky junction이 되어, 높은 전위장벽이 형성된다. 이는 정공의 이동을 방해하고, 정공의 축적이 일어나서 순방향 전압을 인가할 때 많은 전류의 감소를 가져온다. 또한, AZO와 p형 반도체 사이의 높은 직렬저항으로 인해 광전압(Voc, Open circuit voltage)와 충실률 (FF, Fill factor)가 떨어진다는 단점이 있다. 본 실험에서는 ITO/AZO 2중구조의 TCO층을 적용하여 상기의 문제점을 해결하고자 한다. 이중 구조 TCO층은 Magnetron sputter system을 이용하여, 단계적으로 증착되었다. 빛이 입사하는 유리에 ITO를 제1전도층으로 증착하였는데, ITO는 입사광의 투과도와 전기전도성이 우수하다. 제2전도층으로는 AZO층을 이용하였으며, 실리콘 반도체층과 접하게 된다. AZO는 실리콘 증착시 발생하는 수소 플라즈마에 안정적이고, 물리적 강도 또한 우수한 장점이 있다. 이중 구조층위에 실리콘 광흡수층(Si absorber)을 증착하였으며, pin 구조를 가진다. 기존, 단일막 TCO층과 2중구조 TCO층을 이용하여, 실리콘 박막 태양전지를 구성하였다. 이때, ITO/AZO의 2중구조를 적용하였을 때 태양 전지 특성이 크게 향상된 결과를 얻을 수가 있었다. 특히, 전류밀도의 경우 ITO, FTO, AZO 각각 14.5 mA/cm2, 11.2 mA/cm2, 8.18 mA/cm2를 나타낸 반면 ITO/AZO 2중구조의 경우 약 17mA/cm2 로 크게 향상 되었고, 태양전지 변환 효율도 각각 7.5%, 6.9%, 4%에서 ITO/AZO 2중 구조의 경우 8.05%로 크게 향상되었다. 본 발표에서는 2중구조 TCO를 이용한 현공정에 적용 가능한 박막태양전지 효율향상 기법에 대해 논의하고자 한다.

  • PDF